EPCOS B44066T0200E690

Film Capacitors – Power Factor Correction
Thyristor Module
Series/Type:
Ordering code:
TSM-HV200
B44066T0200E690
Date:
Version:
2010-04-12
4
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!
Identification/Classification 1
(header 1 + top left bar):
Film Capacitors – Power Factor Correction
Identification/Classification 2
(header 2 + bottom left header bar):
Thyristor Module
Ordering code: (top right header bar)
B44066T0200E690
Series/Type: (bottom right header bar)
TSM-HV200
Preliminary data (optional):
(if necessary)
Department:
Film PC PM PFC
Date:
2010-04-12
Version:
4
 EPCOS AG 2010. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
Film Capacitors – Power Factor Correction
Thyristor Module
B44066T0200E690
TSM-HV200
Characteristics
 Fast electronically controlled self-observing thyristor switch
 Usage in dynamic (fast) power factor correction systems
 For capacitive loads up to 200 kvar up to 690 V line
voltage
Features
 No neutral conductor required
 Micro-processor controlled thyristor switching module
(TSM) for standard and detuned capacitor branches for
optimized switching behavior
 Permanent self-monitoring of voltage, phase sequence,
temperature; display of status via LED
 No system perturbation due to switching operations
(transients)
 Switching without delay
 Very low maintenance efforts
 Long useful service life
 No noise emission during switching operation
 Compact module ready for connection
Technical data
Dimensions
410 x 400 x 250 mm (w × h × d)
Weight
17 kg
Voltage
690 V
Maximum voltage
- in conventional PFC-systems
(without reactors)
690 V
- in detuned PFC-systems (7% detuning)
690 V
690 V
- in detuned PFC-systems (14% detuning)
Frequency
50 Hz/60 Hz
Max. power
200 kvar
Auxiliary supply
Not required
Activation
10 … 24 V DC (20 mA), via terminal clamp; internally
insulated
Monitoring
Net voltage, temperature and operation status
Note: Before re-switching after temperature fault, heat
sink temperature must be below 50 °C (hysteresis)!
Display
6 LEDs/phase: operation/error each phase, triggering
signal, over temperature
Film PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
2010-04-12
Page 2 of 6
Film Capacitors – Power Factor Correction
Thyristor Module
Power circuit
Power dissipation
Fuses* (required for protection of TSM-HV
and capacitor):
B44066T0200E690
TSM-HV200
Direct connection 4-pole via bus bar cable lug
max. 70 mm2, D = 8 mm
connection inside the device
PD (W) = 2.0 • I (in A); at 690 V / 200 kvar typical
350 W thermal
Note: Take care of proper air convention (forced
cooling) inside the panel (switchboard)!
3 • electronic fuse „superflink“ (NH2 AC 690 V)
100 kvar: 160 A (e.g. SIBA 20 212 34-160 )
200 kvar: 250 A (e.g. SIBA 20 212 34-250 )
Switching time
approx. 5 ms
Operating ambient temperature with nominal
load
–10 ... +50 °C
Assembling
Directly on mounting plate
Mounting position
Vertical, minimum 200 mm distance upwards and
downwards
*not included in the delivery
Film PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
2010-04-12
Page 3 of 6
Film Capacitors – Power Factor Correction
Thyristor Module
B44066T0200E690
TSM-HV200
Connection diagram
Three-phase load (standard)
Film PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
2010-04-12
Page 4 of 6
Film Capacitors – Power Factor Correction
Thyristor Module
B44066T0200E690
TSM-HV200
Cautions and warnings
General




Thyristor modules TSM series may only be used for the purpose they have been designed for.
Thyristor modules TSM series may only be used in combination with appropriate pre-switched grid
separator device.
Thyristor modules have to be projected in such a way that in case of any failure no uncontrolled
high currents and voltages may occur.
The devices in operation have to be protected against moisture and dust, sufficient cooling has to
be assured.
Attention
Due to the switching principle of the thyristor module the power-capacitors are permanently loaded to
the peak value of the grid voltage (up to 3.500 V DC!) even when switched off! Therefore, following
rules have to be obeyed in any case:

Single-phase capacitors of 525 V nominal voltage in star connection have to be used.

In dynamic PFC-systems with TSM-modules no fast discharge reactors may be used
(reactor = DC-wise short circuit.)

For standard PFC-systems (without reactors) current limitation reactors are mandatory!

Thyristor modules in general have to be protected by superfast electronic fuses. Principles for
dimensioning have to be considered. Fuses in the system have to be marked!

Due to the special switching, the PFC-capacitors are fully loaded even when the particular step
has been switched off. Protection against contact has to be guaranteed. Warning signals in the
system are mandatory!

Even in switched off state no electrical isolation is achieved for electronic switches. Therefore
parts of the systems may not be touched after switching off the complete system before the
capacitors have been completely discharged.
FAILURE TO FOLLOW CAUTIONS MAY RESULT, WORST CASE, IN PREMATURE FAILURES
OR PHYSICAL INJURY.
Note
For detailed information about PFC capacitors and cautions, refer to the latest version of EPCOS PFC
Product Profile.
Film PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
2010-04-12
Page 5 of 6
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As a
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or failure
before the end of their usual service life cannot be completely ruled out in the current state
of the art, even if they are operated as specified. In customer applications requiring a very high
level of operational safety and especially in customer applications in which the malfunction or
failure of an electronic component could endanger human life or health (e.g. in accident
prevention or life-saving systems), it must therefore be ensured by means of suitable design of the
customer application or other action taken by the customer (e.g. installation of protective circuitry
or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or
failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material
Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed
questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently,
we cannot guarantee that all products named in this publication will always be available.
The aforementioned does not apply in the case of individual agreements deviating from the
foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of
the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic,
DSSP, FormFit, MiniBlue, MiniCell, MKD, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube,
PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer,
SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe
and in other countries. Further information will be found on the Internet at
www.epcos.com/trademarks.
Page 6 of 6