COILCRAFT ST466PJD

5030 COUPLED INDUCTORS
Coupled Inductors for Critical Applications
The ST466PJD coupled miniature shielded inductors are
only 3 mm high and 5 mm square. They are ideal for use
in a variety of circuits including flyback, multi-output buck
and SEPIC.
These inductors provide high inductance, high efficiency
and excellent current handling in a rugged, low cost part.
They can also be used as two single inductors connected
in series or parallel or as a common mode choke.
+
+
D
L1
VIN
C
L2
C
VOUT
–
SW
–
Typical Flyback Converter
L2
D
+
C
VOUT
AUX
–
0.189 ±0.003
4,80 ±0,076
+
Dot indicates pin 1
1
VIN
4
Dash
number
D
L1
Internal
code
VIN
Suggested
Land Pattern
–
0.138
3,50
0.090
2,30
45°
typ
0.134 0.090
3,40 2,30
0.060
1,52
2
0.030
0,75
0.197
5,00
0.059
1,50
0.134
3,40
0.197
5,00
4
L2
Dimensions are in
3
VOUT
inches
mm
+
C1
L2
Q
C
Typical SEPIC schematic
VOUT
–
Core material Ferrite
Core and winding loss See http://www.coilcraft-cps.com/coupledloss
Weight 210 – 225 mg
Terminations RoHS compliant, halogen free silver-palladium-platinum-glass frit. Other terminations available at additional cost.
Ambient temperature –40°C to +85°C with Irms current, +85°C to
+125°C with derated current
Storage temperature Component: –55°C to +125°C.
Packaging: –55°C to +80°C
Winding to winding isolation 100 V
Resistance to soldering heat Max three 40 second reflows at
+260°C, parts cooled to room temperature between cycles
Moisture Sensitivity Level (MSL) 1 (unlimited floor life at <30°C /
85% relative humidity)
Packaging 750 per 7″ reel Plastic tape: 12 mm wide,
0.32 mm thick, 8 mm pocket spacing, 3.1 mm pocket depth
Recommended pick and place nozzle OD: 5 mm; ID: ≤ 2.5 mm
Document ST757-1 Revised 09/06/12
®
© Coilcraft, Inc. 2012
C
–
+
0.114 ±0.004
2,90 ±0,10
L1
D
Typical Buck Converter with auxiliary output
3
1
SW
–
0.189 ±0.003
4,80 ±0,076
XXX X
2
+
L1
1102 Silver Lake Road
Cary, IL 60013
Phone 800-981-0363
Fax 847-639-1508
Email [email protected]
www.coilcraft-cps.com
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specifications subject to change without notice.
Please check our web site for latest information.
5030 COUPLED INDUCTORS
ST466PJD Series Coupled Inductors
Isat (A)6 Irms (A)
CouplingLeakage
2 3 4
5
Inductance DCR max SRF typ coefficient
L typ
10% 20%
30%
both
one
Part number1
(µH) (Ohms) (MHz)
typ
(µH) drop dropdrop windings7 winding8
ST466PJD102NLZ 1.0 ±30%
ST466PJD152MLZ 1.5 ±20%
ST466PJD222MLZ 2.2 ±20%
ST466PJD332MLZ 3.3 ±20%
ST466PJD472MLZ 4.7 ±20%
0.042
0.048
0.067
0.077
0.111
156
123
78.0
65.0
53.0
0.95
0.97
0.98
0.98
0.99
0.09
0.09
0.10
0.10
0.11
4.6
3.9
3.1
2.5
2.1
4.8
4.2
3.3
2.7
2.2
5.0
4.3
3.4
2.8
2.2
2.60
2.20
2.15
1.85
1.45
3.68
3.11
3.04
2.62
2.05
ST466PJD562MLZ 5.6 ±20%
ST466PJD682MLZ 6.8 ±20%
ST466PJD103MLZ 10 ±20%
ST466PJD153MLZ 15 ±20%
ST466PJD223MLZ 22 ±20%
0.125
0.159
0.210
0.298
0.452
48.0
43.0
31.0
25.0
19.0
0.99
0.99
0.99
0.99
1.0
0.11
0.12
0.13
0.15
0.17
2.0
1.8
1.3
1.2
1.0
2.0
1.9
1.3
1.4
1.1
2.1
1.9
1.3
1.4
1.1
1.35
1.20
1.05
0.85
0.70
1.91
1.70
1.48
1.20
0.99
ST466PJD333MLZ 33 ±20%
0.565
15.0
ST466PJD473MLZ 47 ±20%
0.806
12.6
ST466PJD683MLZ 68 ±20%
1.13
10.0
ST466PJD104MLZ 100 ±20% 1.79
8.32
ST466PJD154MLZ 150 ±20% 2.43
6.80
1.0
1.0
1.0
1.0
1.0
0.20
0.80
0.84
0.85
0.24
0.65
0.69
0.72
0.29
0.50
0.54
0.55
0.370.470.540.56
0.460.380.430.45
