EPCOS B25832C4506K009

MKV AC Capacitors
B25832
MKV AC capacitors
General AC applications
Ordering code:
Date:
B25832
September 2005
© EPCOS AG 2005. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
MKV AC Capacitors
B25832
General AC Applications
Features
■ Compact design
■ Long-term stability and reliability
Applications
■ For commutation in the low-frequency range
Construction
■
■
■
■
■
■
■
Self-healing
Plastic dielectric
Oil-impregnated tubular windings (no PCB)
Metal-sprayed end faces ensure reliable contacting
Cylindrical aluminum case
Ceramic or plastic lead-throughs
Mounting bolts M8 or M12
Terminals
■ Tab connectors 6.3 mm
■ Dual tab connectors 6.3 mm
Mounting
■ If the vibration stress is ≤ 5 g and the capacitors
are ≤ 60 mm in diameter, the bolt is used for mounting.
Grounding
■ Mounting bolts for grounding in accordance with VDE 0100
■ Grounding identification in accordance with DIN 40 011
Individual data sheets
Individual data sheets contain detailed specification incl. thermal data.
Upon request, these data sheets are available for each capacitor type.
Please read Cautions and warnings and
Important notes at the end of this document.
2
09/05
MKV AC Capacitors
B25832
General AC Applications
Technical data
Standards
IEC 1071-1/2
EN 61071-1/2
VDE 0560 part 120 and 121
tan δ0
Dielectric dissipation factor
2 · 10 –4
± 10 %
Capacitance tolerance
Max. repetitive rate
of voltage rise
(dv/dt)max
Max. non-repetitive rate
of voltage rise
(dv/dt)s
î
---C
I
---SC
Min. operating temperature
Tmin
– 25 °C
Max. operating temperature
Tmax
+ 85 °C
Climatic data:
≤ 75 %
Average relative humidity
Failure quota
αFQ(co)
1000 failures per 109 component hours
Load duration
tLD(co)
up to 30 000 h
Storage temperature limit
Tstg
– 55/+ 85 °C
IEC climatic category
(IEC 68-1 and 2)
25/085/56
Test data:
AC test voltage
between terminals
VTT
1.25 x VR, 50 Hz, 10 s (or DC 1.75 x VR, 10 s)
between terminals and case
VTC
2 · V i + 1000 V, 50 Hz, 10 s
Insulating voltage Vi = max. recurrent peak
voltage vˆ / 2
R ins
≤ 1 μF: ≥ 3000 MΩ
Insulation resistance
Self-discharge time constant
Dissipation factor
Please read Cautions and warnings and
Important notes at the end of this document.
> 1 μF: ≥ 3000 s
≤ 3 . 10 –4
τ = R ins x C
tan δ
3
09/05
MKV AC Capacitors
B25832
General AC Applications
Characteristics and ordering codes
CR1)
Imax
î
Is
Lself Dimensions Fig. Appr. Ordering code
RS
20 °C
d×l
weight
μF
A
A
A
mΩ
nH mm
vˆ = 800 V
vs = 1100 V
VR = AC 640 V
1.0
1.5
1.6
2.0
2.2
2.5
3.0
3.0
3.3
4.0
4.7
5.0
6.0
6.8
7.0
8.0
10
12
14
15
16
20
22
25
30
33
40
47
50
10
10
16
16
10
16
10
16
10
16
16
16
18
16
16
18
18
18
18
18
18
18
18
18
18
18
18
18
18
40
25
60
80
35
100
50
120
50
60
75
80
240
110
110
130
160
190
220
240
260
320
350
400
480
530
640
750
800
100
60
160
200
90
250
120
300
130
160
190
200
600
270
280
320
400
480
560
600
640
800
880
1000
1200
1300
1600
1900
2000
24.0
54.0
16.0
13.0
39.0
12.0
30.0
11.0
28.0
24.0
21.0
20.0
5.6
17.0
16.0
12.0
10.0
9.4
8.6
8.1
7.8
7.0
6.7
6.2
6.8
6.6
6.2
6.1
5.9
50
90
50
50
90
50
90
50
90
90
90
90
70
90
90
90
90
90
90
90
90
90
90
90
140
140
140
140
140
g
VTT = AC 800 V, 10 s
VTC = AC 2200 V, 10 s
25 × 48
25 × 80
30 × 48
30 × 48
25 × 80
35 × 48
25 × 80
35 × 48
25 × 80
30 × 80
30 × 80
30 × 80
45 × 57
35 × 80
35 × 80
40 × 86
40 × 86
45 × 86
50 × 86
50 × 86
50 × 86
55 × 86
60 × 86
60 × 86
50 × 156
50 × 156
55 × 156
60 × 156
60 × 156
3
3
4
4
3
5
3
5
3
4
4
4
1
5
5
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1) Other capacitance values upon request
Please read Cautions and warnings and
Important notes at the end of this document.
