FEATURES ■ ■ ■ ■ ■ ■ ■ ■ SY100H606 DESCRIPTION Differential 50Ω ECL outputs Choice between differential PECL or TTL clock input Single +5V power supply VBB output for single-ended use Multiple power and ground pins to minimize noise Specified within-device skew Fully compatible with MC10H/100H606 Available in 28-pin PLCC package The SY10/100H606 are 6-bit, registered, single supply TTL-to-PECL translators. The devices feature differential PECL outputs as well as a choice between either a differential PECL clock input or a TTL clock input. The asynchronous master reset control is a PECL level input. With its differential ECL outputs and TTL inputs, the H606 device is ideally suited for the transmit function of a HPPI bus-type board-to-board interface application. The on-chip registers simplify the task of synchronizing the data between the two boards. The device is available in either ECL standard: the 10H device is compatible with 10K logic levels, while the 100H device is compatible with 100K logic levels. PIN NAMES BLOCK DIAGRAM Pin 1 OF 6 BITS Dn SY10H606 SY100H606 SY10H606 REGISTERED HEX TTL-TO-PECL Micrel, Inc. D Q Function D0 – D5 TTL Data Inputs CLK, CLK Differential PECL Clock Inputs TCLK TTL Clock Input Qn MR PECL Master Reset Input Qn Q0 – Q5 True PECL Outputs Q0 – Q5 Inverted PECL Outputs VCCE PECL VCC (5.0V) VCCT TTL VCC (5.0V) GND TTL/PECL Ground VBB VBB Reference Output (PECL) CLK R CLK CLK TCLK MR VBB M9999-032906 [email protected] or (408) 955-1690 1 Rev.: E Amendment: /0 Issue Date: March 2006 SY10H606 SY100H606 Micrel, Inc. Ordering Information(1) VCCE D4 D5 D2 VCCT D3 D1 PACKAGE/ORDERING INFORMATION Part Number Package Type Operating Range Package Marking Lead Finish SY10H606JC J28-1 Commercial SY10H606JC Sn-Pb 25 24 23 22 21 20 19 D0 26 18 Q5 TCLK VBB 27 17 28 16 Q5 Q4 TOP VIEW PLCC CLK CLK 2 14 MR 3 13 Q4 VCCE Q3 VCCE 4 12 Q3 Q0 6 7 8 9 Q0 GND Q1 Q1 5 15 10 11 J28-1 Commercial SY10H606JC Sn-Pb SY100H606JC J28-1 Commercial SY100H606JC Sn-Pb SY100H606JCTR(2) J28-1 Commercial SY100H606JC Sn-Pb SY10H606JZ(3) J28-1 Commercial SY10H606JZ with Matte-Sn Pb-Free bar-line indicator SY10H606JZTR(2, 3) J28-1 Commercial SY10H606JZ with Matte-Sn Pb-Free bar-line indicator SY100H606JZ(3) J28-1 Commercial SY100H606JZ with Matte-Sn Pb-Free bar-line indicator SY100H606JZTR(2, 3) J28-1 Commercial SY100H606JZ with Matte-Sn Pb-Free bar-line indicator Q2 Q2 1 SY10H606JCTR(2) 28-Pin PLCC (J28-1) Notes: 1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only. 2. Tape and Reel. 3. Pb-Free package is recommended for new designs. M9999-032906 [email protected] or (408) 955-1690 2 SY10H606 SY100H606 Micrel, Inc. TRUTH TABLE Dn MR TCLK/CLK Qn + 1 L L Z L H L Z H X H X L Z = Low to High Transition. DC ELECTRICAL CHARACTERISTICS VCCT = VCCE = 5.0V ±5% TA= 0°C Symbol Parameter TA= +25°C TA= + 85°C Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit 30 mA Outputs LOW Outputs HIGH ICCTL Supply Current — 18 30 — 18 30 — 18 ICCTH Supply Current — 13 25 — 13 25 — 13 25 mA IGND Supply Current — 75 90 — 75 90 — 75 95 mA Condition TTL DC ELECTRICAL CHARACTERISTICS VCCT = VCCE = 5.0V ±5% TA= 0°C Symbol Parameter