Basic Switches Standard Basic Switches Sealed/High Temperature Switches Miniature/Subminiature Switches Selection Door Switches SUBMINIATURE/MINIATURE BASIC SWITCHES The U Series of subminiature basic switches are our newest line. The US is the smallest snap-action switch available. The UX and UM are versatile, low cost, full featured products with ample electrical capacity in a compact package. SM subminiature basic switches are a versatile collection of small size and ample electrical capacities, including 11 amp power load handling and 1⁄4 hp motor load. SX subminiature basic switches are smaller than SM switches, yet are big in performance and selection. They provide up to 7 amp power load capacity. V3 miniature basic switches put a 25 amp power load capacity and a choice of 11 other electrical ratings into a relatively small package with many choices of actuators, contact materials, and terminal designs. V7 miniature basic switches have electrical ratings up to 15 amps. Both commercial and European versions are UL recognized and CSA certified. The latter is also designed to meet all leading European approval agency requirements. TB miniature basic small double-break units can control 2, 3 or 4 isolated circuits. Typical Applications . . . . . . . . . . . . . . . . . . . . . . . p. 2 Index by Product Type . . . . . . . . . . . . . . . . . . . . . p. 3 Selection Guides. . . . . . . . . . . . . . . . . . . . . . p. 4 to 7 Catalog Listings/Order Guides . . . . . . . . . p. 8 to 93 Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . p. 94 Catalog Listing/Page Number Index . . . . . . . p. 102 STANDARD BASIC SWITCHES Power load switching and motor handling capacity are among the attractions of thumb-size BZ/BA standard basic switches. Double-pole double-throw switching is added by DT switches. Where there’s a need for reliable switching of high capacity systems involving DC motors and solenoids, MT magnetic blow-out switches do the job. The 3MN has double-break switching. 6AS assemblies have two tandem mounted standard basic switches under a common actuator. SEALED AND HIGH TEMPERATURE BASIC SWITCHES Specially adapted basic switches include: SE/XE environment-proof switches which protect subminiature SM/SX basic switches within a sealed housing; HM hermetically sealed switches are interchangeable in operating point with the SM switches; HS hermetically sealed switches which parallel the size and mounting scheme of the standard basic switches; and HT high temperature switches for use up to +1000°F. DOOR SWITCHES AC, WW and DM switches automatically cut power when a service door or drawer is opened. For application help: call 1-800-537-6945. Honeywell Sensing and Control 1 Basic Switches Subminiature/Miniature ELECTRICAL DATA AND UL CODES MINIATURE/SUBMINIATURE BASIC SWITCHES Most of the switches in this section are UL recognized and CSA certified. The current and voltage values shown are based on test conditions specified by these agencies. Electrical life of the switch is influenced by each application condition as well as by voltage and current. Circuitry Circuitry S UL rating: 4 amps, 250 vac. Single-pole double-throw T UL/CSA rating: 11 amps and 1/3 hp, 125, 250, or 277 vac; 1/2 amp, 125 vdc; 1/4 amp, 250 vdc; 4 amps, 125 vac ‘‘L’’ (lamp load). Electrical Data Single-pole double-throw A 5 amps res., 3 amps ind., (sea level), 4 amps res., 2 amps ind., (50,000 feet), 28 vdc 5 amps res. or ind. 115 vac, 60 Hz. UL/CSA rating: 5 amps, 250 vac. Single-pole double-throw B 7 amps res., 4 amps ind., (sea level), 7 amps res., 2.5 amps ind., (50,000 feet), 28 vdc. UL/CSA rating: 7 amps, 250 vac. Single-pole double-throw C 3.5 amps res., 2 amps ind., (sea level), 3.5 amps res., 1.5 amps ind., (50,000 feet), 28 vdc. UL rating: 7 amps, 250 vac. Single-pole double-throw Electrical Data Single-pole double-throw TT UL/CSA rating: 10 amps and 1/3 hp, 125 or 250 vac; 1/2 amp, 125 vdc; 1/4 amp, 250 vdc; 4 amps, 125 vac ‘‘L’’ (lamp load). Single-pole double-throw unless otherwise noted in order guide UU 10 amps res., 10 amps ind., (sea level), 6 amps ind. (50,000 feet), 6 amps motor load, 30 vdc. D 1 amp res., 0.5 amp ind., (sea level and 50,000 feet), 28 vdc. UL/CSA rating: 1 amp, 125 vac. Single-pole double-throw VV UL/CSA rating: 3 amps-125, 250, 277 vac; 1/10 hp-250 vac Single-pole double-throw E 3 amps res., 2 amps ind., (sea level), 28 vdc. UL rating: 3 amps, 250 vac. Single-pole double-throw Single-pole double-throw F 7 amps res., 4 amps ind., 2.5 amps lamp load, (sea level), 4 amps res., 2.5 amps ind., 2.5 amps lamp load, (50,000 feet), 28 vdc. 7 amps res., 7 amps ind., 2 amps lamp load, 115 vac, 60 Hz (sea level). V UL/CSA rating: 10 amps and 1/4 hp, 125 or 250 vac; 1/2 amp, 125 vdc; 1/4 amp, 250 vdc; 3 amps, 125 vac ‘‘L’’ (lamp load). Single-pole double-throw W 10 amps, 250 vac or 28 vdc; 1/2 amp, 125 vdc; 1/4 amp, 250 vdc. Single-pole double-throw X UL rating: 1 amp, 125 vac. Y 10 amps and 1/3 hp, 125 or 250 vac; 4 amps, 125 vac ‘‘L’’ (lamp load). Single-pole double-throw G 2 amps res., lamp ind., (sea level) 28 vdc. Single-pole double-throw Single-pole double-throw H .010 amp res. and ind., (sea level). 28 vdc. UL/CSA rating: 1 amp, 125 vac. Single-pole double-throw Single-pole double-throw I 7 amps res., 4 amps ind., (sea level), 28 vdc. Two-circuit double-break Single-pole double-throw J 5 amps res., 3 amps ind., (sea level), 5 amps res., 2.5 amps ind., (50,000 feet), 28 vdc. UL rating: 5 amps, 250 vac. Four-circuit double-break Single-pole double-throw K UL rating: 5 amps, 125 or 250 vac. Single-pole double-throw L 1 amp res., 1/2 amp ind., (sea level) 28 vdc. Single-pole double-throw M UL rating: 11 amps and 1/4 hp, 125 or 250 vac. Single-pole double-throw N 1 amp res., 0.5 amp ind., 30 vdc. UL rating: 1 amp, 125 vac. Single-pole double-throw P 1 amp res., 30 vdc. UL rating: .1 amp, 125 vac. Single-pole double-throw R 5 amps res., 3 amps ind., 2.4 amps lamp load (sea level), 5 amps res., 2.5 amps ind., 2.4 amps lamp load, (50,000 feet), 28 vdc. 5 amps res., 5 amps ind., 1.5 amps lamp load, 115 vac. 60 Hz (sea level) 20 Honeywell Sensing and Control U UL/CSA rating: 15.1 amps and 1/2 hp, 125 or 250 vac. 1/2 amp, 125 vdc; 1/4 amp, 250 vdc; 5 amps, 120 vac ‘‘L’’ (lamp load). YY UL/CSA rating: 5 amps-125, 250, 277 vac 1/10 hp-250 vac Z 10 amps, 125 or 250 vac, or 30 vdc. UL/CSA rating: 10 amps, 125 or 250 vac; 1/2 hp, 125 vac. Single-pole double-throw ZZ UL rating: 5 amps and 1/10 hp. 125 or 250 vac. Single-pole double-throw AA UL rating: 20 amps, 277 vac. 1 hp, 125 vac; 2 hp, 250 vac. Single-pole double-throw BB UL rating: 25 amps, 277 vac. 1 hp, 125 vac; 2 hp, 250 vac. For application help: call 1-800-537-6945. Basic Switches Standard ELECTRICAL DATA AND UL CODES STANDARD BASIC SWITCHES Most of the switches in this section are UL recognized and CSA certified. The current and voltage values shown are based on test conditions specified by these agencies. Electrical life of the switch is influenced by each application condition as well as by voltage and current. For application assistance contact the 800 number. Circuitry Double-pole double-throw J 10 amps, 125 or 250 vac; 0.3 amp, 125 vdc; 0.15 amp, 250 vdc. UL Code L59 Single-pole double-throw unless otherwise noted in order guide K Rating established with switch non-polarized 10 amps, 125 vac or vdc; 1 ⁄4 hp, 125 vac or vdc. UL Code L 168 Non-polarized: 10 amps res. or 1⁄4 hp, 125 vdc; 3 amps max. res. 250 vdc. Polarized*: 10 amps res. or 1⁄2 hp, 125 vdc; 3 amps max. res., 250 vdc. Electrical Data and UL Codes Circuitry Electrical Data and UL Codes Single-pole double-throw unless otherwise noted in order guide A 15 amps, 125, 250 or 480 vac; 1 ⁄8 hp, 125 vac; 1⁄4 hp, 250 vac; 1 ⁄2 amp, 125 vdc; 1⁄4 amp, 250 vdc. UL Code L96 Single-pole double-throw unless otherwise noted in order guide B 5 amps, 125, 250 or 480 vac; 1 ⁄2 amp, 125 vdc; 1⁄4 amp, 250 vdc. UL Code L35 Single-pole double-throw unless otherwise noted in order guide C 10 amps, 125, 250 or 480 vac; UL Code L8 Single-pole double-throw R 10 amps, 125 or 250 vac; 1 ⁄3 hp, 125 vac; 3⁄4 hp, 250 vac; 1 ⁄2 amp, 125 vdc; 1⁄4 amp, 250 vdc. UL Code L115 Single-pole double-throw unless otherwise noted in order guide D 15 amps, 125, 250 or 480 vac; 1 ⁄8 hp, 125 vac; 1⁄4 hp, 250 vac. UL Code L103 Single-pole double-throw S 10 amps, 125 or 250 vac; 1 ⁄3 hp, 125 or 250 vac. UL Code L93 Single-pole double-throw unless otherwise noted in order guide E 15 amps, 125, 250 or 480 vac; 1 ⁄4 hp, 125 vac, 1⁄2 hp, 250 vac; 1 ⁄2 amp, 125 vdc; 1⁄4 amp, 250 vdc. UL Code L67 Single-pole double-throw unless otherwise noted in order guide F 22 amps, 125, 250 or 480 vac; 1 ⁄2 hp, 125 vac, 1 hp, 250 vac. UL Code L161 Single-pole double-throw unless otherwise noted in order guide G 20 amps, 125, 250 or 480 vac; 10 amps, 125 vac ‘‘L’’ (tungsten lamp load); 1 hp, 125 vac; 2 hp, 250 vac; 1 ⁄2 amp, 125 vdc; 1⁄4 amp, 250 vdc. UL Code L23 Single-pole double-throw unless otherwise noted in order guide H Motor Control 25 amps, 125, 250 or 480 vac; 1 hp, 125 vac; 2 hp, 250 vac; Pilot Duty—750 VA, 125, 250, or 277 vac. Single-pole double-throw unless otherwise noted in order guide I 46 10 amps, 125, 250 or 480 vac; 1 ⁄8 hp, 125 vac; 1⁄4 hp, 250 vac; UL Code L95 Honeywell Sensing and Control *To polarize, connect negative side of line to common terminal. To achieve the same effect, mount switch with brass screws, using a non-magnetic barrier (at least 1⁄4 N thick) between the switch and mounting surface. Two-circuit double-break Single-pole double-throw Two-circuit double-break Single-pole double-throw Two-circuit double-break Single-pole single-throw (N.C.) Single-pole double-throw Single-pole double-throw M 25 amps, 125, 250 or 480 vac; 3 ⁄4 hp, 125 vac; 11⁄4 amp, 250 vac. 1 amp, 125 vdc; 1⁄2 amp, 250 vdc. UL Code L58 P 1 amp, 125 VAC UL Code L22 T 15 amps, 125, 250 or 480 vac; 1 amp, 125 vdc; 1⁄2 amp, 250 vdc; 1 ⁄4 hp, 125 vac; 1⁄2 hp, 250 vac UL Code L73 U 5 amps, 250 vac. UL Code L4 V Motor Control 15 amps, 120, 240, 480 or 600 vac; 1 ⁄2 hp, 120 vac; 1 hp, 240 vac; 0.8 amp, 115 vdc; 0.4 amp, 230 vdc. W 20 amps, 125, 250 or 277 vac; 3 ⁄4 hp, 125 vac; 1⁄2 hp, 250 vac UL Code L178B X 15 amps, 125, 250 or 480 vac; 2 amps, 600 vac; 1 ⁄8 hp, 125 vac; 1⁄4 hp, 250 vac; 1 ⁄2 amp, 125 vdc; 1⁄4 amp, 250 vdc. UL Code L74 Y 20 amps, 125, 250 or 480 vac; 3 ⁄4 hp, 125 vac; 11⁄2 hp, 250 vac; UL Code L17 For application help: call 1-800-537-6945. Basic Switches Operating Characteristics ELECTROMECHANICAL SWITCHES Definitions below explain the meaning of operating characteristics. Characteristics shown in tables throughout catalog were chosen as most significant. They are taken at normal room temperature and humidity. These may vary as temperature and humidity conditions differ. Sketches show how characteristics are measured for in-line plunger actuation. Linear dimensions for in-line actuation are from top of plunger to a reference line, usually the center of the mounting holes. Differential Travel (D.T.)—Plunger or actuator travel from point where contacts ‘‘snap-over’’ to point where they ‘‘snapback.’’ Free Position (F.P.)—Position of switch plunger or actuator when no external force is applied (other than gravity). Full Overtravel Force—Force required to attain full overtravel of actuator. Operating Position (O.P.)—Position of switch plunger or actuator at which point contacts snap from normal to operated position. Note that in the case of flexible or adjustable actuators, the operating position is measured from the end of the lever or its maximum length. Location of operating position measurement shown on mounting dimension drawings. Operating Force (O.F.)—Amount of force applied to switch plunger or actuator to cause contact ‘‘snap-over.’’ Note in the case of adjustable actuators, the force is measured from the maximum length position of the lever. Overtravel (O.T.)—Plunger or actuator travel safely available beyond operating position. Pretravel (P.T.)—Distance or angle traveled in moving plunger or actuator from free position to operating position. Release Force (R.F.)—Amount of force still applied to switch plunger or actuator at moment contacts snap from operated position to unoperated position. Total Travel (T.T.)—Distance from actuator free position to overtravel limit position. IN-LINE PLUNGER ACTUATION 94 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Operating Characteristics FULL LOAD AND LOCKED ROTOR CURRENTS FOR SINGLE PHASE AND DC MOTORS Alternating Current 115 Volts Direct Current 230 Volts 115 Volts HP Full Load Locked Rotor Full Load Locked Rotor Full Load Locked Rotor 2 11⁄2 1 3 ⁄4 1 ⁄2 1 ⁄3 1 ⁄4 1 ⁄6 1 ⁄8 1 ⁄10 1 ⁄20 24.0 20.0 16.0 13.8 9.8 7.2 5.8 4.4 3.8 3.0 1.5 144.0 120.0 96.0 82.8 58.8 43.2 34.8 26.4 22.8 18.0 9.0 12.0 10.0 8.0 6.9 4.9 3.6 2.9 2.2 1.9 1.5 — 72.0 60.0 48.0 41.4 29.4 21.6 17.4 13.2 11.4 9.0 — 17.0 13.2 9.6 7.4 5.4 3.8 3.0 2.4 2.2 2.0 — 170.0 132.0 96.0 74.0 54.0 38.0 30.0 24.0 22.0 20.0 — 230 Volts Full Load 8.5 6.6 4.8 3.7 2.7 1.9 1.5 1.2 1.1 1.0 — Locked Rotor 85.0 66.0 48.0 37.0 27.0 19.0 15.0 12.0 11.0 10.0 — Reference/Index For application help: call 1-800-537-6945. Honeywell Sensing and Control 95 Basic Switches B Type Switches Performance Information ELECTRICAL DATA CHART Catalog Listing (contact gap) BZ-3YT* .036 in. 0,91 mm BZ-3YT* .036 in. 0,91 mm BM-2R .020 in. 0,50 mm BM-2R .020 in. 0,50 mm BA-2R .020 in. 0,50 mm BA-2R .020 in. 0,50 mm BE-2R .020 in. 0,50 mm BE-2R .020 in. 0,50 mm BZ-R .006 in. 0,15 mm BZ-1R .010 in. 0,25 mm BZ-1R .010 in. 0,25 mm Amperes Current Inrush Carrying Capacity N.C. Resistive Ckt. Max.1 N.O. Ckt. Motor N.C. Ckt. N.O. Ckt. Lamp N.C. Ckt. N.O. Ckt. Inductive2 Sea 50,000 Level Feet VDC 8 14 30 125 250 5 5 5 5 5 10 10 10 1 0.6 30 30 30 10 6 15 15 15 10 6 5 5 5 2 1.2 2.5 2.5 2.5 2 1.2 3 3 3 1 0.6 1.5 1.5 1.5 1 0.6 10 10 10 0.6 0.4 10 10 5 0.4 0.3 VAC 120 240 277 5 5 5 5 5 5 30 30 30 15 15 15 5 5 5 2.5 2.5 2.5 3 3 3 1.5 1.5 1.5 5 5 5 5 5 5 VDC 8 14 30 125 230 22 22 22 22 22 15 15 2 0.4 0.2 30 30 30 4 2 15 15 15 4 2 5 5 5 0.8 0.4 2.5 2.5 2.5 0.4 0.2 3 3 3 0.4 0.2 1.5 1.5 1.5 0.4 0.2 8 5 1 .03 .02 7 5 1 .02 .01 VAC 125 250 277 460 22 22 22 22 22 22 22 22 35 35 35 35 20 20 20 20 5.8 5.8 5.8 5.8 3.4 3.4 3.4 3.4 3.5 3.5 3.5 3.5 2.0 2.0 2.0 2.0 22 22 22 22 22 22 22 22 VDC 8 14 30 125 230 20 20 20 20 20 20 20 5 0.5 0.25 30 30 30 4 2 15 15 15 4 2 5 5 5 0.8 0.4 2.5 2.5 2.5 0.4 0.2 3 3 3 0.4 0.2 1.5 1.5 1.5 0.4 0.2 15 10 5 .05 .03 15 8 2 .03 .02 VAC 120 240 277 460 20 20 20 20 20 20 20 20 75 75 75 75 75 75 75 75 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 20 20 20 20 20 20 20 20 VDC 8 14 30 125 250 25 25 25 25 25 25 25 5 0.5 0.25 30 30 30 4 2 15 15 15 4 2 5 5 5 0.8 0.4 2.5 2.5 2.5 0.8 0.4 3 3 3 0.4 0.2 1.5 1.5 1.5 0.4 0.2 15 10 5 .05 .03 15 8 2 .03 .02 VAC 120 240 277 460 25 25 25 25 25 25 25 25 96 96 96 96 96 96 96 96 16 16 16 16 16 16 16 16 10 10 10 10 10 10 10 10 25 25 25 25 VAC 125 250 277 15 15 15 15 15 15 30 30 30 15 15 15 5 5 5 2.5 2.5 2.5 3 3 3 1.5 1.5 1.5 15 15 15 15 15 15 VDC 8 14 30 125 230 15 15 15 15 15 15 15 2 0.4 0.2 30 30 30 4 2 15 15 15 4 2 5 5 5 0.8 0.4 2.5 2.5 2.5 0.8 0.4 3 3 3 0.4 0.2 1.5 1.5 1.5 0.4 0.2 8 5 1 0.03 0.02 7 5 1 0.01 0.01 VAC 125 250 277 460 15 15 15 15 15 15 15 15 30 30 30 30 15 15 15 15 5 5 5 5 2.5 2.5 2.5 2.5 3 3 3 3 1.5 1.5 1.5 1.5 15 15 15 15 15 15 15 15 Voltage *Ampere levels for BZ-3YT applicable only if common terminal is not used and switch is used as a shorting bar switch. 