JZC-7F(N4099) E158859 Patent No.99204096.5 22×16.5×16.5 Features Small size, light weight, Low price. Sensitive operation, good synchronism. Low coil power consumption. PC board mounting. Suitable for electrical application, telecommunication, automatic control, wireless radio remote control and sound control toy application. Ordering Information JZC-7F 10 DC12V S 0.6 1 2 3 4 5 4 Enclosure:S: Sealed type;NIL: Dust cover 5 Coil power consumption:0.5:0.5W;0.6:0.6W 1 Part number:JZC-7F(4099) 2 Contact Current:01:1A;05:5A;10:10A 3 Coil rated Voltage(V):DC:3,6,9,12,24 Contact Data Contact Arrangement Contact Material Contact Rating (resistive) Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical life Mechanical 2ADPSTNO 2BDPSTNC 2CDPDT(B-M) AgCdO (Au clad) AgSnO2 (Au clad) 0.5W:1A,2A,3A/277VAC,30VDC; 0.6W:3A,5A,10A/277VAC,30VDC 0.5W:90W 360VA; 0.6W:250W 1600VA 50VDC 380VAC Max. Switching Current:10A አ50m Item 3.12 of IEC255-7 105 Item 3.30 of IEC255-7 107 Item 3.31 of IEC255-7 Coil Parameter Dash numbers 003-500 006-500 009-500 012-500 024-500 003-600 006-600 009-600 012-600 024-600 Coil voltage VDC Rated Max. 3 6 9 12 24 3 6 9 12 24 3.9 7.8 11.7 15.6 31.2 3.9 7.8 11.7 15.6 31.2 Coil resistance ±10% Pickup voltage VDC(max) (75%of rated voltage ) release voltage VDC(min) (10% of rated voltage) 18 72 162 288 1152 15 60 135 240 960 2.25 4.50 6.75 9.00 18.0 2.25 4.50 6.75 9.00 18.0 0.3 0.6 0.9 1.2 2.4 0.3 0.6 0.9 1.2 2.4 Coil power consumption W Operate Time ms Release Time ms 0.5 10 5 0.6 10 5 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. 73 www.dblectro.com JZC-7F (N4099) Operation condition Insulation Resistance Dielectric Strength Between contacts Between contact and coil 100M min (at 500VDC) Item 7 of IEC255-5 50Hz 750V 50Hz 1000V Item 6 Item 6 Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 100m/s2 11ms 10~55Hz amplitude 1.5mm 10N 2352 30.5s -40~70 85% (at 40) 12g IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 IEC68-2-20 Test Ta method 1 of IEC255-5 of IEC255-5 IEC68-2-3Test Ca Qualification inspection: Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24. Safety approvals Safety approval Load UL&CUR 5A/277VAC 30VDC Dimensions (Unit: mm) Dimensions Mounting (Bottom views) mm >àçÇá 0.3 0.5 1.0 1.5 2.1 2.5 4.5 5.1 10.2 12.7 16.5 22 0.012 0.020 0.039 0.059 0.083 0.098 0.177 0.201 0.401 0.500 0.650 0.886 Wiring diagram(Bottom views) NOTES 1).Dimensions are in millimeter. 2).Inch equivalents are given for general information only. Reference Data www.dblectro.com