MICREL SY10E175JC

SY10E175
9-BIT LATCH
WITH PARITY
Micrel, Inc.
FEATURES
■
■
■
■
■
■
■
■
SY100E175
SY10E175
SY100E175
DESCRIPTION
9-bit latch
Extended 100E VEE range of –4.2V to –5.5V
Parity detection/generation
800ps max. D to Output
Reset
Internal 75KΩ input pull-down resistors
Fully compatible with Motorola MC10E/100E175
Available in 28-pin PLCC package
The SY10/100E175 are 9-bit latches. They also feature
a tenth latched output (ODDPAR) which is formed as the
odd parity of the nine data inputs (ODDPAR is HIGH if
an odd number of the inputs are HIGH).
The E175 can also be used to generate byte parity by
using D8 as the parity-type select (L = even parity, H =
odd parity) and using ODDPAR as the byte parity output.
The LEN pin latches the data when asserted with a
logical high and makes the latch transparent when placed
at a logic low level.
PIN NAMES
BLOCK DIAGRAM
Pin
D0
D
Q
Q0
EN
R
bits
1–7
D8
D
Q
Q8
Q
ODDPAR
Function
D0 – D8
Data Inputs
LEN
Latch Enable
MR
Master Reset
Q0 – Q8
Data Outputs
ODDPAR
Parity Output
VCCO
VCC to Output
EN
R
D
EN
R
LEN
MR
M9999-032006
[email protected] or (408) 955-1690
Rev.: F
1
Amendment: /0
Issue Date: March 2006
SY10E175
SY100E175
Micrel, Inc.
Ordering Information(1)
Q7
VCCO
Q8
D8
VCCO
D6
D7
PACKAGE/ORDERING INFORMATION
25 24 23 22 21 20 19
D5
D4
D3
VEE
LEN
26
18
27
17
28
16
TOP VIEW
PLCC
J28-1
1
2
15
14
6
7
9
10 11
VCCO
Q1
5
VCCO
12
ODDPAR
Q0
13
4
D1
3
D2
D0
MR
8
Q6
Q5
VCC
Q4
Q3
VCCO
Q2
Part Number
Package
Type
Operating
Range
Package
Marking
Lead
Finish
SY10E175JC
J28-1
Commercial
SY10E175JC
Sn-Pb
SY10E175JCTR(2)
J28-1
Commercial
SY10E175JC
Sn-Pb
SY100E175JC
J28-1
Commercial
SY100E175JC
Sn-Pb
SY100E175JCTR(2)
J28-1
Commercial
SY100E175JC
Sn-Pb
SY10E175JZ(3)
J28-1
Commercial
SY10E175JZ with
Pb-Free bar-line indicator
Matte-Sn
SY10E175JZTR(2, 3)
J28-1
Commercial
SY10E175JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100E175JZ(3)
J28-1
Commercial
SY100E175JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100E175JZTR(2, 3)
J28-1
Commercial
SY100E175JZ with
Pb-Free bar-line indicator
Matte-Sn
28-Pin PLCC (J28-1)
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-032006
[email protected] or (408) 955-1690
2
SY10E175
SY100E175
Micrel, Inc.
TRUTH TABLE
D
LEN
MR
Q
ODDPAR
H
L
L
H
H if odd no. of Dn HIGH
H if odd no. of Dn HIGH
L
L
L
L
X
H
L
Q0
X
X
H
L
Q0
L
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
Parameter
IIH
Input HIGH Current
IEE
Power Supply Current
10E
100E
TA = +25°C
TA = +85°C
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
Condition
—
—
150
—
—
150
—
—
150
µA
—
mA
—
—
—
110
110
132
132
—
—
110
110
132
132
—
—
110
127
132
152
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
TA = +25°C
TA = +85°C
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Propagation Delay to Output
D to Q
D to ODDPAR
LEN to Q
LEN to ODDPAR
MR to Q (tPHL)
MR to ODDPAR (tPHL)
450
850
525
525
525
525
600
1150
700
700
700
700
800
1450
900
900
900
900
450
850
525
525
525
525
600
1150
700
700
700
700
800
1450
900
900
900
900
450
850
525
525
525
525
600
1150
700
700
700
700
800
1450
900
900
900
900
Set-up Time
D (Q)
D (ODDPAR)
275
900
100
700
—
—
275
900
—
—
—
—
275
900
—
—
—
—
Hold Time
D (Q)
D (ODDPAR)
175
–300
–100
–700
—
—
175
–300
—
—
—
—
175
–300
—
—
—
—
tRR
Reset Recovery Time
850
600
—
850
600
—
850
600
—
tskew
Within-Device Skew
LEN, MR
D to Q
D to ODDPAR
—
—
—
75
75
200
—
—
—
—
—
—
75
75
200
—
—
—
—
—
—
75
75
200
—
—
—
300
500
800
300
500
800
300
500
800
tPD
tS
tH
tr
tf
Rise/Fall Times
20–80%
Note:
1. Within-device skew is defined as identical transitions on similar paths
through a device.
M9999-032006
[email protected] or (408) 955-1690
3
Unit
Condition
ps
—
ps
—
ps
—
ps
—
ps
1
ps
—
SY10E175
SY100E175
Micrel, Inc.
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-032006
[email protected] or (408) 955-1690
4