96 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches B Type Switches Performance Information ELECTRICAL DATA CHART, cont. Catalog Listing (contact gap) BZ-2R .020 in. 0.50 mm BZ-2R .020 in. 0,50 mm BZ-3R .036 in. 0,91 mm BZ-3R .036 in. 0,91 mm BZ-7R .070 in. 1,78 mm BZ-7R .070 in. 1,78 mm Amperes Current Inrush Carrying Capacity N.C. Resistive Ckt. Max.1 N.O. Ckt. Motor N.C. Ckt. N.O. Ckt. Lamp N.C. Ckt. N.O. Ckt. Inductive2 Sea 50,000 Level Feet VDC 8 14 30 125 230 15 15 15 15 15 15 15 6 0.4 0.2 30 30 30 4 2 15 15 15 4 2 5 5 5 0.8 0.4 2.5 2.5 2.5 0.8 0.4 3 3 3 0.4 0.2 1.5 1.5 1.5 0.4 0.2 15 10 5 0.05 0.03 15 8 2 0.03 0.02 VAC 125 250 277 460 15 15 15 15 15 15 15 15 30 30 30 30 15 15 15 15 5 5 5 5 2.5 2.5 2.5 2.5 3 3 3 3 1.5 1.5 1.5 1.5 15 15 15 15 15 15 15 15 VDC 8 14 30 125 250 15 15 15 15 15 15 15 10 0.6 0.3 30 30 30 6 3 15 15 15 6 3 5 5 5 1.2 0.6 2.5 2.5 2.5 1.2 0.6 3 3 3 0.6 0.3 1.5 1.5 1.5 0.6 0.3 15 15 10 0.1 0.05 15 15 5 0.05 0.03 VAC 125 250 277 460 15 15 15 15 15 15 15 15 30 30 30 30 15 15 15 15 5 5 5 4 2.5 2.5 2.5 2.5 3 3 3 3 1.5 1.5 1.5 1.5 15 15 15 15 15 15 15 15 VDC 8 14 30 125 250 30 15 15 15 15 15 15 15 0.75 0.3 15 30 30 7.5 3 5 15 15 7.5 3 2.5 5 5 1.5 0.6 3 2.5 2.5 1.5 0.6 1.5 3 3 0.75 0.3 15 1.5 1.5 0.75 0.3 15 15 10 0.4 0.2 — 15 7.5 0.2 0.1 VAC 120 240 277 460 15 15 15 15 15 15 15 15 30 30 30 30 15 15 15 15 5 5 5 5 2.5 2.5 2.5 2.5 3 3 3 3 1.5 1.5 1.5 1.5 15 15 15 15 15 15 15 15 Voltage 1 For a 86− F (30−C) max. temperature rise at terminals, not opening or closing the load (at sea level). 2 Data established with a 75% power factor on AC loads. TEST CONDITIONS Switch contact life is affected by electrical conditions and other factors, such as: temperature, humidity, airborne contamination, vibration, amount and rate of plunger travel, and cycling Temperature: Humidity: AC Cycle Rate: DC Cycle Rate: On-off Time: Power Factor (AC): Inductance (DC): Circuit Loading: Travel Plunger: Actuation: Overtravel Force: rate. Our Evaluation Laboratory tests are conducted using procedures and practices common to UL and Military Specifications. The following conditions generally apply. Room Ambient (70 −F, 21−C). Room Ambient (50%). 60 operations/minute. 20 operations/minute. Equal and compatible with above cycling rates. Approximately 75%. MIL-I-81023 Inductor. One throw only on a SPDT switch during any test procedure. Both throws are evaluated separately. Full switch travel is used. Linear motion. 1 to 3 lbs. from spring-loaded actuators. For application help: call 1-800-537-6945. been extrapolated. For specific switch selection, customers should evaluate switches under actual application conditions or by simulating all application conditions and requirements. The information set forth cannot substitute for the customer’s own product evaulation. It should never be published by a customer as a rating on their product. Honeywell Sensing and Control 97 Reference/Index MICRO SWITCH believes that with the following voltage and current values and under the test conditions set forth below switch life of 100,000 closures, 95% survival can be expected. It is a starting point for user evaluation and provides guidelines on the switches identified. Because of the numerous electrical conditions listed, not every current and voltage level has actually been tested on every switch and certain figures have Basic Switches Definitions of Terms Actuator – Mechanism of the switch or switch enclosure which operates the contacts. Auxiliary Actuator – A mechanism, sold separately, to provide basic switches with easier means of operation and adjustment and adapt switches to different operating motions by supplying supplemental overtravel. Double Break Contacts – (Twin break). This breaks the circuit in two places. Referred to as form Z circuitry also. Precision Snap-Acting Switch – An electromechanical switch having predetermined and accurately controlled characteristics, and having a spring loaded quick make and break contact action. Form Z Basic Switch – A self-contained switching unit. It can be used alone, gangmounted, built into assemblies or enclosed in metal housings. Double-Pole Double-Throw (DPDT) – Switches which make and break two separate circuits. This circuit provides a normally open and normally closed contact for each pole. Bifurcated Contacts – A movable contact, generally gold plated, which is forked to provide two contact mating surfaces in a parallel, for more reliable contact. Enclosed Switch – A basic switch unit (contact block) enclosed in a durable metal housing. The enclosure protects the switching unit, provides mounting means, and fitting for conduit connection. Break – To open an electrical circuit. Environment-Proof Switch – A switch which is completely sealed to ensure constant operating characteristics. Sealing normally includes an ‘‘O’’ ring on actuator shaft and fused glass-to-metal terminal seals or complete potting and an elastomer plunger-case seal. Break Distance – The minimum open gap distance between stationary and movable objects. Characteristics – This term is used by MICRO SWITCH in a restricted sense and refers only to switch operating characteristics such as pretravel, operating force, etc. Circuit – The contact arrangement with switch actuator and contacts in their normal position. Dead break – Exists in all mechanical switches. Definition: When the switch plunger is being depressed, dead break is non-contact immediately before the plunger reaches the operating point. When the switch plunger is being released, dead break is non-contact immediately before the plunger reaches the release point. Dead break is expressed in distance of plunger travel during which the non-contact occurs. Manufacturing specifications for most BZ/BA basic switches allow a maximum dead break of 0.00005 in. (0,001 mm) measured at the switch plunger. Switches are evaluated while moving the plunger with the switch installed in a 10 VDC, 0.100 ampere circuit. This specifiction does not apply to switches that have been in service or have not received proper handling or storage. For applications sensitive to dead break, call Freeport for information on applicable electrical and mechanical conditions. Dead make – When the switch plunger is being depressed, dead make is non-contact immediately after the plunger reaches the release point. Dead make is expressed as the distance of plunger travel during which the non-contact occurs. Non contact is a failure of open contacts to close (that is, the switch resistance exceeds the specified value) within the specified range of plunger positions. If a plunger position is specified with respect to time, a non-contact is a contact miss. 98 Honeywell Sensing and Control Normally Open Contacts (N.O.) – Provide a normally open circuit when actuator is in free position. Explosion-Proof Switch – A UL listed switch capable of withstanding an internal explosion of a specified gas without igniting surrounding gases. Hermetically Sealed Switch – A switch completely sealed to provide constant operating characteristics. All junctures made with metal-to-metal or glass-tometal fusion. Magnetic Blow-Out Switch – Contains a small permanent magnet which provides a means of switching high d-c loads. The magnet deflects arc to quench it. Maintained Contact Switch – Designed for applications requiring sustained contact after plunger has been released, but with provision for resetting. Projection Contacts – A design in which one or more truncated projections are arranged on the stationary contacts. When closed on the smooth, spherical surface of the opposing contact this configuration tends to break thru oxides and other film contaminants to avoid the particulate contaminants. Used with silver contacts, this design can be a useful substitute for the more expensive gold or gold alloy contact material. Pulse Switch – Provides a single pulse of current for each cycle of operation. Quick Connect Terminal – A plug-in type terminal designed for quick switch wiring. Repeatability – Ability of a switch to repeat its characteristics precisely from one operation to the next operation. Single-Pole Double-Throw (SPDT) – Switch which may either make or break a circuit, depending on how it is wired. Also referred to as form C circuitry. Form C Single-Pole Single-Throw (SPST) – Switch with only one moving and one stationary contact. Available either normally open (N.O.) also referred to as form A circuitry; or normally closed (N.C.) also referred to as form B circuitry. Make – To close or establish an electrical circuit. Momentary Switch – A switch with contacts that return from operated condition to normal condition when actuating force is removed. Unless otherwise stated, all switches in this catalog are momentary. Mounting Dimensions – All dimensions on the mounting dimension drawings in this catalog are subject to change without notice. Request current drawings from the nearest MICRO SWITCH Sales Office or write to Freeport. Normally Closed Contacts (N.C.) – Provide a normally closed circuit when actuator is in free position. Form A Form B Terminal Enclosure – A housing that fits over switch terminals to protect against electrical shock and accidental shorting, and facilitate wiring. Two Circuit Switch – In one position, moving contacts complete one circuit, in the other position, contacts complete another separate circuit. For application help: call 1-800-537-6945. Basic Switches Subminiature US Series PC Terminal Version C NO NC FEATURES 1 MICRO SWITCH’S smallest snap-action switch 1 Choice of low energy or power duty electrical ratings 1 Variety of integral actuators 1 Temperature Range: −25° to +80°C (−13° to +176°F) 1 Weight: 0.2 grams (.007 oz.) – PC terminal type 0.3 grams (.011 oz.) – solder terminal type 1 Form C single-pole double-throw (SPDT) circuitry ELECTRICAL RATINGS Voltage Resistive Load Gold Contacts US10 Type Silver Contacts US20 Type 30 VDC 125 VAC 0.1 A 0.1 A 0.5 A 0.1 A ORDER GUIDE SOLDER TERMINALS Contact Type Actuator Gold, 0.1 Amp A pin plunger O.F. max. grams oz. Solder R.F. min. g ounces P.T. max. mm inches O.T. min. mm inches D.T. max. mm inches O.P mm inches 100 3.527 US10D10A00 10 .353 0,3 .012 0,1 .004 0,1 .004 5,4 ± 0,15 .213 ± .006 C flat lever 25 .88 US10D10C00 2,0 .071 2,4 .094 0,4 .016 0,7 .028 6,4 ± 0,6 .252 ± .024 E simulated roller lever 30 1.058 US10D10E00 2,0 .071 2,2 .087 0,3 .012 0,7 .028 6,7 ± 0,5 .264 ± .020 100 3.527 US20D10A00 10 .353 0,3 .012 0,1 .004 0,1 .004 5,4 ± 0,15 .213 ± .006 C flat lever 25 .88 US20D10C00 2,0 .071 2,4 .094 0,4 .016 0,7 .028 6,4 ± 0,6 .252 ± .024 E simulated roller lever 30 1.058 US20D10E00 2,0 .071 2,2 .087 0,3 .012 0,7 .028 6,7 ± 0,5 .264 ± .020 Silver, 0.5 Amp A pin plunger ORDER GUIDE PC STRAIGHT TERMINALS O.F. max. grams oz. PC Straight Cross-Line R.F. min. g ounces P.T. max. mm inches O.T. min. mm inches D.T. max. mm inches O.P mm inches 100 3.527 US10D20A00 10 .353 0,3 .012 0,1 .004 0,1 .004 4,8 ± 0,15 .189 ± .006 C flat lever 25 .88 US10D20C00 1,0 .035 2,4 .094 0,4 .016 0,7 .028 5,8 ± 0,7 .228 ± .028 E simulated roller lever 30 1.058 US10D20E00 1,0 .035 2,2 .087 0,3 .012 0,7 .028 6,1 ± 0,7 .240 ± .028 100 3.527 US20D20A00 10 .353 0,3 .012 0,1 .004 0,1 .004 4,8 ± 0,15 .189 ± .006 C flat lever 25 .88 US20D20C00 1,0 .035 2,4 .094 0,4 .016 0,7 .028 5,8 ± 0,7 .228 ± .028 E simulated roller lever 30 1.058 US20D20E00 1,0 .035 2,2 .087 0,3 .012 0,7 .028 6,1 ± 0,7 .240 ± .028 Contact Type Actuator Gold, 0.1 Amp A pin plunger Silver, 0.5 Amp A pin plunger OTHER TERMINATION TYPES ARE AVAILABLE For PC right angle, change 2nd set of numbers to 50 (Example: US10D50A00) For PC left angle, change 2nd set of numbers to 60 (Example: US10D60A00) 8 HoneywelSensing and Control For application help: call 1-800-537-6945. Basic Switches Subminiature US Series MOUNTING DIMENSIONS mm (for reference only) in. Solder Terminal Switches (with mounting holes) Pin plunger (Type A) Flat lever (Type C) Simulated roller (Type E) PC Board Terminals Switches Pin plunger (Type A) Right angle terminal (Type 50) Miniature/ Subminiature Left angle terminal (Type 60) Flat lever (Type C) Simulated roller (Type E) Mounting screw size is m 1,4. Maximum tightening torque is 1 kg-cm. For application help: call 1-800-537-6945. Honeywell Sensing and Control 9 Basic Switches Subminiature UX Series NC C NO ELECTRICAL RATINGS (in amps) FEATURES 1 Compact size – helps minimize equipment size 1 Choice of low energy or power duty electrical ratings 1 Variety of integral actuators 1 Temperature Range: –25° to +85°C (–13 to 185°F) 1 Weight: 0.5 grams (.018 oz.) 1 UL/CSA marking designations 1 Form C single-pole double-throw (SPDT) circuitry Silver Contacts UX40 Type UX30 Type Voltage 125 VAC* 30 VDC 6 VDC 12 VDC 24 VDC 3A 2A – – – Gold Contacts UX10 Type 1A 1A – – – 0.1 A 0.1 A 5 mA 2 mA 1 mA *UL/CSA rating. UL File No. E12252. UL Standard 1054.CSA file LR23413M167 ORDER GUIDE Terminals Rating Gold, 0.1 Amp 125 VAC Solder PC Straight SelfSupporting 75 2.65 UX10C10A01 UX10C30A01 10 .353 0,5 .020 0,25 .010 0,12 .005 5,5 ± 0,2 .217 ± .008 150 5.3 UX10E10A01 UX10E30A01 20 .705 0,5 .020 0,25 .010 0,12 .005 5,5 ± 0,2 .217 ± .008 25 .88 UX10C10C01 UX10C30C01 2,5 .088 2,1 .083 0,55 .022 0,50 .020 6,8 ± 1,0 .268 ± .039 50 1.76 UX10E10C01 UX10E30C01 5,0 .176 2,1 .083 0,55 .022 0,50 .020 6,8 ± 1,0 .268 ± .039 27 .95 55 1.94 UX10C10E01 UX10C30E01 UX10E10E01 UX10E30E01 2,0 .071 4,0 .141 2,1 .083 2,1 .083 0,50 .020 0,50 .020 0,50 .020 0,50 .020 9,5 ± 1,0 .374 ± .039 9,5 ± 1,0 .374 ± .039 A pin plunger 75 2.65 UX30C10A01 UX30C30A01 10 .353 0,5 .020 0,25 .010 0,12 .005 5,5 ± 0,2 .217 ± .008 C flat lever 25 .88 UX30C10C01 UX30C30C01 2,5 .088 2,1 .083 0,55 .022 