OMRON G6Z-1P-A

High-frequency Relay
G6Z
Miniature 2.6-GHz-Band, SPDT,
High-frequency Relay
• Superior high-frequency characteristics include an isolation
of 30 dB min., insertion loss of 0.5 dB max., and V.S.W.R.
of 1.5 max. at 2.6 GHz.
• Triplate micro stripline technology assures superior
high-frequency characteristics.
• Miniature dimensions of 20 x 8.6 x 8.9 mm (L x W x H).
• E-shape or Y-shape terminal options with reverse contact
arrangements available, allows greater freedom with PCB
design.
• Choose between 75-Ω or 50-Ω impedance models
• RoHS Compliant.
Ordering Information
Classification
Non-latching
Structure Contact
Terminal
form
arrangement
Fully
sealed
SPDT
E-shape
Y-shape
Single coil
latching
E-shape
Y-shape
Dual coil
latching
E-shape
Y-shape
Characteristic
impedance
75 Ω
Rated coil voltage
Model
Through-hole
3, 4.5, 5, 9, 12, and 24 VDC G6Z-1PE
Surface Mount
G6Z-1FE
50 Ω
G6Z-1PE-A
75 Ω
G6Z-1P
G6Z-1F
50 Ω
G6Z-1P-A
G6Z-1F-A
G6Z-1FE-A
75 Ω
G6ZU-1PE
G6ZU-1FE
50 Ω
G6ZU-1PE-A
G6ZU-1FE-A
G6ZU-1F
75 Ω
G6ZU-1P
50 Ω
G6ZU-1P-A
G6ZU-1F-A
75 Ω
G6ZK-1PE
G6ZK-1FE
50 Ω
G6ZK-1PE-A
G6ZK-1FE-A
75 Ω
G6ZK-1P
G6ZK-1F
50 Ω
G6ZK-1P-A
G6ZK-1F-A
Notes: 1. When ordering, add the rated coil voltage to the model number.
Example: G6Z-1PE-A-DC12
Rated coil voltage
2. When ordering tape packing (surface mount models), add "-TR" to the model number.
Example: G6ZU-1FE-TR-DC12
Tape packing
"-TR" is not part of the relay model number. Therefore, it is not marked on the relay case.
Model Number Legend:
G6Z
1
2 3 4
- DC
5 6
7
1. Relay Function
None: Non-latching
U:
Single coil latching
K:
Dual coil latching
4. Terminal Structure
None: Y-shape terminal
E:
E-shape terminal
6. Contact arrangement
None: Standard contact arrangement
R:
Reverse contact arrangement
2. Contact Form
1:
SPDT
5. Characteristic Impedance
None: 75 Ω
A:
50 Ω
7. Rated Coil Voltage
3, 4.5, 5, 9, 12, 24
3. Terminal Shape
F: Surface mount terminals
P: PCB through-hole terminals
High-frequency Relay
G6Z
341
Application Examples
These Relays can be used for switching signals in media equipment.
• Wire communications:
Cable TV (STB and broadcasting infrastructure), cable modems, and VRS (video response systems)
• Wireless communications:
Transceivers, ham radios, ETC, ITS, high-level TV, satellite broadcasting, text multiplex broadcasting, mobile phone
stations, TV broadcasting facilities, community antenna systems and car navigation systems
• Entertainment equipment:
TVs, video games, satellite radio units,
• Industrial equipment:
Measuring equipment, test equipment, and multiplex transmission devices
Specifications
■ Contact Ratings
Load type
Resistive load
Contact Material
Au clad Cu alloy
Rated load
10 mA at 30 VAC; 10 mA at 30 VDC; 10 W at 900 MHz (See note)
Rated carry current
0.5 A
Max. switching voltage
30 VAC, 30 VDC
Max. switching current
0.5 A
Note: This value is for an impedance of 50 Ω or 75 Ω with a V.S.W.R. of 1.2 max.
■ High-frequency Characteristics
Frequency
Terminal type
900 MHz
Through hole
Terminal structure
E-shape
75 Ω
65 dB min.
50 Ω
60 dB min.
Isolation
Insertion loss (not
75 Ω
including substrate loss)
50 Ω
V.S.W.R.
Return loss
Y-shape
2.6 GHz
Surface mount
E-shape
Y-shape
60 dB min.
E-shape
0.5 dB max.
0.1 dB max.
0.3 dB max.
75 Ω
1.2 max.
1.5 max.
50 Ω
1.1 max.
1.3 max.
75 Ω
20.8 dB max.
14.0 dB max.
50 Ω
26.4 dB max.
17.7 dB max.
10 W (See note 2)
Maximum switching power
10 W (See note 2)
Note: 1. The above values are initial values.
2. These values are for an impedance of 50 Ω or 75 Ω with a V.S.W.R. of 1.2 max.
High-frequency Relay
G6Z
Y-shape
Surface mount
E-shape
Y-shape
35 dB min. 45 dB min. 30 dB min. 40 dB min.
0.2 dB max.
