HRS RP34L-5PA-3SC

The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
Low Profile Connectors for AC power supply
RP34L Series
Receptacle installed height
(3 pos.type)
(2 pos.type)
RP34L
■Features
Existing RP34
Mated dimensions
1. Low profile
Receptacles are designed with their installation heights to be
shorter than those of conventional RP34 series.
2. Space saving
Both 2 and 3 position receptacles are miniaturized to 7mm
length, resulting in a small board mounting area.
3. Snap-lock mechanism
Audible click when connector is fully mated.
4. Precise mated connection
RP34L-5PA-2SC(✽✽✽✽) & RP34L-5R-2PD
Secure hold of the plug on au 3 axis.
5. Sequence mating
The 3 contact type has sequenced mating. One pin makes
contact as a ground terminal before the other contacts.
6. No Mismating
This 2 contact plug is an over-molded (i.e., cable-integrated form) type.
Recommended cable diameter is 3.5mm dia.
Mated dimensions
Two polarized keys prevent any insertion error.
23.5
16.9
9.1
An arrow on the top of the plug shows the proper direction for
insertion.
10.45
7. Ease of Mating
■Applications
7
1.4
5
7.8
Notebook PCs, portable remote terminals, AV equipment, etc.
RP34L-5PA-3SC & RP34L-5R-3PD
This 3-contact plug is a field assembly type.
Recommended cable diameter is 4mm dia.
2006.8
1
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
■Product Specifications
Ratings
Current rating
5A
Operating temp. range
-25ç~+85ç
Voltage rating
30V AC, 42A DC
Storage temp. range
-10ç~+60ç
Item
Specification
1.Contact resistance
Conditions
1A DC
30mø or max.
2.Insulation resistance 1000mø min.
100V DC
3.Withstanding voltage No flashover or insulation breakdown
150V AC/1 minute
4.Vibration
No electric disconnection of 10µs or more
10~55Hz, one-sided amplitude 0.75mm, 3 directions for 2hours, respectively
5.Temperature cycle
Insulation resistance:100mø min.
-55ç for 30 min./normal temp. for 10~15 min./+85ç
for 30 min./normal temp. for 10~15 min. 5 cycles
6.Salt spray
No corrosions
5% salt water solution, 48 hours
7.Durability
Contact resistance:60mø max.
5,000 mating / un-mating
■Material
Component
2 pos.
2 pos.
3 pos.
Material
Phosphor bronze
Solder-plating
Insulator
Nylon
Black
Contacts
Brass
Palladium-plating
UL94HB
---------------
Cover
Vinyl chloride
Black
UL94V-0
Insulator
Nylon
Black
Contacts
Phosphor bronze
UL94HB
---------------
Metal comp.
Phosphor bronze
Solder-plating
---------------
Insulator
PPS
Black
Contacts
Brass
Palladium-plating
UL94V-0
---------------
Polycarbonate
Black
UL94V-0
Vinyl chloride
Black
UL94V-0
Insulator
PPS
Black
Contacts
Phosphor bronze
Palladium-plating
UL94V-0
---------------
■Ordering information
RP34L - 5 PA - 2 SC
1
1 Series name: RP34L
2 Shell: Shell.size, 5
3 Type:
2
3
4
(✽ ✽ ✽ ✽ )
5
6
4 Number of contacts:
2, 3
5 Type of contact:
Receptacle: R
PD: through hole male contact
Assembled straight plug: P
SC: crimp female contact
Assembled right angle plug: LP
Cable ass'y, straight plug: PA
6 Cable length:(✽✽✽✽) depends on
each cable (mm).
2
Remarks
---------------
Metal comp.
Cover
3 pos.
Finish / Color
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
■Receptacles
●2 pos.
RP34L-5R-2PD(71)
Recommended panel cutout
PCB mounting pattern
Connector front
●3 pos.
RP34L-5R-3PD(71)
Recommended panel cutout
PCB mounting pattern
Connector front
Part Number
CL No.
RP34L-5R-2PD(71)
RP34L-5R-3PD(71)
113-5154-6-71
113-5157-4-71
RoHS
YES
3
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
■Plugs
Cable assembly
■RP34L-5PA-2SC(1857)(71)
4
■RP34L-5PA-3SC(71)
Field assembly-Straight
■RP34L-5LP-3SC(71)
Field assembly-Right angle
Part Number
CL No.
RP34L-5PA-2SC(1857)(71)
RP34L-5PA-3SC(71)
113-5153-3-71
RP34L-5LP-3SC(71)
113-5161-1-71
113-5178-4-71
RoHS
YES
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
■Crimp contact
■RP34L-SC1-212(01)
Part Number
CL No.
RoHS
RP34L-SC1-212(01)
113-5151-8-01
YES
■Applicable Tools
Type
Part Number
CL No.
Applicable contact
Applicable conductor
Manual crimping tool
HT-102/RP34L-SC1-212
--------------
RP34L-SC1-112(01)
AWG#18~#22
CM-105
901-0005-4
--------------
--------------
AP105-RP34L-SC1-212
901-2043-4
RP34L-SC1-212(01)
AWG#18~#22
Cable crimping tool
RP34-TC-01
150-0074-1
--------------
Drawing tool
RP6-SC-TP
150-0039-0
--------------
Automatic
Crimper
Crimper body
Ø4
--------------
5
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
■Assembly Instructions(3-Position Plug)
●Straight Plug
1. Slide the bushing over the cable.
2. Prepare the cable end and the conductors as shown.
3. Crimp the contacts to each conductor.
Verify the crimp dimensions.
4. Insert each of the contacts into the insulator body.
Verify that the contact is secure by slightly pulling
on the conductor. Should the contacts require reinsertion, use the tool RP6-SC-TP to remove them
(Inserted from the termination side).
5. Crimp the cable clamp over the cable at designated
dimension (Tool number:RP34-TC-01).
6. Place the outer case on a flat surface , with inside facing up.
7. Carefully place the insulator body, clamp and the bushing
into corresponding indents and cut-outs in the outer case.
Verify correct location. (As shown on drawing)
Note A: When placing all components in the case,
exercise caution as NOT to damage any of the
protruding snap.
Note B: All components should fit easily, without use of
any force.
8. Carefully align the other outer case over all
components case. Do not force alignment.
9. Snap the case in place.
Outer case
Outer case
Outer case
Outer case
●Right Angle Plug
Insulator body
Outer case
Insulator body
6
1. The right angle plug can also be assembled by
using the same procedure as the straight plug.
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
■Precautions
1. Use the connector section with its panel held down so as not to have excessive load.For 2-contact type, hold the
outer shellsection of the receptacle, and for 3 contact type, the outer shell section of the plug.
Panel
<2-contact type>
<3-contact type>
2. After connector assembly, cable must not be pulled over 30N in the arrow-indicated direction. Be careful not to add
excessive tensile load because it will lead the damage of connectors.
7