EPCOS B88069X4051T902

Surge Arrester
3-Electrode-Arrester
T90-A90XFSMD
Ordering code: B88069X4051T902
DC spark-over voltage 1) 2) 4)
90
± 20
V
%
Impulse spark-over voltage 4)
at 100 V/µs - for 99 % of measured values 6)
- typical values of distribution 6)
< 550
< 450
V
V
- for 99 % of measured values 6)
- typical values of distribution 6)
< 700
< 600
V
V
Nominal impulse discharge current (wave 8/20 µs) 5) 6)
5
kA
Nominal alternating discharge current (50 Hz, 1 s) 5) 6)
5
A
Insulation resistance at 50 Vdc 4)
>1
GΩ
Capacitance at 1 MHz 4)
< 1.5
pF
Transverse delay time 3)
< 0.2
µs
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 10
~1
~ 60
V
A
V
Weight
~ 0.8
g
Storage temperature
-40 ... +90
°C
Climatic category (IEC 60068-1)
40/ 90/ 21
at 1 kV/µs
Marking, blue
90 YY O
90
YY
O
- Nominal voltage
- Year of production
- Non radioactive
1)
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
3)
Test according to ITU-T Rec. K.12
4)
Tip or ring electrode to center electrode
5)
Total current through center electrode, half value through
tip respectively ring electrode.
6)
under test
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
2)
The arrester failsafe mechanism contains a insulating foil with a melting
temperature of 260 °C.
The arrester failsafe works at temperatures > 260 °C. The arrester has to be
fixed mechanically, if the arrester is contacted by soldering and if the solder
temperature is less than 260 °C.
AB E / AB PM
Issue 01, 15.07.2004
Page 1 of 2
Surge Arrester
3-Electrode-Arrester
T90-A90XFSMD
Ordering code: B88069X4051T902
Not to scale
Dimensions in mm
Non controlled document
SMD-Gurtverpackung nach IEC 60286-3 /
Tape and reel packing comply with the specification of IEC 60286-3
 EPCOS AG 2002. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and
Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless
otherwise agreed.
AB E / AB PM
Issue 01, 15.07.2004
Page 2 of 2