Maximum carry power
342
Through hole
■ Coil Ratings
Non-latching, Standard and Reverse-contact Models G6Z-1P(E), G6Z-1F(E)
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
3
66.7
45
4.5
44.4
101
5
40.0
125
9
22.2
405
12
16.7
720
24
8.3
2,880
Must operate
voltage
(VDC)
75% max. of
rated voltage
Must dropout
voltage
(VDC)
10% min. of
rated voltage
Maximum
voltage
(VDC)
150% of rated
voltage
Power
consumption
(mW)
Approx. 200
Single Coil Latching Models G6ZU-1P(E), G6ZU-1F(E)
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
3
66.7
45
4.5
44.4
101
5
40.0
125
9
22.2
405
12
16.7
720
24
8.3
2,880
Must set
voltage
(VDC)
75% max. of
rated voltage
Must reset
voltage
(VDC)
75% max. of
rated voltage
Maximum
voltage
(VDC)
150% of rated
voltage
Power
consumption
(mW)
Approx. 200
Dual Coil Latching Models G6ZK-1P(E), G6ZK-1F(E)
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
3
120
25
4.5
80
56
5
72
69
9
40
225
12
30
400
24
15
1,600
Note: 1.
2.
3.
4.
Must set
voltage
(VDC)
75% max. of
rated voltage
Must reset
voltage
(VDC)
75% max. of
rated voltage
Maximum
voltage
(VDC)
150% of rated
voltage
Power
consumption
(mW)
Approx. 360
The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
The operating characteristics are measured at a coil temperature of 23°C.
The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.
The voltage measurements for operate/release and set/reset are the values obtained for instantaneous changes in the voltage
(rectangular wave).
High-frequency Relay
G6Z
343
Characteristics
Item
Non-latching
models
Single coil latching
models
Dual coil latching
models
G6Z-1P(E), G6Z-1F(E)
G6ZU-1P(E), G6ZU-1F(E)
G6ZK-1P(E), G6ZK-1F(E)
Contact resistance (See note 2)
100 mΩ max.
Operating (set) time (See note 3)
10 ms max. (approx. 3.5 ms) 10 ms max. (approx. 2.5 ms)
Release (reset) time (See note 3)
10 ms max. (approx 2.5 ms)
Set/reset time
---
Insulation resistance (See note 4)
100 MΩ min. (at 500 VDC)
Dielectric strength
Coil and contacts
1,000 VAC, 50/60 Hz for 1 min.
Coil and ground,
contacts and ground
500 VAC, 50/60 Hz for 1 min.
Contacts of same
polarity
500 VAC, 50/60 Hz for 1 min.
Mechanical durability
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction durability
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Mechanical durability
1,000 m/s2
Malfunction durability
500 m/s2
Service life
Mechanical
1,000,000 operations min. (at 36,000 operations/hour)
Electrical
300,000 operations min. (30 VAC, 10 mA/30 VDC, 10 mA), 100,000 operations min.
(900 MHz, 10 W) at a switching frequency of 1,800 operations/hour
Vibration resistance
12 ms
Ambient temperature
Operating: -40°C to 70°C (with no icing or condensation)
Ambient humidity
Operating: 5% to 85% RH
Weight
Approx. 2.8 g
Note: 1.
2.
3.
4.
The above values are initial values.
The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
Values in parentheses are typical values.
The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking the
dielectric strength.
Engineering Data
Ambient Temperature vs. Must
Operate or Must Release Voltage
250
On the basis of rated voltage (%)
Maximum voltage (%)
Ambient Temperature vs.
Maximum Voltage
200
G6Z
G6ZU
150
G6ZK
100
Y
100
Sample: G6Z-1P 5 VDC
90 Number of relays: 5
1,000
Max. estimated value
80
max.
70
avg.
min.
60
200
max.
avg.
min.
Must operate voltage
20
40
60
80
0
−60
100
Ambient temperature (°C)
344
High-frequency Relay
G6Z
−40
−20
0
20
40
60
80 100
Ambient temperature (°C)
400
1,000
Z'
Z'
Y'
1,000
X'
600
Shock direction
X
X'
Y
Z
Must release voltage
0
Z
1,000
200
40
20
−20
600 Not
energized
400
X
1,000
50
10
0
−40
Energized
800
30
50
Shock Malfunction
800
1,000
Y'
m/s2
G6Z-1P-A 50 Ω
5 VDC
Number of relays: 5
Unit:
Sample:
Conditions: Shock is applied in ±X, ±Y, and ±Z
directions three times each with and
without energizing the Relays to check
for contact malfunctions.
Electrical Endurance (with Must
Operate and Must Release Voltage)
100
On the basis of rated voltage (%)
On the basis of rated voltage (%)
Electrical Endurance (with Must
Operate and Must Release Voltage)
Sample: G6Z-1PE 75 Ω 5 VDC
Number of Relays: 5
Test conditions: 10 mA resistive load at 30 VAC
80 Switching frequency: 1,800 operations/h
Must operate
max.
60
min.
40
100
Sample: G6Z-1PE 75 Ω 5 VDC
Number of Relays: 5
Test conditions: 10 mA resistive load at 30 VDC
80 Switching frequency: 1,800 operations/h
Must operate
max.
min.
60
40
Must release
Must release
max.
max.
20
20
min.
min.