0,50 .020 6,8 ± 1,0 .268 ± .039 E roller lever simulated 27 .95 UX30C10E01 UX30C30E01 2,0 .071 2,1 .083 0,50 .020 0,50 .020 9,5 ± 1,0 .374 ± .039 A pin plunger 150 5.3 UX40E10A01 UX40E30A01 20 .705 0,5 .020 0,25 .010 0,12 .005 5,5 ± 0,2 .217 ± .008 C flat lever 50 1.76 UX40E10C01 UX40E30C01 5,0 .176 2,1 .083 0,55 .022 0,50 .020 6,8 ± 1,0 .268 ± .039 E roller lever simulated 55 1.94 UX40E10E01 UX40E30E01 4,0 .141 2,1 .083 0,50 .020 0,50 .020 9,5 ± 1,0 .374 ± .039 Actuator A pin plunger C flat lever E roller lever simulated Silver, 1 Amp 125 VAC Silver, 3 Amp 125 VAC O.F. max. grams oz. R.F. min. P.T. max. O.T. min. D.T. max. g mm mm mm ounces inches inches inches OTHER TERMINATION TYPES ARE AVAILABLE For PC right angle, change 2nd set of numbers to 50 (Example: UX10C50A01) For PC left angle, change 2nd set of numbers to 60 (Example: UX10C60A01) 10 Honeywell Sensing and Control For application help: call 1-800-537-6945. O.P mm inches Basic Switches Subminiature UX Series MOUNTING DIMENSIONS (for reference only) mm in. Pin plunger (Type A) Solder terminals – Type 10 PC board terminals – Type 30 PC board mounting Type 50 Type 60 Miniature/ Subminiature LEVER ACTUATORS UX Series switches with lever actuators can be operated by cams or slides. They require lower operating forces than pin plunger switches. Flat levers are .520 in. (13,2 mm) long and simulated roller levers are .480 in. (12,2 mm) long. Flat lever (Type C) Simulated Roller Lever (Type E) Mounting screw size is 2 mm. Maximum tightening torque is 1 kg-cm. For application help: call 1-800-537-6945. Honeywell Sensing and Control 11 Basic Switches Subminiature UM Series C NO NC ELECTRICAL RATINGS (in amps) FEATURES 1 Choice of low energy or power duty electrical ratings 1 Variety of integral actuators 1 Temperature Range: −25° to +85°C (−13° to 185°F) 1 Weight: 2 grams (.07 oz.) 1 UL/CSA/VDE/SEMKO marking designations 1 Form C single-pole double-throw (SPDT) circuitry Voltage UM50E Silver Contacts Resistive Inductive 125 VAC 250 VAC 30 VDC 5 5 5 3 3 3* UM40B/D Silver Contacts Resistive Inductive 3 3 3 2 2 2* UM10A/B/D/E Gold Contacts Resistive 0.1 0.1 0.1 *Time constant for DC inductive loads: less than 7 msec. UL File No. E12252, CSA File LR23413M167 ORDER GUIDE 0.1 AMP TYPE GOLD CONTACTS Rating Actuator Length O.F. max. grams oz. A pin plunger 0.1 Amp 250 VAC B flat lever 18mm C flat lever 20mm D flat lever 26mm Honeywell Sensing and Control Solder .110 QC O.P mm inches 25 .88 UM10A10A01 UM10A70A01 2 .071 0,6 .024 0,4 .016 0,1 .004 8,4 ± 0,3 .331 ± .012 50 1.76 UM10B10A01 UM10B70A01 7,5 .265 0,6 .024 0,4 .016 0,1 .004 8,4 ± 0,3 .331 ± .012 100 3.57 UM10D10A01 UM10D70A01 15 .529 0,6 .024 0,4 .016 0,1 .004 8,4 ± 0,3 .331 ± .012 150 5.3 UM10E10A01 UM10E70A01 20 .705 0,6 .024 0,4 .016 0,1 .004 8,4 ± 0,3 .331 ± .012 10 .35 20 .7 UM10A10B01 UM10A70B01 0,4 .014 1,7 .060 2,5 .098 2,5 .098 0,8 .031 0,8 .031 0,5 .020 0,5 .020 8,8 ± 0,8 .346 ± .031 8,8 ± 0,8 .346 ± .031 UM10B10B01 UM10B70B01 40 1.4 UM10D10B01 UM10D70B01 3,5 .123 2,5 .098 0,8 .031 0,5 .020 8,8 ± 0,8 .346 ± .031 60 2.1 UM10E10B01 UM10E70B01 4,0 .141 2,5 .098 0,8 .031 0,5 .020 8,8 ± 0,8 .346 ± .031 8 .28 16 .56 UM10A10C01 UM10A70C01 0,35 .012 1,5 .053 2,8 .110 2,8 .110 1,2 .047 1,2 .047 0,8 .031 0,8 .031 8,8 ± 0,8 .346 ± .031 8,8 ± 0,8 .346 ± .031 UM10B10C01 UM10B70C01 35 1.23 UM10D10C01 UM10D70C01 3,0 .106 2,8 .110 1,2 .047 0,8 .031 8,8 ± 0,8 .346 ± .031 55 2 UM10E10C01 UM10E70C01 3,5 .123 2,8 .110 1,2 .047 0,8 .031 8,8 ± 0,8 .346 ± .031 12 .4 25 .88 UM10B10D01 UM10B70D01 1,2 .042 2,5 .088 3,5 .138 3,5 .138 1,6 .063 1,6 .063 1,0 .039 1,0 .039 8,8 ± 1,2 .346 ± .047 8,8 ± 1,2 .346 ± .047 3,0 .106 3,5 .138 1,6 .063 1,0 .039 8,8 ± 1,2 .346 ± .047 45 1.6 12 R.F. min. P.T. max. O.T. min. D.T. max. g mm mm mm ounces inches inches inches Terminals UM10D10D01 UM10D70D01 UM10E10D01 UM10E70D01 For application help: call 1-800-537-6945. Basic Switches Subminiature UM Series ORDER GUIDE 0.1 AMP TYPE GOLD CONTACTS cont. Rating 0.1 Amp 250 VAC 0.1 Amp 250 VAC Actuator Length J flat lever 60mm E simulated roller lever, radius 2,5mm, 19mm H simulated roller lever, radius 1,3mm, 19mm F roller lever 18,00mm Terminals R.F. min. g ounces P.T. max. mm inches O.T. min. D.T. max. mm mm inches inches O.P mm inches Solder .110 QC 6 .2 UM10B10J01 UM10B70J01 0,5 .018 8,5 .335 2,2 .087 2,5 .098 8,8 ± 2,4 .346 ± .094 15 .52 UM10D10J01 UM10D70J01 1,0 .035 8,5 .335 2,2 .087 2,5 .098 8,8 ± 2,4 .346 ± .094 20 .7 UM10E10J01 UM10E70J01 1,0 .035 8,5 .335 2,2 .087 2,5 .098 8,8 ± 2,4 .346 ± .094 16 .56 UM10B10E01 UM10B70E01 1,5 .053 2,8 .110 1,2 .047 0,8 .031 11,65 ± 0,8 .459 ± .031 35 1.23 UM10D10E01 UM10D70E01 3,0 .106 2,8 .110 1,2 .047 0,8 .031 11,65 ± 0,8 .459 ± .031 55 2 UM10E10E01 UM10E70E01 3,5 .123 2,8 .110 1,2 .047 0,8 .031 11,65 ± 0,8 .459 ± .031 16 .56 UM10B10H01 UM10B70H01 1,5 .053 2,8 .110 1,2 .047 0,8 .031 10,7 ± 0,8 .421 ± .031 35 1.23 UM10D10H01 UM10D70H01 3,0 .106 2,8 .110 1,2 .047 0,8 .031 10,7 ± 0,8 .421 ± .031 55 2 UM10E10H01 UM10E70H01 3,5 .123 2,8 .110 1,2 .047 0,8 .031 10,7 ± 0,8 .421 ± .031 20 .7 UM10B10F01 UM10B70F01 1,7 .060 2,5 .098 0,8 .031 0,5 .020 14,50 ± 0,8 .571 ± .031 40 1.4 UM10D10F01 UM10D70F01 3,5 .123 2,5 .098 0,8 .031 0,5 .020 14,50 ± 0,8 .571 ± .031 60 2.1 UM10E10F01 UM10E70F01 4,0 .141 2,5 .098 0,8 .031 0,5 .020 14,50 ± 0,8 .571 ± .031 OTHER TERMINATION TYPES ARE AVAILABLE For PC Straight cross-line, change 2nd set of numbers to 20 (Example: UM10A20A01) For PC Straight international, change 2nd set of numbers to 40 (Example: UM10A40A01) For PC Straight right angle, change 2nd set of numbers to 50 (Example: UM10A50A01) For PC Straight left angle, change 2nd set of numbers to 60 (Example: UM10A60A01) For application help: call 1-800-537-6945. Honeywell Sensing and Control 13 Miniature/ Subminiature 0.1 Amp 250 VAC O.F. max. grams oz. Basic Switches Subminiature UM Series ORDER GUIDE 3 AND 5 AMP TYPE SILVER CONTACTS Rating 3 Amp 250 VAC 3 Amp 250 VAC Actuator Length O.F. max. grams oz. P.T. max. mm inches O.T. min. D.T. max. mm mm inches inches Solder .110 QC UM40B70A01 7,5 .265 0,6 .024 0,4 .016 0,1 .004 8,4 ± 0,3 .331 ± .012 100 3.527 UM40D10A01 UM40D70A01 15,0 .529 0,6 .024 0,4 .016 0,1 .004 8,4 ± 0,3 .331 ± .012 20 .7 UM40B10B01 UM40B70B01 1,7 .060 2,5 .098 0,8 .031 0,5 .020 8,8 ± 0,8 .346 ± .031 40 1.4 UM40D10B01 UM40D70B01 3,5 .123 2,5 .098 0,8 .031 0,5 .020 8,8 ± 0,8 .346 ± .031 16 .56 UM40B10C01 UM40B70C01 1,5 .053 2,8 .110 1,2 .047 0,8 .031 8,8 ± 0,8 .346 ± .031 35 1.23 UM40D10C01 UM40D70C01 3,0 .106 2,8 .110 1,2 .047 0,8 .031 8,8 ± 0,8 .346 ± .031 12 .4 UM40B10D01 UM40B70D01 1,2 .042 3,5 .138 1,6 .063 1,0 .039 8,8 ± 1,2 .346 ± .047 25 .88 UM40D10D01 UM40D70D01 2,5 .088 3,5 .138 1,6 .063 1,0 .039 8,8 ± 1,2 .346 ± .047 6 .2 UM40B10J01 UM40B70J01 0,5 .018 8,5 .335 2,2 .087 2,5 .098 8,8 ± 2,4 .346 ± .094 15 .52 UM40D10J01 UM40D70J01 1,0 .035 8,5 .335 2,2 .087 2,5 .098 8,8 ± 2,4 .346 ± .094 16 .56 UM40B10E01 UM40B70E01 1,5 .053 2,8 .110 1,2 .047 0,8 .031 11,65 ± 0,8 .459 ± .031 35 1.23 UM40D10E01 UM40D70E01 3,0 .106 2,8 .110 1,2 .047 0,8 .031 11,65 ± 0,8 .459 ± .031 16 .56 UM40B10H01 UM40B70H01 1,5 .053 2,8 .110 1,2 .047 0,8 .021 10,7 ± 0,8 .421 ± .031 35 1.23 UM40D10H01 UM40D70H01 3,0 .106 2,8 .110 1,2 .047 0,8 .031 10,7 ± 0,8 .421 ± .031 20 .7 UM40B10F01 UM40B70F01 1,7 .060 2,5 .098 0,8 .031 0,5 .020 14,50 ± 0,8 .571 ± .031 40 1.4 UM40D10F01 UM40D70F01 3,5 .123 2,5 .098 0,8 .031 0,5 .020 14,50 ± 0,8 .571 ± .031 A pin plunger 150 5.3 UM50E10A01 UM50E70A01 20 .705 0,6 .024 0,4 .016 0,1 .004 8,4 ± 0,3 .331 ± .012 B flat lever 18mm 60 2.1 UM50E10B01 UM50E70B01 4,0 .141 2,5 .098 0,8 .031 0,5 .020 8,8 ± 0,8 .346 ± .031 C flat lever 20mm 55 2 UM50E10C01 UM50E70C01 3,5 .123 2,8 .110 1,2 .047 0,8 .031 8,8 ± 0,8 .346 ± .031 D flat lever 26mm 45 1.6 UM50E10D01 UM50E70D01 3,0 .106 3,5 .138 1,6 .063 1,0 .039 8,8 ± 1,2 .346 ± .047 UM50E10J01 UM50E70J01 1,0 .035 8,5 .335 2,2 .087 2,5 .098 8,8 ± 2,4 .346 ± .094 B flat lever 18mm J flat lever 60mm E simulated roller lever, radius 2,5mm 19mm H simulated roller lever, radius 1,3mm 19,15mm F roller lever 18mm J flat lever 60mm E simulated roller lever, radius 2,5mm 19mm 55 2 UM50E10E01 UM50E70E01 3,5 .123 2,8 .110 1,2 .047 0,8 .031 11,65 ± 0,8 .459 ± .031 H simulated roller lever, radius 1,3mm 19mm 55 2 UM50E10H01 UM50E70H01 3,5 .123 2,8 .110 1,2 .047 0,8 .031 10,7 ± 0,8 .421 ± .031 F roller lever 18mm 60 2.1 UM50E10F01 UM50E70F01 4,0 .141 2,5 .098 0,8 .031 0,5 .020 14,50 ± 0,8 .571 ± .031 OTHER TERMINATION TYPES ARE AVAILABLE For PC Straight cross-line, change 2nd set of numbers to 20 (Example: UM40B20A01) For PC Straight international, change 2nd set of numbers to 40 (Example: UM40B40A01) For PC Straight right angle, change 2nd set of numbers to 50 (Example: UM40B50A01) For PC Straight left angle, change 2nd set of numbers to 60 (Example: UM40B60A01) 14 O.P mm inches UM40B10A01 D flat lever 26mm 5 Amp 250 VAC R.F. min. g ounces 50 1.76 A pin plunger C flat lever 20mm 3 Amp 250 VAC Terminals Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Subminiature UM Series MOUNTING DIMENSIONS (for reference only) mm in. Pin Plunger Type A PC Straight Cross-Line – Type 20 PC Straight In-line – Type 40 PC Right Angle In-line – Type 50 PC Left Angle In-line – Type 60 QC Quick Connect – Type 70 18mm Flat Lever Type B 20mm Flat Lever Type C 26mm Flat Lever Type D 60mm Type J 19mm Simulated Roller Type E/H Type H has 1,3mm radius Type E has 2,5mm radius 18mm Roller Lever Type F 5mm (.197 in.) dia. x 3,2mm (.126 in.) thick roller Miniature/ Subminiature Solder Cross-line Terminals – Type 10 Lever Actuators 4mm (.158) wide Mounting screw size is m 2,3. Maximum tightening torque is 3 kg-cm. For application help: call 1-800-537-6945. Honeywell Sensing and Control 15 Basic Switches Sealed Subminiature IP50-SEALED FEATURES 1 Silver or gold contacts 1 Variety of integral actuator styles including pin plunger, flat lever, roller lever, and simulated roller lever 1 IP50 or IP67 type sealing 1 Choice of quick-connect, printed circuit board, solder or leadwire termination 1 Form C single-pole double-throw 1 Temperature range: −40° to 85°C (−40° to 185°F) 1 Weight, approx.: .07 oz. (2g.) for IP50-sealed switches; and .14 oz. (4g.) for IP67-sealed switches, not including leadwires 1 UL, CSA, VDE, and SEMKO marking designations UM Series IP67-SEALED ELECTRICAL RATINGS (in amps) Voltage 125 VAC 250 VAC 30 VDC 125 VDC Silver Contacts Resistive Inductive 2.0 2.0 2.0 0.4 2.0 2.0 2.0 0.05 Gold Contacts Resistive 0.1A 0.1A 0.1A — UL File No. E12252, CSA File LR23413M167 IP50-sealed UM switches are the same size as non-sealed UM switches on pages 12-15. There is an elastomer seal on the switch plunger and a cover-tocase seal. They provide a degree of protection against the entry of dust. IP67-sealed UM switches have the plunger seal and cover-to-case seal. In addition, their AWG #20 leadwires are molded in epoxy resin. They provide a degree of protection against water entry during temporary immersion. 16 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches IP50-Sealed Subminiature C NO UM Series NC ORDER GUIDE IP50 SEALED 0.1-AMP GOLD CONTACTS Actuators O.F. max. grams oz. Termination Solder .110 QC R.F. min. grams ounces P.T. max. mm inches O.T. min. mm inches D.T. max. mm inches O.P mm inches pin plunger 150 5.3 UM10E11AS1 UM10E71AS1 20 .705 0,6 .024 0,4 .016 0,1 .004 8,4 ± 0,3 .331 ± .012 B flat lever 60 2.1 UM10E11BS1 UM10E71BS1 4,0 .141 2,5 .098 0,8 .031 0,5 .020 8,8 ± 0,8 .346 ± .031 C flat lever 55 1.9 UM10E11CS1 UM10E71CS1 3,5 .123 2,8 .110 1,2 .047 0,8 .031 8,8 ± 0,8 .346 ± .031 D flat lever 45 1.6 UM10E11DS1 UM10E71DS1 3,0 .106 3,5 .138 1,6 .063 1,0 .039 8,8 ± 1,2 .346 ± .047 E simulated roller lever 55 1.9 UM10E11ES1 UM10E71ES1 3,5 .123 2,8 .110 1,2 .047 0,8 .031 11,65 ± 0,8 .459 ± .031 F roller lever 60 2.1 UM10E11FS1 UM10E71FS1 4,0 .141 2,5 .098 0,8 .031 0,5 .020 14,5 ± 0,8 .571 ± .031 R.F. min. grams ounces P.T. max. mm inches O.T. min. mm inches D.T. max. mm inches O.P mm inches ORDER GUIDE IP50 SEALED 2.0-AMP SILVER CONTACTS Actuators O.F. max. grams oz. Termination Solder .110 QC A pin plunger 150 5.3 UM35E11AS1 UM35E71AS1 20 .705 0,6 .024 0,4 .016 0,1 .004 8,4 ± 0,3 .331 ± .012 B flat lever 60 2.1 UM35E11BS1 UM35E71BS1 4,0 .141 2,5 .098 0,8 .031 0,5 .020 8,8 ± 0,8 .346 ± .031 C flat lever 55 1.9 UM35E11CS1 UM35E71CS1 3,5 .123 2,8 .110 1,2 .047 0,8 .031 8,8 ± 0,8 .346 ± .031 D flat lever 45 1.6 UM35E11DS1 UM35E71DS1 3,0 .106 3,5 .138 1,6 .063 1,0 .039 8,8 ± 1,2 .346 ± .047 E simulated roller lever 55 1.9 UM35E11ES1 UM35E71ES1 3,5 .123 2,8 .110 1,2 .047 0,8 .031 11,65 ± 0,8 .459 ± .031 F roller lever 60 2.1 UM35E11FS1 UM35E71FS1 4,0 .141 2,5 .098 0,8 .031 0,5 .020 14,5 ± 0,8 .571 ± .031 TO SPECIFY PC TERMINALS: In the order guides above, change the 2nd set of numbers to 21. Example: UM10E11AS1 converts to UM10E21AS1 with PC terminals For application help: call 1-800-537-6945. Honeywell Sensing and Control 17 Miniature/ Subminiature A Basic Switches IP67-Sealed Subminiature C NO UM Series NC ORDER GUIDE IP67 SEALED 0.1-AMP GOLD AND 2.0-AMP SILVER CONTACTS Actuators O.F. max. grams oz. Leadwire Termination R.F. min. grams ounces P.T. max. mm inches O.T. min. mm inches D.T. max. mm inches O.P mm inches Gold Contacts Silver Contacts A pin plunger 150 5.3 UM10E90AS1 UM35E90AS1 20 .705 0,6 .024 0,4 .016 0,1 .004 8,4 ± 0,3 .331 ± .012 B flat lever 60 2.1 UM10E90BS1 UM35E90BS1 4,0 .141 2,5 .098 0,8 .031 0,5 .020 8,8 ± 0,8 .346 ± .031 C flat lever 55 1.9 UM10E90CS1 UM35E90CS1 3,5 .123 2,8 .110 1,2 .047 0,8 .031 8,8 ± 0,8 .346 ± .031 D flat lever 45 1.6 UM10E90DS1 UM35E90DS1 3,0 .106 3,5 .138 1,6 .063 1,0 .039 8,8 ± 1,2 .346 ± .047 E simulated roller lever 55 1.9 UM10E90ES1 UM35E90ES1 3,5 .123 2,8 .110 1,2 .047 0,8 .031 11,65 ± 0,8 .459 ± .031 F roller lever 60 2.1 UM10E90FS1 UM35E90FS1 4,0 .141 2,5 .098 0,8 .031 0,5 .020 14,5 ± 0,8 .571 ± .031 MOUNTING DIMENSIONS (For reference only) mm in. Mounting screw size is m 2,3 Maximum torque is 3 kg/cm. Pin Plunger Type A PC Terminals 18 Honeywell Sensing and Control Solder In-line Terminals For application help: call 1-800-537-6945. Basic Switches IP50-Sealed Subminiature MOUNTING DIMENSIONS (For reference only) mm in. UM Series Mounting screw size is m 2,3 Maximum torque is 3 kg/cm. Pin Plunger Type A QC In-line Terminals Leadwires Miniature/ Subminiature Lever Actuators 4 mm/.158 in. wide 18 mm Flat Lever Type B 19 mm Simulated Roller Lever Type E 2,5 mm radius 20 mm Flat Lever Type C 18 mm Roller Lever Type F 5 mm/.197 in. dia. x 3,2 mm/.126 in. Thick Roller 26 mm Flat Lever Type D For