Axial-Lead and Soldering Star Capacitors B41693 Up to 150 °C B41793 B41693, B41793 SIKOREL® Applications ■ Excellent reliable design for automotive applications Features ■ ■ ■ ■ ■ ■ ■ ■ High operating temperature capability Low ESR Extremly high reliability Outstanding parametric stability High ripple current capability High vibration resistance Long useful life Shelf life up to 15 years KAL0573-K Construction ■ Charge-discharge proof, polar ■ Aluminum case with insulating sleeve ■ Negative pole connected to case Terminals ■ Axial leads, welded to ensure perfect electrical contact ■ Also available with soldering stars Taping and packing ■ Axial-lead capacitors will be delivered in pallet package. Capacitors with d × l ≤ 16 × 30 mm are also available taped on reel. ■ Solder-star capacitors are packed in cardboard. For details on taping and packing, refer to page 342. 306 10/02 B41693 / B41793 Up to 150 °C Specifications and characteristics in brief Rated voltage UR 25 … 100 VDC Surge voltage US Rated capacitance CR 1,15 · UR 100 … 1 500 µF Capacitance tolerance – 10/+ 30 % Leakage current IL Q (5 min, 20 °C) C R U Rö ⋅ ------- + 4 µA I L ≤ 0,006 µA ⋅ æè ------µF V ø Self-inductance ESL1) Diameter d Useful life 150 °C; UR; 0,5 I~R 125 °C; UR; I~R 85 °C; UR; I~max 40 °C; UR; 2,1 · I~R 12 mm 14 mm 16 mm 18 mm —/— Length l Terminal Approx. ESL (nH) 25 mm axial / solder star —/— 22 / 6 26 / 7 30 mm axial / solder star 21 / 6 24 / 7 29 / 8 34 / 10 39 mm axial / solder star —/— —/— 33 / 9 38 / 11 25...90 VDC > 1 000 h > 5 000 h > 15 000 h > 200 000 h 100 VDC Requirements: > 1 000 h*) ∆C/C ≤ ± 30 % of initial value > 3 000 h ESR ≤ 3 times of initial specified limit > 8 000 h IL ≤ initial specified limit > 200 000 h Failure *) for 140 °C percentage: ≤ 0,5 % Failure rate: ≤ 10 fit (≤ 10 · 10 –9/h) (for definiton “fit”, refer to chapter “Quality”, page 62) Voltage endurance test Post test requirements: ∆C/C ESR IL ≤ ± 10 % of initial value ≤ 1,3 % of initial specified limit ≤ initial specified limit 125 °C; UR 2 000 h Vibration resistance To IEC 60068-2-6, test Fc: displacement amplitude 1,5 mm, at 10 Hz to 2 kHz, acceleration max. 20 g, duration 3 × 2 h IEC climatic category To IEC 60068-1: 55/125/56 (–55 °C/+125 °C/56 days damp heat test) Detail specification Similar to CECC 30301-802 Sectional specification IEC 60384-4 1) If optimum circuit design is used, the values are lower by 30 %. 307 10/02 B41693 / B41793 Up to 150 °C Dimensional drawings Axial-lead capacitor 40 _ 5 40 _ 5 max _ 0,02 ø1+0,04 d max max +1,5 max +4 1,3+0,1 KAL0524-S Dimensions, weights and packing units d×l mm dmax × lmax mm Approx. weight g Packing units (pieces) Pallet Reel 12 × 30 12,5 × 30,5 5,1 288 450 14 × 25 14 × 30 14,5 × 25,5 14,5 × 30,5 5,7 6,8 200 200 350 350 16 × 25 16 × 30 16,5 × 25,5 16,5 × 30,5 7,4 8,9 180 180 250 250 16 × 39 16,5 × 40 11,7 180 — 18 × 30 18,5 × 30,5 11,1 160 — 18 × 39 18,5 × 40 14,7 160 — 308 10/02 B41693 / B41793 Up to 150 °C Soldering star capacitors Mounting holes d = 12 mm ... 