0
0.0001 0.001
0.01
0.1
1
10
0
0.0001 0.001
100
0.01
Operating frequency (×103 operations)
1,000
Sample: G6Z-1PE 75 Ω 5 VDC
700 Number of Relays: 5
500 Test conditions: 10 mA resistive load
at 30 VAC
Switching frequency: 1,800 operations/h
300
NO
contact
NC
contact
100
1,000
Sample: G6Z-1PE 75 Ω 5 VDC
700 Number of Relays: 5
500 Test conditions: 10 mA resistive load
at 30 VDC
Switching frequency: 1,800 operations/h
300
50
70 Contact resistance
50
max.
max.
min.
min.
30
0.1
1
10
Operating frequency
10
0.001 0.01
100 1,000
(×103
1
0
−10
(Average value)
−20
Sample: G6Z-1P 5 VDC
Number of Relays: 5
−800
−400
Must operate voltage
Must release voltage
0
400
800 1,200
External magnetic field (A/m)
100 1,000
+30
S
N
+20
+10
0
−10
−20
Sample: G6Z-1P 5 VDC
Number of Relays: 5
−30
−1,200
−800
−400
(Average value)
Change rate on the basis of initial value (%)
+10
10
Operating frequency (×103 operations)
Change rate on the basis of initial value (%)
Change rate on the basis of initial value (%)
N
+20
NO
contact
NC
contact
min.
min.
0.1
operations)
+30
−30
−1,200
100
30
External Magnetic Interference
(Average value)
S
10
max.
max.
100
Contact resistance
70
10
0.001 0.01
1
Electrical Endurance
(Contact Resistance)
Contact resistance (mΩ)
Contact resistance (mΩ)
Electrical Endurance
(Contact Resistance)
0.1
Operating frequency (×103 operations)
Must operate voltage
Must release voltage
0
400
800 1,200
External magnetic field (A/m)
+30
S
N
+20
+10
0
−10
−20
Sample: G6Z-1P 5 VDC
Number of Relays: 5
−30
−1,200 −800
−400
0
Must operate voltage
Must release voltage
400
800 1,200
External magnetic field (A/m)
Note: 1. The tests were conducted at an ambient temperature of 23°C.
2. The contact resistance data are periodically measured reference values and are not values from monitoring each operation. Contact
resistance values will vary according to the switching frequency and operating environment, so be sure to check operation under the
actual operating conditions before use.
High-frequency Relay
G6Z
345
High-frequency Characteristics at 75 Ω
(Insertion Loss)
(Average value (initial value))
Sample: G6Z-1PE 75 Ω 5 VDC
with terminating resistance
20
Return loss (dB)
(Average value (initial value))
Insertion loss (dB)
Isolation (dB)
(Average value (initial value))
0
High-frequency Characteristics at 75 Ω
(Return Loss, V.S.W.R.)
0
0.2
40
0.4
60
0.6
0
1.7
Sample: G6Z-1PE 75 Ω 5 VDC
with terminating resistance
10
1.6
Return loss
20
1.5
30
1.4
40
V.S.W.R.
High-frequency Characteristics at 75 Ω
(Isolation)
1.3
V.S.W.R.
50
100
0.8
N.O.
N.C.
0
500
1,000
1,500
2,000
1.0
2,500 3,000
Sample: G6Z-1PE 75 Ω 5 VDC
with terminating resistance
500
1,000
1,500
Frequency (MHz)
70
2,500 3,000
High-frequency Characteristics at 50 Ω
(Insertion Loss)
(Average value (initial value))
0
500
1,000
1,500
20
0
0.2
1
2,500 3,000
High-frequency Characteristics at 50 Ω
(Return Loss, V.S.W.R.)
(Average value (initial value))
Return loss (dB)
Sample: G6Z-1PE-A 50 Ω 5 VDC
with terminating resistance
2,000
Frequency (MHz)
(Average value (initial value))
Insertion loss (dB)
Isolation (dB)
2,000
1.1
N.O.
N.C.
Frequency (MHz)
High-frequency Characteristics at 50 Ω
(Isolation)
0
60
N.O
N.O.
N.C
N.C.
* Substrate loss removed
0
1.2
0
1.7
Sample: G6Z-1PE-A 50 Ω 5 VDC
with terminating resistance
10
1.6
20
1.5
Return loss
40
0.4
60
0.6
80
0.8
30
1.4
40
1.3
50
100
N.O.
N.C.
0
500
1,000
1,500
2,000
1.0
2,500 3,000
Sample: G6Z-1PE-A 50 Ω 5 VDC
with terminating resistance
* Substrate loss removed
0
500
1,000
1,500
2,000
60
N.O.
N.C.
2,500 3,000
Frequency (MHz)
70
1.1
N.O.
N.C.
0
500
1,000
1,500
2,000
1
2,500 3,000
Frequency (MHz)
Must Operate and Must Release
Bounce Time Distribution (See note.)
25
Number of contacts
Number of contacts
1.2
V.S.W.R.
Frequency (MHz)
Must Operate and Must Release
Time Distribution (See note.)
V.S.W.R.
80
Must operate
Must release time
20
Sample: G6Z-1P
75 Ω 5 VDC
Number of Relays: 32
30
Must operate bounce time
Must release bounce time
25
Sample: G6Z-1P
75 Ω 5 VDC
Number of Relays: 32
20
15
15
10
10
5
0
5
1.0
2.0
3.0
4.0
5.0
0
Time (ms)
0.5
1.0
1.5
2.0
Time (ms)
Note: 1. The tests were conducted at an ambient temperature of 23°C.