application help: call 1-800-537-6945. Honeywell Sensing and Control 19 Basic Switches Subminiature SX Series CUT-A-WAY 1SX SUBMINIATURE BASIC SWITCH T GENERAL INFORMATION SX subminiature basic switches are small size precision snap-action switches from MICRO SWITCH. These switches are ideal where savings in space and weight are important. Unless otherwise noted, all listings have silver contacts. T2 Mounting torque Round head 2-56 UNC 438 screws— 2 inch pounds max. H58 STRAIGHT PIN H391, H392 90° FORMED PIN Mate with Amp Inc. Part No. 640024-1 Std. Dimensions shown are for reference only This section covers only 40 of our most popular SX Series catalog listings. If you don’t find what you’re looking for, it’s likely one of the approximately 200 other active SX listings will meet your needs. Contact the 800 number. For application help: call 1-800-537-6945. Honeywell Sensing and Control 21 Miniature/ Subminiature AVAILABLE TERMINALS SX switches are available with several types of terminations. The T and T2 terminals provide easy solder lead wire attachment. The H58 terminal offers the simplicity of quick-connect and mate with AMP .058-inch receptacles. Pin terminals allow easy attachment to printed circuit boards. FEATURES 1 Low operating force to 3 oz. (85 grams) maximum 1 Sensitive differential travel as low as .001 inch maximum 1 Power load switching capability up to 7 amperes—silver contacts 1 Optional gold contacts for low energy applications 1 Optional bifurcated gold contacts for maximum reliability 1 Long mechanical life up to 10,000,000 cycles—95% survival for 11SX series 1,000,000 cycles—95% survival for 1SX series 1 Temperature tolerance −65° to +250°F (−54 to 121°C) on standard construction 1 High temperature designs for up to +400°F (204°C) for 100 hours 1 Variety of integral and auxiliary actuators 1 Choice of several terminal styles 1 MIL-S-8805 qualified products available 1 UL recognized File #E12252, CSA certified file # LR41372 Basic Switches Subminiature SX Series ORDER GUIDE by ascending electrical capability PIN PLUNGER Catalog Listing Dim. Dwg. Fig. 1 (Except Fig. 2 for 91SX39-T and 93SX34-T) Recommended for Electrical Data and O.F. max. R.F. min. UL Code newtons newtons Page 20 ounces ounces 11SX91-T Logic level loads 5VDC, 2mA; SPNO At Left 12SX2-T Best reliability (Bifurcated gold contacts) 3SX1-T Applications requiring gold contacts (1SX type) 1 Amp D 12SX1-T Best reliability with higher current rating (Bifurcated gold contacts) 12SX3-T 1,39 5 P.T. max. O.T. min. D.T. max. O.P.* mm mm mm mm inches inches inches inches 0,28 1 0,51 .020 0,1 .004 0,1 .004 8,13 .320 0,28 1 0,51 .020 0,1 .004 0,051 .002 8,13 .320 1,39 5 0,28 1 0,51 .020 0,1 .004 0,13 .005 8,13 .320 1 Amp D 1,39 5 0,28 1 0,51 .020 0,1 .004 0,076 .003 8,13 .320 Lowest differential travel with bifurcated gold contacts 1 Amp H 1,39 5 0,28 1 0,51 .020 0,1 .004 0,025 .001 8,13 .320 13SX21-T Applications requiring gold contacts. 11SX type. 1 Amp D 1,39 5 0,28 1 0,51 .020 0,1 .004 0,051 .002 8,13 .320 23SX39-T (MS24547-2) MIL-S-8805 applications requiring gold contacts +180°F (82°C) max. use 1 Amp D 1,39 5 0,28 1 0,51 .020 0,1 .004 0,13 .005 8,13 .320 23SX39-T2 (MS24547-5) As above, with T2 terminals 1 Amp D 1,39 5 0,28 1 0,51 .020 0,1 .004 0,13 .005 8,13 .320 93SX39-T M8805/109-03 .156N wide, with gold contacts +180°F (82°C) 1 Amp D 1,39 5 0,28 1 0,51 .020 0,1 .004 0,13 .005 8,13 .320 411SX21-T M8805/106-01 +400°F (204°C) for 100 hours G 1,39 5 0,28 1 0,51 .020 0,1 .004 0,13 .005 8,13 .220 413SX21-T M8805/106-02 +400°F (204°C) for 100 hours L 1,39 5 0,28 1 0,51 .020 0,1 .004 0,051 .002 8,13 .220 11SX1-T Lowest differential travel 3 Amps E 0,97 3.5 0,21 0.75 0,51 .020 0,1 .004 0,025 .001 8,13 .320 11SX21-T Most applications 5 Amps A 0,7 to 1,39 2.5 to 5 0,28 1 0,51 .020 0,1 .004 0,051 .002 8,13 .320 11SX22-T For use in sealed enclosures. 5 Amps A 1,39 5 0,28 1 0,51 .020 0,1 .004 0,076 .003 8,13 .320 17SX21-T Best stability under varying humidity. 11SX type. 5 Amps A 1,39 5 0,28 1 0,51 .020 0,1 .004 0,051 .002 8,13 .320 1SX1-T Up to 7 amps load handling 7 Amps B 1,39 5 0,28 1 0,51 .020 0,1 .004 0,13 .005 8,13 .320 1SX12-T Low differential travel 7 Amps C 1,39 5 0,28 1 0,51 .020 0,1 .004 0,051 .002 8,13 .320 1SX48-T Added overtravel 7 Amps B 1,39 5 0,28 1 0,51 .020 0,25 .010 0,13 .005 8,13 .320 2SX1-T Lower force 7 Amps B 0,83 3 0,28 1 0,51 .020 0,1 .004 0,13 .005 8,13 .320 4SX1-T Operating in temperature to +400°F (204°C) for 100 hours 7 Amps I 1,39 5 0,28 1 0,51 .020 0,1 .004 0,13 .005 8,13 .320 21SX1-T Best stability under varying humidity (1SX type) 7 Amps B 1,39 5 0,28 1 0,51 .020 0,1 .004 0,13 .005 8,13 .320 21SX39-T (MS24547-1) MIL-S-8805 application requirements +180°F (82°C) 7 Amps F 1,39 5 0,28 1 0,51 .020 0,1 .004 0,13 .005 8,13 .320 21SX39-T2 (MS24547-4) MIL-S-8805 application requirements +180°F (82°C) 7 Amps F 1,39 5 0,28 1 0,51 .020 0,1 .004 0,13 .005 8,13 .320 91SX39-T M8805/109-01 .156N wide version of standard SX +180°F (82°C) 7 Amps F 1,39 5 0,28 1 0,51 .020 0,1 .004 0,13 .005 8,13 .320 .010 Amp 0,7 to 1.39 H 2.5 to 5 *±0,38 mm ±.015 in. 22 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Subminiature SX Series Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating Position ORDER GUIDE INTEGRAL LEVERS Catalog Listing O.P. mm inches .135 inch (3,43 mm) straight lever 5 Amps A 0,49 1.76 0,09 .32 1,65 .065 0,36 .014 0,51 .020 8,43±1,14 .332±.045 313SX1-T As above with gold contacts 1 Amp D 0,49 1.76 0,09 .32 1,65 .065 0,36 .014 0,51 .020 8,43±1,14 .332±.045 311SX2-T .505 inch (12,8 mm) straight lever 5 Amps A 0,31 1.1 0,05 .18 2,92 .115 0,64 .025 0,89 .035 8,26±1,91 .325±.075 313SX2-T As above with gold contacts 1 Amp D 0,31 1.1 0,05 .18 2,92 .115 0,64 .025 0,89 .035 8,26±1,91 .325±.075 311SX3-T .965 inch (24,5 mm) straight lever 5 Amps A 0,20 .71 0,03 .11 4,70 .185 0,61 .024 1,52 .060 7,75±2,92 .305±.115 313SX3-T As above with gold contacts 1 Amp D 0,20 .71 0,03 .11 4,70 .185 0,61 .024 1,52 .060 7,75±2,92 .305±.115 311SX4-T .042 inch (1,1 mm) simulated roller lever 5 Amps A 0,58 2.1 0,11 .39 1,27 .050 0,25 .010 0,38 .015 14,15±0,91 .557±.036 313SX4-T As above with gold contacts 1 Amp D 0,58 2.1 0,11 .39 1,27 .050 0,25 .010 0,38 .015 14,15±0,91 .557±.036 311SX5-T .459 inch (11,7 mm) simulated roller lever 5 Amps A 0,31 1.1 0,05 .18 2,67 .105 0,56 .022 0,89 .035 14,86±1,65 .585±.065 313SX5-T As above, with gold contacts 1 Amp D 0,31 1.1 0,05 .18 2,67 .105 0,56 .022 0,89 .035 14,86±1,65 .585±.065 Dim. Dwg. Fig. 3 Dim. Dwg. Fig. 4 Dim. Dwg. Fig. 5 For application help: call 1-800-537-6945. Honeywell Sensing and Control 23 Miniature/ Subminiature 311SX1-T Dim. Dwg. Fig. 3 Dim. Dwg. Fig. 6 Description Electrical Data And O.F. max. R.F. min. P.T. max. O.T. min. D.T. max. UL Code newtons newtons mm mm mm Page 20 ounces ounces inches inches inches Basic Switches Subminiature SX Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating Position; F.P. – Free Position. *All characteristics are taken with actuator assembled on Catalog Listing 1SX1-T as shown. ORDER GUIDE AUXILIARY ACTUATORS Switches are not included with actuators. Catalog Listing Description Actuator Length ‘‘A’’ O.F. max. R.F. min. mm newtons newtons inches ounces ounces P.T. mm inches O.T. mm inches D.T. max. mm inches O.P.†† mm inches F.P. mm inches JX-20 Straight lever 18.3 .72 0,28 1 approx. 0,04 .14 — 0,76 .030 approx. 0,76 .030 approx. 10,8 .425 approx. 12,3 .485 approx. JX-219 Straight lever (For higher temp.) 18,3 .72 0,28 1 0,04 .14 — 0,76 .030 approx. 0,76 .030 approx. 10,8 .425 approx. 12,3 .485 approx. JX-25 Roller lever 16,5 .65 0,42 1.5 0,04 1.4 — 0,51 .020 0,76 .030 14,9J1,14 .585J.045 168 .660 max. JX-220 Roller lever (For higher temp.) 16,5 .65 0,42 1.5 0,04 .14 — 0,51 .020 0,76 .030 14,9J1,14 .585J.045 16,8 .660 max. JX-40 Straight leaf 9,4 .37† 1,95 7 0,56 2 .225 approx. 0,38 .015 0,64 .025 7,5 .295 12,3 .485 ref. JX-95 Straight leaf (For higher temp.) 9,4 .37† 1,95 7 0,56 2 .225 approx. 0,38 .015 0,64 .025 7,5 .295 12,3 .485 ref. JX-41** Reverse leaf 9,4 .37† 1,67 6 0,28 1 .110 approx. 0,38 .015 0,64 .025 7,5 .295 9,4 .370 ref. JX-45 Roller leaf 6,1 .24† 1,95 7 0,28 1 .225 approx. 0,38 .015 0,64 .025 12,2 .480 16,5 .650 ref. JX-96 Roller leaf (For higher temp.) 6,1 .24† 1,95 7 0,28 1 .225 approx. 0,38 .015 0,64 .025 12,2 .480 16,5 .650 ref. JX-51** Reverse roller leaf 7,6 .30† 1,67 6 0,56 2 .110 approx. 0,38 .015 0,64 .025 12,8 .505 14,7 .580 ref. JX-4 Tandem leaf 7,9 .31 4,17 15 0,83 3 .065 approx. 0,20 .008 0,76 .030 7,6 .300 9,40 .370 ref. Dim. Dwg. Fig. 7 Dim. Dwg. Fig. 8 Dim. Dwg. Fig. 9 Dim. Dwg. Fig. 9 Dim. Dwg. Fig. 10 24 **Switch is mounted with plunger end reversed from JX-40. †‘‘A’’ measurement is from center of mounting hole nearest tip of lever to the point indicated on drawing. Honeywell Sensing and Control NOTE: Above actuators should be used at temperatures below +300°F (149°C); except listings JX-95, JX-96, JX-219 and JX-220 are for use with the 4SX1-T to 400°F. (204°C). Except where stated †† ±0,76 mm ±.030 in. For application help: call 1-800-537-6945. Basic Switches Subminiature SX Series MOUNTING DIMENSIONS (for reference only) PIN PLUNGER INTEGRAL LEVERS Dim. ‘‘A’’ Fig. 1 Fig. 2 311SX1-T 3,6/.14 311SX2-T 13,0/.51 Fig. 3 INTEGRAL LEVERS Miniature/ Subminiature Interchangeable with 1SX-1T switch with JX-25 actuator. Fig. 4 Fig. 5 Fig. 6 AUXILIARY ACTUATORS Fig. 7 Switches are not included with actuator. For application help: call 1-800-537-6945. Fig. 8 Fig. 9 Fig. 10 Mounting holes accept pins or screws of .087 diameter (2,21 mm). Honeywell Sensing and Control 25 Basic Switches Subminiature SM Series CUT-A-WAY SM SUBMINIATURE BASIC SWITCH AVAILABLE TERMINALS Various terminals are available for most listings. These include: the T and T2 for wrap-around soldering of leadwires; solder terminals for solder connections; H58 terminals and H4 series terminals provide easy quick-connect installation; H2 type, round wire wrap or PC terminals; H6 rectangular wire wrap terminals are also available. Other quick-connect terminals of the Series H types are available. Contact the 800 number for ordering information. T GENERAL INFORMATION SM subminiature switches are slightly larger than the SX switches. These switches combine small size and light weight with ample electrical capacity, precision operation and long life. Unless otherwise noted, all listings have silver contacts. SOLDER T2 FEATURES 1 Low operating force to 2 ounces maximum 1 Sensitive differential travel as low as .001 inch (0,025 mm) maximum 1 Power load switching capability available to 11 amps (VAC) – silver contacts 1 Motor load handling capacity to 1/4 hp (VAC) 1 Optional gold contacts for low energy applications 1 Optional bifurcated gold contacts for maximum reliability 1 Long mechanical life – 11SM Series 10,000,000 operations – 1SM/41SM Series 80,000 operations – Bifurcated contacts 1,000,000 operations All at 95% survival 1 Standard temperature range −65° to +185°F (−54 to 85°C) 1 High temperature construction available for use to +400°F (204°C) for 100 hours 1 Variety of integral and auxiliary actuators 1 Choice of several terminal styles 1 Military Standard construction available with three listings on the MIL-S-8805 qualified products list 1 UL recognized File #E12252, CSA certified File #LR41372 Mounting Torque: 2.3 inch pounds max. H4 H58 H2 Mates with Amp Inc. Part No. 640024-1 Std. Dimensions shown are for reference only This section covers only 38 of our most popular SM Series catalog listings. If you don’t find what you’re looking for, it’s likely one of the approximately 500 other active SM listings will meet your needs. Contact the 800 number. 26 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Subminiature SM Series Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Position. ORDER GUIDE by ascending electrical capability PIN PLUNGERS Catalog Listing O.P.* mm inches 11SM1077-T Gold alloy contacts .1 Amp P 0,83-1,39 3-5 0,28 1 0,51 .020 0,13 .005 0,1 .004 8,38 .330 12SM604-T Bifurcated gold contacts, reduced rating .1 Amp P 0,83-1,39 3-5 0,28 1 0,51 .020 0,076 .003 0,1 .004 8,38 .330 11SM23-T Application requiring gold contacts 1 Amp N 0,83-1,39 3-5 0,28 1 0,51 .020 0,13 .005 0,1 .004 8,38 .330 12SM4-T Best reliability (Bifurcated gold contacts) 1 Amp N 0,83-1,39 3-5 0,28 1 0,51 .020 0,076 .003 0,1 .004 8,38 .330 11SM701-T Lower force 4 Amps S 0,56 2 0,14 .5 0,51 .020 0,13 .005 0,051 .002 8,38 .330 11SM1-T Most applications 5 Amps 0,83-1,39 J 3-5 0,28 1 0,51 .020 0,13 .005 0,1 .004 8,38 .330 11SM3-T Operating in temperatures to +250°F (121°C) 5 Amps 0,83-1,39 J 3-5 0,28 1 0,51 .020 0,13 .005 0,1 .004 8,38 .330 11SM244-T Operating in temperatures 5 Amps 0,83-1,39 to +400°F (204°C) 100 hrs. * 3-5 0,28 1 0,51 .020 0,13 .005 0,1 .004 8,38 .330 11SM401-T Less differential travel 5 Amps K 0,28 1 0,51 .020 0,13 .005 0,025 .001 8,38 .330 21SM284-T2 (MS25085-2) MIL-S-8805 application requirements 5 Amps 0,83-1,39 R 3-5 0,28 1 0,76 .030 0,13 .005 0,1 .004 8,38 .330 21SM284 (MS25085-1) MIL-S-8805 application requirements, solder terminals 5 Amps 0,83-1,39 R 3-5 0,28 1 0,76 .030 0,13 .005 0,1 .004 8,38 .330 22SM1-T Best stability under varying humidity 5 Amps 0,83-1,39 J 3-5 0,28 1 0,51 .020 0,13 .005 0,1 .004 8,38 .330 41SM1-T Up to 11 ampere 1/4 hp (AC) load handling 11 Amps 0,83-1,39 M 3-5 0,28 1 0,76 .030 0,13 .005 0,1 .004 8,38 .330 0,97 3.5 max. *For electrical data call 1-800-537-6945 411SM1 Sealed plunger construction 5 Amps 0,83-2,09 K 3-7.5 0,28 1 0,51 .020 0,13 .005 0,1 .004 8,38 .330 411SM23 As above with gold contacts 1 Amp N 0,28 1 0,51 .020 0,13 .005 0,1 .004 8,38 .330 0,83-2,09 3-7.5 Except where stated * ±0,38mm ±.015 in. For application help: call 1-800-537-6945. Honeywell Sensing and Control 27 Miniature/ Subminiature Dim. Dwg. Fig. 1 Recommended For Electrical Data And O.F. R.F. min. P.T. max. O.T. min. D.T. max. UL Code newtons newtons mm mm mm Page 20 ounces ounces inches inches inches Basic Switches Subminiature SM Series Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Position. ORDER GUIDE INTEGRAL LEVERS Catalog Listing .285 inch (7,24mm) straight lever 5 Amps J 0,39 1.4 0,07 .25 2,16 .085 0,51 .020 0,48 .019 8,64±1,5 .340±.060 311SM23-T As above with gold contacts 1 Amp N 0,39 1.4 0,07 .25 2,16 .085 0,51 .020 0,48 .019 8,64±1,5 .340±.060 311SM701-T .285 inch (7,24mm) straight lever. Lower force 4 Amps S 0,16 .57 0,03 .11 2,16 .085 0,51 .020 0,36 .014 8,64±1,5 .340±.060 311SM2-T .565 inch (14,35mm) straight lever 5 Amps J 0,31 1.1 0,05 .18 3,05 .120 0,66 .026 0,69 .027 8,51±2 .335±.080 311SM43-T As above with gold contacts 1 Amp N 0,31 1.1 0,05 .18 3,05 .120 0,66 .026 0,69 .027 8,51±2 .335±.080 311SM702-T .565 inch (14,35mm) straight lever. Lower force 4 Amps S 0,11 .4 0,02 .07 3,05 .120 0,66 .026 0,38 .015 8,51±2 .335±.080 311SM3-T 1.765 inch (44,8mm) straight lever 5 Amps J 0,15 .53 0,02 .07 7,87 .310 1,45 .057 2,8 .110 7,11±4,3 .280±.170 311SM17-H58 As above with gold contacts 1 Amp N 0,15 .53 0,02 .07 7,87 .310 1,45 .057 2,8 .110 7,11±4,3 .280±.170 311SM703-T 1.765 inch (44,8mm) straight lever. Lower force 4 Amps S 0,06 .2 0,01 .04 7,87 .310 1,45 .057 1,78 .070 7,11±4,3 .280±170 311SM4-T .251 inch (6,38mm) simulated roller lever 5 Amps J 0,39 1.4 0,07 .25 2,16 .085 0,46 .018 0,48 .019 11,7±1,5 .460±.060 311SM25-T As above with gold contacts 1 Amp N 0,39 1.4 0,07 .25 2,16 .085 0,46 .018 0,48 .019 11,7±1,5 .460±.060 311SM704-T .251 inch (6,38mm) simulated roller lever. Lower force 4 Amps S 0,16 .57 0,03 .11 2,16 .085 0,46 .018 0,33 .013 11,7±1,5 .460±.060 311SM5-T .535 inch (13,6mm) simulated roller lever 5 Amps J 0,31 1.1 0,05 .18 3,05 .120 0,66 .026 0,69 .027 11,56±2 .455±.080 311SM705-T .535 inch (13,6mm) simulated roller lever. Lower force 4 Amps S 0,11 .4 0,02 .07 3,05 .120 0,66 .026 0,38 .015 11,56±2 .455±.080 311SM6-T .251 inch (6,38mm) roller lever 5 Amps J 0,39 1.4 0,07 .25 2,16 .085 0,46 .018 0,48 .019 14,2±1,5 .560±.060 311SM68-T As above with gold contacts 1 Amp N 0,39 1.4 0,07 .25 2,16 .085 0,46 .018 0,48 .019 14,2±1,5 .560±.060 311SM706-T .251 inch (6,38mm) roller lever. Lower force 4 Amps S 0,16 .57 0,03 .11 2,16 .085 0,46 .018 0,33 .013 14,2±1,5 .560±.060 311SM7-T .535 inch (13,6mm) roller lever 5 Amps J 0,31 1.1 0,05 .18 3,05 .120 0,66 .026 0,69 .027 14,1±2 .555±.080 Dim. Dwg. Fig. 6 Dim. Dwg. Fig. 7 Dim. Dwg. Fig. 8 Dim. Dwg. Fig. 9 Dim. Dwg. Fig. 10 28 O.P. mm inches 311SM1-T Dim. Dwg. Fig. 4 Dim. Dwg. Fig. 5 Description Electrical Data And O.F. max. R.F. max. P.T. max. O.T. min. D.T. max. UL Code newtons newtons mm mm mm Page 20 ounces ounces inches inches inches Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Subminiature SM Series ORDER GUIDE INTEGRAL LEAF Catalog Listing Dim. Dwg. Fig. 11 Recommended For Electrical Data And O.F. max. R.F. min. P.T. max. O.T. min. D.T. max. UL Code newtons newtons mm mm mm Page 20 ounces ounces inches inches inches O.P. mm inches 111SM1-T Force and stability of flexible leaf actuator 5 Amps J 1,95 7 0,56 2 5,54 .218 0,76 .030 0,76 .030 8,89±0,76 .350±.030 111SM17-T As above with gold contacts 1 Amp N 1,95 7 0,56 2 5,54 .218 0,76 .030 0,76 .030 8,89±0,76 .350±.030 111SM2-T Flexible leaf with roller 5 Amps J 1,95 7 0,56 2 5,56 .219 0,76 .030 0,64 .025 14,3±0,76 .562±.030 111SM23-T As above with gold contacts 1 Amp N 1,95 7 0,56 2 5,56 .219 0,76 .030 0,64 .025 14,3±0,76 .562±.030 Dim. Dwg. Fig. 12 Miniature/ Subminiature For application help: call 1-800-537-6945. Honeywell Sensing and Control 29 Basic Switches Subminiature SM Series Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Position; F.P. — Free Position AUXILIARY ACTUATORS * All characteristics are taken with actuator assembled to Catalog Listing 11SM3-T as shown. ORDER GUIDE Switches are not included with the actuators. Catalog Listing Description Actuator Length ‘‘A’’ O.F. max. R.F. min. mm newtons newtons inches ounces ounces P.T. max. mm inches O.T. min. D.T. max. mm mm inches inches O.P. mm inches F.P. max. mm inches JS-2 Straight leaf 16,8 .66 2,78 10 0,56 2 1,98 .078 0,38 .015 0,38 .015 8,89±0,38 .350±.015 11,3 .445 JS-5 Roller leaf (Bronze roller) 15 .59 2,78 10 0,83 3 1,98 .078 0,38 .015 0,38 .015 14,2±0,38 .580±.015 16,9 .665 JS-7 Formed leaf (Simulated roller) 14,7 .58 2,78 10 0,56 2 2,39 .094 0,79 .031 0,38 .015 9,65±0,38 .380±.015 12,1 .475 JS-220 Straight lever 26,2† 1.03 0,28 1 0,04 .14 3,18 .125 approx. 0,76 .030 0,76 .030 10,3 .406 approx. — JS-246 Roller lever (Steel roller) 25,4† 1.00 0,28 1 0,04 .14 3,18 .125 approx. 0,76 .030 0,76 .030 14,3 .562 approx. — JS-221 Formed lever (Simulated roller) 25,4† 1.00 0,28 1 0,04 .14 3,18 .125 approx. 0,76 .030 0,76 .030 11,6 .455 approx. — JS-33** Tandem leaf 5,3 .21 5,00 18 2,78 10 2,36 .093 0,15 .006 0,38 .015 8,89±0,38 .350±.015 10,5 .415 JS-31** Tandem roller leaf (Bronze roller) 4,3 .17 11,1 40 4,45 16 2,36 .093 0,13 .005 0,38 .015 14,5±0,38 .570±.015 16,1 .635 Dim. Dwg. Fig. 14 Dim. Dwg. Fig. 14 Dim. Dwg. Fig. 14 Dim. Dwg. Fig. 16 Dim. Dwg. Fig. 16 Dim. Dwg. Fig. 16 **Travel characteristics on tandem actuators vary with actual basic switch characteristics. NOTE: Above actuators should be used below +300°F. See page 79 for other actuators that may be used with SM Switches at higher temperatures. †‘‘A’’ measurement is from the pivot point of lever to the point indicated on drawing. 30 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Subminiature SM Series MOUNTING DIMENSIONS (for reference only) PIN PLUNGER Fig. 1 Fig. 2 INTEGRAL LEVERS Fig. 8 Fig. 5 Fig. 9 Fig. 6 Fig. 7 Fig. 10 INTEGRAL LEAFS Mounting holes accept pins or screws of .087 inch (2,21 mm) max. diameter Fig. 11 Fig. 12 AUXILIARY ACTUATORS Fig. 14 Fig. 16 Switches are not included with the actuators. For application help: call 1-800-537-6945. Honeywell Sensing and Control 31 Miniature/ Subminiature Fig. 4 Position Sensors Environment-Sealed Basic Switches SE and XE Series GENERAL INFORMATION SE and XE switches are the smallest environment-sealed switches offered by MICRO SWITCH. Both types enclose basic switches within a corrosion resistant aluminum housing to seal precision switch contacts from contamination. SE switches include a SM basic switch, and XE switches include the smaller SX basic switch. Switches held depressed for extended periods of time at temperature extremes may experience retarded plunger return upon deactuation. Where such a condition exists in the application, contact the 800 number for special designs that are available. FEATURES 1 Watertight seal per enclosure design symbol 3, MIL-S-8805 1 Power load switching capability up to 7 amps 1 Temperature tolerance up to +221°F (105°C) 1 High temperature construction for use to +300°F (149°C) 1 Several auxiliary actuators 1 Choice of termination 1 Military standard construction with listings qualified to MIL-S-8805 1 All 4SE switches are UL recognized and CSA certified 1 4XE switches are UL recognized ELECTRICAL RATINGS Circuitry Electrical Rating Code Single-Pole Double-Throw A 5 amps res., 3 amps ind., (sea level), 5 amps res., 2.5 amps ind., (50,000 feet) 28 vdc. 5 amps res., 5 amps ind., 125 or 250 vac, 60 Hz. B UL and CSA Rating 5 amps, 250 vac, 60 Hz C 7 amps res., 4 amps ind., (sea level), 7 amps res., 2.5 amps ind., (50,000 feet), 28 vdc. 7 amps res., 4 amps ind., (sea level), 115 vac, 400 Hz 1 foot leads (other lengths available) Recommended For Electrical Rating Code O.F. Newtons ounces R.F. min. Newtons ounces Characteristics P.T. max. O.T. min. mm mm inches inches D.T. max. mm inches O.P. mm inches Most applications A 1,39-4,73 5-17 1,11 4 1,27 .050 0,08 .003 0,1 .004 10,8 .425 1SE2 SPST — Normallyclosed A 1,39-4,73 5-17 1,11 4 1,27 .050 0,08 .003 0,1 .004 10,8 .425 1SE3 SPST — Normallyopen A 1,39-4,73 5-17 1,11 4 1,27 .050 0,08 .003 0,1 .004 10,8 .425 4SE1 UL and CSA listing and UL and CSA listed lead wire Oil resistant Fluorosilicone seal B 1,39-4,73 5-17 1,11 4 1,27 .050 0,08 .003 0,1 .004 10,8 .425 A 1,39-4,73 5-17 1,11 4 1,27 .050 0,08 .003 0,1 .004 10,8 .425 7SE1 Lower force A 1,11-2,22 4-8 0,56 2 1,27 .050 0,08 .003 0,1 .004 10,8 .425 12SE4-T High return force A 1,39-5,28 5-19 1,11 4 1,27 .050 0,08 .003 0,1 .004 10,8 .425 1SE1-T For customer leading A 1,39-4,73 5-17 1,11 4 1,27 .050 0,08 .003 0,1 .004 10,8 .425 Fig. 2 Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada 13 Position Sensors 1SE1 5SE1 Fig. 1 E 7 amps res., 4 amps ind., (sea level), 7 amps res., 2.5 amps ind., (50,000 feet), 28 vdc. R 1 amp res., 0.50 amp ind., 28 vdc. Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Position SE SWITCHES ORDER GUIDE Catalog Listing D UL Rating 7 amps, 250 vac 60 Hz Position Sensors Environment-Sealed Basic Switches SE Series AUXILIARY ACTUATORS FOR SE SWITCHES ORDER GUIDE (Switches are not included with actuators) Catalog Listing Description Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Position Characteristics measured with actuators mounted to a 1SE1 Actuator O.F. R.F. P.T. O.T. D.T. Length A max. min. approx. min. max. O.P. mm Newtons Newtons mm mm mm mm inches ounces ounces inches inches inches inches F.P. mm inches JE-1 Straight leaf (mounting hardware included) 16,8 .66 3,34 12 0,56 2 3,81 .150 0,38 .015 0,64 .025 11,2 .440 15±0,76 .590±.030 JE-4 Roller leaf. Roller turned 90° to switch axis (mounting hardware included). 16,8 .66 3,34 12 0,56 2 3,81 .150 0,38 .015 0,64 .025 16,3 .640 20,1 .790 approx. JE-5 Roller leaf (mounting hardware included) 14,2 .560 3,34 12 0,56 2 3,81 .150 0,38 .015 0,64 .025 16,3 .640 20,1±0,76 .790±.030 JE-17 Roller leaf. Reversed position (mounting hardware included) 14,2 .560 3,34 12 0,56 2 3,81 .150 0,38 .015 0,64 .025 16,3 .640 20,1±0,76 .790±.030 JE-21 Roller lever 13,7 .540 1,67 6 0,28 1 2,54 .100 0,25 .010 0,41 .016 16,3 .640 18,8±0,76 .740±.030 JE-22 Tandem Roller Lever 17,8 .700 4,73 17 1,11 4 2,54 .100 0,15 .006 0,3 .012 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 16,8±1,3 19,3±1,3 .660±.050 .760±.050 Fig. 8 14 Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada Position Sensors Environment-Sealed Basic Switches XE Series Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; D.T. — Differential Travel; O.P. — Operating Position. XE SWITCHES ORDER GUIDE Characteristics Catalog Listing 1 foot leads (other lengths available) Recommended For Electrical Rating Code O.F. max. Newtons ounces R.F. max. Newtons ounces P.T. max. mm inches O.T. min. mm inches D.T. max. mm inches O.P. mm inches ±.020 (0,51) 1XE1 (MS27994-1) Most applications MIL-S-8805 requirements C 1,39-4,73 5-17 1,11 4 1,27 .050 0,1 .004 0,13 .005 10,8 .425 1XE201 (MS27994-4) General Use MIL-S-8805 requirements C 1,39-4,73 5-17 1,11 4 1,27 .050 0,1 .004 0,13 .005 10,8 .425 MIL-W-22759/11 wire 1XE3 SPST-Normally Open C 1,39-4,73 5-17 1,11 4 1,27 .050 0,1 .004 0,13 .005 10,8 .425 1XE301 (MS27994-5) Gold Contacts MIL-W-22759/11 wire R 1,39-4,73 5-17 1,11 4 1,27 .050 0,1 .004 0,13 .005 10,8 .425 4XE1 UL listing and UL and CSA listed leadwire D 1,39-4,73 5-17 1,11 4 1,27 .050 0,1 .004 0,13 .005 10,8 .425 5XE1 Oil resistant Fluorosilicone seal C 1,39-4,73 5-17 1,11 4 1,27 .050 0,1 .004 0,13 .005 10,8 .425 14XE1 Less operating force Use to +300°F (149°C) E 2,50 9 max. 0,56 2 0,76 .030 0,1 .004 0,13 .005 10,9 .430 14XE1-T For customer leading Use to +300°F (149°C) E 2,50 9 max. 0,56 2 0,76 .030 0,1 .004 0,13 .005 10,9 .430 1XE1-T (MS27994-3) For customer leading C 1,39-4,73 5-17 1,11 4 1,27 .050 0,1 .004 0,13 .005 10,8 .425 Fig. 9 Fig. 10 Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Position; F.P. — Free Position. AUXILIARY ACTUATORS FOR XE SWITCHES ORDER GUIDE (Switches are not included with the actuators) Characteristics measured with actuator mounted on a 1XE1 R.F. min. Newtons ounces P.T. approx. mm inches O.T. min. mm inches D.T. max. mm inches O.P. mm inches F.P. mm inches Catalog Listing Description JM-1 Straight leaf 5,84 21 0,83 3 3,18 .125 0,23 .009 0,3 .012 10,8±0,76 .425±.030 14±0,76 .550±.030 JM-5 Roller leaf 5,84 21 0,83 3 3,18 .125 0,23 .009 0,3 .012 15,9±0,89 .625±.035 19,1±0,89 .750±.035 Fig. 11 Fig. 12 Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada 15 Position Sensors O.F. max. Newtons ounces Position Sensors Environment-Sealed Basic Switches SE Series SE MOUNTING DIMENSIONS (For reference only) SE switches MOUNTING HOLES WILL ACCEPT PINS OR SCREWS OF 22,1/.087 MAX DIA Fig. 1 Fig. 2 SE auxiliary actuators Fig. 4 Fig. 5 Fig. 3 Fig. 8 Fig. 6 16 Fig. 7 Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada Position Sensors Environment-Sealed Basic Switches XE Series XE MOUNTING DIMENSIONS (For reference only) XE switches Fig. 9 Fig. 10 Fig. 11 Fig. 12 XE auxiliary actuators Position Sensors Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada 17 Position Sensors Hermetically Sealed Switches GENERAL INFORMATION HS switches are designed for applications where maximum electrical rating and maximum sealing are essential, and where size and weight requirements are less critical. These switches are side mounted through mounting holes that are outside the sealed switching chamber. HS Series FEATURES 1 Hermetically sealed per MIL-S-8805, design symbol 5 (–67° to +180°F or –55° to 82°C) 1 Power load switching capability up to 25 amperes, 28 VDC 1 Temperature tolerance from –67°F to +250°F (–55°C to +125°C) 1 High temperature construction for use to +300°F (149°C) 1 Several styles of integral lever actuators 1 Two styles of terminals 1 Military standard construction with listings on the MIL-S-8805 qualified products list 1 UL recognized File #E12252; CSA certified LR 4442 ELECTRICAL RATINGS Circuitry Single-Pole Double-Throw Electrical Rating Codes M 25 amps res., 8 amps ind., 5 amps motor, 3 amps lamp load, 28 vdc; 1 amp res., 1 amp ind., 115 vac, 60 Hz UL-CSA Rating: 1 amp., 115 vac, 60 Hz. N 15 amps res., 8 amps ind., 28 vdc; 1 amp res., 1 amp ind., 115 vac, 60 Hz O 20 amps res., 8 amps ind., 28 vdc; 1 amp res., 1 amp ind., 115 vac, 60 Hz UL-CSA Rating: 1 amp, 115 vac, 60 Hz P 22 10 amps res., 5 amps ind., 28 vdc; 1 amp res., 1 amp ind., 115 vac, 60 Hz UL-CSA Rating: 1 amp., 115 vac, 60 Hz. Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada Position Sensors Hermetically Sealed Switches HS Series Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Position. HS ORDER GUIDE Operating Characteristics Electrical O.F. max. R.F. min. P.T. max. O.T. min. D.T. max. Rating Newtons Newtons mm mm mm Code ounces ounces inches inches inches O.P. mm inches Catalog Listing Recommended For 1HS1 (MS25011-1) Most applications MIL-S-8805 (M8805/47) M 2,78-6,12 10-22 1,11 4 1,65 .065 0,25 .010 0,51 .020 13,5 ± 0,38 .530 ± .015 101HS1 Operating in temperatures to +250°F (121°C) O 2,78-6,12 10-22 1,11 4 1,65 .065 0,25 .010 0,51 .020 13,5 ± 0,38 .530 ± .015 102HS1 Operating in temperatures to +300°F (149°C) P 2,78-8,34 10-30 1,11 4 1,65 .065 0,25 .010 0,51 .020 13,5 ± 0,38 .530 ± .015 4HS4-118 Lead wire termination N 2,78-6,12 10-22 1,11 4 1,65 .065 0,25 .010 0,51 .020 15,6 .615± .020 1HS41 Applications requiring added overtravel M 1,11-5,56 4-20 0,56 2 — 1,57 .062 max. 2,54 .100 13,54 .533 approx. 