TA= +25°C TA= + 85°C Min. Max. Min. Max. Min. Max. Unit — 2.0 — 2.0 — V Condition VIH Input HIGH Voltage 2.0 VIL Input LOW Voltage — 0.8 — 0.8 — 0.8 V VIK Input Clamp Voltage — –1.2 — –1.2 — –1.2 V IIN = –18mA IIH Input HIGH Current — — 20 100 — — 20 100 — — 20 100 µA VIN = 2.7V VIN = 7.0V IIL Input LOW Current — –0.6 — –0.6 — –0.6 mA VIN = 0.5V 10H PECL DC ELECTRICAL CHARACTERISTICS(1) VCCT = VCCE = 5.0V ±5% TA= 0°C Symbol Parameter TA= +25°C TA= + 85°C Min. Max. Min. Max. Min. Max. Unit IIH Input HIGH Current — 225 — 145 — 145 µA IIL Input LOW Current 0.5 — 0.5 — 0.5 — µA VIH Input HIGH Voltage 3830 4160 3870 4190 3930 4280 mV VCCT = 5.0V VIL Input LOW Voltage 3050 3520 3050 3520 3050 3555 mV VCCT = 5.0V VOH Output HIGH Voltage 3980 4160 4020 4190 4080 4270 mV VCCT = 5.0V VOL Output LOW Voltage 3050 3370 3050 3370 3050 3400 mV VCCT = 5.0V VBB Output Bias Voltage 3620 3730 3650 3750 3690 3810 mV VCCT = 5.0V Note: 1. PECL VIL, VIH, VOL, VOH, VBB are given for VCCT = VCCE = 5.0V and will vary 1:1 with power supply. M9999-032906 [email protected] or (408) 955-1690 3 Condition SY10H606 SY100H606 Micrel, Inc. 100H PECL DC ELECTRICAL CHARACTERISTICS(1) VCCT = VEEC = 5.0V ±5% TA= 0°C Symbol Parameter Min. Max. TA= +25°C TA= + 85°C Min. Max. Min. Max. Unit Condition IIH Input HIGH Current — 225 — 145 — 145 µA IIL Input LOW Current 0.5 — 0.5 — 0.5 — µA VIH Input HIGH Voltage 3835 4120 3835 4120 3835 4120 mV VCCT = 5.0V VIL Input LOW Voltage 3190 3525 3190 3525 3190 3525 mV VCCT = 5.0V VOH Output HIGH Voltage 3975 4120 3975 4120 3975 4120 mV VCCT = 5.0V VOL Output LOW Voltage 3190 3380 3190 3380 3190 3380 mV VCCT = 5.0V VBB Output Bias Voltage 3620 3740 3620 3740 3620 3740 mV VCCT = 5.0V Note: 1. PECL VIL, VIH, VOL, VOH, VBB are given for VCCT = VCCE = 5.0V and will vary 1:1 with power supply. AC ELECTRICAL CHARACTERISTICS VCCT = VCCE = 5.0V ±5% TA= 0°C Symbol Parameter Min. Typ. TA= +25°C Max. Min. Typ. TA= + 85°C Max. Min. Typ. Max. Unit tPD Propagation Delay TCLK+ + 0.800 — 2.800 0.800 — 2.800 0.800 — 2.800 ns tPD Propagation Delay TCLK+ – 0.800 — 2.800 0.800 — 2.800 0.800 — 2.800 ns tPD Propagation Delay CLK+ + 0.800 — 2.800 0.800 — 2.800 0.800 — 2.800 ns tPD Propagation Delay CLK+ – 0.800 — 2.800 0.800 — 2.800 0.800 — 2.800 ns tPD Propagation Delay MR+ – 0.800 — 2.800 0.800 — 2.800 0.800 — 2.800 ns tS Set-up Time 1.5 0.5 — 1.5 0.5 — 1.5 0.5 — ns tH Hold Time1.5 0.5 — 1.5 0.5 — 1.5 0.5 — ns tPW Minimum Pulse Width CLK 1.5 — — 1.5 1.0 — 1.5 — — ns tPW Minimum Pulse Width MR 1.5 — — 1.5 — — 1.5 — — ns tr tf Rise/Fall Time — — 2.0 — 1.0 2.0 — — 2.0 ns tRES/REC Reset/Recovery Time 2.5 2.0 — 2.5 2.0 — 2.5 2.0 — ns M9999-032906 [email protected] or (408) 955-1690 4 Condition SY10H606 SY100H606 Micrel, Inc. 28-PIN PLCC (J28-1) Rev. 03 MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 TEL + 1 (408) 944-0800 FAX + 1 (408) 474-1000 WEB USA http://www.micrel.com The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer. Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify Micrel for any damages resulting from such use or sale. © 2006 Micrel, Incorporated. M9999-032906 [email protected] or (408) 955-1690 5