VISHAY B330LA-M3-5AT

New Product
B330LA, B340A
Vishay General Semiconductor
High-Current Density Surface Mount Schottky Rectifier
FEATURES
• Low profile package
• Ideal for automated placement
• Guardring for overvoltage protection
• Low power losses, high efficiency
• Low forward voltage drop
• High surge capability
• Meets MSL level 1, per J-STD-020, LF maximum peak of
260 °C
DO-214AC (SMA)
• Compliant to RoHS Directive 2002/95/EC and in
accordance to WEEE 2002/96/EC
• Halogen-free according to IEC 61249-2-21 definition
TYPICAL APPLICATIONS
PRIMARY CHARACTERISTICS
IF(AV)
3.0 A
VRRM
30 V, 40 V
IFSM
65 A
VF
0.50 V, 0.55 V
TJ max.
150 °C
For use in low voltage, high frequency inverters,
freewheeling, DC/DC converters, and polarity protection
applications.
MECHANICAL DATA
Case: DO-214AC (SMA)
Molding compound meets UL 94 V-0 flammability rating
Base P/N-M3 - halogen-free, RoHS compliant, and
commercial grade
Terminals: Matte tin plated leads, solderable
J-STD-002 and JESD 22-B102
M3 suffix meets JESD 201 class 1A whisker test
per
Polarity: Color band denotes the cathode end
MAXIMUM RATINGS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
Device marking code
B330LA
B340A
B33
B34
UNIT
Maximum repetitive peak reverse voltage
VRRM
30
40
V
Maximum RMS voltage
VRMS
21
28
V
Maximum DC blocking voltage
VDC
30
40
V
Maximum average forward rectified current at TL (fig. 1)
IF(AV)
3.0
A
Peak forward surge current 8.3 ms single half sine-wave
superimposed on rated load
IFSM
65
A
dV/dt
10 000
V/μs
TJ, TSTG
- 65 to + 150
°C
Voltage rate of change (rated VR)
Operating junction and storage temperature range
Document Number: 89415
Revision: 20-Apr-11
For technical questions within your region, please contact one of the following:
www.vishay.com
[email protected], [email protected], [email protected]
1
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
New Product
B330LA, B340A
Vishay General Semiconductor
ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
TEST CONDITIONS
Maximum instantaneous forward voltage
3.0 A
Maximum reverse current at rated VR
SYMBOL
B330LA
B340A
UNIT
TJ = 25 °C
VF (1)
0.5
0.55
V
TJ = 25 °C
(2)
0.5
0.5
mA
B330LA
B340A
UNIT
IR
Notes
(1) Pulse test: 300 μs pulse width, 1 % duty cycle
(2) Pulse test: Pulse width  40 ms
THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted)
PARAMETER
SYMBOL
RJA (1)
Typical thermal resistance
RJL
110
°C/W
(1)
28
Note
(1) Aluminum substrate mounted
ORDERING INFORMATION (Example)
PREFERRED P/N
UNIT WEIGHT (g)
PREFERRED PACKAGE CODE
BASE QUANTITY
DELIVERY MODE
B330LA-M3/61T
0.064
61T
1800
7" diameter plastic tape and reel
B330LA-M3/5AT
0.064
5AT
7500
13" diameter plastic tape and reel
RATINGS AND CHARACTERISTICS CURVES
(TA = 25 °C unless otherwise noted)
80
Peak Forward Surge Current (A)
Average Forward Current (A)
3.5
3.0
2.5
2.0
1.5
1.0
B330LA
B340A
0.5
0
60
40
20
0
0
25
50
75
100
125
150
1
10
100
Lead Temperature (°C)
Number of Cycles at 60 Hz
Fig. 1 - Forward Current Derating Curve
Fig. 2 - Maximum Non-Repetitive Peak Forward Surge Current
www.vishay.com
2
For technical questions within your region, please contact one of the following:
Document Number: 89415
[email protected], [email protected], [email protected]
Revision: 20-Apr-11
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
New Product
B330LA, B340A
Vishay General Semiconductor
1000
Junction Capacitance (pF)
Instantaneous Forward Current (A)
100
10
TJ = 125 °C
1
TJ = 25 °C
0.1
TJ = 25 °C
f = 1.0 MHz
Vsig = 50 mVp-p
100
B330LA
B340A
B330LA
B340A
10
0.01
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1
10
100
Instantaneous Forward Voltage (V)
Reverse Voltage (V)
Fig. 3 - Typical Instantaneous Forward Characteristics
Fig. 5 - Typical Junction Capacitance
Instantaneous Reverse Current (mA)
100
TJ = 150 °C
10
TJ = 125 °C
1
B330LA
B340A
0.1
0.01
TJ = 25 °C
0.001
0
20
40
60
80
100
Percent of Rated Peak Reverse Voltage (%)
Fig. 4 - Typical Reverse Characteristics
PACKAGE OUTLINE DIMENSIONS in inches (millimeters)
DO-214AC (SMA)
Cathode Band
Mounting Pad Layout
0.110 (2.79)
0.100 (2.54)
0.065 (1.65)
0.049 (1.25)
0.177 (4.50)
0.157 (3.99)
0.012 (0.305)
0.006 (0.152)
0.060 (1.52)
MIN.
0.208 (5.28)
REF.
0.090 (2.29)
0.078 (1.98)
0.060 (1.52)
0.030 (0.76)
0.074 (1.88)
MAX.
0.066 (1.68)
MIN.
0.008 (0.203)
0 (0)
0.208 (5.28)
0.194 (4.93)
Document Number: 89415
Revision: 20-Apr-11
For technical questions within your region, please contact one of the following:
www.vishay.com
[email protected], [email protected], [email protected]
3
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 11-Mar-11
www.vishay.com
1