4
09/05
30
50
50
50
50
60
50
60
50
70
70
70
110
100
100
130
130
160
200
200
200
250
300
300
370
370
450
550
550
B25832F4105K001
B25832F4155K001
B25832F4165K001
B25832F4205K001
B25832F4225K001
B25832F4255K001
B25832F4305K001
B25832F4305K011
B25832F4335K001
B25832F4405K001
B25832F4475K001
B25832F4505K001
B25832C4605K009
B25832F4685K001
B25832F4705K001
B25832C4805K009
B25832C4106K009
B25832C4126K009
B25832C4146K009
B25832C4156K009
B25832C4166K009
B25832C4206K009
B25832C4226K009
B25832C4256K009
B25832C4306K009
B25832C4336K009
B25832C4406K009
B25832C4476K009
B25832C4506K009
MKV AC Capacitors
B25832
General AC Applications
Characteristics and ordering codes
CR1)
Imax
î
Is
Lself Dimensions Fig. Appr. Ordering code
RS
20 °C
d×l
weight
μF
A
A
A
mΩ
nH mm
vˆ = 1200 V
vs = 1600 V
VR = AC 930 V
1.5
2.0
2.5
3.0
4.0
5.0
5.5
6.0
7.0
8.0
10
12
15
18
20
22
10
10
16
18
18
18
18
18
18
18
18
18
18
18
18
18
45
60
75
90
120
150
170
180
210
240
300
360
450
540
600
660
110
150
190
230
300
380
410
450
530
600
750
900
1100
1400
1500
1700
33.0
26.0
22.0
17.0
14.0
12.0
11.0
10.0
9.2
8.5
7.5
6.7
7.0
6.5
6.3
6.2
90
90
90
90
90
90
90
90
90
90
90
90
110
110
110
110
g
VTT = AC 1200 V, 10 s
VTC = AC 2700 V, 10 s
30 × 80
30 × 80
35 × 80
40 × 86
40 × 86
45 × 86
45 × 86
50 × 86
50 × 86
55 × 86
60 × 86
60 × 86
79.2 × 104
79.2 × 104
89.3 × 104
89.3 × 104
4
4
5
1
1
1
1
1
1
1
1
1
2
2
2
2
1) Other capacitance values upon request
Please read Cautions and warnings and
Important notes at the end of this document.
5
09/05
70
70
100
130
130
160
160
200
200
250
300
300
600
600
800
800
B25832F6155K001
B25832F6205K001
B25832F6255K001
B25832C6305K009
B25832C6405K009
B25832C6505K009
B25832C6555K009
B25832C6605K009
B25832C6705K009
B25832C6805K009
B25832C6106K009
B25832C6126K009
B25832C6156K009
B25832C6186K009
B25832C6206K009
B25832C6226K009
MKV AC Capacitors
B25832
General AC Applications
Dimensional drawing 1
Dual tab connectors 6.3 mm
Dimensional drawing 2
Dual tab connectors 6.3 mm
6,3±0,1
6,3±0,1
8+0,5
l
l
13,5 max.
13,5 max.
8+0,5
16+1
ød 1
0,8±0,04
0,8±0,04
d
24
d
24
6,8+0,2
6,8+0,2
l1
M12
KLK0908-V
KLK1264-3
Dimensions in mm
d +0.5
–0.2
l +1
–2
Dimensions in mm
l1+1*) Creepage
distance
Clearance
d –1.2
l –4
∅ d1–0.4 Creepage
distance
40
86
8
79.2
104
75.2
45
45
57
86
8
8
89.3
104
85.2
50
50
86
156
12
12
55
55
86
156
12
12
60
60
86
156
12
12
7
7
5
*) 8 mm = threaded bolt M8
12 mm = threaded bolt M12
Mounting parts (included in delivery)
Threaded bolt
Max. torque
Toothed washer
Hex nut
M8
4 Nm
J 8.2 DIN 6797
M 8 DIN 439
M12
10 Nm
J 12.5 DIN 6797
M12 DIN 439
Please read Cautions and warnings and
Important notes at the end of this document.
