DBLECTRO JQX-54WA20DC24VCB

Présente / Presents:
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
JQX- 54W
NHG RELAYS
JQX- 54W
Operation condition
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
04001010696
R
on Pending
30.4 28.5 18.5
C
US
Shock resistance
E160644
Vibration resistance
Features
Can be welded directly onto PCB.
Compact high capacity relay for inductive load, rushing current of 80A and steady-state current of 25A.
Used in household appliances like air conditioning , heater and instruments etc.
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
1000M
min (at 500VDC)
Item 7 of IEC255-5
50Hz 1200V
50Hz 3600V
surge voltage:10kV
Functional:100m/s2
11ms
Survival:1000 m/s2 11ms
10~55Hz
double amplitude Functional 1.0mm
double amplitude Survival 2.0mm
10N 8N
235
2
3 0.5s
-40~85
20~85%
31.5g
Item 6 of IEC255-5
Item 6 of IEC255-5
Item 8 of IEC255-5
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1 and Ua2
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table
Ordering Information
JQX-54W A 25
1
2
DC12V C B
3
4
5
Safety approval
6
1 Part number JQX-54W
2 Contact arrangement A:1A
3 Contact rating Resistive: 25A/277VAC 30VDC
Inductive:20A/250VAC cos =0.7
of IEC255-19-1 and minimum sample size 24.
Safety approvals
UL&CUR
Load
4 Coil rated voltage(V) DC:5,6,9,12,24,48,110
5 Contact material C:AgCdO NIL:AgSnO2
6 Resistance heat class B:130
F:155
25A/277VAC
1
12
CQC
25A/250VAC
HP250VAC 1HP125VAC
mm /inch
Dimensions
Contact Data
Inductive :20A/250VAC,cos =0.7
1
12
HP 250VAC
TV-15
Max. Switching Current:25A rushing current:80A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
Coil Parameter
Max
5
6
9
12
24
48
110
5.5
6.6
9.9
13.2
26.4
52.8
121
Pick up
voltage
VDC(max)
(75% of rated
voltage )
Release
voltage
VDC(min)
(10% of rated
voltage)
27.7
40
90
160
640
2560
13440
3.75
4.5
6.75
9.00
18.00
36.00
82.50
0.5
0.6
0.9
1.2
2.4
4.8
11.0
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
0.9
20
10
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
20
0.787
22
0.866
30.4max.
0.197max.
2.1
0.083
2-0.8 1.5
0.031 0.059
2.5
0.098
24.5
0.965
28.5max.
1.122max.
2-0.3 1.4
0.012 0.055
Dimensions
20
0.787
2.5
0.098
Rated
Coil
resistance
10%
2.1
0.083
005-900
006-900
009-900
012-900
024-900
048-900
110-900
Coil voltage
VDC
24.5
0.965
Dash
numbers
4.9
0.193
0.8
0.031
18
0.709
6380VA 750W
300VAC 30VDC
50m
105
107
6.8
0.268
6.3
0.248
18.5max.
9.9
0.728max. 0.390
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation
Electrical
life
Mechanical
15
0.591
1.5
0.059
1A SPSTNO
AgSnO2 AgCdO
Resistive: 25A/277VAC, 30VDC
4.3
0.169
1
0.039
Contact Arrangement
Contact Material
Contact Rating
4.9
0.193
22
0.866
4- 1.8
0.071
Wiring diagram(Bottom view)
Mounting (Bottom view)
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
Ningbo Forward Relay Corporation LTD.
112
JQX- 54W
JQX- 54W
Operation condition
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
04001010696
R
on Pending
30.4 28.5 18.5
C
US
Shock resistance
E160644
Vibration resistance
Features
Can be welded directly onto PCB.
Compact high capacity relay for inductive load, rushing current of 80A and steady-state current of 25A.
Used in household appliances like air conditioning , heater and instruments etc.
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
1000M
min (at 500VDC)
Item 7 of IEC255-5
50Hz 1200V
50Hz 3600V
surge voltage:10kV
Functional:100m/s2
11ms
Survival:1000 m/s2 11ms
10~55Hz
double amplitude Functional 1.0mm
double amplitude Survival 2.0mm
10N 8N
235
2
3 0.5s
-40~85
20~85%
31.5g
Item 6 of IEC255-5
Item 6 of IEC255-5
Item 8 of IEC255-5
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1 and Ua2
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table
Ordering Information
JQX-54W A 25
1
2
DC12V C B
3
4
5
Safety approval
6
1 Part number JQX-54W
2 Contact arrangement A:1A
3 Contact rating Resistive: 25A/277VAC 30VDC
Inductive:20A/250VAC cos =0.7
of IEC255-19-1 and minimum sample size 24.
Safety approvals
UL&CUR
Load
4 Coil rated voltage(V) DC:5,6,9,12,24,48,110
5 Contact material C:AgCdO NIL:AgSnO2
6 Resistance heat class B:130
F:155
25A/277VAC
1
12
CQC
25A/250VAC
HP250VAC 1HP125VAC
mm /inch
Dimensions
Contact Data
Inductive :20A/250VAC,cos =0.7
1
12
HP 250VAC
TV-15
Max. Switching Current:25A rushing current:80A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
Coil Parameter
Max
5
6
9
12
24
48
110
5.5
6.6
9.9
13.2
26.4
52.8
121
Pick up
voltage
VDC(max)
(75% of rated
voltage )
Release
voltage
VDC(min)
(10% of rated
voltage)
27.7
40
90
160
640
2560
13440
3.75
4.5
6.75
9.00
18.00
36.00
82.50
0.5
0.6
0.9
1.2
2.4
4.8
11.0
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
0.9
20
10
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
20
0.787
22
0.866
30.4max.
0.197max.
2.1
0.083
2-0.8 1.5
0.031 0.059
2.5
0.098
24.5
0.965
28.5max.
1.122max.
2-0.3 1.4
0.012 0.055
Dimensions
20
0.787
2.5
0.098
Rated
Coil
resistance
10%
2.1
0.083
005-900
006-900
009-900
012-900
024-900
048-900
110-900
Coil voltage
VDC
24.5
0.965
Dash
numbers
4.9
0.193
0.8
0.031
18
0.709
6380VA 750W
300VAC 30VDC
50m
105
107
6.8
0.268
6.3
0.248
18.5max.
9.9
0.728max. 0.390
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation
Electrical
life
Mechanical
15
0.591
1.5
0.059
1A SPSTNO
AgSnO2 AgCdO
Resistive: 25A/277VAC, 30VDC
4.3
0.169
1
0.039
Contact Arrangement
Contact Material
Contact Rating
4.9
0.193
22
0.866
4- 1.8
0.071
Wiring diagram(Bottom view)
Mounting (Bottom view)
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
111
Ningbo Huaguan Relay Corporation LTD.