COILCRAFT 0603PS

Document 266-1
Shielded High SRF Inductors – 0603PS
• Higher SRF than our other power inductors
• High inductance with tight tolerance
• Excellent current handling for a part this size
Core material Ceramic/Ferrite
Core and winding loss See www.coilcraft.com/coreloss
Terminations RoHS compliant silver-palladium-platinum-glass frit.
Weight 26.4 – 27.9 mg
Ambient temperature –40°C to +65°C with Irms current, +65°C to
+105°C with derated current
Storage temperature Component: –40°C to +105°C.
Tape and reel packaging: –40°C to +80°C
Resistance to soldering heat Max three 40 second reflows at
+260°C, parts cooled to room temperature between cycles
Moisture Sensitivity Level (MSL) 1 (unlimited floor life at <30°C /
85% relative humidity)
Failures in Time (FIT) / Mean Time Between Failures (MTBF)
38 per billion hours / 26,315,789 hours, calculated per Telcordia SR-332
Packaging 2000/7″reel; 7500/13″ reel Plastic tape: 8 mm wide,
0.23 mm thick, 4 mm pocket spacing, 1.8 mm pocket depth
PCB washing Tested with pure water or alcohol only. For other solvents,
see Doc787_PCB_Washing.pdf.
DCR4 SRF5
Part L ±10%2 Q min3
max
typ Isat6 Irms7
number1
(µH) at 1 MHz (Ohms) (MHz) (A)
(A)
0603PS-781KL_ 0.78 15
0.24 475 0.551.30
0603PS-102KL_ 1.0
15
0.26 390 0.401.00
0603PS-182KL_ 1.8
15
0.54 155 0.390.70
0603PS-222KL_ 2.2
15
0.75 245 0.330.60
0603PS-272KL_ 2.7
15
0.75 127 0.330.55
0603PS-332KL_ 3.3
15
0.88 72 0.320.50
0603PS-392KL_ 3.9
15
1.00 72 0.270.48
0603PS-472KL_ 4.7
15
1.08 64 0.260.47
0603PS-562KL_ 5.6
15
1.23 51 0.250.41
0603PS-682KL_ 6.8
15
1.37 39 0.230.40
0603PS-822KL_ 8.2
20
1.43 30 0.220.39
0603PS-103KL_10
20
1.60 30 0.210.38
0603PS-153KL_15
20
1.92 22 0.160.35
0603PS-223KL_22
20
2.96 16 0.130.27
0603PS-333KL_33
20
5.63 12 0.100.20
0603PS-473KL_47
20
5.69 12 0.100.18
1. When ordering, please specify packaging code:
0603PS-473KLC
Packaging:C
=7″ machine-ready reel. EIA-481 embossed plastic
tape (2000 parts per full reel).
B=Less than full reel. In tape, but not machine ready.
To have a leader and trailer added ($25 charge),
use code letter C instead.
D
=13″ machine-ready reel. EIA-481 embossed plastic
tape (7500 parts per full reel).
2. Inductance measured at 100 kHz, 0.1 Vrms, using a Coilcraft SMD-A
fixture in an Agilent/HP 4263B LCR meter.
3. Q measured on an Agilent/HP 4291 with an Agilent/HP 16193 test
fixture.
4. DCR measured on a micro-ohmmeter and a Coilcraft CCF840 test
fixture.
5. SRF measured using an Agilent/HP 8753D network analyzer and a
Coilcraft SMD-D test fixture.
6. DC current at which the inductance drops 10% (typ) from its value
without current.
7. Current that causes a 40°C temperature rise from 25°C ambient.
8. Electrical specifications at 25°C.
Refer to Doc 362 “Soldering Surface Mount Components” before soldering.
US +1-847-639-6400 [email protected]
UK +44-1236-730595 [email protected]
Taiwan +886-2-2264 3646 [email protected]
China +86-21-6218 8074 [email protected]
Singapore + 65-6484 8412 [email protected]
Document 266-1 Revised 03/14/12
© Coilcraft Inc. 2013
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.
Please check web site for latest information.
Document 266-2
Power Chip Inductors - 0603PS Series
Typical L vs Frequency
Typical L vs Current
100
100
Inductance (µH)
1000
Inductance (µH)
1000
33 µH
10
6.8 µH
3.3 µH
1 µH
1
0.1
0.1
33 µH
10
6.8 µH
3.3 µH
1 µH
1
10
1
0.1
100
1
100
10
Typical Q vs Frequency
C
B
overall
35
D
30
Q factor
H
I
25
33 µH
F
A
6.8 µH
J
I
G
20
10 µH
1 µH
3.3 µH
15
E
terminal
10
Terminal wraparound:
approx 0.012/0,30 both ends
Recommended
Land
Pattern
ABC
maxmaxmax D E F G H IJ
0.1020.0820.0710.0490.0300.0600.0130.0400.0250.025 inches
2,592,081,801,240,761,520,331,020,640,64mm
5
0
1000
Current (mA)
Frequency (MHz)
1
0.1
10
Frequency (MHz)
Irms Derating
120
110
90
80
70
60
50
40
30
25°C
Percent of rated Irms
100
20
10
0
-40
-20
0
20
40
60
80
100
120
Ambient temperature (°C)
US +1-847-639-6400 [email protected]
UK +44-1236-730595 [email protected]
Taiwan +886-2-2264 3646 [email protected]
China +86-21-6218 8074 [email protected]
Singapore + 65-6484 8412 [email protected]
Document 266-2 Revised 03/14/12
© Coilcraft Inc. 2013
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.
Please check web site for latest information.