2. High-frequency characteristics depend upon the PCB to which the relay is mounted. Always check these characteristics, including
endurance (service life), in the actual machine before use.
346
High-frequency Relay
G6Z
Dimensions
Note: All units are in millimeters unless otherwise indicated.
■ PCB Through-hole Terminal Types
Mounting Dimensions (Bottom View)
Tolerance: ±0.1 mm
G6Z-1PE
G6Z-1PE-R
G6ZU-1PE
Terminal Arrangement/Internal
Connections (Bottom View)
G6Z-1PE
Six, 1.8-dia.
Orientation mark
1
7
−
Six, 1.0-dia. holes
7.62
20
8.6
+
Three, 1.6-dia.
Three, 0.8-dia. holes
2.54
14
13 12 11
10 9
8
7.62
15.24
G6Z-1PE-R
Orientation mark
1
8.9
7
−
+
3
6-0.6
2.54
3-0.4
7.62
0.2
(Coil
terminal)
0.18
14
7.62
13 12 11
15.24
10 9
8
G6ZU-1PE
Orientation mark
1
Note: Each value has a tolerance of ±0.3 mm.
7
S −
R +
14
Mounting Dimensions (Bottom View)
Tolerance: ±0.1 mm
G6Z-1PE-A
G6ZU-1PE-A
+
−
13 12 11
10 9
8
Terminal Arrangement/Internal
Connections (Bottom View)
G6Z-1PE-A
Nine, 1.8-dia.
Orientation mark
1
7
−
Nine, 1.0-dia. holes
+
7.62
20
14
8.6
13 12 11
10 9
8
2.54
7.62
15.24
G6ZU-1PE-A
8.9
Orientation mark
1
3
9-0.6
2.54
7.62
15.24
0.2
(Coil
terminal)
7
S −
R +
0.18
+
−
7.62
14
13 12 11
10 9
8
Note: Each value has a tolerance of ±0.3 mm.
High-frequency Relay
G6Z
347
Mounting Dimensions (Bottom View)
Tolerance: ±0.1 mm
G6Z-1P
G6ZU-1P
Terminal Arrangement/Internal
Connections (Bottom View)
G6Z-1P
Eight, 1.8-dia.
Orientation mark
1
3 4
−
Eight, 1.0-dia. holes
7.62
20
8.6
5
7
10 9
8
5
7
10 9
8
+
Three, 1.6-dia.
Three, 0.8-dia. holes
2.54
14
13 12
7.62
15.24
G6ZU-1P
8.9
Orientation mark
1
3
8-0.6
2.54
0.2
(Coil
terminal)
3-0.4
7.62
3 4
S −
R +
0.18
+
−
7.62
14
13 12
15.24
Note: Each value has a tolerance of ±0.3 mm.
Mounting Dimensions (Bottom View)
Tolerance: ±0.1 mm
G6Z-1P-A
G6ZU-1P-A
Terminal Arrangement/Internal
Connections (Bottom View)
G6Z-1P-A
Eleven, 1.8-dia.
Orientation mark
1
3 4
−
Eleven, 1.0-dia. holes
5
7
10 9
8
+
7.62
20
14
8.6
13 12
2.54
7.62
15.24
G6ZU-1P-A
8.9
Orientation mark
1
3
2.54
11-0.6
7.62
15.24
0.2
(Coil
terminal)
3 4
S −
R +
0.18
5
7
10 9
8
+
−
7.62
14
13 12
Note: Each value has a tolerance of ±0.3 mm.
Mounting Dimensions (Bottom View)
Tolerance: ±0.1 mm
G6ZK-1PE
Seven, 1.8-dia.
Terminal Arrangement/Internal
Connections (Bottom View)
Orientation mark
1
Seven, 1.0-dia. holes
7.62
20
8.6
Three, 0.8-dia. holes
7.62
15.24
8.9
3
7-0.6
2.54
3-0.4
7.62
0.2
(Coil
terminal)
0.18
7.62
15.24
Note: Each value has a tolerance of ±0.3 mm.
348
High-frequency Relay
G6Z
−
Three, 1.6-dia.
2.54
−
14
+
S
13 12 11
+
R
6
10 9
7
8
Mounting Dimensions (Bottom View)
Tolerance: ±0.1 mm
G6ZK-1PE-A
Terminal Arrangement/Internal
Connections (Bottom View)
Ten, 1.8-dia.
Orientation mark
1
Ten, 1.0-dia. holes
7.62
20
14
8.6
−
−
+
S
6
+
R
13 12 11
10 9
7
8
2.54
7.62
15.24
8.9
3
2.54
0.2
(Coil
terminal)
10-0.6
7.62
15.24
0.18
7.62
Note: Each value has a tolerance of ±0.3 mm.
Mounting Dimensions (Bottom View)
Tolerance: ±0.1 mm
G6ZK-1P
Nine, 1.8-dia.
Terminal Arrangement/Internal
Connections (Bottom View)
Orientation mark
1
7.62
20
8.6
3
−
Three, 1.6-dia.
