SUMIDA CDEPI115MENP

Power Inductor
CDEPI115ME
■ Features
◎ Magnetically shielded construction.
◎ Storage temperature range: -40℃~+125℃.
◎ Operating temperature range: -40℃~+125℃
(including coil’s self-heat).
◎ Qualification to AEC-Q200.
◎ RoHS Compliance.
■ Applications
Ideally used in Automotive, etc.
■ Shapes and Dimensions/Recommended Land Patterns (mm)
◆ Dimensions
±0.4
4.4
5.5 Max.
3.75
2.6 0.2
12.0
2.1 0.2
±
2.6 0.2
11.0
±
5.5
0.4
±
±
◆ Land pattern
◆ Schematics (Bottom)
2
3
1
1
Power Inductor
CDEPI115ME
■Electrical Characteristics specification.
Inductance
(µH)
100KHz/1V
Sumida P/N
CDEPI115MENP-R27PC
CDEPI115MENP-R62PC
CDEPI115MENP-1R0PC
CDEPI115MENP-1R6PC
CDEPI115MENP-2R4PC
CDEPI115MENP-3R3PC
CDEPI115MENP-4R3PC
CDEPI115MENP-5R6PC
±25%
0.62±25%
1.0±25%
1.6±25%
2.4±25%
3.3±25%
4.3±25%
5.6±25%
0.27
Ω
D.C.R. (m )
Max. (Typ.)
at 20
Saturation Current
(A)
1
at 20
Temperature
Rise Current
(A)
2
1.72(1.43)
42.0
16.3
2.77(2.31)
27.0
13.3
4.28(3.57)
22.0
10.5
6.73(5.61)
16.5
8.4
9.85(8.21)
14.5
6.9
14.3(11.9)
12.0
5.8
16.3(13.6)
10.0
5.4
22.6(18.8)
9.0
4.7
℃
※
℃
※
※1、Saturation Current: This indicates the value of DC current when the inductance decreases to 80% of
its nominal value.
※2、Temperature Rise Current: The actual current when temperature of coil becomes △T=40℃.(Ta=20℃)
For More Information
Hong Kong
Shanghai
Shenzhen
Taipei
Tel.+852-2880-6688
FAX.+852-2565-9600
Tel.+86-021-58363299
FAX.+86-021-58363266
Tel.+86-755-82910228
FAX.+86-755-82910338
Tel.+886-2-27065228
FAX.+886-2-27065229
Tokyo
Seoul
Singapore
Malaysia
Tel.+81-3-5202-7112
FAX.+81-3-5202-7105
Tel.+82-2-6237-0777
FAX.+82-2-6237-0778
Tel.+65-6296-3388
FAX.+65-6296-3390
Tel.+60-3-8733-0900
FAX.+60-3-8737-7384
Chicago
California
Tel.+1-847-545-6700
FAX. +1-847-545-6720
Tel.+1-408-321-9660
FAX. +1-408-321-9308
2