0.60
0.50
0.46
0.35
0.31
0.85
0.71
0.64
0.49
0.43
ST466PJD224MLZ 220 ±20% 3.30
ST466PJD334MLZ 330 ±20% 5.36
ST466PJD474MLZ 470 ±20% 7.51
ST466PJD684MLZ 680 ±20%10.8
ST466PJD105MLZ
1000 ±20%16.5
1.0
1.0
1.0
1.0
1.0
0.540.310.350.36
0.650.250.250.32
0.760.210.240.26
0.890.170.200.21
1.200.150.170.17
0.26
0.20
0.17
0.14
0.11
0.37
0.28
0.23
0.19
0.15
5.55
4.05
3.34
2.78
2.24
1. When ordering, please specify termination and testing code:
Temperature rise calculation based on specified Irms
ST466PJD105MLZ
Termination:L=RoHS compliant silver-palladium-platinum-glass frit.
Special order: T = RoHS tin-silver-copper (95.5/4/0.5)
or S = non-RoHS tin-lead (63/37).
Testing:Z =COTS
H=Screening per Coilcraft CPSA-10001
2. Inductance shown for each winding, measured at 100 kHz, 0.1 Vrms,
0 Adc on an Agilent/HP 4284A LCR meter or equivalent. When leads
are connected in parallel, inductance is the same value. When leads are
connected in series, inductance is four times the value.
3. DCR is for each winding. When leads are connected in parallel, DCR
is half the value. When leads are connected in series, DCR is twice the
value.
4. SRF measured using an Agilent/HP 4191A or equivalent. When leads
are connected in parallel, SRF is the same value.
5. Leakage Inductance is for L1 and is measured with L2 shorted.
6. DC current, at which the inductance drops the specified amount from its
value without current. It is the sum of the current flowing in both windings.
7. Equal current when applied to each winding simultaneously that causes
a 40°C temperature rise from 25°C ambient. See temperature rise
calculation.
8. Maximum current when applied to one winding that causes a 40°C
temperature rise from 25°C ambient. See temperature rise calculation.
9. Electrical specifications at 25°C.
Winding power loss = (IL12 + IL22 ) × DCR in Watts (W)
90°C
Temperature rise = Winding power loss ×
W
Examples for ST466PJB472ML:
Equal current in each winding (1.4 A):
Winding power loss = (1.4 2 + 1.4 2) × 0.111 = 0.435 W
Temperature rise = 0.435 W × 90°C = 39.2°C
W
Unequal current (IL1 = 1.8 A, IL2 = 0.8 A):
Winding power loss = (1.8 2 + 0.8 2) × 0.111 = 0.431 W
90°C = 38.8°C
Temperature rise = 0.431 W ×
W
Document ST757-2 Revised 09/06/12
®
© Coilcraft, Inc. 2012
1102 Silver Lake Road
Cary, IL 60013
Phone 800-981-0363
Fax 847-639-1508
Email [email protected]
www.coilcraft-cps.com
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specifications subject to change without notice.
Please check our web site for latest information.
5030 COUPLED INDUCTORS
ST466PJD Series Coupled Inductors
Typical L vs Current
Typical L vs Frequency
10000
10000
330 µH
100
1000 µH
1000
1000 µH
Inductance (µH)
Inductance (µH)
1000
100 µH
33 µH
10
330 µH
100 µH
100
33 µH
10 µH
10
10 µH
3.3 µH
3.3 µH
1
0.01
1
0.1
10
1
0.1
Current (A)
1
10
100
Frequency (MHz)
Typical Current Derating
100
90
80
70
60
50
40
30
20
10
0
25°C
Percent of rated current
120
110
Isat
Irms
-55 -40
-20
0
20
40
60
80
100
120 140
Ambient temperature (°C)
Document ST757-3 Revised 09/06/12
®
© Coilcraft, Inc. 2012
1102 Silver Lake Road
Cary, IL 60013
Phone 800-981-0363
Fax 847-639-1508
Email [email protected]
www.coilcraft-cps.com
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specifications subject to change without notice.
Please check our web site for latest information.