1HS6 (MS25011-4) MIL-S-8805 requirements. More operating force M 6,12-7,78 22-28 1,11 4 2,16 .085 0,25 .010 0,51 .020 13,5 ± 0,38 .530 ± .015 1HS3 Roller lever M 2,78-6,12 10-22 1,11 4 1,65 .065 0,25 .010 0,51 .020 18,3 ± 0,38 .720 ± .015 Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 HS MOUNTING DIMENSIONS (For reference only) Fig. 1 Fig. 2 Fig. 4 Fig. 5 Position Sensors Mounting holes will accept pins or screws of .139N (3,53mm) diameter. Fig. 3 Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada 23 Position Sensors Miniature Hermetically Sealed Switches GENERAL INFORMATION HM switches are not generally recommended for 115 VAC, 60 Hz. If you have a 60 Hz application in the milliamp range, contact our 800 number for special design variations that are available. HM Series FEATURES 1 Hermetically sealed per enclosure design symbol 5, MIL-S-8805 1 Power load switching capability up to 4 amperes, 28 VDC and 2 Amps 115 VAC, 400 Hz 1 Temperature tolerance from –85°F to +250°F (–65°C to +121°C) 1 High temperature construction for use from –85°F to +500°F (–65°C to +260°C) 1 Variety of auxiliary actuators 1 Choice of terminal styles 1 Gold contacts for special applications 1 Military standard construction with listings on the MIL-S-8805 qualified products list. ELECTRICAL RATINGS Circuitry Electrical Rating Code Single-Pole Double-Throw H 1 amp res., 0.25 amp ind., 28 VDC. Single-Pole Double-Throw I 2 amps res., 2 amps ind., 0.5 amps lamp load, 115 VAC, 400 Hz. 4 amps res., 2 amps ind., 1 amp lamp load, 28 VDC Single-Pole Double-Throw J 1 Single-Pole Double-Throw K 3 amps res., 1 amp ind. (sea level or 70,000 ft.), 28 VDC 1 amp res. or ind. (sea level), 115 VAC., 400 Hz. Single-Pole Double-Throw L 3 amp res., 1 amp ind., 28 VDC 1 amp res., 1 amp ind., 115 VAC, 400 Hz. ⁄2 amp res., 1⁄4 amp ind. (sea level or 70,000 ft.), 28 VDC APPLICATION NOTES 1. Honeywell does not recommend the use of silver cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally loads less than 12 volts and/or 0.5 amp. Catalog listings in the 5, 6, 15, and 16HM Series use silver cadmium oxide contacts. If you have specific questions, contact the MICRO SWITCH Application Center at 1-800-537-6945. 2. For applications involving non-arcing loads, catalog listings in the 9, 10, 19 and 20HM Series are recommended. 3. The 1, 2, 5, and 6HM Series are recommended for use only in 3 to 4 amp range applications. 18 Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada Position Sensors Miniature Hermetically Sealed Switches HM Series Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Position. HM ORDER GUIDE Operating Characteristics Catalog Listing Recommended For Electrical Rating Code O.F. max. R.F. min. Newtons Newtons ounces ounces P.T. max. mm inches O.P. O.T. min. D.T. max. mm mm mm inches inches inches ±.015 (0,38 mm) 11HM1 (MS27216-5) Most applications. Exceeds MIL-S-8805 requirements for shock and vibration. K 1,95 7 0,28 1 0,76 .030 0,08 .003 0,15 .006 8,38 .330 13HM1 Applications requiring gold contacts H 1,95 7 0,28 1 0,76 .030 0,08 .003 0,15 .006 8,38 .330 9HM1 (MS27216-6) Bifurcated gold contacts J 1,95 7 0,28 1 0,76 .030 0,08 .003 0,15 .006 8,38 .330 2HM19-1 (MS27216-2) MIL-S-8805 application requirements 1 ft. (305mm) leads I 1,95 7 0,28 1 0,76 .030 0,08 .003 0,15 .006 8,38 .330 2HM19-5 (MS27216-4) 5 foot (1524mm) long leads I 1,95 7 0,28 1 0,76 .030 0,08 .003 0,15 .006 8,38 .330 16HM1-1 High temperature to 500°F (260°C) flat spring L 1,95 7 0,28 1 0,76 .030 0,08 .003 0,15 .006 8,38 .330 15HM2 Operating in temperatures to +500°F (260°C) with weld tab termination. L 1,95 7 0,28 1 0,76 .030 0,08 .003 0,15 .006 8,38 .330 Fig. 1 Fig. 2 Fig. 3 Position Sensors Fig. 4 HM MOUNTING A force spreading plate is recommended to reduce the chance of product damage due to excessive mounting force. MOUNTING PLATE 19PA137-HM NOTICE Torque on #2 mounting screws must be restricted to 1.5 inch pounds max. to prevent switch damage. The force spreading mounting plate used as shown will allow up to 2.5 inch pounds of mounting torque. Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada 19 Position Sensors Miniature Hermetically Sealed Switches HM Series Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Position; F.P. — Free Position. AUXILIARY ACTUATORS FOR HM SWITCHES ORDER GUIDE (Switches are not included) Operating Characteristics with Actuator Mounted on a 6HM1-1 Catalog Listing Description JS-254 Leaf Temp. (Max.) O.F. max. R.F. min. Newtons Newtons ounces ounces P.T. max. mm inches O.T. min. D.T. max. mm mm inches inches O.P. mm inches F.P. mm inches 500°F (260°C) 2,50 9 0,56 2 — 0,76 .030 0,76 .030 8,64 12,2 .340 approx. .480 approx. 500°F (260°C) 2,50 9 0,56 2 — 0,76 .030 0,76 .030 14 17,5 .550 approx. .690 approx. JS-307 Straight lever 500°F (260°C) 0,42 1.5 0,03 .11 3,18 .125 approx. 0,64 .025 1,42 .056 10,3 .406 approx. JS-308 Roller lever 0,42 1.5 0,03 .11 3,18 .125 approx. 0,64 .025 1,42 .056 14,3 .562 approx. Fig. 5 JS-151 Roller leaf Fig. 6 Fig. 7 500°F (260°C) Fig. 8 MOUNTING TORQUE: JS-254 2.5 inch pounds all others 1.5 inch pounds See optional mounting plate – previous page. 20 All standard JS actuators in the SM Section of Catalog 10 can be used with the HM line. However, hardware, insulator, and oil impregnated roller supplied with these actuators may not provide the required service at temperatures above 250°F (121°C). Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada Position Sensors Miniature Hermetically Sealed Switches HM Series HM MOUNTING DIMENSIONS (For reference only) Pin plunger switches Fig. 1 Fig. 2 MOUNTING HOLES WILL ACCEPT PINS OR SCREWS OF 1,9/.08 DIA Fig. 4 Fig. 3 Auxiliary actuators Position Sensors Fig. 5 Fig. 6 Fig. 8 Fig. 7 Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada 21 Position Sensors High Temperature Basic Switches HT Series GENERAL INFORMATION HT switches will withstand temperatures up to +1000F. The switching element is mounted on a ceramic base within a stainless steel enclosure. HT switches are not classified as sealed switches. FEATURES 1 Temperature tolerance up to +1000°F (538°C) 1 Designed to meet military applications 1 Side and panel mount 1 UL recognized ELECTRICAL RATINGS Circuitry Single-Pole Double-Throw Electrical Rating UL Ratings: 3 amps, 1/10 HP, 125 vac. 3 amps, 1/6 HP, 250 vac. Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; O.P. – Operating Position HT ORDER GUIDE Catalog Listing Description O.F. newtons ounces R.F. min. newtons ounces P.T. max. mm inches O.T. min. mm inches O.P. mm inches 1HT1 Straight plunger panel mount 2,78-5,56 10-20 1,67 6 1,65 .065 4,78 .188 23,7 .935 approx. 3HT1 Roller plunger panel mount 8,34 30 max. 1,67 6 1,65 .065 4,78 .188 35,9 1.413 approx. 2HT1 Pin plunger side mount 2,78-5,56 10-20 1,67 6 1,27 .050 0,25 .010 16,8 .66 approx. Fig. 1 Fig. 2 Fig. 3 HT MOUNTING DIMENSIONS (For reference only) Fig. 1 Mounting holes will accept pins or screws of .139N (3,53 mm) dia. 24 Fig. 2 Fig. 3 Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada MT Series FEATURES 1 Arc resistant case 1 Mechanical life of 100,000 operations — 95% survival 1 Temperature tolerance to +180°F (82°C) 1 Mounting interchangeability with Z switches 1 UL recognized GENERAL INFORMATION MT (single-pole double-throw) magnetic blow-out switches are designed to switch high capacity (125 and 250 VDC) systems. An integral magnet around the contact gap protects the contacts by deflecting the arc. Vents between the cover and housing allow the hot gas to escape. These switches are designed for the control of DC motors, solenoids, etc. AVAILABLE TERMINALS Solder (No listing designation) A28 6-32NC H .218N Screws will accept up to #12 wire. ELECTRICAL RATING Electrical Data and UL Codes Circuitry Single-pole double-throw unless otherwise noted in order guide K Rating established with switch non-polarized 10 amps, 125 vac or vdc; 1/4 hp, 125 vac or vdc. UL Code L 168 Non-polarized: 10 amps res. or 1/4 hp, 125 vdc; 3 amps max. res. 250 vdc. Polarized*: 10 amps res. or 1/2 hp, 125 vdc; 3 amps max. res., 250 vdc. *To polarize, connect negative side of line to common terminal. To achieve the same effect, mount switch with brass screws, using a non-magnetic barrier (at least 1⁄4 N thick) between the switch and mounting surface. Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating Position. ORDER GUIDE Catalog Listing MT-4R-A28 Recommended For Pin plunger SPDT Electrical Data and UL Codes O.F. newtons ounces R.F. min. newtons ounces P.T. max. mm inches O.T. min. mm inches D.T. max. mm inches O.P. mm inches 10 Amps K 3,34-5,0 12-18 1,39 5 1,02 .04 0,13 .005 0,1-0,18 .004-.007 15,9±0,38 .625±.015 Dim. Dwg. Fig. 1 70 Honeywell Sensing and Control For application help: call 1-800-537-6945. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Basic Switches Magnetic Blow-out MT Series ORDER GUIDE Catalog Listing Description Electrical O.F. max. Data and newtons UL Codes ounces R.F. min. newtons ounces P.T. max. mm inches O.T. min. mm inches D.T. max. mm inches O.P.* mm inches MT-4RV-A28 Straight lever 10 Amps K 0,56 2 0,14 0.5 12,7 0.5 1,19 .047 2,16 .085 19,1 .750 MT-4RV2-A28 1.90 inch (48,3mm) lever with hardened steel roller 10 Amps K 0,76 2.75 0,07 0.25 8,89 0.35 0,79 .031 1,65 .065 30,2 1.188 MT-4RV22-A28 1.03 inch (26,2mm) lever with hardened steel roller 10 Amps K 1,25 4.5 0,28 1 5,08 .200 0,38 .015 0,89 .035 31,3 1.234 MT-4RL-A28 1.95 inch (49,5mm) flexible leaf 10 Amps K 3,34 12 0,28 1 — 1,52 .060 max. — 19,1 .750 1.82 inch (46,2mm) flexible leaf with hardened steel roller 10 Amps K 3,34 12 0,28 1 — 1,52 .060 max. — 30,2 1.188 Dim. Dwg. Fig. 2 Dim. Dwg. Fig. 3 Dim. Dwg. Fig. 4 Dim. Dwg. Fig. 5 For application help: call 1-800-537-6945. Except where stated * ±0,76 mm ±.030 in. Honeywell Sensing and Control 71 Standard Basic Switches MT-4RL2-A28 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Basic Switches Magnetic Blow-out MT Series MOUNTING DIMENSIONS (For reference only) PIN PLUNGER STRAIGHT LEVER Fig. 1 Fig. 2 ROLLER LEVER FLEXIBLE LEAF Fig. 3 Fig. 4 FLEXIBLE ROLLER LEAF Fig. 5 Mounting holes accept pins or screws of .139 N (3,53 mm) diameter. 72 Honeywell Sensing and Control For application help: call 1-800-537-6945. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Basic Switches Magnetic Blow-out Obsolete V3 Series CUT-A-WAY V3 MINIATURE BASIC SWITCH GENERAL INFORMATION V3 miniature basic switches feature high electrical capacity and long life. Their size and shape meet design requirements in all types of applications. There is a choice of SPDT, SPNC, and SPNO circuitry. Many lever styles, contact materials, and terminal variations can be furnished. Contact the 800 number for ordering information. FEATURES 1 Low operating force to .53 ounce maximum 1 Sensitive differential travel as low as .006 inch maximum 1 Power load switching capability up to 25 amperes–silver contacts 1 Gold alloy crosspoint, silver cadmium, and other contact material for special applications 1 Long mechanical life of 10,000,000 cycles—95% survival for V3-100, V3-1100, V3-2100, V3-3000 Series 1 Temperature tolerance up to +180°F (82°C) on standard construction 1 High temperature construction for use up to +600°F (316°C) 1 3,1 mm mounting holes available 1 UL recognized File #E12252, CSA certified File #LR41370 AVAILABLE TERMINALS SOLDER D8 SHORT SOLDER QUICK CONNECT SCREW D9 Dimensions shown are for reference only .188 wide × .020 thick terminals .250 wide × .032 thick terminals Mounting torque: 2 inch pounds min. 5 inch pounds max. This section covers only 60 of our most popular V3 Series catalog listings. If you don’t find what you’re looking for, it’s likely one of the approximately 850 other active V3 listings will meet your needs. Contact the 800 number. 32 Honeywell 1 MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Basic Switches Miniature Obsolete PIN PLUNGERS V3 Series Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating Position. ORDER GUIDE by ascending electrical capability Catalog Listing Dim. Dwg. Fig. 1 Recommended For R.F. O.F. min. newtons newtons ounces ounces P.T. max. mm inches O.T. min. mm inches D.T. mm inches O.P.** mm inches V3-343-D8 General use. Gold alloy crosspoint contacts. 1 Amp X 2,22 8 max. 0,56 2 1,2 .047 1,02 .040 0,15-0,41 .006-.016 14,7 .578 V3-2451-D8 Lowest force. 3 Amps VV 0,15 .53 — 1,2 .047 1,27 .050 0,051-0,25 .002-.010 14,7 .578 V3-2401-D8 Lower force. 5 Amps YY 0,24 .9 — 1,2 .047 1,27 .050 0,051-0,25 .002-.010 14,7 .578 V3-70101-D8 Most 5 amp applications. 5 Amps ZZ 2,22 8 0,56 2 1,2 .047 1,02 .040 0,15-0,41 .006-.016 14,7 .578 V3-1101-D8 General use. 10 Amps TT 0,72 max. 2.6 0,10 .35 1,2 .047 1,27 .050 0,051-0,25 .002-.010 14,7 .578 V3-2101-D8 Low force. 10 Amps V 0,50 max. 1.8 0,05 .18 1,2 .047 1,27 .050 0,051-0,25 .002-.010 14,7 .578 V3-101-D8 Higher force. Most applications. 11 Amps T 2,22 8 max. 0,56 2 1,2 .047 1,02 .040 0,15-0,41 .006-.016 14,7 .578 V3-1-D8 Highest force. Up to 15.1 amps load handling with reduced life. 15.1 Amps U 1,67-3,89 6-14 1,11 4 1,21 .047 1,0 .040 0,15-0,4 .006-.016 14,7 .578 V3-3001-D8 High force. Up to 15.1 amps load handling. 15,1 Amps U 1,47 max. 5.3 0,15 .53 1,2 .047 1,27 .050 0,051-0,25 .002-.010 14,7 .578 V3-2800-D9 Up to 20 amps load handling 20 Amps AA 0,63 - 1,22 2.3 - 4.4 0,20 0.7 1,2 .047 1,27 .050 0,25 .010 max. 14,7 .578 V3-2900-D9 Up to 25 amps load handling 25 Amps BB 1,22 - 2,20 4.4 - 7.9 0,31 1.1 1,2 .047 1,27 .050 0,25 .010 max 14,7 .578 V3-1001 (MS25253-1) MIL-S-8805 application requirements (SPDT) 10 Amps UU 1,67-3,89 6-14 1,11 4 1,2 .047 1,02 .040 0,15-0,41 .006-.016 14,7 .578 V3-1002 (MS25253-3) MIL-S-8805 application requirements (SPNC) 10 Amps UU 1,67-3,89 6-14 1,11 4 1,2 .047 1,02 .040 0,15-0,41 .006-.016 14,7 .578 V3-1003 (MS25253-2) MIL-S-8805 application requirements (SPNO) 10 Amps UU 1,67-3,89 6-14 1,11 4 1,2 .047 1,02 .040 0,15-0,41 .006-.016 14,7 .578 V3-129* Operating in temperature to +302°F (150°C) 11 Amps T 2,22 8 max. 0,56 2 1,2 .047 1,02 .040 0,15-0,41 .006-.016 14,7 .578 V3-245* Operating in temperature to +400°F (204°C) 10 Amps W 2,78-6,95 10-25 1,67 6 1,2 .047 1,02 .040 0,15-0,41 .006-.016 14,7 .578 Miniature/ Subminiature Dim. Dwg. Fig. 2 Electrical Data And UL Code Page 20 **Tolerances ±0.38 ±0.15 *For actuators, contact MICRO SWITCH Sales Office. ORDER GUIDE SIMULATED ROLLER Catalog Listing Electrical Length of O.F. R.F. P.T. Data And Lever ‘‘A’’ max. min. max. mm newtons newtons mm UL Code Recommended For Page 20 inches ounces ounces inches O.T. min. mm inches D.T. max. mm inches O.P.* mm inches V3L-1123-D8 General use. 10 Amps TT 32,6 1.285 0,39 1.4 0,05 .18 2,54 .100 2,03 .080 0,76 .030 18,5 .730 V3L-2105-D8 Low force. 