DBLECTRO JQX-102F

Présente / Presents:
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
JQX- 102F
NHG RELAYS
Operation condition
JQX- 102F
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
03001003507
1000M
Shock resistance
R
R2133344
30.5 16.0 23.5 30.5 16.0 26.5
C
US
E158859
Vibration resistance
Features
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
Can be welded directly onto PCB.
Used in household appliances like air conditioning , heater and instruments etc.
min (at 500VDC)
Item 7 of IEC255-5
50Hz 1500V
50Hz 4500V
Surge voltage:10kV
Functional:200m/s2
11ms
Survival:1000 m/s2 11ms
10~55Hz
double amplitude Functional 1.5mm
double amplitude Survival 2.0mm
10N 8N
235
2
3 0.5s
-25~70
85% (at 40 )
23g
Item 6 of IEC255-5
Item 6 of IEC255-5
Item 8 of IEC255-5
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1 and Ua2
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table
Ordering Information
3
5
Load
5 Terminal b:PC type NIL:PC type and QC type
6 Coil rated voltage(V) DC:5,12,24,48
7 Contact material C:AgCdO NIL:AgSnO2
8 Coil power consumption 0.9:0.9W
2 10
1.8
Max. Switching Current:20A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
0.071
Item 3.31 of IEC255-7
3
10.2 8.3
0.402 0.327
30.5max.
1.201max.
1.4
0.055
0.8
0.031
005-900
012-900
024-900
048-500
Rated
Max.
5
12
24
48
6
14.4
28.8
57.6
Coil
resistance
10%
27.8
160
640
2560
3.5
8.4
16.8
33.6
Release
voltage
VDC(min)
(10% of
rated
voltage)
Coil power
consumption
W
0.5
1.2
2.4
4.8
0.9
Operate
Time
ms
Release
Time
ms
2-1.5 0.3
0.059 0.012
30.5max.
1.201max.
1.4
0.055
0.8
0.031
2-1.5 0.3
0.059 0.012
1.8
0.071
2-1.5 0.8
0.059 0.031
0.3
0.012
16max.
0.630max.
0.3
0.012
1.8
0.071
2-1.5 0.8
0.059 0.031
Dimensions
20
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
10
1.8
12
0.472 0.071
Dash
numbers
Pick up
voltage
VDC(max)
(70% of rated
voltage )
3.5
0.138
Coil Parameter
Coil voltage
VDC
8.0
0.244
6.2
0.244
0.248
3.2
0.126
18.4
0.724
6.3
9.4
0.370
0.5
0.020
6
8.4
0.331
4
23.5max.
0.925max.
Mechanical
1A SPSTNO
AgSnO2 AgCd
20A/250VAC
5000VA
300VAC
30m
(at 1A/14VDC)
105
mm /inch
3.4
0.138
2
0.079
life
20A/250VAC
Dimensions
Contact Data
Contact Arrangement
Contact Material
Contact Rating( Resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation
Electrical
20A/250VAC COS =0.9
26.5max.
1.043max.
1 Part number JQX-102F
2 Contact arrangement A:1A
3 Enclosure Z: Dust cover
4 Contact rating Resistive:20A/250VAC
20A/250VAC
8
3.5
0.138
7
CQC
4- 1.8
0.071
27.6
1.087
1.4
0.055
22
5.2
0.205
16
0.630
6
TU V
10
0.394
4
UL&CUR
6.4
0.252
2
b DC12V C 0.9
0.5
0.020
1
Safety approval
Z 20
16max.
0.630max.
JQX-102F A
of IEC255-19-1 and minimum sample size 24.
Safety approvals
0.866
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Mounting (Bottom view)
NO
4
1
COM
3
2
Wiring diagram
(Bottom view)
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
Ningbo Forward Relay Corporation LTD.
114
JQX- 102F
Operation condition
JQX- 102F
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
03001003507
1000M
Shock resistance
R
R2133344
30.5 16.0 23.5 30.5 16.0 26.5
C
US
E158859
Vibration resistance
Features
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
Can be welded directly onto PCB.
Used in household appliances like air conditioning , heater and instruments etc.
min (at 500VDC)
Item 7 of IEC255-5
50Hz 1500V
50Hz 4500V
Surge voltage:10kV
Functional:200m/s2
11ms
Survival:1000 m/s2 11ms
10~55Hz
double amplitude Functional 1.5mm
double amplitude Survival 2.0mm
10N 8N
235
2
3 0.5s
-25~70
85% (at 40 )
23g
Item 6 of IEC255-5
Item 6 of IEC255-5
Item 8 of IEC255-5
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1 and Ua2
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table
Ordering Information
3
5
Load
5 Terminal b:PC type NIL:PC type and QC type
6 Coil rated voltage(V) DC:5,12,24,48
7 Contact material C:AgCdO NIL:AgSnO2
8 Coil power consumption 0.9:0.9W
2 10
1.8
Max. Switching Current:20A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
0.071
Item 3.31 of IEC255-7
3
10.2 8.3
0.402 0.327
30.5max.
1.201max.
1.4
0.055
0.8
0.031
005-900
012-900
024-900
048-500
Rated
Max.
5
12
24
48
6
14.4
28.8
57.6
Coil
resistance
10%
27.8
160
640
2560
3.5
8.4
16.8
33.6
Release
voltage
VDC(min)
(10% of
rated
voltage)
Coil power
consumption
W
0.5
1.2
2.4
4.8
0.9
Operate
Time
ms
Release
Time
ms
2-1.5 0.3
0.059 0.012
30.5max.
1.201max.
1.4
0.055
0.8
0.031
2-1.5 0.3
0.059 0.012
1.8
0.071
2-1.5 0.8
0.059 0.031
0.3
0.012
16max.
0.630max.
0.3
0.012
1.8
0.071
2-1.5 0.8
0.059 0.031
Dimensions
20
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
10
1.8
12
0.472 0.071
Dash
numbers
Pick up
voltage
VDC(max)
(70% of rated
voltage )
3.5
0.138
Coil Parameter
Coil voltage
VDC
8.0
0.244
6.2
0.244
0.248
3.2
0.126
18.4
0.724
6.3
9.4
0.370
0.5
0.020
6
8.4
0.331
4
23.5max.
0.925max.
Mechanical
1A SPSTNO
AgSnO2 AgCd
20A/250VAC
5000VA
300VAC
30m
(at 1A/14VDC)
105
mm /inch
3.4
0.138
2
0.079
life
20A/250VAC
Dimensions
Contact Data
Contact Arrangement
Contact Material
Contact Rating( Resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation
Electrical
20A/250VAC COS =0.9
26.5max.
1.043max.
1 Part number JQX-102F
2 Contact arrangement A:1A
3 Enclosure Z: Dust cover
4 Contact rating Resistive:20A/250VAC
20A/250VAC
8
3.5
0.138
7
CQC
4- 1.8
0.071
27.6
1.087
1.4
0.055
22
5.2
0.205
16
0.630
6
TU V
10
0.394
4
UL&CUR
6.4
0.252
2
b DC12V C 0.9
0.5
0.020
1
Safety approval
Z 20
16max.
0.630max.
JQX-102F A
of IEC255-19-1 and minimum sample size 24.
Safety approvals
0.866
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Mounting (Bottom view)
NO
4
1
COM
3
2
Wiring diagram
(Bottom view)
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
113
Ningbo Huaguan Relay Corporation LTD.