Three, 0.8-dia. holes
2.54
4
5
−
Nine, 1.0-dia. holes
14
+
S
6
10 9
13 12
7
+
R
8
7.62
15.24
8.9
3
9-0.6
2.54
3-0.4
7.62
0.2
(Coil
terminal)
0.18
7.62
15.24
Note: Each value has a tolerance of ±0.3 mm.
Mounting Dimensions (Bottom View)
Tolerance: ±0.1 mm
G6ZK-1P-A
Twelve, 1.8-dia.
Terminal Arrangement/Internal
Connections (Bottom View)
Orientation mark
1
−
7.62
20
14
8.6
3
4
5
−
Twelve, 1.0-dia. holes.
+
S
13 12
6
7
+
R
10 9
8
2.54
7.62
15.24
8.9
3
2.54
12-0.6
7.62
15.24
0.2
(Coil
terminal)
0.18
7.62
Note: Each value has a tolerance of ±0.3 mm.
High-frequency Relay
G6Z
349
■ Surface Mount Terminal Types
Mounting Dimensions (Top View)
Tolerance: ±0.1 mm
G6Z-1FE
G6ZU-1FE
Terminal Arrangement/Internal
Connections (Top View)
G6Z-1FE
Orientation mark
14
15.24
7.62
13 12 11
10 9 8
2.54
0.8
0.8
0.8
2.3
−
+
7
1
8.6
20
G6ZU-1FE
0.2
(Coil
terminal)
9.3
6-0.6
2.54
8.3
Orientation mark
14
Six, 1.1
0.18
9.6
13 12 11
S −
R +
3-0.4
7.62
10 9 8
+
−
7
1
15.24
Note 1: Each value has a tolerance of ±0.3 mm.
2: The coplanarity of the terminals is 0.1 mm max.
Mounting Dimensions (Top View)
Tolerance: ±0.1 mm
G6Z-1FE-A
G6ZU-1FE-A
Terminal Arrangement/Internal
Connections (Top View)
G6Z-1FE-A
Orientation mark
14
15.24
7.62
13 12 11
−
8.3
+
7
1
8.6
20
9-0.6
G6ZU-1FE-A
Nine, 1.1
0.2
(Coil
terminal)
9.3
2.54
Orientation mark
14
0.18
9.6
13 12 11
S −
R +
7.62
15.24
Mounting Dimensions (Top View)
Tolerance: ±0.1 mm
G6Z-1F
G6ZU-1F
10 9 8
+
−
7
1
Note 1: Each value has a tolerance of ±0.3 mm.
2: The coplanarity of the terminals is 0.1 mm max.
Terminal Arrangement/Internal
Connections (Top View)
G6Z-1F
Orientation mark
14
15.24
2.54
0.8
0.8
13 12
8.3
+
3 4
1
5
7
8.6
20
Eight, 1.1
0.2
(Coil
terminal)
9.3
8-0.6
2.54
10 9 8
2.3
−
0.18
0.8
7.62
G6ZU-1F
Orientation mark
14
9.6
1
15.24
Note 1: Each value has a tolerance of ±0.3 mm.
2: The coplanarity of the terminals is 0.1 mm max.
High-frequency Relay
13 12
S −
R +
3-0.4
7.62
350
10 9 8
2.3
2.54
G6Z
10 9 8
+
−
3 4
5
7
Mounting Dimensions (Top View)
Tolerance: ±0.1 mm
G6Z-1F-A
G6ZU-1F-A
Terminal Arrangement/Internal
Connections (Top View)
G6Z-1F-A
Orientation mark
14
15.24
2.3
2.54
13 12
−
10 9 8
+
8.3
3 4
1
Eleven, 1.1
9.3
11-0.6
G6ZU-1F-A
7.62
0.2
(Coil
terminal)
2.54
7
5
8.6
20
Orientation mark
14
0.18
9.6
13 12
S −
R +
7.62
15.24
10 9 8
+
−
3 4
1
7
5
Note 1: Each value has a tolerance of ±0.3 mm.
2: The coplanarity of the terminals is 0.1 mm max.
Mounting Dimensions (Top View)
Tolerance: ±0.1 mm
G6ZK-1FE
Terminal Arrangement/Internal
Connections (Top View)
Orientation mark
14
15.24
7.62
2.54
0.8
0.8
0.8
−
2.3
+
S −
1
8.6
20
13 12 11
10 9 8
+
R
6
7
8.3
0.2
(Coil
terminal)
9.3
7-0.6
2.54
0.18
Seven, 1.1
9.6
3-0.4
7.62
15.24
Note 1: Each value has a tolerance of ±0.3 mm.
2: The coplanarity of the terminals is 0.1 mm max.
Mounting Dimensions (Top View)
Tolerance: ±0.1 mm
G6ZK-1FE-A
Terminal Arrangement/Internal
Connections (Top View)
Orientation mark
14
15.24
7.62
2.54
8.6
20
0.2
(Coil
terminal)
9.3
Ten, 0.6
2.54
−
8.3
0.18
13 12 11
10 9 8
2.3
+
S −
1
+
R
6
7
Ten, 1.1
9.6
7.62
15.24
Note 1: Each value has a tolerance of ±0.3 mm.
2: The coplanarity of the terminals is 0.1 mm max.
