MICREL SY100S364JZ

Micrel, Inc.
16-INPUT
MULTIPLEXER
FEATURES
■
■
■
■
■
■
■
■
■
■
SY100S364
SY100S364
DESCRIPTION
The SY100S364 is a 16-input multiplexer designed for
use in high-performance ECL systems. The four Data
Select inputs (S0, S1, S2, S3) determine the bit from the 16
inputs (In) that will be passed on to the output as shown in
the Truth Table. The output data polarity is the same as the
input. The inputs on the device have 75KΩ pull-down
resistors.
Max. propagation delay of 1300ps
IEE min. of –63mA
Industry standard 100K ECL levels
Extended supply voltage option:
VEE = –4.2V to –5.5V
Voltage and temperature compensation for improved
noise immunity
Internal 75KΩ input pull-down resistors
70% faster than Fairchild
40% lower power than Fairchild
Function and pinout compatible with Fairchild F100K
Available in 24-pin CERPACK and 28-pin PLCC
packages
BLOCK DIAGRAM
I15
I14
I13
I12
I11
I10
I9
I8
S3
Z
I7
I6
S2
I5
I4
S1
I3
I2
S0
I1
I0
M9999-032406
[email protected] or (408) 955-1690
Rev.: H
1
Amendment: /0
Issue Date: March 2006
SY100S364
Micrel, Inc.
I10
I9
Ordering Information
I11
I13
I12
VEES
I14
PACKAGE/ORDERING INFORMATION
11 10 9 8 7 6 5
I15
S0
12
13
VEE
VEES
S1
14
15
16
S2
S3
4
3
I8
Z
VCCA
2
1
28
Top View
PLCC
J28-1
17
18
VCC
VCC
27
26
I7
I13
I12
15
14
I11
I10
Top View
Flatpack
F24-1
SY100S364FC
Sn-Pb
Commercial
SY100S364FC
Sn-Pb
SY100S364JC
J28-1
Commercial
SY100S364JC
Sn-Pb
J28-1
Commercial
SY100S364JC
Sn-Pb
J28-1
Commercial
SY100S364JZ with
Pb-Free bar-line indicator
Matte-Sn
J28-1
Commercial
SY100S364JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100S364JCTR
SY100S364JZ
(1)
(2)
I9
Z
I8
13
7 8 9 10 11 12
VCC
VCCA
Commercial
F24-1
I15
S0
17
16
I7
F24-1
SY100S364FCTR(1)
I3
I4
I5
VEES
I0
I1
I2
S2
S1
VEE
S3
I14
2
3
6
SY100S364FC
1. Tape and Reel.
2. Pb-Free package is recommended for new designs.
24 23 22 21 20 19
18
I6
I5
Lead
Finish
Notes:
1
4
5
Package
Marking
SY100S364JZTR(1, 2)
28-Pin PLCC (J28-1)
I2
I3
I4
Operating
Range
I6
19 20 21 22 23 24 25
I0
I1
Package
Type
Part Number
24-Pin Cerpack (F24-1)
M9999-032406
[email protected] or (408) 955-1690
2
SY100S364
Micrel, Inc.
TRUTH TABLE(1)
PIN NAMES
Pin
Select Inputs
Function
Output
I0 – I15
Data Inputs
S0
S1
S2
S3
Z
S0 – S3
Select Inputs
Z
Data Output
VEES
VEE Substrate
L
H
L
H
L
L
H
H
L
L
L
L
L
L
L
L
I0
I1
I2
I3
VCCA
VCCO for ECL Outputs
L
H
L
H
L
L
H
H
H
H
H
H
L
L
L
L
I4
I5
I6
I7
L
H
L
H
L
L
H
H
L
L
L
L
H
H
H
H
I8
I9
I10
I11
L
H
L
H
L
L
H
H
H
H
H
H
H
H
H
H
I12
I13
I14
I15
NOTE:
1. H = HIGH Voltage Level
L = LOW Voltage Level
DC ELECTRICAL CHARACTERISTICS
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
Symbol
IIH
IEE
Parameter
Input HIGH Current
In
S0, S1
S2, S3
Power Supply Current
Min.
Typ.
Max.
—
—
—
—
—
—
200
200
200
–63
–45
–30
Unit
Condition
µA
VIN = VIH (Max.)
mA
Inputs Open
AC ELECTRICAL CHARACTERISTICS
CERPACK
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
TA = 0°C
Symbol
Parameter
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Max.
Unit
tPLH
tPHL
Propagation Delay
I0 – I15 to Output
400
1400
400
1400
400
1400
ps
tPLH
tPHL
Propagation Delay
S0, S1 to Output
400
1900
400
1900
400
1900
ps
tPLH
tPHL
Propagation Delay
S2, S3 to Output
400
1700
400
1700
400
1700
ps
tTLH
tTHL
Transition Time
20% to 80%, 80% to 20%
300
900
300
900
300
900
ps
M9999-032406
[email protected] or (408) 955-1690
3
Condition
SY100S364
Micrel, Inc.
AC ELECTRICAL CHARACTERISTICS
PLCC
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
TA = 0°C
Symbol
Parameter
TA = +25°C
TA = +85°C
Min.
Max.
Min.
Max.
Min.
Max.
Unit
tPLH
tPHL
Propagation Delay
I0 – I15 to Output
400
1300
400
1300
400
1300
ps
tPLH
tPHL
Propagation Delay
S0, S1 to Output
400
1800
400
1800
400
1800
ps
tPLH
tPHL
Propagation Delay
S2, S3 to Output
400
1600
400
1600
400
1600
ps
tTLH
tTHL
Transition Time
20% to 80%, 80% to 20%
300
900
300
900
300
900
ps
TIMING DIAGRAM
0.7 ± 0.1 ns
0.7 ± 0.1 ns
INPUT
–0.95V
80%
50%
20%
–1.69V
tPHL
tPLH
80%
50%
20%
OUTPUT
tTLH
tTHL
Propagation Delay and Transition Times
Note:
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
M9999-032406
[email protected] or (408) 955-1690
4
Condition
SY100S364
Micrel, Inc.
24-PIN CERPACK (F24-1)
Rev. 03
M9999-032406
[email protected] or (408) 955-1690
5
SY100S364
Micrel, Inc.
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-032406
[email protected] or (408) 955-1690
6