10 Amps V 32,6 1.285 0,33 1.2 0,02 .07 2,54 .100 2,03 .080 0,76 .030 18,5 .730 V3L-121-D8 High force. Most applications. 11 Amps T 32,6 1.285 1,11 4 0,14 .5 3,18 .125 1,57 .062 0,81 .032 18,5 .730 V3L-5-D8 Highest force. Up to 15.1 amps load handling with reduced life. 15.1 Amps U 32,6 1.285 2,22 8 0,28 1 3,18 .125 1,57 .062 0,81 .032 18,5 .730 V3L-3014-D8 High force. Up to 15.1 amps load handling. 15.1 Amps U 32,6 1.285 0,94 3.4 0,07 .25 2,54 .100 1,90 .075 0,76 .030 18,5 .730 Dim. Dwg. Fig. 3 *±1.5 mm ±.060 in. For application help: call 1-800-537-6945. Honeywell 1 MICRO SWITCH Sensing and Control 33 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Basic Switches Miniature Obsolete V3 Series ORDER GUIDE STRAIGHT LEVERS Catalog Listing Dim. Dwg. Fig. 4 Dim. Dwg. Fig. 4 Dim. Dwg. Fig. 4 Dim. Dwg. Fig. 4 34 Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating Position. Electrical Length of O.F. R.F. P.T. O.T. D.T. min. max. min. max. Data And Lever ‘‘A’’ max. UL Code mm newtons newtons mm mm mm Recommended For Page 20 inches ounces ounces inches inches inches O.P. mm inches V3L-1105-D8 General use. 10 Amps TT 21,3 .860 0,72 2.6 0,10 .35 1,5 .060 1,14 .045 0,33 .013 15,2±0,51 .600±.020 V3L-2101-D8 Low force. Added overtravel. 10 Amps V 21,3 .860 0,50 1.8 0,50 .18 1,5 .060 1,14 .045 0,33 .013 15,2±0,51 .600±.020 V3L-101-D8 Higher force. Most applications. 11 Amps T 21,3 .860 2,50 9 0,56 2 1,5 .060 1,02 .040 0,41 .016 15,2±0,51 .600±.020 V3L-1-D8 Highest force. Up to 15.1 amps load handling with reduced life. 15.1 Amps U 21,3 .860 3,89 14 0,83 3 1,5 .060 1,02 .040 0,41 .016 15,2±0,51 .600±.020 V3L-3001-D8 High force. Up to 15.1 amps load handling. 15.1 Amps U 21,3 .860 1,47 5.3 0,15 .53 1,5 .060 1,02 .040 0,28 .011 15,2±0,51 .600±.020 V3L-1108-D8 General use. 10 Amps TT 35,6 1.40 0,39 1.4 0,04 .14 2,79 .110 2,29 .090 0,76 .030 15,2±1,5 .600±.060 V3L-2102-D8 Low force. 10 Amps V 35,6 1.40 0,31 1.1 0,02 .07 2,79 .110 2,29 .090 0,76 .030 15,2±1,5 .600±.060 V3L-104-D8 Higher force. Most applications. 11 Amps T 35,6 1.40 1,11 4 0,14 .5 3,18 .125 2,29 .090 1,27 .050 15,2±1,5 .600±.060 V3L-2-D8 Highest force. Up to 15.1 amps load handling with reduced life. 15.1 Amps U 35,6 1.40 2,22 8 0,28 1 3,18 .125 2,29 .090 1,27 .050 15,2±1,5 .600±.060 V3L-3005-D8 High force. Up to 15.1 amps load handling. 15.1 Amps U 35,6 1.40 .86 3.1 0,06 .21 3,05 .120 2,29 .090 0,81 .032 15,2±1,5 .600±.060 V3L-2425-D8 Lower force. 5 Amps YY 59,4 2.34 0,07 .25 — 5,08 .200 4,06 .160 1,4 .055 15,2±2 .600±.080 V3L-1122-D8 General use. 10 Amps TT 59,4 2.34 0,22 .81 0,02 .07 5,08 .200 4,06 .160 1,4 .055 15,2±1,8 .600±.070 V3L-2106-D8 Low force. 10 Amps V 59,4 2.34 0,16 .56 0,01 .04 5,08 .200 4,06 .160 1,4 .055 15,2±1,8 .600±.070 V3L-131-D8 Higher force. Most applications. 11 Amps T 59,4 2.34 0,58 2.1 0,12 .42 6,6 .260 3,81 .150 2,29 .090 14,7±2 .580±.080 V3L-6-D8 Highest force. Up to 15.1 amps load handling with reduced life. 15.1 Amps U 59,4 2.34 1,11 4 0,14 .50 6,95 2.60 3,81 .150 2,29 .090 14,35±1,5 .565±.060 V3L-3013-D8 High force. Up to 15.1 amps load handling. 15.1 Amps U 59,4 2.34 0,39 1.4 0,03 .11 5,33 .210 4,06 .160 1,52 .060 15,2±1,9 .600±.075 V3L-2472-D8 Lowest force. 3 Amps VV 69,45 2.75 0,03 .11 — — 5,97 .235 5,08 .200 1,60 .063 15,2±2,54 .600±.100 V3L-1124-D8 General use. 10 Amps TT 69,45 2.75 0,19 .70 0,01 .04 7,74 .305 3,68 .145 1,65 .065 15,31±2,54 .603±.100 V3L-145-D8 Most applications. 11 Amps T 69,45 2.75 0,54 1.93 0,10 .36 0,76 .300 4,57 .180 2,54 .100 14,48±2,03 .570±.080 V3L-14-D8 Highest force. Up to 15.1 amps load handling with reduced life. 15.1 Amps U 69,45 2.75 0,83 3 0,14 .50 8,38 .330 4,32 .170 2,54 .100 13,72±2,03 .540±.080 Honeywell 1 MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Basic Switches Miniature Obsolete V3 Series ORDER GUIDE ROLLER LEVERS Catalog Listing Recommended For Electrical Length of Data And Lever ‘‘A’’ UL Codes mm Page 20 inches O.F. max. newtons ounces R.F. min. newtons ounces P.T. max. mm inches O.T. min. mm inches D.T. max. mm inches O.P. mm inches General use. 10 Amps TT 20,6 .81 0,89 3.2 0,10 .35 1,2 .047 1,14 .045 0,33 .013 20,6±0,76 .810±.030 V3L-2103-D8 Low force. 10 Amps V 20,6 .81 0,58 2.1 0,03 .11 1,42 .056 0,86 .034 0,33 .013 20,6±0,76 .810±.030 V3L-139-D8 Higher force. Most applications. 11 Amps T 20,6 .81 2,22 8 0,56 2 1,5 .060 1,02 .040 0,41 .016 20,6±0,76 .810±.030 V3L-3-D8 Highest force. 15.1 Amps Up to 15.1 amps U load handling with reduced life. 20,6 .81 3,89 14 0,83 3 1,52 .060 1,02 .040 0,41 .016 20,6±0,76 .810±.030 V3L-3003-D8 High force. Up to 15.1 amps load handling. 15.1 Amps U 20,6 .81 1,89 6.8 0,15 .53 1,2 .047 1,02 .040 0,05 - 0,25 .002 - .010 20,6±0,76 .810±.030 V3L-1101-D8 General use. 10 Amps TT 34 1.34 0,44 1.6 0,04 .14 3,18 .125 2,16 .085 0,76 .030 20,6±1,5 .810±.060 V3L-2104-D8 Low force. 10 Amps V 34 1.34 0,31 1.1 0,02 .07 3,18 .125 2,16 .085 0,76 .030 20,6±1,5 .810±.060 V3L-111-D8 Higher force. Most applications. 11 Amps T 34 1.34 1,11 4 0,14 .5 3,18 .125 2,16 .085 1,27 .050 20,6±1,5 .810±.060 V3L-4-D8 Highest force. 15.1 Amps Up to 15.1 amps U load handling with reduced life. 34 1.34 2,22 8 0,28 1 3,18 .125 2,16 .085 1,27 .050 20,6±1,5 .810±.060 V3L-3004-D8 Higher force. Up to 15.1 amps load handling. 34 1.34 0,89 3.2 0,14 .5 3,18 .125 2,16 .085 0,76 .030 20,6±1,5 .810±.060 Dim. Dwg. Fig. 7 Dim. Dwg. Fig. 7 15.1 Amps U Characteristics: O.F. — Operating Force; O.T. — Overtravel; D.T. — Differential Travel; R.F. — Release Force; P.T. — Pretravel; O.P. — Operating Position; F.P. — Free Position. * Characteristics taken with actuator assembled on Catalog Listing V3-1 switch as shown. AUXILIARY ACTUATORS ORDER GUIDE - SWITCHES ARE NOT INCLUDED WITH ACTUATORS Catalog Listing Description Actuator Length ‘‘A’’ O.F. max mm newtons inches ounces R.F. min. newtons ounces P.T. max. mm inches O.T. min. mm inches D.T. max. mm inches O.P. mm inches F.P. max. mm inches JV-1 Leaf type 21,3 .84 3,34 12 1,11 4 1,19 .047 0,79 .031 0,41 .016 15±0,38 .590±.015 16,4 .645 JV-7 Long leaf 32,3 1.27 2,50 9 1,11 4 1,57 .062 1,27 .050 0,64 .025 14,5±0,76 .570±.030 17,4 .685 JV-5 Roller leaf 20,6 .81 3,34 12 1,11 4 1,52 .060 0,79 .031 0,41 .016 20,3±0,64 .800±.025 22,1 .870 Dim. Dwg. Fig. 11 Dim. Dwg. Fig. 11 Dim. Dwg. Fig. 11 NOTE: Contact a MICRO SWITCH Sales Office for application assistance when actuators will be used at temperatures above 300°F (149°C). For application help: call 1-800-537-6945. Honeywell 1 MICRO SWITCH Sensing and Control 35 Miniature/ Subminiature V3L-1117-D8 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Basic Switches Miniature Obsolete V3 Series Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Positon; F.P. — Free Position * Characteristics taken with actuator assembled on Catalog Listing V3100 switch as shown. AUXILIARY ACTUATORS Switches are not included with actuators ORDER GUIDE - SWITCHES ARE NOT INCLUDED WITH ACTUATORS Catalog Listing Description Actuator Length ‘‘A’’ O.F. max. mm newtons inches ounces R.F. min. newtons ounces P.T. max. mm inches O.T. min. mm inches D.T. max. mm inches O.P. mm inches F.P. max. mm inches JV-26 Long lever 44,5 † 1.75 0,39 1.4 0,06 .21 8,33 .328 3,58 .141 4,75 .187 12,7±3,18 .500±.125 — JV-20 Roller lever 19,1 † .750 0,83 3 0,14 .5 4,78 .188 1,57 .062 1,98 .078 19,5±1,4 .766±.055 23,8 .936 JV-220 Roller lever 17,7 † .695 0,83 3 0,14 .5 4,78 .188 1,57 .062 1,98 .078 19,5±1,1 .766±.045 23,8 .936 JV-30 One-way roller lever 20,6 .81 3,34 12 1,11 4 2,03 .080 0,51 .020 0,38 .015 25,7±0,76 1.010±.030 27,7 1.09 JV-91** Tandem leaf 20,6 .81 5,00 18 1,67 6 1,57 .062 0,89 .035 – 14,9±0,76 .588±.030 16,5 .650 JV-82** Tandem roller leaf 20,6 .81 5,00 18 1,67 6 1,57 .062 0,89 .035 – 20,5±0,76 .806±.030 21,8 .860 Dim. Dwg. Fig. 14 Dim. Dwg. Fig. 14 Dim. Dwg. Fig. 14 Dim. Dwg. Fig. 11 Dim. Dwg. Fig. 17 NOTE: Contact the 800 number for application assistance when actuators will be used at temperatures above 300°F (149°C). ** Travel characteristics on tandem actuators vary with actual basic switch characteristics. These shown are typical for the assembly. † ‘‘A’’ measurement is from the pivot point of lever to the point indicated on drawing. Dim. Dwg. Fig. 17 36 Honeywell 1 MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945. Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Basic Switches Miniature Obsolete V3 Series MOUNTING DIMENSIONS (for reference only) PIN PLUNGERS Fig. 1 SIMULATED ROLLER Fig. 2 STRAIGHT LEVER ROLLER LEVER Miniature/ Subminiature Fig. 3 Fig. 4 Fig. 7 AUXILIARY ACTUATORS Fig. 11 Fig. 14 NOTE: Operate point dimensions taken at top of lever/roller. Fig. 17 For application help: call 1-800-537-6945. Honeywell 1 MICRO SWITCH Sensing and Control 37 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Basic Switches Miniature BASIC SWITCHES V5 Series Miniature Basic Switches V5 Series Basic Switches are used for simple or precision on/off, end of limit, presence/absence, pressure, temperature and manual operato r interface application needs . Voltage : 250 Vac Operating temperature : Standard -55 °C to 85 ° C -67 °F to 185 ° F High temperature -55 °C to 150 ° C -67 °F to 302 ° F Termination : 6,3 mm x 0,8 mm Quick connect (QC ) Contact type : Silver/silver cadmium oxid e Electrical rating : V5 A 20 A V5B/P/ R 16 A V5C/ D 10 A 22 A V5S Switching options : SPDT Single Pole Double Throw Straight /ever Typ e 20, 6 1, 6 (P .T .) 22 A 20, 6 (O .P. ) 15, 3 (O .P.) APPROVALS CE, CSA, ENEC, U L REFERENCE V5CO10BB3B REFERENCE V5B210CB3 D V5C010BB3 D H TI 3, 2 (P.T .) 3 .2 34 (T h 35,6 a 20 .6 (O .P .) 15, 3 (O .P .) OPTIONS High temperature Type E Type C PI APPROVALS CE, CSA, ENEC. UL CE, CSA . ENEC. UL Top pin plunger APPROVAL S CE, ENE C High temperature REFERENC E V5B210CB1 C 59, 5 s.1 ► APPROVALS CE ENEC CE, CSA, ENEC, UL CE, CSA, UL CE, ENEC CE, ENEC CE, ENEC CE, CSA . ENEC . UL CE, CSA . ENEC . UL CE, ENEC APPROVALS CE ENEC CE . ENEC CE, BEAB CE, BEAB -14,1-, 4,8 mm x 0,5 mm OC Solder terminals High temperature 4,8 mm x 0,5 mm OC Solder terminals SWITCHING OPTIONS SPNO SPNO SPNC SPNO REFERENC E V5A010C B V5BO10C8 3 V5BO10FB3 V5BO10T 0 V5B210C B V5CO10B B V5C010EB 3 V5CO10TB 3 V5PO10CB Lever position 2 High temperature REFERENC E V5A010CB4 E V5B210CB1 E I Type ►i2,8r APPROVALS CE. CSA, ENEC . UL CE. ENEC APPROVAL S CE, ENEC REFERENC E V5CO10BB1 G REFERENC E V5DO30B B V5R030C B V5S020C B V5SO30CB Honeywel l www .honeywell .com/sensing Basic Switches Miniature V7 Series CUTAWAY V7 MINIATURE BASIC SWITCH FEATURES 1 Quick-connect and printed wiring board termination 1 Proven V3 switching mechanism 1 Physically interchangeable with existing V3 switches 1 All existing V3 lever options available 1 UL recognized File # E12252; CSA certified File # LR41370 1 International listings carry VDE approval 1 Power load switching capability up to 21 amps 1 Temperature tolerance –40° to 185°F (–40° to 85°C) 1 High temperature construction available—350°F APPLICABLE EUROPEAN SYMBOLS µ = microgap construction. (The measurement between open contacts is less than 3mm).** ` = alternating current (used with value of voltage source: 250V `). T = maximum rated use temperature; followed by the temperature value in °C (example T 85). +++ = switch is rated for at least 50,000 cycles at its rated current. (Sometimes referred to as ‘‘frequent’’ operation.) 10(3) = first number represents resistive rating. Second number represents inductive (motor) rating. GENERAL INFORMATION The V7 Series is available in two versions, the Timesaver series and the International series. The Timesaver series is UL recognized and CSA certified. Timesaver series switches use readily available high-volume components to provide especially responsive delivery performance. The International V7 provides VDE approval in addition to UL recognition and CSA certification. The V7 offers a choice of four quick-connect and two printed wiring board terminal types. Three quick-connect types are offset to meet international 3mm spacing requirements and one is designed for use with molded connectors. Contact material choice includes gold alloy, silver alloy or silver for handling various electrical loads. There are two mounting hole sizes available. Standard .114N or 3mm to meet European design requirements. dard receptacles and connectors. The plastic enclosure meets VDE KC250 arc tracking requirement and is approvable under the Refrigeration Industry Taste and Odor test. OPERATING FORCES 175 grams (V rating only) 150 grams (Not applicable to Electrical Rating V) 75 grams (Not applicable to Electrical Rating C or V) 50 grams (Not applicable to Electrical Rating B, C, V) 25 grams (Not applicable to Electrical Rating B, C, E, V) 15 grams (Not applicable to Electrical Rating A, B, C, E, S, V) Mounting Torque: 2 inch pounds min. 5 inch pounds max. Terminal variations and switch dimensions of the European designed version conform to applicable DIN standards. These V7s mate with both standard domestic and international industry stan- ELECTRICAL RATINGS A 5 amps, 125, 250 or 277 VAC; 1⁄10 hp, 250 VAC W 15.1 amps, 125, 250 or 277 VAC B 11 amps and 1⁄3 hp, 125, 250 or 277 VAC; 1⁄2 amp, 125 VDC; 1 ⁄4 amp, 250 VDC; 4 amps, 125 VAC ‘‘L’’ C* 15.1 amps and 1 ⁄2 hp, 125, 250 or 277 VAC; 1⁄2 amp, 125 VDC; 1 ⁄4 amp, 250 VDC; 5 amps, 120 VAC ‘‘L’’ D 1 amp, 125 VAC E 10 amps and 1⁄3 hp 125 or 250 VAC; 1⁄2 amp, 125 VDC; 1⁄4 amp, 250 VDC; 4 amps, 125 VAC ‘‘L’’ F 3 amps, 125, 250 or 277 VAC; 1⁄10 hp, 250 VAC S V .1 amp, 125 VAC 21 amps 125, 250 or 277 VAC, 1 HP 125, 250, 277 VAC; 2 HP, 250, 277 VAC +++ 16 (4) 250V ` µ T 85 50E3 SPNO only X 6 amps; 1⁄8 HP 125, 250 or 277 VAC International Series Only 10 (3) +++ 250V ` µ T 85 5 (2) +++ 250V ` µ T 85 * Available only when specifying 150 gram operating force. NOTE: ‘‘L’’ denotes lamp load. **The microgap construction (M) means contact gap is less than 3mm. Therefore, these products are suitable for secondary circuit use but not primary circuit use which requires a 3mm gap. 38 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Miniature V7 Series AVAILABLE TERMINALS Quick-connect D8* .187 Wide H .020 Thick NOTE: D8 and E8 terminals are European approved when used with electrical ratings B, D, or E. E9 terminals are European approved when used with electrical ratings B, C, D, or E. Printed Wiring Board E8 .187 Wide H .020 Thick E9 .250 Wide H .032 Thick * International approving agencies will require that switches with these terminals have insulated receptacles or connector. PO1 Miniature/ Subminiature Printed wiring board terminals interface with snap-on