OPEN FRAME & ENCLOSED PC2000 1 0 0 0 - 2 0 0 0 W AT T S D C / D C S I N G L E Features • • • • • • • Overvoltage protection, (OVP). Alarm circuit with relay output. Current sharing. Inhibit/Power down input. Over voltage protection OVP. Output voltage adjustable on front panel. Operating temperature -25 to +55OC. Specifications ENVIRONMENTAL INPUT Voltage Isolation 20 - 30V (24), 41 - 60V(48), 93 - 150V (110), 187 - 300V (220) Input – Output: 4kVd (Input code 24, 48, 72) Input – Output: 3kVac / 4.3kVdc (Input code 110, 220) Input – Alarm: 2.5kVdc (Input – Output 24, 48, 72) Input – Alarm: 3kVac / 4.3kVdc (Input code 110, 220) Input – Case: 2.5kVdc (Input code 24, 48, 72) Input – Case: 3kVac / 4.3kVdc (Input – code 110, 220) Alarm – Case: 2.5kVdc Output – Case: 2.5kVdc Output – Alarm: 2.5kVdc Operating temperature -25°C to 55°C (100% load). -25°C to +70°C (with derating), contact Powerbox for details. Temperature coefficient 0.02%. Storage temperature -40°C to 85°C. GENERAL Cooling See table. Mounting brackets Please consult Powerbox for mounting options Optional Features - Conformally coating, option I. For environment with high non-condensing humidity max 98% RH. - Series diode on output. Specify series diode output when the output is connected in parallel with other power supply to achieve redundancy. The output is derated 10% on 24V and 5% on 48V. -Train input, option T. Input voltage range according to train Standard EN50155 and IEC 60751. OUTPUT Voltage See table. STANDARDS Current See table. Safety EN/IEC60950-1: 2001 Source regulation 0.1%. C-tick AS/NZS CISPR11 Group 1, Class A Load regulation 0.5% 0.2% (with sense connected) 0-100% EMI IEC/EN61000-6-2, EN55011/EN55022 class B, Output ripple 30mV p-p (120kHz) EMC Voltage adjustment 95% - 110%. Current limit protection 105%. Overvoltage protection 115%. Reverse voltage protection Yes. IEC/EN 61000-6-2 IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 IEC/EN 61000-4-8 IEC/EN 61000-4-10 Over/under voltage alarm 90%-115% of nominal output. Overheated alarm Yes. Remote sense Yes. Soft start Yes. Start-up time <3s Hold-up time 2-25ms Efficiency 89-93% Your dependable power partner – www.powerbox.com.au 139 OPEN FRAME & ENCLOSED PC2000 1 0 0 0 - 2 0 0 0 W AT T S D C / D C S I N G L E Selection Table MODEL NUMBER INPUT PC1000 24/24 20-32V 24V 42A Convection 1000W PC1000 24/28 20-32V 28V 36A Convection 1000W PC1000 24/36* 20-32V 36V 28A Convection 1000W PC1000 24/48 20-32V 48V 21A Convection 1000W PC1000 48/24 43-60V 24V 42A Convection 1000W PC1000 48/28 43-60V 28V 36A Convection 1000W PC1000 48/36* 43-60V 36V 28A Convection 1000W PC1000 48/48 43-60V 48V 21A Convection 1000W PC1000 110/24 93-150V 24V 42A Convection 1000W PC1000 110/28 93-150V 28V 36A Convection 1000W PC1000 110/36* 93-150V 36V 28A Convection 1000W PC1000 110/48 93-150V 48V 21A Convection 1000W PC1000 220/24 187-300V 24V 42A Convection 1000W PC1000 220/28 187-300V 28V 36A Convection 1000W PC1000 220/36* 187-300V 36V 28A Convection 1000W PC1000 220/48 187-300V 48V 21A Convection 1000W PC1400 48/24 43-60V 24V 58A Fan 1400W PC1400 48/28 43-60V 28V 58A Fan 1400W PC2000 48/36* 43-60V 36V 56A Fan 2000W PC2000 48/48 43-60V 48V 42A Fan 2000W PC1400 110/24 93-150V 24V 58A Fan 1400W PC1400 110/28 93-150V 28V 58A Fan 1400W PC2000 110/36* 93-150V 36V 56A Fan 2000W PC2000 110/48 93-150V 48V 42A Fan 2000W PC1400 220/24 187-300V 24V 58A Fan 1400W PC1400 220/28 187-300V 28V 58A Fan 1400W PC2000 220/36* 187-300V 36V 56A Fan 2000W PC2000 220/48 187-300V 48V 42A Fan 2000W * NRE might be charged. 140 OUTPUT COOLING POWER T-INPUT RANGE FOR MOBILE APPLICATION UIN 0.1S-S2 CONTINUOUS RANGE CODE 14.4-33.6V 16.8-30V 24T 21.6-50.4V 25.2-45V 36T 28.8-67.2V 33.6-60V 48T 43.2-110.8V 50.4-90V 72T 66-154V 77-137.5V 110T