MCC MBR20120CT

MCC
TM
Micro Commercial Components
omponents
20736 Marilla Street Chatsworth
!"#
$
% !"#
Features
•
•
MBR20120CT
20 Amp High Voltage
High Junction Temperature Capability
Good Trade Off Between Leakage Current And Forward Volage Drop
Low Leakage Current
•
Power Schottky
Barrier Rectifier
120Volts
Maximum Ratings
•
•
•
Operating J unction Temperature : 150°C
Storage Temperature: - 5 0°C to +150°C
Per d iode Thermal Resistance 2.2°C/W Junction to Case
TO-220AB
B
L
M
MCC
Catalog
Number
MBR 20120 CT
Maximum
Recurrent
Peak Reverse
Voltage
120 V
Maximum
RMS
Voltage
84V
Maximum
DC
Blocking
Voltage
120 V
C
D
A
K
E
PIN
1
3
F
G
I
J
N
H H
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum
Instantaneous
Forward Voltage
Maximum
Reverse Current At
Rated DC Blocking
IF(AV)
IFSM
20 A
150A
PIN 1
TC = 120°C
PIN 2
CASE
PIN 3
8.3ms, half
sine wave
VF
.83 V
IR
500 µ A
IFM = 10A
TJ = 100°C
TJ = 25°C
A
B
C
D
E
F
G
H
I
J
K
L
M
N
INCHES
.570
.620
.380
.405
.100
.120
.235
.255
.335
.365
.110
.155
.500
.562
.095
.105
.025
.035
.016
.025
.142
.147
.160
.190
.045
.055
0.102t y p.
MM
14.48
15.75
9.66
10.28
2.54
3.04
5.97
6.48
8.51
9.27
2.80
3.93
12.70
14.27
2.42
2.66
0.64
0.89
0.41
0.64
3.61
3.73
4.06
4.82
1.14
1.39
2.6t yp .
* Pulse Test: Pulse Width380µsec, Duty Cycle 2%
Revision: 2
www.mccsemi.com
2003/07/07
MCC
MBR20120CT
Figure 1
Typical Forward Characteristics
100
INSTANTANEOUS FORWARD CURRENT ,(A)
TM
Figure 2
Micro Commercial Components
Typical Reverse Characteristics
10
6
4
2
10
1
.6
.4
1.0
.2
TA=25°C
µAmps .1
TJ = 25 C
.06
PULSE WIDTH 380us
2% Duty cycle
0.1
.04
0.3
0.2
0.4
0.5
0.7
0.6
0.8
INSTANTANEOUS FORWARD VOLTAGE , VOLTS
.02
.01
.006
.00
4
.002
.001
20
75
50
100
125 150
175
Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 3
Forward Derating Curve
Figure 4
Peak Forward Surge Current
20
150
18
125
16
100
75
14
Amps
Amps
50
12
25
10
0
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
0
25
50
75
100
125
1
2
4
8 10
20
40
60 80 100
Cycles
150
°C
6
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C
Revision: 2
www.mccsemi.com
2003/07/07