DBLECTRO NG4UCZ10DC12V

Présente / Presents:
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
NG4U
NHG RELAYS
NG4U
R
R2133923
22.5 12.5 19
C
US
E160644
Features
Can be welded directly onto PCB.
Used in household appliances like air conditioning , heater and instruments etc.
Operation condition
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
250M
min (at 500VDC)
Item 7 of IEC255-5
50Hz 750V
50Hz 2000V surge voltage 4kV
Item 6 of IEC255-5
Item 6 and item 8 of IEC255-5
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
100m/s2
11ms
10~55Hz double amplitude 1.5mm
5N
235
2
3 0.5s
-25~70
85% (at 40 )
8.6g
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table
of IEC255-19-1 and minimum sample size 24.
Safety approvals
Safety approval
Ordering Information
NG4U C S 10 DC12V
5
4 Contact current 5A,10A
5 Coil rated voltage(V) DC:6,12,24
Dimensions
Contact Data
280W 1250VA
Max. Switching Voltage
30VDC 220VAC
50m
Max. Switching Current:10A
5
Item 3.12 of IEC255-7
Operational
Electrical
105
Item 3.30 of IEC255-7
life
Mechanical
107
Item 3.31 of IEC255-7
0.051
0.3
5A,10A/125VAC,28VDC
Max. Switching Power
0.012
Contact Rating (resistive)
5- 1.3
3.50
AgCdO AgSnO2
19max.
Contact Material
Contact Resistance or Voltage drop
1C (SPDT(B-M))
0.748max.
1A (SPSTNO)
4-1 0.4
0.039 0.016
0.197
1 0.16
0.039 0.006
3.75
0.148
15
0.591
Dimensions
Coil Parameter
Coil voltage
VDC
Rated
12.5max.
0.492max.
22.5max.
0.886max.
Contact Arrangement
Dash
numbers
mm /inch
Coil
resistance
10%
Max.
Pickup
voltage
VDC(max)
(75% of rated
voltage)
Release
voltage
VDC(min)
(10% of rated
voltage)
006-360
6
7.8
100
4.2
0.6
012-360
12
15.6
400
8.4
1.2
024-360
24
31.2
1600
16.8
2.4
Coil power
consumption
W
0.36
7.5
0.295
4
5A/250VAC;28VDC
10
0.394
3
1 Part number NG4U
2 Contact arrangement A:1A C:1C
3 Enclosure S:Sealed type Z:Dust cover
0.138
2
TU V
10A/125VAC 5A/250VAC
0.4
0.016
1
UL& C UR
Load
Operate
Time
ms
Mounting (Bottom view)
Release
Time
ms
10
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
5
1C
1A
Wiring diagram
(Bottom view)
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
Ningbo Huaguan Relay Corporation LTD.