High-frequency Relay
G6Z
351
Mounting Dimensions (Top View)
Tolerance: ±0.1 mm
G6ZK-1F
Terminal Arrangement/Internal
Connections (Top View)
Orientation mark
14
15.24
7.62
2.54
0.8
0.8
−
2.3
+
S
10 9 8
−
+
R
5 6
3 4
1
8.6
20
13 12
7
8.3
0.2
(Coil
terminal)
9.3
Nine, 1.1
0.8
9.6
Nine, 0.6
2.54
0.18
Three, 0.4
7.62
15.24
Note 1: Each value has a tolerance of ±0.3 mm.
2: The coplanarity of the terminals is 0.1 mm max.
Mounting Dimensions (Top View)
Tolerance: ±0.1 mm
G6ZK-1F-A
Terminal Arrangement/Internal
Connections (Top View)
Orientation mark
14
15.24
7.62
2.54
8.6
20
0.2
(Coil
terminal)
9.3
2.54
Twelve, 0.6
0.18
Twelve, 1.1
9.6
15.24
Note 1: Each value has a tolerance of ±0.3 mm.
2: The coplanarity of the terminals is 0.1 mm max.
High-frequency Relay
G6Z
13 12
−
8.3
7.62
352
2.3
1
+
S
3 4
10 9 8
−
+
R
5 6
7
Packaging
1. Tube Packaging
Reel Dimensions
33.5±1
Relays in tube packaging are arranged so that the orientation mark
of each Relay in on the left side.
37.5±1
13±0.2 dia.
Be sure not to make mistakes in Relay orientation when mounting
the Relay to the PCB.
21±0.8 dia.
2±0.5
A
Operation of Relays
Stopper (gray)
Stopper (green)
330
80
R1
Enlarged view of A
Tube length: 530 mm (stopper not included)
No. of Relays per tube: 25
2. Tape and Reel Packaging (Surface mount
Terminal Models)
Carrier Tape Dimensions
2±0.1
16±0.1
4±0.1
10±0.1
1.5+00.1 dia.
1.75±0.1
When ordering Relays in tape packing, add the prefix “-TR” to the
model number, otherwise the Relays in stick packing will be provided.
0.5±0.05
14.2±0.1
Relays per Reel: 300
28.4±0.1
22.6±0.1
20.6±0.1
32±0.3
Direction of Relay Insertion
Pulling direction
10.2±0.1
Orientation mark
5° max.
Top tape
(cover tape)
A
4±0.1
1.5+00.1
0.2
Pulling
direction
5° max.
1.7+00.15
R0.75
Enlarged view of A
Note: The radius of the unmarked corner is 0.3 mm.
Carrier tape
Emboss
tape
Recommended Soldering Method
■ Temperature Conditions for IRS Method
Temperature
When using reflow soldering, ensure that the Relay terminals and the
top of the case stay below the following curve. Check that these
conditions are actually satisfied before soldering the terminals.
T4
Do not quench the terminals after mounting. Clean the Relay using
alcohol or water no hotter than 40°C max.
The thickness of cream solder to be applied should be between
150 and 200 μm on OMRON’s recommended PCB pattern.
Correct Soldering
Incorrect Soldering
T3
Relay
T2
PCB
T1
Terminal
Solder
Land
Insufficient
amount of
solder
Excessive
amount of
solder
Check the soldering in the actual mounting conditions before use.
t1
Preheating
t2
Soldering Time
Measured
part
Preheating
(T1 → T2, t1)
Soldering
(T3, t2)
Maximum peak
(T4)
Terminals
150 → 180°C,
120 s max.
230°C min,
30 s max.
250°C max.
Top of case
---
---
255°C max.
High-frequency Relay
G6Z
353
Safety Precautions
■ Precautions for Correct Use
Please observe the following precautions to prevent failure to
operate, malfunction, or undesirable effect on product performance.
Substrate for High-frequency Characteristic Compensation
(75-Ω Models, E-shape or Y-shape)
30.7
20
(Unit: mm)
4-dia. through-hole
High-frequency Characteristics Measurement Method
and Measurement Substrate
High-frequency characteristics for the G6Z are measured in the way
shown below. Consult your OMRON representative for details on
50-Ω models.
0.6-dia. through-hole
0.95
40
1
30
Measurement Method for 75-Ω Models
G6Z
Network vector analyzer
(Agilent Technologies)
75-Ω terminating
resistance
HP8753D
Substrate Types
50Ω/75Ω adapter
(Agilent Technologies)
11852B-004
Material: FR-4 glass epoxy (glass cloth impregnated with epoxy
resin and copper laminated to its outer surface)
Thickness: 1.6 mm
Thickness of copper plating:18 μm
Through-hole Substrate (75-Ω Models, E-shape or Y-shape)
40
30
4-dia. through-hole
0.4
1.4
(Unit: mm)
Note:
Note:
Note:
3.59
Note:
40
30
1
6.3
0.95
Note:
1. The compensation substrate is used when measuring the
Relay’s insertion loss. The insertion loss is obtained by
subtracting the measured value for the compensation
substrate from the measured value with the Relay
mounted to the high-frequency measurement substrate.
2. For convenience, the diagrams of the high-frequency
measurement substrates given here apply both to models
with an E-shape terminal structure and to models with a
Y-shape terminal structure.
3. Be sure to mount a standoff tightly to the through-hole
substrate.
