EPCOS B44066S2410J230

Film Capacitors – Power Factor Correction
Key Components – Capacitor Contactors
Series/Type:
Ordering code:
B44066S
B44066S….J230/J110/N230
Date:
Version:
August 2009
8
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
table and then change the color to "white". This ensures that the table disappears (invisible) for the customer PDF.
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!
Identification/Classification 1
(header 1 + top left bar):
Film Capacitors – Power Factor Correction
Identification/Classification 2
(header 2 + bottom left header bar):
Key Components – Capacitor Contactors
Ordering code: (top right header bar)
B44066S….J230/J110/N230
Series/Type: (top right header bar)
B44066S
Preliminary data (optional):
(if necessary)
Preliminary data
Department:
FK PC PM PFC
Date:
August 2009
Version:
8
 EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited
Film Capacitors – Power Factor Correction
Key Components – Capacitor Contactors
B44066S….J230/J110/N230
B44066S
Preliminary data
Series B44066S.…J230 with precharging resistors
Characteristics
 Excellent damping of inrush current
 Improved power quality (e.g. avoidance of
voltage sags)
 Longer useful life of main contacts of capacitor
contactor
 Soft switching of capacitor and thus longer useful
life
 Enhanced mean life expectancy
 Reduced ohmic losses
 Easy access for cable connection
 AC6b utilization category for switching 3-phase
capacitors
B44066S….J230/J110
Features
Resistors
Leading contacts
Tamper-proof and protected
With wiper function
Pre-contacts
Snap function
Aux-contacts
For all types
In applications with or
without reactors
Usage
B44066S9910J230
Series B44066S.…N230 for de-tuned PFC-systems with reactors only
Characteristics




Cost efficient
Optimized for capacitor switching
Long useful life of main contacts of capacitor contactor
Easy access for cable connection of capacitors
Features
Aux-contacts
Usage
For all types
In applications with reactors
only
B44066S….N230/N110
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
August 2009
Page 2 of 7
Film Capacitors – Power Factor Correction
Key Components – Capacitor Contactors
B44066S….J230/J110/N230
B44066S
Preliminary data
Technical Data
To IEC 947-4-1, IEC 947-5-1, EN 60947-4-1, EN 60947-5-1, VDE 0660
Type/
Main contacts
Capacitor power
at 50 °C
 380 ... 400 V
 415 ... 440 V
 660 ... 690 V
Capacitor power
at 60 °C
 380 - 400 V
 415 - 440 V
 660 - 690 V
Coil operating
voltage at 50 Hz:
 Type ... 230
 Type …110
Coil operating
voltage at 60 Hz:
 Type ... 230
 Type ... 110
Rated op. current
AC6b at 50/60 Hz
 50 °C
 60 °C
Power loss
contactor at max.
rated capacitor
current
Rated insulation
voltage
Max. frequency of
operations:
Contact life:
 w/o reactors
 with reactors
Cable cross section
 Solid or
stranded
 Flexible
Flexible with
multicore cable
end
Cables / clamp
2 cables per pole
for cable cross
section:
 Solid or
stranded
 Flexible
Weight including
auxiliary contact:
 Type …N…
 Type …J…
Fuses gL (gG)
From / to
…1810…
…2410…
…3210…
…5010…
…6210…
kvar
0 ... 12.5
0 ... 13
0 ... 20
10 ... 20
10.5 ... 22
17 ... 33
10 ... 25
10.5 ... 27
17 ... 41
20 ... 33.3
23 ... 36
36 ... 55
20 ... 50
23 ... 53
36 ... 82
20 ... 75
23 ... 75
36 ... 120
33 ... 100
36 ... 103
57 ... 148
kvar
0 ... 12.5
0 ... 13
0 ... 20
10 … 20
10.5 ... 22
17 ... 33
10 ... 25
10.5 ... 27
17 ... 41
20 ... 33.3
23 ... 36
36 ... 55
20 ... 50
23 ... 53
36 ... 82
20 ... 60
23 ... 64
36 ... 100
33 ... 90
36 ... 93
57 ... 148
187 - 264
85 - 121
187 - 264
85 - 121
187 - 264
85 - 121
187 - 264
not available
187 - 264
85 - 121
187 - 264
85 - 121
187 - 264
not available
196 - 290
94 - 134
196 - 290
94 - 134
196 - 290
94 - 134
196 - 290
not available
196 - 290
94 - 134
196 - 290
94 - 134
187 - 264
not available
0 - 18
0 - 18
14 - 28
14 - 28
14 - 36
14 - 36
30 - 48
30 - 48
30 - 72
30 - 72
30 - 108
30 - 87
50 - 144
50 - 130
W
4.1
5.7
7.5
12.6
21
38.7
36
V AC
6901)
6901)
6901)
6901)
6901)
6901)
10001)
1/h
120
120
120
120
120
80
80
Million
operations
0.25
0.40
0.15
0.30
0.15
0.30
0.15
0.30
0.15
0.30
0.12
0.20
0.12
0.20
1.5 ... 6
2.5 ... 25
2.5 ... 25
4 ... 50
4 ... 50
4 ... 50
1.5 ... 4
2.5 ... 16
2.5 ... 16
10 ... 35
10 ... 35
10 ... 35
1.5 ... 4
2.5 ... 16
2.5 ... 16
10 ... 35
10 ... 35
10 ... 35
0.5 ... 95 /
10 ... 120
0.5 ... 70 /
10 ... 95
0.5 ... 70 /
10 ... 95
2
1
1
1
1
1
2
mm2
(max.)
6/6
10/10
10/10
16/16
16/16
16/16
95/120
4/4
10/10
10/10
25/25
25/25
25/25
70/95
kg
0.26
0.37
0.51
0.67
0.51
0.67
0.88
1.03
0.88
1.03
0.88
1.03
2.23
2.33
A
35 / 63
50 / 80
63 / 100
80 / 160
125 / 160
160 / 200
160 / 250
V AC
V AC
A
mm2