6
09/05
Clearance
5
MKV AC Capacitors
B25832
Dimensional drawing 3
Tab connectors 6.3 mm
Dimensional drawing 4
Tab connectors 6.3 mm
18 max.
18 max.
General AC Applications
Tab connector
A 6,3 x 0,8
DIN 46 244
8+1
M8
2
1
d
1
d
2
15,5±0,5
M8
15,5±0,5
8+1
l
l
Tab connector
A 6,3 x 0,8
DIN 46 244
KLK1415-M
KLK1416-V
Dimensions in mm
Dimensions in mm
d +0.5
–0.2
l±2
25
25
48
80
Creepage
distance
Clearance
d +0.5
–0.2
l±2
9
7
30
30
48
80
Creepage
distance
Clearance
9
7
Mounting parts (included in delivery)
Threaded bolt
Max. torque
Toothed washer
Hex nut
M8
4 Nm
J 8.2 DIN 6797
M8 DIN 439
Please read Cautions and warnings and
Important notes at the end of this document.
7
09/05
MKV AC Capacitors
B25832
General AC Applications
13 max.
Dimensional drawing 5
Tab connectors 6.3 mm
8+1
l
Tab connector
A 6,3 x 0,8
DIN 46 244
1
d
2
15,5±0,5
M8
KLK1418-C
Dimensions in mm
d +0.5
–0.2
l±2
35
35
48
80
Creepage
distance
Clearance
6
6
Mounting parts (included in delivery)
Threaded bolt
Max. torque
Toothed washer
Hex nut
M8
4 Nm
J 8.2 DIN 6797
M8 ISO 4035
Please read Cautions and warnings and
Important notes at the end of this document.
8
09/05
MKV AC Capacitors
B25832
General AC Applications
Cautions and warnings
Safety
■ In case of dents of more than 1 mm depth or any other mechanical damage, capacitors must not
be used at all. This applies also in cases of oil leakage.
■ Electrical or mechanical misapplication of capacitors may be hazardous. Personal injury or prop-
■
■
■
■
■
■
erty damage may result from bursting of the capacitor or from expulsion of oil or melted material
due to mechanical disruption of the capacitor.
Ensure good, effective grounding for capacitor enclosures.
Observe appropriate safety precautions during operation (self-recharging phenomena and the
high energy contained in capacitors).
Handle capacitors carefully, because they may still be charged even after disconnection.
The terminals of capacitors, connected bus bars and cables as well as other devices may also
be energized.
Follow good engineering practice.
Failure to follow cautions may result, worst case, in premature failures, bursting and fire.
Thermal load
After installation of the capacitor it is necessary to verify that maximum hot-spot temperature is not
exceeded at extreme service conditions (see www.epcos.com/thermal_design).
Mechanical protection
The capacitor has to be installed in a way that mechanical damages and dents in the aluminum can
are avoided.
Storage and Operating Conditions
Do not use or store capacitors in corrosive atmosphere especially where chloride gas, sulfide gas,
acid, alkali, salt or the like are present. In dusty environments, regular maintenance and cleaning
especially of the terminals is required to avoid conductive path between phases and/or phases and
ground.
Overpressure disconnector
To ensure full functionality of an overpressure disconnector, the following must be observed:
■ The elastic elements must not be hindered, i.e.
– connecting lines must be flexible leads (cables),
– there must be sufficient space (minimum 12 mm) above the connections for expansion of the
overpressure disconnector,
– folding crimps must not be retained by clamps.
■ Stress parameters of the capacitor must be within the IEC61071 specification.
Service life expectancy
Electrical components do not have an unlimited service life expectancy; this applies to self-healing
capacitors too. The maximum service life expectancy may vary depending on the application the
capacitor is used in.
9
09/05
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements
about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with
them than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components
or failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the
malfunction or failure of a passive electronic component could endanger human life or health
(e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of
protective circuitry or redundancy) that no injury or damage is sustained by third parties in the
event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as “hazardous”). Useful information on this will be found in our Material
Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed
questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version
of the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, CeraDiode, CSSP, PhaseCap, PhaseMod, SilverCap, SIFI, SIMID,
SIKOREL, SIOV, SIP5D, SIP5K, TOPcap, UltraCap, WindCap are trademarks registered or
pending in Europe and in other countries. Further information will be found on the Internet at
www.epcos.com/trademarks.
10
09/05