Switching Spark Gap CAS02X-070 Ordering code: B88069X0700T502 DC spark-over voltage 1) 2) 200 ... 250 V ≤ 300 ms 1 000 000 Ignitions 350 15 150 2 60 V kΩ nF µH A Insulation resistance at 100 Vdc > 0.1 GΩ Capacitance at 1 MHz <2 pF Weight ~ 1.5 g Operation and storage temperature -20 ... +125 °C Climatic category (IEC 60068-1) 20/ 125/ 21 Initial values Ignition time tI after 150 hours in darkness 3) at –20; +25; +125 °C Electrical life time Switching operations (cycle: 1 s on; 10 s off) at –20; +25; +125°C Test circuit parameters Open circuit voltage V0' Loading resistance R Discharge capacitance C Inductance L Discharge peak current IP Marking, red CS 230 YYMM O CS 230 YY MM O 1) 2) 3) - Series - Nominal voltage - Year of production - Month of production - Non radioactive At delivery AQL 0.65 level II, DIN ISO 2859 In ionized mode, after load Time from capacitor charged to the first high voltage spark Test circuit: Vac = 350 V; R = 15 kΩ; C = 150 nF AB E / AB PM Issue 06, 10.02.2004 Page 1 of 2 Switching Spark Gap CAS02X-070 Ordering code: B88069X0700T502 Not to scale Dimensions in mm Non controlled document EPCOS AG 2002. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed. AB E / AB PM Issue 06, 10.02.2004 Page 2 of 2