14 mm 0,6 3±0,1 d max c ±0,1 ø1,3+0,1 4,7 _ 0,5 360 ˚ 3 c ±0,1 3,1_ 0,2 max Mounting holes d = 16 mm ... 18 mm ø1,3+0,1 Soldering star is connected to the negative pole _ 0,02 ø1+0,04 KAL0525-1-E The PC-board hole arrangement specified above is based on circular arcs. If, however, the mounting holes have to be matched to a standard drilling raster, a spacing of 1,27 mm (1/20″) has proved to be sufficiently accurate if the following arrangements are used: d = 14 mm d = 12 mm KAL0357-R 1,27 d = 18 mm d = 16 mm ø1,5+0,1 KAL0356-I KAL0359-8 KAL0358-Z Dimensions, weights and packing units d×l dmax × lmax c ± 0,1 Approx. weight Packing units mm mm 12 × 30 13,5 × 32 mm 12,5 g 5,4 pieces 480 14 × 25 14 × 30 15,5 × 27 15,5 × 32 14,5 14,5 6,1 7,2 480 480 16 × 25 16 × 30 17,5 × 27 17,5 × 32 16,5 16,5 7,9 9,4 300 300 16 × 39 18 × 30 17,5 × 41,5 19,5 × 32 16,5 18,5 12,2 11,8 200 300 18 × 39 19,5 × 41,5 18,5 15,4 200 309 10/02 B41693 / B41793 Up to 150 °C Overview of available types UR (VDC) 25 CR (µF) 100 150 220 330 470 1 000 1 500 Case dimensions d × l (mm) 40 63 75 100 12 ×30 12 × 30 14 × 25 16 × 25 14 × 30 16 × 30 16 × 39 18 × 39 12 ×30 14 × 25 16 × 30 18 × 30 16 × 39 18 × 39 18 × 39 Case dimensions and ordering codes UR CR VDC µF 25 40 470 1 000 1 500 330 1 000 1 500 63 75 100 220 470 100 220 470 100 100 150 330 Case dim. d×l mm 14 × 25 16 × 30 16 × 39 12 × 30 18 × 30 18 × 39 12 × 30 14 × 30 16 × 39 12 × 30 16 × 30 18 × 39 14 × 25 16 × 25 18 × 39 Ordering code Axial pallet package Axial reel Soldering star B41693A5477Q007 B41693A5108Q007 B41693A5477Q009 B41693A5108Q009 B41793A5477Q000 B41793A5108Q000 B41693A5158Q007 B41693A7337Q007 B41693A7337Q009 B41793A5158Q000 B41793A7337Q000 B41693A7108Q007 B41693A7158Q007 B41793A7108Q000 B41793A7158Q000 B41693A8107Q007 B41693A8227Q007 B41693A8107Q009 B41693A8277Q009 B41793A8107Q000 B41793A8227Q000 B41693A8477Q007 B41693A0107Q007 B41693A0107Q009 B41793A8477Q000 B41793A0107Q000 B41693A0227Q007 B41693A0227Q009 B41693A0477Q007 B41693A9107Q007 B41693A9157Q007 B41793A0227Q000 B41793A0477Q000 B41693A9107Q009 B41693A9157Q009 B41693A9337Q007 310 10/02 B41793A9107Q000 B41793A9157Q000 B41793A9337Q000 B41693 / B41793 Up to 150 °C Technical data CR 100 Hz 20 °C µF ESRtyp 100 Hz 20 °C mΩ ESR max 100 Hz 20 °C mΩ ESRmax 100 Hz −40 °C Ω ESR max 10 kHz 20 °C mΩ Zmax 100 kHz 20 °C mΩ I~max 10 kHz 40 °C A I~max 10 kHz 85 °C A I ~R 10 kHz 125 °C A I~max 10 kHz 150 °C A 470 1 000 200 90 320 150 1,90 0,90 190 100 180 92 3,80 6,00 3,55 5,50 1,60 2,50 0,80 1,25 1 500 60 100 0,60 70 65 8,30 7,70 3,45 1,72 250 80 55 400 130 90 2,50 0,70 0,50 200 80 55 190 76 52 3,80 7,60 9,20 3,55 6,10 8,50 1,60 2,75 3,80 0,80 1,37 1,90 25 VDC 40 VDC 330 1 000 1 500 63 VDC 100 500 800 3,30 280 270 3,30 3,00 1,35 0,67 230 110 380 170 1,70 0,90 135 68 130 65 4,90 8,20 4,60 7,60 2,05 3,40 1,02 1,70 75 VDC 100 420 700 3,00 225 220 3,60 3,35 1,50 0,75 330 150 1,50 0,70 115 60 110 56 5,70 9,20 5,20 8,50 2,35 3,80 1,17 1,90 