OMRON 3S4YR-MVFW1JDH-074

®
Motor Driven Card Reader/Writer
3S4YR-MVF/MVS
Reliably Handles Read/Write Functions
for both Magnetic and IC Cards
■
■
■
■
■
■
■
Downloadable firmware for specification
updates, customer requirements,
firmware updates, new smart card support
Powerful all-roller card feeding system easily
handles warped and/or wet cards
Highly reliable reading/writing of all three
tracks using new pick-up encoder technology
Fully-integrated RS-232C eliminates the
need for IC adapter boards
User-friendly interface with multifunction
commands and support for T=0 and T=1, EMV
Compact size and light weight for
easy installation
Locking shutter for fraud prevention
Ordering Information
Magnetic Tracks Supported (R, R/W) IC
1
2
3
Center JIS II Contact
Interface
Built-in Card
(see note 3) Shutter Ejection
R/W
R/W
R/W
—
—
No
RS-232
Yes
Front/Rear Black
—
3S4YR-MVFW1D-052
R/W
R/W
R/W
—
—
ISO 7816 RS-232
Yes
Front/Rear Black
—
3S4YR-MVFW1JD-051L
Yes
Front/Rear Black Memory card
3S4YR-MVFW1JD-M51L
support (see note1)
Color Notes
Part Number (see note 2)
R/W
R/W
R/W
—
—
ISO 7816 RS-232
R/W
R/W
R/W
—
—
ISO 7816 RS-232
Yes
Front/Rear Black HiCo
3S4YR-MVFW1JDH-074
R/W
R/W
R/W
—
—
No
RS-232
Yes
Front/Rear Black
R/W
R/W
R/W
—
—
ISO 7816 RS-232
Yes
Front/Rear Black Housing
3S4YR-MVS1D
(MVFW1D-052 Core)
3S4YR-MVS1JD
(MVFW1JD-051L Core)
—
Note 1: Inquire regarding specific memory card support.
2: Models with support for SAM modules are available. Please contact Omron for details.
3: Please contact Omron for details concerning USB interface availability.
■ TYPICAL APPLICATIONS
• Cash Dispensers
• Automatic Teller Machines (ATM)
• POS Terminals
• Credit Card Checkers
• ID Card Checkers
• Electronic Lock System
• Medical Patient System
• Health Control System
•Teller Terminal
• Front desk card encoders
3S4YR-MVF/MVS
3S4YR-MVF/MVS
Specifications
Part number
Recommended card
type
3S4YR-MVF
3S4YR-MVS
Magnetic card
ISO 7810, 7811/1-5, 7812, 7813. Please inquire if using high-coercivity cards.
IC card (see Note 1)
ISO 7816/1-4 (T=0 and/or T=1)
Recording method
FM decoding (F2F)
Card feeding speed
20 cm/sec (8 in/sec) in normal operation; 5 cm/sec (2 in/sec) IC card handling
Location of magnetic stripe
Installation
Motor type
DC motor
Service life (see note 2)
At bottom
Entire unit
1,500,000 passes or 5 years, whichever comes first
IC contact
300,000 times
Operating power supply
24 VDC ± 10%
Current consumption
2.0 A or less when motor revolution starts; 500 mA in standby mode
Mounting location
Indoors — away from wind, rain, and sunlight
5° to 55°C (41° to 131°F)
0° to 40° C (32° to 104°F)
Storage
-25° to 55°C (-13° to 131°F)
-25° to 55° C (-13° to 131°F)
Operation
5% to 85% RH, no condensation
35% to 85% RH, no condensation (see note 3)
Storage
5% to 90% RH, no condensation
5% to 90% RH, no condensation (see note 3)
Ambient temperature Operation
Ambient humidity
100 VAC to 240 VAC (± 10%)
Vibration
10 to 150 Hz and single vibration width of 0.15 mm or
an acceleration of 2 G (19.6 m/sec2), whichever is smaller
Shock
20 G in six directions (up and down, left and right, forward and back,
3 times in each direction)
Dimensions (with shutter)
210L x 124W x 90H mm
(8.27L x 4.88W x 3.54H in)
271L x 130W x 154H mm
(10.67L x 5.12W x 6.06H in)
Weight
Approx. 2 kg (4.41 lbs)
Approx. 4.5 kg (9.92 lbs.) without attachment
Note 1: Please request confirmation on specific IC card compatibility, including EMV (Europay / Mastercard / Visa) and memory cards.
2: One pass denotes one round trip.
3: Absolute air humidity in operation is 23 g/m3 or less. In storage, absolute air humidity is 40 g/m3 or less.
Engineering Data
■ I/O INFORMATION
RS-232C Interface automatically recognizes data transmission speeds of 1200, 2400, 4800, 9600, and 19200 baud.
3S4YR-MVFW1JD RS-232C Interface
3S4YR-MVFW1JD Power Interface
Card reader side:
JAE 9-pin D-Sub socket, DELC-J9SAF-10L9.
Card reader side:
Molex 4 node, 2.54 mm pitch in serial 5046-04A.
Pin #
Signal
Input/Output
Description
Pin #
Signal
Input/Output
1
NC
—
Not connected
1
+24V
—
Power supply
2
RXD
Input
Receive data
2
GND
—
Power ground
3
TXD
Output
Transmit data
3
XGND
—
Secondary power ground
4
DTR
Output
Data terminal ready
4
X24V
—
Secondary supply
5
GND
—
Ground
6
NC
—
Not connected
7
NC
—
Not connected
8
CTS
Input
Clear to send
9
NC
—
Not connected
2
Description
3S4YR-MVF/MVS
3S4YR-MVF/MVS
Dimensions
Unit: mm (inch)
■ 3S4YR-MVF with shutter
(Also available without shutter.)
210 (8.27)
86 (3.39)
124
(4.88)
25 (0.98) min.
57 (2.24)
57
(2.24) 44
(1.73)
78
(3.07)
31.6
62
(1.24)
(2.44)
57
(2.24)
70.2
(2.76)
4-3.5 x 6
Elongated Hole
86 (3.39)
47
(1.85)
2.1 (0.08)
17 (0.67)
26 (1.02)
90
(3.54)
12 (0.47)
45 (1.77)
8 (0.31)
4 (0.16)
Interface Connector
PCB
86 (3.39)
57 (2.24)
62
(2.44)
57
(2.24)
124
(4.88)
2-M3
2-M3
57
(2.24)
86 (3.39)
47
(1.85)
210 (8.27)
3
3S4YR-MVF/MVS
3S4YR-MVF/MVS
■ 3S4YR-MVS
Unit: mm (inch)
Bottom
Top
70
(2.76)
271.5
(10.69)
144.1 (5.67)
POWER
READY
130 (5.12)
RUN
ERROR
Bottom
Top
9.9 (0.39)
97.2 (3.83)
154 (6.06)
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
R
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
1-800-55-OMRON
416-286-6465
One East Commerce Drive
Schaumburg, IL 60173
Cat. No. GC CR3
7/00
885 Milner Avenue
Scarborough, Ontario M1B 5V8
Specifications subject to change without notice.
4