JQX- 102F CH0064847—2001 30.5×16.0×23.5 R2133344 30.5×16.0×26.5 Features Can be welded directly onto PCB. Used in household appliance like air conditioning , heater and instruments etc. Ordering Information JQX-102F A Z 20 b DC12V 0.9 1 2 3 4 5 6 1 Part number:JQX-102F 2 Contact arrangement:A:1A 3 Enclosure:Z: Dust cover 7 4 Contact rating:Resistive:20A/250VAC; 5 Terminal:b:PC type;NIL:PC type and QC type 6 Coil rated Voltage(V):DC:5,12,24,48 7 Coil power consumption:0.9:0.9W Contact Data Contact Arrangement Contact Material Contact Rating( Resistive) Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical life Mechanical 1ASPSTNO AgSnO2 20A/250VAC 5000VA 300VAC አ30m (at 1A/14VDC) 105 2106 Max. Switching Current:20A Item 3.12 of IEC255-7 Item 3.30 of IEC255-7 Item 3.31 of IEC255-7 Coil Parameter Dash numbers Coil voltage VDC Coil resistance ±10% Pickup voltage VDC(max) (70%of rated voltage ) release voltage VDC(min) (10% of rated voltage) Rated Max. 005-900 5 6 27.8 3.5 0.5 012-900 12 14.4 160 8.4 1.2 024-900 24 28.8 640 16.8 2.4 048-500 48 57.6 2560 33.6 4.8 Coil power consumption W Operate Time ms Release Time ms 0.9 20 10 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. 99 www.dblectro.com JQX-102F Operation condition Insulation Resistance Dielectric Strength Between contacts Between contact and coil Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 1000M min (at 500VDC) Item 7 of IEC255-5 50Hz 1500V 50Hz 4500V surge voltage:10kV Functional:200m/s2 11ms Survival:1000 m/s2 11ms 10~55Hz double amplitude Functional 1.5mm double amplitude Survival 2.0mm 10N 8N 2352 30.5s -25~55 85% (at 40) 23g Item 6 Item 6 Item 8 of IEC255-5 of IEC255-5 of IEC255-5 IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 and Ua2 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca Qualification inspection: Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24. Safety approvals Safety approval Load CCEE 20A/250VAC TüV 20A/250VAC COS=0.9 Dimensions (Unit: mm) × ×0.8 × ×0.8 Dimensions Mounting (Bottom views) Wiring diagram (Bottom views) mm 0.3 0.5 0.8 1.4 1.5 1.8 2 3.2 3.4 3.5 5.2 6.2 6.3 6.4 8.3 8.4 9.4 10 10.2 12 16 18.4 22 23.5 26.5 27.6 30.5 NOTES 1).Dimensions are in millimeter. 2).Inch equivalents are given for general information only. www.dblectro.com >àçÇá 0.012 0.020 0.031 0.055 0.059 0.071 0.079 0.126 0.134 0.138 0.205 0.244 0.248 0.252 0.327 0.331 0.370 0.394 0.402 0.472 0.630 0.724 0.866 0.925 1.043 1.087 1.201