1)
…7410…
…9910…
Suitable at 690 V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Vimp = 8 kV.
Data for other conditions on request.
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
August 2009
Page 3 of 7
Film Capacitors – Power Factor Correction
Key Components – Capacitor Contactors
B44066S….J230/J110/N230
B44066S
Preliminary data
Type/
Auxiliary contacts
Normal Open (NO)
Rated insulation
voltage
Rated operational
current AC15 at
230 V / 400 V
Rated operational
current AC1 at
690 V
1)
…1810…
…2410…
…3210…
…5010…
…6210…
…7410…
…9910…
1
1
1
1
1
1
1
V AC
6901)
6901)
6901)
6901)
6901)
6901)
6901)
A
3/2
3/2
3/2
3/2
3/2
3/2
3/2
A
10
10
10
10
10
10
10
Suitable at 690 V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Vimp = 8 kV.
Data for other conditions on request.
Connection diagram for all types B44066S…J…
Connection diagram for all types B44066S…N…
(with preload resistors). (B44066S1810J230 and
B44066S1810J110 with wires on the bottom only,
B44066S9910J230 with resistors inside housing).
(without preload resistors).
Dimensional drawings
B44066S1810J230, B44066S1810J110
45
B44066S1810N230
98
35-36
94
59
85
49-50
ø5
M3.5
6.5
50
KLK1719-4
B44066S2410J230, B44066S3210J230
B44066S2410N230, B44066S3210N230
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
August 2009
Page 4 of 7
Film Capacitors – Power Factor Correction
Key Components – Capacitor Contactors
B44066S….J230/J110/N230
B44066S
Preliminary data
B44066S2410J110, B44066S3210J110
B44066S5010J230,
B44066S6210J230, B44066S6210J110,
B44066S7410J230, B44066S7410J110
B44066S5010N230, B44066S6210N230
B44066S7410N230
B44066S9910J230
B44066S9910N230
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
August 2009
Page 5 of 7
Film Capacitors – Power Factor Correction
Key Components – Capacitor Contactors
B44066S….J230/J110/N230
B44066S
Preliminary data
Cautions and warnings
In case auxiliary contacts are used for switching of discharge resistors (not in accordance with IEC
60831 standard), make sure that the current of the discharge resistors is not higher than the rated
current of the auxiliary contacts.
Mounting instructions
In the area of capacitor switching contactors, difficultly inflammable and self-extinguishing materials may be
used only, because abnormal temperatures within the area of the resistance spirals cannot be excluded.
Note
For detailed information about PFC key components and cautions, refer to the latest version of
EPCOS PFC Product Profile.
Important: Please note that the „General Safety Recommendations for Power Capacitors“ by ZVEI
(German Electrical and Electronic Manufacturers´ Association (ZVEI) have to be observed in addition
to the caution guidelines stated in the data sheet (Internet: www.epcos.com/pfc).
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
August 2009
Page 6 of 7
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As a
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or failure
before the end of their usual service life cannot be completely ruled out in the current state
of the art, even if they are operated as specified. In customer applications requiring a very high
level of operational safety and especially in customer applications in which the malfunction or
failure of an electronic component could endanger human life or health (e.g. in accident
prevention or life-saving systems), it must therefore be ensured by means of suitable design of the
customer application or other action taken by the customer (e.g. installation of protective circuitry
or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or
failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material
Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed
questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently,
we cannot guarantee that all products named in this publication will always be available.
The aforementioned does not apply in the case of individual agreements deviating from the
foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of
the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, BAOKE, AgriCap, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DSSP,
MiniBlue, MiniCell, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap,
SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K,
ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries.
Further information will be found on the Internet at www.epcos.com/trademarks.