TOSHIBA CRH01

CRH01
TOSHIBA High Efficiency Rectifier Silicon Epitaxial Type
CRH01
Switching Mode Power Supply Applications
•
Unit: mm
Repetitive peak reverse voltage: VRRM = 200 V
•
Average forward current: IF (AV) = 1.0 A
•
Low forward voltage: VFM = 0.98 V (Max.)
•
Very Fast Reverse-Recovery Time: trr = 35 ns (Max.)
•
Suitable for compact assembly due to small surface-mount package
“S−FLATTM” (Toshiba package name)
Absolute Maximum Ratings (Ta = 25°C)
Characteristics
Symbol
Rating
Unit
Repetitive peak reverse voltage
VRRM
200
V
Average forward current
IF(AV)
1.0
A
Peak one cycle surge forward current
(non-repetitive)
IFSM
15 (50 Hz)
A
Tj
−40~150
°C
JEDEC
―
Tstg
−40~150
°C
JEITA
―
Junction temperature
Storage temperature range
TOSHIBA
3-2A1A
Note: Using continuously under heavy loads (e.g. the application of high
temperature/current/voltage and the significant change in
Weight: 0.013 g (typ.)
temperature, etc.) may cause this product to decrease in the
reliability significantly even if the operating conditions (i.e. operating temperature/current/voltage, etc.) are
within the absolute maximum ratings.
Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook
(“Handling Precautions”/Derating Concept and Methods) and individual reliability data (i.e. reliability test report
and estimated failure rate, etc).
Electrical Characteristics (Ta = 25°C)
Characteristics
Peak forward voltage
Repetitive peak reverse current
Symbol
Test Condition
Min
Typ.
Max
Unit
VFM (1)
IFM = 0.1 A
⎯
0.71
⎯
VFM (2)
IFM = 0.7 A
⎯
0.86
⎯
VFM (3)
IFM = 1.0 A
⎯
0.90
0.98
VRRM = 200 V
⎯
⎯
10
μA
IRRM
V
Reverse recovery time
trr
IF = 1 A, di/dt = −30 A/μs
⎯
⎯
35
ns
Forward recovery time
tfr
IF = 1 A
⎯
⎯
100
ns
Device mounted on a ceramic board
(soldering land: 2 mm × 2 mm)
⎯
Device mounted on a glass-epoxy board
(soldering land: 6 mm × 6 mm)
⎯
Thermal resistance
Rth (j-a)
1
⎯
⎯
65
°C/W
130
2006-11-08
CRH01
Marking
Abbreviation Code
Part No.
H1
CRH01
Standard Soldering Pad
Unit: mm
1.2
1.2
2.8
Handling Precaution
The absolute maximum ratings denote the absolute maximum ratings, which are rated values and must not be
exceeded during operation, even for an instant. The following are the general derating methods that we recommend
when you design a circuit with a device.
VRRM:
We recommend that the worst case voltage, including surge voltage, be no greater than 80% of the
absolute maximum rating of VRRM for a DC circuit and be no greater than 50% of that of VRRM for
an AC circuit. VRRM has a temperature coefficient of 0.1%/°C. Take this temperature coefficient into
account designing a device at low temperature.
IF(AV):
We recommend that the worst case current be no greater than 80% of the absolute maximum rating
of IF(AV). Carry out adequate heat design. If you can’t design a circuit with excellent heat radiation,
set the margin by using an allowable Tamax-IF(AV) curve.
This rating specifies the non-repetitive peak current in one cycle of a 50-Hz sine wave, condition angle 180.
Therefore, this is only applied for an abnormal operation, which seldom occurs during the lifespan of the device.
We recommend that a device be used at a Tj of below 120°C under the worst load and heat radiation conditions.
Thermal resistance between junction and ambient fluctuates depending on the device’s mounting condition. When
using a device, design a circuit board and a soldering land size to match the appropriate thermal resistance value.
Please refer to the Rectifiers databook for further information.
2
2006-11-08
CRH01
iF – vF
PF (AV) – IF (AV)
1.0
Average forward power dissipation
PF (AV) (W)
Instantaneous forward current
iF (A)
10
150°C
75°C
Tj = 25°C
1
0.1
0.4
0.6
0.8
1.0
1.2
1.4
Instantaneous forward voltage VF
0.8
0°
180°
0.6
360°
0.4
0.2
0
0
1.6
Rectangular
waveform
(V)
0.2
0.4
0.6
Average forward current
0.8
1.0
IF (AV)
(A)
1.2
Surge forward current
Ta max – IF (AV)
(non-repetitive)
140
IFSM (A)
20
Device mounted on a
ceramic board
120
Peak surge forward current
Maximum allowable ambient temperature
Ta max (°C)
160
100
80
Rectangular
waveform
60
40
20
0°
Device mounted on a
glass-epoxy board
180°
360°
0
0
0.2
0.4
0.6
0.8
1.0
IF (AV)
(A)
Average forward current
Ta = 25°C
f = 50 Hz
16
12
8
4
0
1
1.2
10
100
Number of cycles
Cj – VR
rth (j-a) – t
(Typ.)
50
f = 1 MHz
(pF)
(1) Device mounted on a ceramic board:
Soldering land: 2 mm × 2 mm
100
(2)
(1)
10
1
1
10
100
1000
10000
30
Ta = 25°C
Cj
(2) Device mounted on a glass-epoxy board:
1000
Soldering land: 6 mm × 6 mm
Junction capacitance
Transient thermal impedance
rth (j-a) (°C/W)
10000
10
5
3
1
1
100000
Time t (ms)
10
Reverse voltage
3
100
VR
(V)
2006-11-08
CRH01
RESTRICTIONS ON PRODUCT USE
20070701-EN
• The information contained herein is subject to change without notice.
• TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc.
• The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.).These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in his
document shall be made at the customer’s own risk.
• The products described in this document shall not be used or embedded to any downstream products of which
manufacture, use and/or sale are prohibited under any applicable laws and regulations.
• The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which
may result from its use. No license is granted by implication or otherwise under any patents or other rights of
TOSHIBA or the third parties.
• Please contact your sales representative for product-by-product details in this document regarding RoHS
compatibility. Please use these products in this document in compliance with all applicable laws and regulations
that regulate the inclusion or use of controlled substances. Toshiba assumes no liability for damage or losses
occurring as a result of noncompliance with applicable laws and regulations.
4
2006-11-08