EPCOS B84142-A1000-S3

2-Line Filters
B84142-A*-S2
for Converters in Traction Systems
... B84142-A*-S18
Power line filters for dc systems
Rated voltage 750 to 2000 V–
Rated current 250 to 1000 A
Construction
■ Two-line filter
■ Metal case
Features
■ Easy to install
■ Space-saving design
■ Design based on
EN 133 200, UL 1283, CSA 22.2 No.8 1986
■ Optimized for long motor cables and
operation under full load
Applications
■ Trams, light rails
■ Subways
Terminals
■ Busbars, tin-plated
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated voltage, rated current,
date code
Minimum marking on packaging:
Manufacturer’s logo, ordering code
Typical circuit diagram
L+
L+’
L_
L _’
LINE
LOAD
Traction
Bahnseite side
Inverter
Umrichter
183 03/01
SSB1309-8
2-Line Filters
B84142-A*-S2
for Converters in Traction Systems
... B84142-A*-S18
Technical data
Rated voltage V R
750 V− (Type -S2)
1000 V− (Type -S3)
2000 V− (Type -S18)
Rated current IR
Referred to 60 °C ambient temperature
Test voltage VP
For 750 V− filters:
2000 V−, 60 s (L+/L−)
4900 V−, 60 s (L+||L−/case)
6000 V−, 2 s (L+||L−/case)
For 1000 V− filters: 2500 V−, 60 s (L+/L−)
4900 V−, 60 s (L+||L−/case)
6000 V−, 2 s (L+||L−/case)
For 2000 V− filters: 4000 V−, 60 s (L+/L−)
4900 V−, 60 s (L+||L−/case)
6000 V−, 2 s (L+||L−/case)
Overload capability
1,6 · IR for 20 s or
2,0 · IR for 10 s
Climatic category
40/100/21 (– 40 °C/+ 100 °C/21 days damp heat test)
in accordance with EN 60068-1
Characteristics and ordering codes
VR
IR
V−
A
750
1000
2000
Terminal
PV
cross section
mm2
W
R typ
250
125
8
63
12
B84142-A250-S2
500
150
34
57
13
B84142-A500-S2
1000
320
66
33
26
B84142-A1000-S2
250
125
8
63
12
B84142-A250-S3
500
150
34
57
13
B84142-A500-S3
1000
320
66
33
26
B84142-A1000-S3
250
125
8
63
12
B84142-A250-S18
µΩ
Approx.
weight
kg
Ordering code
500
150
34
57
13
B84142-A500-S18
1000
320
66
33
26
B84142-A1000-S18
184 03/01
2-Line Filters
B84142-A*-S2
for Converters in Traction Systems
... B84142-A*-S18
Dimensional drawing B84142-A250-S**
PE
M10 × 30
PE
M10 × 30
25
ø11
5
5
40±1
40±1
15
15
360±2
91
300
60
36
120±0,5
60
120±0,5
+
2
2xM6;depth
2 × M6; 6 ofmm tief
engagement
an beiden 6 mm
on
both filter sides
Stirnseiten
LINE
LOAD
_
190
Marking
_
165±1
80
30
140
110±0,5
5
+
ø12
91
116
SSB1587-R
185 03/01
2-Line Filters
B84142-A*-S2
for Converters in Traction Systems
... B84142-A*-S18
Dimensional drawing B84142-A500-S**
PE
M10 × 30
PE
M10 × 30
30
ø11
5
5
40±1
40±1
15
15
360±2
91
300
60
36
120±0,5
60
120±0,5
+
2
2xM6;depth
2 × M6; 6 of
mm tief
engagement
an beiden 6 mm
on
both filter sides
Stirnseiten
LINE
LOAD
_
190
Marking
_
165±1
80
30
140
110±0,5
5
+
ø12
91
116
SSB1588-Z
186 03/01
2-Line Filters
B84142-A*-S2
for Converters in Traction Systems
... B84142-A*-S18
B84142-A1000-S**
86±3
86±3
ø14
40
ø14
20
20
40
410±2,5
40
350
60
61
290±1
PE
M6 × 25
+
2
95±0,8
_
LINE
LOAD
_
260
Marking
235±1
8
80
180±0,8
210
+
4xM6;depth
of tief
4 × M6; 6 mm
engagement
an beiden 6 mm
on
both filter sides
Stirnseiten
60
220
ø12
16
126
SSB1589-8
187 03/01
2-Line Filters
B84142-A*-S2
for Converters in Traction Systems
... B84142-A*-S18
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
B84142-A250-S2 ... -S18
B84142-A500-S2 ... -S18
B84142-A1000-S2 ... -S18
SSB1573-L
100
dB
SSB1574-U
100
dB
αe
αe
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
10
0
10 4
10 5
10 6
10 7
Hz 10 8
f
0 4
10
188 03/01
10 5
10 6
10 7
Hz 10 8
f
Herausgegeben von EPCOS AG
Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND
 EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und
Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG
nicht gestattet.
Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften
zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen
für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird.
Diese Broschüre ersetzt die vorige Ausgabe.
Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland.
Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte
darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen.
Published by EPCOS AG
Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY
 EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited.
The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for
the Supply of Products and Services of the Electrical and Electronics Industry recommended by the
ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our Sales Offices.
1