220 470 220 470 200 90 100 VDC 100 430 150 330 280 120 900 3,40 300 270 3,80 3,30 1,45 — 550 250 2,10 1,00 200 90 180 80 4,65 8,80 4,00 7,60 1,75 3,35 — — 311 10/02 B41693 / B41793 Up to 150 °C Useful life depending on ambient temperature TA under ripple current operating conditions 1) UR < 100 V or UR = 100 V and operating voltage Uop ≤ 90 V KAL0562-5 3,0 Ι~ Ι ~R B41693/793 2,5 2,0 1,5 0 40 50 60 70 80 90 100 110 120 130 140 1 000 h 3 000 h 5 000 h 10 000 h 30 000 h 0,5 100 000 h 500 000 h 1,0 ˚C 160 TA Useful life depending on case temperature TC under ripple current operating conditions 1) UR < 100 V or UR = 100 V and operating voltage Uop ≤ 90 V KAL0563-D 3,0 Ι~ Ι ~R B41693/793 2,5 2,0 1,5 0 40 50 60 70 80 90 100 110 120 130 140 1 000 h 3 000 h 5 000 h 10 000 h 30 000 h 0,5 100 000 h 500 000 h 1,0 ˚C 160 TC 1) Refer to page 40 for an explanation on how to interpret the useful life graphs. 312 10/02 B41693 / B41793 Up to 150 °C Useful life depending on temperature TA under ripple current operating conditions 1) UR = 100 V KAL0564-L 3,0 Ι~ Ι ~R B41693/793 2,5 2,0 1,5 0 40 50 60 70 80 90 100 110 120 130 1 000 h 2 000 h 3 000 h 10 000 h 30 000 h 0,5 100 000 h 500 000 h 1,0 ˚C 150 TA Useful life depending on case temperature TC under ripple current operating conditions 1) UR = 100 V KAL0565-U 3,0 Ι~ Ι ~R B41693/793 2,5 2,0 1,5 0 40 50 60 70 80 90 100 110 120 130 1 000 h 2 000 h 3 000 h 10 000 h 30 000 h 0,5 100 000 h 500 000 h 1,0 ˚C 150 TC 1) Refer to page 40 for an explanation on how to interpret the useful life graphs. 313 10/02 B41693 / B41793 Up to 150 °C Frequency characteristics of ESR at different temperatures Typical behavior Frequency factor of permissible ripple current I~ versus frequency f KAL0611-2 1,2 Ι ~f B41693/793 Ι ~10 kHz 7 ESR f ESR 10 kHz 0,9 125 ˚C 85 ˚C 5 0,8 b c d e 0,7 0,6 0,5 4 20 ˚C ø [mm] UR 25 VDC 40 VDC 63 VDC 75 VDC 100 VDC 0,4 0,3 0,2 0,1 0 2 10 5 3 12 14 16 18 c d e e c c d e e c 10 3 b c d e c 2 b c d d c 0 1 10 5 10 2 5 10 3 Hz 10 4 f Impedance Z versus frequency f at different temperatures Typical behavior for 470 µF/63 V KAL0613-I 10 1 _ 40 ˚C 1 5 Hz 10 4 f Equivalent series resistance ESR versus frequency f at different temperatures Typical behavior for 470 µF/63 V KAL0614-R 10 1 B41693/793 Ω KAL0612-A B41693/793 B41693/793 Ω Z ESR 10 0 10 0 _ 40 ˚C 5 _ 40 ˚C 5 _ 20 ˚C 10 _ 20 ˚C _1 10 20 ˚C 5 _1 20 ˚C 5 >_ 60 ˚C 10 >_ 60 ˚C _2 10 1 5 10 2 5 10 3 5 10 4 Hz 10 5 f 10 _2 314 10/02 10 1 5 10 2 5 10 3 5 10 4 Hz 10 5 f Herausgegeben von EPCOS AG Unternehmenskommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND ++49 89 636 09, FAX (0 89) 636-2 26 89 ( EPCOS AG 2002. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschüre ersetzt die vorige Ausgabe. Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen. Published by EPCOS AG Corporate Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY ++49 89 636 09, FAX (0 89) 636-2 26 89 ( EPCOS AG 2002. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices.