DBLECTRO NPA

N PA
on Pending
20×5×12.8
Features
Small size, light weight.
Low coil power consumption 0.12W.
PC board mounting, SIL terminal
Suitable for household electrical appliance, automation system, electronic equipment, instrument, meter,
telecommunication facilities and remote control facilities.
Ordering Information
NPA A S 5 DC12V
3 Enclosure: S: Sealed NIL: Dust cover
1
2 3
4
5
1 Part number:NPA ;NPA2
2 Contact arrangement: A:1A
4 Contact current:3:3A;5:5A
5 Coil rated Voltage(V):DC:3,4.5,5,6,12,18,24
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance & Voltage drop
Operation
Electrical
life
Mechanical
1ASPSTNO
Silver AlloyGold clad
3A,5A/30VDC,250VAC ;
150W 1250VAC
110VDC 250VAC
አ30m( at 1A/6V)
1105
2107
min Load:0.1mA/0.1VDCreference value
Max. Switching Current:5A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
CAUTION:
Relays previously tested or used above 10mA resistive at 6VDC maximum or peak AC open circuit are not
recommended for subsequent use in low level applications.
Coil Parameter
Dash
numbers
Coil voltage
VDC
Rated
Rated
current
mA
Coil
resistance
±10%
Max.
Pickup
voltage
VDC(max)
(70%of
rated
voltage )
release
voltage
VDC(min)
(5% of
rated
voltage)
NPA-005
5
6
24
208
3.5
0.25
NPA-006
6
7.2
20
300
4.2
0.3
NPA-009
9
10.8
13.3
675
6.3
0.45
NPA-012
12
14.4
10
1200
8.4
0.6
NPA-018
18
21.6
6.7
2700
12.6
0.9
NPA-024
24
28.8
5
3200
16.8
1.2
Coil power
Consumption
W
Operate
Time
ms
Release
Time
ms
0.12
6
3
0.18
6
3
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
39
www.dblectro.com
NPA
Operation condition
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
1000M
min (at 500VDC)
Item 7 of IEC255-5
50Hz 1000V
50Hz 2000V
Item 6 of IEC255-5
Item 6 and 8 of IEC255-5
Shock resistance
Functional 147m/s2 11ms
Survival980m/s2 6ms
10~55Hz Functional double amplitude 2.5mm
Survivaldouble amplitude 3.5mm
5N
2352 30.5s
-40~70
5%~85% (at 40)
3g
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
Surge voltage:4kV
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24.
Dimensions (Unit: mm)
NPA
NPA2
Mounting (Bottom views)
mm
0.25
0.3
0.5
0.8
1.1
1.2
1.3
2.54
3.5
5.0
5.08
10.16
12.5
20
inch
0.010
0.012
0.020
0.031
0.046
0.047
0.051
0.100
0.138
0.197
0.200
0.300
0.504
0.787
Dimensions
Wiring diagram
(Bottom views)
NOTES 1).Dimensions are in millimeter.
2).Inch equivalents are given for general information only.
www.dblectro.com