4. Use measuring devices, connectors, and substrates that
are appropriate for 50 Ω and 75 Ω respectively.
5. Ensure that there is no pattern under the Relay.
Otherwise, the impedance may be adversely affected and
the Relay may not be able to attain its full characteristics.
Handling
0.6-dia. through-hole
Do not use the Relay if it has been dropped. Dropping the Relay may
adversely affect its functionality.
SMD-type Substrate (75-Ω Models, E-shape or Y-shape)
40
30
Flow Soldering
4-dia. through-hole
Solder: JIS Z3282, H63A
1.4
(Unit: mm)
Protect the Relay from direct sunlight and keep the Relay under normal temperature, humidity, and pressure.
0.4
Soldering temperature: Approx. 250°C (260°C if the DWS method is
used)
0.6-dia. through-hole
Soldering time: Approx. 5 s max. (approx. 2 s for the first time and
approx. 3 s for the second time if the DWS method is used)
Be sure to make a molten solder level adjustment so that the solder
will not overflow on the PCB.
40
30
3.91
0.95
6.3
1
354
High-frequency Relay
G6Z
Claw Securing Force During Automatic Mounting
During automatic insertion of Relays, be sure to set the securing
force of each claw to the following so that the Relay’s characteristics
will be maintained.
B
A
Direction A: 4.90 N max.
Direction B: 4.90 N max.
Direction C: 4.90 N max.
Secure the claws to the shaded area.
Do not attach them to the center area
or to only part of the Relay.
Latching Relay Mounting
Make sure that the vibration or shock that is generated from other
devices, such as Relays, on the same panel or substrate and
imposed on the Latching Relay does not exceed the rated value, otherwise the set/reset status of the Latching Relay may be changed.
The Latching Relay is reset before shipping. If excessive vibration or
shock is imposed, however, the Latching Relay may be set accidentally. Be sure to apply a reset signal before use.
Coating
Do not use silicone coating to coat the Relay when it is mounted to
the PCB. Do not wash the PCB after the Relay is mounted using
detergent containing silicone. Otherwise, the detergent may remain
on the surface of the Relay.
High-frequency Relay
G6Z
355
MEMO
356
High-frequency Relay
G6Z
Omron Electronic Components, LLC
Terms and Conditions of Sales
I. GENERAL
1. Definitions: The words used herein are defined as follows.
(a) Terms:
These terms and conditions
(b) Seller:
Omron Electronic Components LLC and its subsidiaries
(c) Buyer:
The buyer of Products, including any end user in section III through VI
(d) Products: Products and/or services of Seller
(e) Including: Including without limitation
2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments,
invoices, purchase orders and other documents, whether electronic or in writing, relating
to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's
purchase order or other documents which are inconsistent with, or in addition to, these
Terms.
3. Distributor: Any distributor shall inform its customer of the contents after and including
section III of these Terms.
II. SALES
1. Prices; Payment: All prices stated are current, subject to change without notice by Seller.
Buyer agrees to pay the price in effect at the time the purchase order is accepted by
Seller. Payments for Products received are due net 30 days unless otherwise stated in
the invoice. Buyer shall have no right to set off any amounts against the amount owing in
respect of this invoice.
2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to
Buyer after deducting transportation charges, taxes and duties, and will be allowed only
if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past
due amounts owing to Seller.
3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum
legal rate, whichever is less, on any balance not paid within the stated terms.
4. Orders: Seller will accept no order less than 200 U.S. dollars net billing.
5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer
shall make remittance to Seller at the then current exchange rate most favorable to
Seller; provided that if remittance is not made when due, Buyer will convert the amount
to U.S. dollars at the then current exchange rate most favorable to Seller available
during the period between the due date and the date remittance is actually made.
6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining
any government approvals regarding the importation or sale of the Products.
7. Taxes: All taxes, duties and other governmental charges (other than general real
property and income taxes), including any interest or penalties thereon, imposed directly
or indirectly on Seller or required to be collected directly or indirectly by Seller for the
manufacture, production, sale, delivery, importation, consumption or use of the Products
sold hereunder (including customs duties and sales, excise, use, turnover and license
taxes) shall be charged to and remitted by Buyer to Seller.
8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller,
Seller reserves the right to stop shipments or require satisfactory security or payment in
advance. If Buyer fails to make payment or otherwise comply with these Terms or any
related agreement, Seller may (without liability and in addition to other remedies) cancel
any unshipped portion of Products sold hereunder and stop any Products in transit until
Buyer pays all amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid
accounts.
9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer
indemnifies Seller fully against all costs or expenses arising in connection therewith.
10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from
causes beyond its control, including earthquakes, fires, floods, strikes or other labor
disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots,
delay in or lack of transportation or the requirements of any government authority.
11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller:
(a) All sales and shipments of Products shall be FOB shipping point (unless otherwise
stated in writing by Seller), at which point title to and all risk of loss of the Products
shall pass from Seller to Buyer, provided that Seller shall retain a security interest in
the Products until the full purchase price is paid by Buyer;
(b) Delivery and shipping dates are estimates only; and
(c) Seller will package Products as it deems proper for protection against normal
handling and extra charges apply to special conditions.
