INVERTERS PBMPLS Series 5 0 0 - 7 0 0 0 W AT T S D C / A C I N V E R T E R Features • • • • • • True sinewave waveform. Massive inrush and overload capability. Galvanically isolated. High efficiency toroidal transformer. DC circuit breaker/ BATT isolator switch Wall mounted design. Specifications STANDARDS AND APPROVALS INPUT Voltage Voltage range 12, 24, 48 (Standard).36, 72, 96, 120 (Also available). -20% to +45% of nominal. OUTPUT AS3100, AS3000 C-tick AS/NZS CISPR14, AS/NZS 1044 EMC standards AS2279, EN55014 ENVIRONMENTAL Voltage 230Vac ±4% (Standard). 110Vac ±4% (Option). Frequency 50/60Hz ±0.1 Output waveform True sinewave < 4% THD. Options Power factor correction All conditions. CODE Crest factor >4 ADD OPTION TO THE END OF INVERTER PART NUMBER Load start sensitivity 0-20W D RCD fitted in place of hardware junction box of AC output. G MIL spec conformal coating applied to final assembly. R Ruggedisation for high vibration environment. K Automatic transfer switch 25Amp for 1000W to 1800W. KX Automatic transfer switch with ON delay timer and voltage sensing module. 40Amps for 2000W to 4000W and 65Amp for 5000W to 7000W models. V AC output voltage e.g. 100-120Vac. H Frequency 60Hz L “AC OK” alarm relay contact C Twin switched GPO (available only on 1000W to 5000W models). D Twin switched RCD GPO (available only on 1000W to 5000W models). DC to AC isolation 3500V Over-load protection Yes. Over-temperature protection Yes. Short circuit protection Yes. BATT under and over voltage protection Yes. LED status indicators ON, standby mode, over-temperature, over-load, BATT under voltage, BATT over-voltage. OPERATING AC Outlet 450 Safety standards Single power outlet (500-600W models). Single power outlet & screw terminal junction box (1000-1800W models). Screw terminal junction box (2000-7000W models). Battery Leads Heavy duty low loss battery leads. Dimensions 500-600W: 260x160x100mm. 1000-1800W: 330x296x150mm. 2000-3500W: 370x386x180mm. 4000-7000W: 475x458x187mm. Cooling Thermostatically controlled 2-speed fan. Temperature Range -10°C to 50°C, derate above 40°C by 10% INVERTERS PBMPLS Series 5 0 0 - 7 0 0 0 W AT T S D C / A C I N V E R T E R Selection Table DC INPUT INPUT RANGE CONT. RATING ½ HOUR RATING PBMPLS-12U 12V 10.5-17V 500W 550W 1500W 90% 5.5KG PBMPLS-24X 24V 21-34V 600W 750W 2000W 92% 5.5KG PBMPLS-48X 48V 42-68V 600W 750W 2000W 93% 5.5KG PBMPLS-12W 12V 10.5-17V 1000W 1150W 3000W 91% 11KG PBMPLS-24V 24V 21-34V 1200W 1600W 3600W 92% 11KG PBMPLS-48V 48V 42-68V 1200W 1600W 3600W 94% 11KG PBMPLS-12V 12V 10.5-17V 1500W 1600W 4500W 91% 14KG PBMPLS-24I 24V 21-34V 1800W 2200W 5400W 94% 14KG PBMPLS-48I 48V 42-68V 1800W 2200W 5400W 94% 14KG PBMPLS-12I 12V 10.5-17V 2000W 2200W 6000W 90% 22KG PBMPLS-24IA 24V 21-34V 2300W 2800W 7000W 94% 22KG PBMPLS-48IA 48V 42-68V 2500W 3000W 7500W 94% 22KG PBMPLS-24Z 24V 21-34V 3000W 3700W 9000W 93% 24KG PBMPLS-48Z 48V 42-68V 3500W 4100W 10500W 94% 24KG PBMPLS-24ZA 24V 21-34V 4000W 4500W 12000W 94% 30KG PBMPLS-48ZC 48V 42-68V 5000W 6000W 15000W 95% 30KG PBMPLS-48ZH 48V 42-68V 7000W 8500W 20000W 95% 34KG MODEL NUMBER SURGE 5 SEC PEAK EFF% Your dependable power partner – www.powerbox.com.au WEIGHT 451