12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products
occurring before delivery to the carrier or any claim related to pricing or other charges
must be presented in detail in writing to Seller within 30 days of receipt of shipment.
III. PRECAUTIONS
1. Suitability: IT IS THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY
OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE
APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING
APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE
BUYER’S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC
COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E)
SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT.
Buyer acknowledges that it alone has determined that the Products will meet their
requirements of the intended use in all cases. Buyer must know and observe all
prohibitions of use applicable to the Product/s.
2. Use with Attention: The followings are some examples of applications for which
particular attention must be given. This is not intended to be an exhaustive list of all
possible use of any Product, nor to imply that any use listed may be suitable for any
Product:
(a) Outdoor use, use involving potential chemical contamination or electrical
interference.
(b) Use in consumer Products or any use in significant quantities.
(c) Energy control systems, combustion systems, railroad systems, aviation systems,
medical equipment, amusement machines, vehicles, safety equipment, and
installations subject to separate industry or government regulations.
(d) Systems, machines, and equipment that could present a risk to life or property.
3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE
PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED
VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY
SELLER.
5. Programmable Products: Seller shall not be responsible for the Buyer's programming of
a programmable Product.
IV. WARRANTY AND LIMITATION
1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in
materials and workmanship for a period of twelve months from the date of sale by Seller
(or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY
OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES,
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE OF THE PRODUCTS.
2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form
originally shipped with Buyer responsible for labor charges for removal or replacement
thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an
amount equal to the purchase price of the Product; provided that there shall be no
liability for Seller or its affiliates unless Seller's analysis confirms that the Products were
correctly handled, stored, installed and maintained and not subject to contamination,
abuse, misuse or inappropriate modification. Return of any Products by Buyer must be
approved in writing by Seller before shipment.
3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF
PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED
WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT,
WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL
LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF
THE PRODUCT ON WHICH LIABILITY IS ASSERTED.
4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its
employees from and against all liabilities, losses, claims, costs and expenses (including
attorney's fees and expenses) related to any claim, investigation, litigation or proceeding
(whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or
omissions under these Terms or in any way with respect to the Products.
V. INFORMATION; ETC.
1. Intellectual Property: The intellectual property embodied in the Products is the exclusive
property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way
without the written permission of Seller. Buyer (at its own expense) shall indemnify and
hold harmless Seller and defend or settle any action brought against Seller to the extent
that it is based on a claim that any Product made to Buyer specifications infringed
intellectual property rights of another party.
2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or
tooling, all engineering and tooling shall remain the exclusive property of Seller. All
information and materials supplied by Seller to Buyer relating to the Products are
confidential and proprietary, and Buyer shall limit distribution thereof to its trusted
employees and strictly prevent disclosure to any third party.
3. Performance Data: Performance data is provided as a guide in determining suitability
and does not constitute a warranty. It may represent the result of Seller's test conditions,
and the users must correlate it to actual application requirements.
4. Change In Specifications: Product specifications and descriptions may be changed at
any time based on improvements or other reasons. It is Seller’s practice to change part
numbers when published ratings or features are changed, or when significant
engineering changes are made. However, some specifications of the Product may be
changed without any notice.
5. Errors And Omissions: The information on Seller’s website or in other documentation
has been carefully checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses
regarding (a) export of the Products or information provided by Seller; (b) sale of
Products to forbidden or other proscribed persons or organizations; (c) disclosure to noncitizens of regulated technology or information.
VI. MISCELLANEOUS
1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing
between Buyer and Seller shall operate as a waiver of rights by Seller.
2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent.
3. Law: These Terms are governed by Illinois law (without regard to conflict of laws).
Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any
dispute hereunder.
4. Amendment: These Terms constitute the entire agreement between Buyer and Seller
relating to the Products, and no provision may be changed or waived unless in writing
signed by the parties.
5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall
not invalidate any other provision.
High-frequency Relay
G6Z
Certain Precautions on Specifications and Use
1. Suitability for Use. Seller shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in
Buyer's application or use of the Product. At Buyer's request, Seller will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use.
Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer
shall take application responsibility in all cases but the following is a nonexhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to separate industry or government
regulations.
(iii) Use in consumer products or any use in significant quantities.
(iv) Systems, machines and equipment that could present a risk to life or
property. Please know and observe all prohibitions of use applicable to this
product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT
THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
2. Programmable Products. Seller shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
3. Performance Data. Performance data given in this publication is provided as
a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Seller's test conditions, and the users must
correlate it to actual application requirements. Actual performance is subject to
Seller's Warranty and Limitations of Liability.
4. Change in Specifications. Product specifications and accessories may be
changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Seller representative at any time to
confirm actual specifications of purchased Product.
5. Errors and Omissions. The information in this publication has been carefully
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors, or omissions.
6. RoHS Compliance. Where indicated, our products currently comply, to the
best of our knowledge as of the date of this publication, with the requirements
of the European Union's Directive on the Restriction of certain Hazardous
Substances ("RoHS"), although the requirements of RoHS do not take effect
until July 2006. These requirements may be subject to change. Please consult
our website for current information.
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website
at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
Global - http://www.omron.com
USA - http://www.components.omron.com
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. X302-E-1
08/09
High-frequency Relay
G6Z
Specifications subject to change without notice
Printed in USA