receptacles and other components from AMPMODU interconnection system. Dimensions shown are for reference only. PO2 PO7 This section covers only 48 of our most popular V7 Series catalog listings. If you don’t find what you’re looking for, it’s likely one of the approximately 300 other active V7 listings will meet your needs. Contact the 800 number. For application help: call 1-800-537-6945. Honeywell Sensing and Control 39 Basic Switches Miniature V7 Series TIMERSAVER SERIES PIN PLUNGERS ORDER GUIDE - SPDT* Elect. Rating P. 38 O.F. max. grams ounces R.F. min. grams ounces P.T. max. mm inches O.T. min. mm inches D.T. mm inches V7-1S17D8 1 Amp S 150 5.3 25 .88 1,19 .047 1,27 .050 0,05-0,25 .002-.010 V7-3S17E9 1 Amp S 50 1.75 5 .175 1,19 .047 1,27 .050 0,05-0,25 .002-.010 V7-3A17E9 5 Amps A 50 1.75 5 .175 1,19 .047 1,27 .050 0,05-0,25 .002-.010 V7-2B17D8 11 Amps B 75 2.63 10 .35 1,19 .047 1,27 .050 0,05-0,25 .002-.010 V7-2B17E9 11 Amps B 75 2.63 10 .35 1,19 .047 1,27 .050 0,05-0,25 .002-.010 V7-1C17D8 15.1 Amps C 150 5.3 25 .88 1,19 .047 1,27 .050 0,05-0,25 .002-.010 V7-9W1AE9 15.1 Amps W (350°F) 300 10.6 25 .88 1,19 .047 1,27 .050 0,25 .010 max. V7-1V19E9 21 Amps V 175 6.1 20 .70 1,19 .047 1,27 .050 0,05-0,25 .002-.010 Catalog Listing Dim. Dwg. Fig. 1 Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel. STRAIGHT LEVERS ORDER GUIDE - SPDT* .87N LEVER TIMESAVER SERIES Dim. Dwg. Fig. 2 V7-3S17D8-002 1 Amp S 54 1.9 3 .11 1,52 .060 0,89 .035 0,33 .013 V7-1A17D8-002 5 Amps A 160 5.6 7 .25 1,52 .060 0.89 .035 0,38 .015 V7-2B17D8-002 11 Amps B 80 2.8 5 1.76 1,52 .060 0,89 .035 0,38 .015 V7-1C17E9-002 15.1 Amps C 160 5.6 17 .60 1,52 .060 0,89 .35 0,36 .014 V7-1V19E9-002 21 Amps V 185 6.5 13 .5 1,65 .065 0,89 .035 0,38 .015 1.40N LEVER TIMESAVER SERIES Dim. Dwg. Fig. 5 V7-3S17D8-022 1 Amp S 30 1.05 1 0.035 3,04 .120 2,16 .085 0,76 .030 V7-1A17E9-022 5 Amps A 85 3 8 .28 3,04 .120 1,52 .060 0,76 .030 V7-1X2AD8-022 6 Amps X (350°F) 185 6.5 15 .53 1,40 .055 0,76 .030 0,38 .015 V7-1B17D8-022 11 Amps B 82 2.9 8 .28 3,04 .120 1,7 .067 0,68 .027 V7-1C17E9-022 15.1 Amps C 82 2.9 8 .28 3,04 .120 1,7 .067 0,76 .030 V7-1V19E9-022 21 Amps V 95 3.3 5 .18 3,3 .130 1,78 .070 0,76 .030 2.34N LEVER TIMESAVER SERIES V7-3S17D8-048 1 Amp S 16 .56 .5 .018 5,97 .235 3,0 .118 1,27 .050 V7-2B17D8-048 11 Amps B 20 .7 1 .035 5,97 .235 2.92 .115 1,27 .050 V7-1C17E9-048 15.1 Amps C 85 3 4 .14 5,97 .235 1,65 .065 1,29 .051 V7-9W1AE9-048 15.1 Amps W (350°F) 90 3.2 4 .14 6,35 .250 3,15 .124 1,37 .054 * For SPST (N.O. & N.C.) circuitry, contact the 800 number. NOTE: Catalog listings in V7 Order Guides have standard .114N mounting holes. For 3mm size holes, contact the 800 number. 40 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Miniature SIMULATED ROLLER LEVERS V7 Series Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel. ORDER GUIDE - SPDT* 1.29N LEVER TIMESAVER SERIES Catalog Listing Elect. Rating P. 38 O.F. max. grams ounces R.F. min. grams ounces P.T. max. mm inches O.T. min. mm inches D.T. max. mm inches 1.29N LEVER TIMESAVER SERIES V7-1S17D8-263 1 Amp S 90 3.15 9 .32 2,79 .110 1,9 .075 0,76 .030 V7-1B17D8-263 11 Amps B 90 3.15 9 .32 2,79 .110 1,52 .060 0,76 .030 V7-1C17D8-263 15.1 Amps C 91 3.19 9 .32 2,79 .110 1,54 .061 0,61 .024 Dim. Dwg. Fig. 3 .81N ROLLER LEVER TIMERSAVER SERIES Dim. Dwg. Fig. 4 1 Amp S 90 3.15 7 .25 1,19 .047 1,02 .040 0,38 .015 V7-2B17D8-201 11 Amps B 88 3.1 7 .25 1,3 .052 1,04 .041 0,3 .012 V7-1C17E9-201 15.1 Amps C 176 6.16 19 .67 1,3 .052 0,81 .032 0,3 .012 V7-1V19E9-201 21 Amps V 205 7.2 15 .5 1,42 .056 0,81 .032 0,33 .013 1.34N ROLLER LEVER TIMESAVER SERIES Dim. Dwg. Fig. 7 V7-3S17D8-207 1 Amp S 35 1.23 2 .07 2,79 .110 2,03 .080 0,76 .030 V7-2A17D8-207 5 Amps A 43 1.51 3 .105 2,92 .115 1,52 .060 0,64 .025 V7-1C17E9-207 15.1 Amps C 86 3 9 .32 2,84 .112 1,63 .064 0,64 .025 V7-1V19E9-207 21 Amps V 100 3.5 7 .25 3,07 .121 1,65 .065 0,76 .030 * For SPST (N.O. & N.C.) circuitry, contact the 800 number. NOTE: Catalog listing in V7 Order Guides have standard .114N mounting holes. For 3mm size holes, contact the 800 number. ORDER GUIDE – ACCESSORIES Catalog Listing Description 15PA176-V7 Connector/Receptacle packet - Includes 25 connectors and 75 receptacles with 18 N, blue 16 gauge PVC insulated, stranded wire. (To be used with D8 terminals only). 15PA260 Plunger boot seal. Elastomer dust and splash resistant plunger seal. Catalog Listing 15PA177-V7 Description Insulator packet (500 pcs.) .018N thick varnished fiberglass. Dimensions shown are for reference only. For application help: call 1-800-537-6945. Honeywell Sensing and Control 41 Miniature/ Subminiature V7-2S17D8-201 Basic Switches Miniature V7 Series INTERNATIONAL SERIES PIN PLUNGER Elect. Rating P. 38 O.F. max. grams ounces R.F. min. grams ounces P.T. max. mm inches O.T. min. mm inches D.T. mm inches V7-1B11E9 11 Amps B 150 5.3 25 .88 1,19 .047 1,27 .050 0,05-0,25 .002-.010 V7-2B11D8 11 Amps B 75 2.63 10 .35 1,19 .047 1,27 .050 0,05-0,25 .002-.010 V7-2B11PO2 11 Amps B 75 2.63 10 .35 1,19 .047 1,27 .050 0,05-0,25 .002-.010 V7-3E11D8 10 Amps E 50 1.75 5 .175 1,19 .047 1,27 .050 0,05-0,25 .002-.010 V7-3E11E9 10 Amps E 50 1.75 5 .175 1,19 .047 1,27 .050 0,05-0,25 .002-.010 Catalog Listing Dim. Dwg. Fig. 1 STRAIGHT LEVERS Dim. Dwg. Fig. 5 SIMULATED ROLLER LEVERS Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel. ORDER GUIDE - SPDT* INTERNATIONAL SERIES 1.40 N LEVER INTERNATIONAL SERIES V7-1B11E9-022 11 Amps B 80 2.8 8 .28 2,79 .110 2,28 .090 0,76 .030 V7-2B11E9-022 11 Amps B 45 1.58 4 .14 2,79 .110 2,28 .090 0,76 .030 V7-3E11D8-022 10 Amps E 30 1.05 2 .070 2,79 .110 2,28 .090 0,76 .030 1.29N LEVER INTERNATIONAL SERIES V7-2B11D8-263 11 Amps B 50 1.75 5 .175 2,54 .100 1,9 .075 0,76 .030 V7-3E11E9-263 10 Amps E 33 1.16 2 .070 2,54 .100 1,9 .075 0,76 .030 Dim. Dwg. Fig. 3 ROLLER LEVERS ORDER GUIDE - SPDT* .81N LEVER INTERNATIONAL SERIES V7-2B11D8-201 11 Amps B 90 3.15 10 .35 1,19 .047 1,02 .040 0,38 .015 V7-3E11D8-201 10 Amps E 62 2.17 5 .175 1,19 .047 1,02 .040 0,38 .015 5 .175 2,54 .100 2,16 .085 0,76 .030 Dim. Dwg. Fig. 4 1.34N LEVER INTERNATIONAL SERIES V7-2B11E9-207 11 Amps B 45 1.58 NOTE: Catalog listings in V7 Order Guides have standard .114N mounting holes. For 3mm size holes, contact the 800 number. Dim. Dwg. Fig. 7 42 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Miniature V7 Series MOUNTING DIMENSIONS (for reference only) PIN PLUNGER Fig. 1 Miniature/ Subminiature Fig. 2 Straight Lever (Style-002) Fig. 3 Simulated Roller (Style-263) Fig. 4 Roller Lever (Style-201) Fig. 5 Straight Lever (Style-022) Fig. 6 Straight Lever (Style-048) Fig. 7 Roller Lever (Style-207) NOTE: All levers are 0.17N (4,31 mm) wide. Rollers are 0.19N (4,82 mm) wide. NOTE: Operate point dimensions taken at top of lever/roller. For application help: call 1-800-537-6945. Honeywell Sensing and Control 43 BASIC SWITCHES ZM, ZX, ZV and ZW Series Subminiatur e Basic Switche s zx App Straight /ever 9 .8 0.78 Ele l ZM, ZX, ZV and ZW Series Subminiature Basic Switches are cost effective devices used for simple on/off applications . These switche s combine small size and light weight with ample electrical capability an d long life . Plastic lever capability is available on the ZV Series . Electrical rating : Voltage : Operating temperature : Termination : Contact type : Switching options : 01 i 0 .1 A, 3 A, 5 A or 10 .1 A 125/250 Va c 25 °C to 85 °C [-13 °F to 185 °F ] Quick connect, solder, PC B Gold or silve r SPDT T1 ll' ~w1 `rJ 8.8 0 .346 ZM Series Approvals : Electrical rating : 5.1 0 200 I 7 .3 0.287 9S 0.374 0 .6 0.02 4 5.2 I 0.205 UL/CS A 0 .1 A, 5 A or 10.1 A TERMINATION Quick connect Solder OPTIONS Top pin plunge r ELECTRICAL RATIN G 5A 5A CONTACT TYPE silver silver REFERENCE ZM50E70DO 1 ZM50E10DO1 Simulated roller lever Wlis n 19 .8 0.78 3.2 3.9 0 .154 D_126 12 .7 0.50 0 +0.1 m70 .4-0 ~ +0 .004 00,0940 m2. 5 0009 . 8 0 1 .6 0 .0633 8.8 0 .346 5.1 0 .200 S 7. 3 0.25 7 9 .5 0.374 _ 5 .2 0 .205 55-53 TERMINATION Quick connect Solder PCB Solder ELECTRICAL RATING 5A 5A 10.1 A 0.1 A CONTACT TYPE silver silver silver gold REFERENC E ZM50E70AO 1 ZM50E1OA0 1 ZM90G2OAO 1 ZM10BI0A01 0. 6 0 02 4 0 .346 5 .1 0 .200 TERMINATION Quick connec t Solder Honeywell www.honeywell .com/sensin g 9 .5 0 .374 0205 ' ELECTRICAL RATING 5A 5A CONTACT TYPE silver silver REFERENC E ZM50E70EO1 ZM50E10EO1 I BASIC SWITCHES IW ZX Serie s Simulated roller leve r Approvals : Electrical rating : U L/C S A 0 .1 A or 3 A n L I OPTIONS 1I Top pin plunger 57 0 .2 24 2 .9 0 .114-- 01 to 2 .7 0 .5 5.2 0 .205 11 2 0 .044 P 57 1 1— .05 '0 .081 _92 ''6 -121 J0 e 0 J -I - - 0 .1 6 .5 0 .435 I- -. -5 .08 _L 02 -- 6 .5 0.256 3 .1 5 0 .124 5.08 5 .08 0.2 0 .2 0.4 001 6 - .-- _ 12 8 0 .506 TERMINATION PCB Solder I 3 .1 5 1 0 .4 +~ -001 6 112 424-1- 0 .049 5 .08 02 5 .8 0228 ELECTRICAL RATING 3A 3A CONTACT TYP E silve r silver REFERENC E ZX40E30EO 1 ZX40E10E0 1 0.04 9 5 .8 0.228 12 .8 0.504 ZV Series TERMINATION PCB Solder ELECTRICAL RATING 3A 0.1 A CONTACT TYPE silve r gold REFERENCE ZX40E30AO1 ZX10C10AO1 Approvals : Electrical rating : UL/ENE C 0 .1 A, 5 A or 10 .1 A OPTIONS Straight lever Top pin plunge r 2 .7 0 .5 57 0 .22 4 19 .8 0.78 2.9 0 .114 2.2 5 0 .08 9 4.85 D.191 I 12. 7 0.50 0 al g ) Pt: dra 02 .4- 0 o oo' 00098 1. 6 0.063 0.4 0 .01 6 TERMINATIO N PCB Solder ELECTRICAL RATING 3A 3A 8.8 0.374 .1 0 .200 0 .04 9 5.8 0 .22 8 0.504 CONTACT TYPE silve r silver REFERENCE ZX40E30001 ZX40E10001 TERMINATIO N PC B Solde r Quick connect hr,r, A\r\A/r.11 es" MS /0, ',I, .0940 7.3 0.287 9.5 0.374 ELECTRICAL RATING 5A 5A 0 .1 A Honeywel l IAn An AI 00I 0.6 0 .02 4 5 .2 0.205 CONTACT TYPE silver s3vvr gold REFERENC E ZV50E20A01 ZV50E10A0 1 ZVI OB70AO 1 IA : BASIC SWITCHES S ZW Sealed Series Straight lever Approvals : Electrical rating : 19 .8 0.78 2.2 5 4.85 0 .08 9 0 .191 ~ OPTIONS L- Ir~ Top pin plunge r - . S~ A ~~ 1.6 88 5 .1 0.200 0 .29 5 L 7. 3 0.374 0 .063 0 .191 I +0. 1 ! 0, 2 .4-,O ' 00.0941'0 02' 5 00.098 TERMINATION Solder Quick connect S 12 .7 0 .500 17 . 4 ft UL/ENE C 0 .1 Aor5A Ri 0.28 7 9 .5 I 0 .374 ELECTRICAL RATING 5A 5A 52 0.205 CONTACT TYPE silver silver 2Io TE W REFERENC E ZV50E10B0 1 ZV50E7000 1 7.5 0.295 7 .5 0 .295 9 .5 0 .3/ 4 19. 8 0.780 5 2 5.205 Roller lever TERMINATION Solder 6. 4 0.252 3.55 4 2 .4C 094 ELECTRICAL RATING 5A CONTACT TYPE silve r REFERENC E ZW50F15AD1 (C 0.140 Straight lever I II 90, 3 0.01 2 3z I .2 0.04 7 0.126 TERMINATIO N PCB Quick connect ELECTRICAL RATING 5A 5A CONTACT TYPE silver silver REFERENC E ZV50E20FO1 ZV50E70FO1 520 0 .205 9.5 C 0 .37 4 19 .8 0.780 TERMINATION Solder Honeywel l www.honeywell .com/sensin g ELECTRICAL RATING 0.1 A CONTACT TYPE gold REFERENC E ZW1OE15CD1 • • Roller leve r CON : BLACK NO,CYAN Y 1 0} OS a ° 0.11830 .020 ° I TERMINATION Wire leads I NC_ 0R A Y 5.2 9 .5 0.205 0.37 4 19. 8 0 .780 ELECTRICAL RATING CONTACT TYPE 0.1 A gold J J 001.0.B 1 6 .4 0.252 REFERENCE ZW10E90FW 1 S (t (5 Honeywel l www.honeywell .com/sensing m Basic Switches Miniature Double-break TB Series FEATURES 1 Power load switching capability up to 10 amperes 1 Motor handling capacity of 1⁄2 horsepower, 125 VAC 1 Two- and four-circuit double-break 1 Several auxiliary actuators 1 Choice of terminal styles 1 UL recognized, CSA certified 1 Momentary action Description The terminals of two- and four-circuit double break switches must be wired to identical voltage sources and the same polarity so that a voltage potential is not set up between adjacent terminals. A voltage potential between adjacent terminals could promote dielectric breakdown at high energy levels. The loads should be on the same sides of the line. Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating Position. ORDER GUIDE Catalog Listing GENERAL INFORMATION TB miniature switches are basic doublebreak units which offer a means of controlling isolated circuits. Each circuit can be driven by independent voltage sources. These switches find many uses in modern control systems because of their circuitry. Electrical Data And UL Code Page 20 O.F. newtons ounces R.F. min. newtons ounces P.T. max. mm inches O.T. min. mm inches D.T. mm inches O.P.** mm inches 1TB1-1 Two-circuit, doublebreak end screw terminals 10 Amps Z 1,95-3,61 7-13 1,11 4 1,52 .060 0,25 .010 0,25-0,64 .010-.025 11,7 .460 1TB1-2 Two-circuit, doublebreak end solder terminals 10 Amps Z 1,95-3,61 7-13 1,11 4 1,52 .060 0,25 .010 0,25-0,64 .010-.025 11,7 .460 1TB1-3 Two-circuit, doublebreak front solder terminals 10 Amps Z 1,95-3,61 7-13 1,11 4 1,52 .060 0,25 .010 0,25-0,64 .010-0.25 11,7 .460 41TB5-3 Four-circuit, doublebreak front solder terminals 10 Amps Z 5,56-10,0 20-36 2,22 8 1,78 .070 0,25 .010 0,64-1,14 .025-.045 4,70 .185 Dim. Dwg. Fig. 1 Dim. Dwg. Fig. 2 Dim. Dwg. Fig. 3 * ±0,38 mm ±.015 in Dim. Dwg. Fig. 4 44 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Miniature Double-break TB Series AUXILIARY ACTUATORS For use with 1TB1-1 and 1TB1-2 switches ORDER GUIDE Catalog Listing JT-1 Description JT-1 Leaf actuator JT-5 Roller leaf actuator JT-5 Switches are not included with the actuators. Miniature/ Subminiature MOUNTING DIMENSIONS (For reference only) Fig. 1 Fig. 2 Fig. 3 Fig. 4 For application help: call 1-800-537-6945. Honeywell Sensing and Control 45 Basic Switches Standard BZ/BA Series STANDARD BASIC SWITCH CUT-A-WAY The cut-a-way shown is representative of the standard basic switches described in this catalog. GENERAL INFORMATION MICRO SWITCH standard basic switches are precision snap-action mechanisms enclosed in accurately molded plastic cases. These switches are carefully manufactured and thoroughly inspected. They are industry known for their compactness, light weight, accurate repeatability and long life. Mounting holes for Types BZ, BM, BA, BE, DT, MT, and 6AS switches accept pins or screws of .139 inch (3,53 mm) diameter. Characteristics as stated are taken at normal room temperature and humidity. These may vary as temperature and humidity conditions differ. GENERAL SWITCH IDENTIFICATION Standard Basic Switches MOUNTING DIMENSIONS Mounting dimensions are included at the end of each product section. They are shown in English and metric equivalents. These dimensions are for reference only. For exacting layout work, request an engineering layout work, request an engineering drawing from the 800 number. The type BZ switch design meets most applications needs. Modifications of the standard silver contact design and material, spring configuration, and plunger locations give the type BM, BA and BE switches greater electrical load handling capacity. Other changes in materials and switch design provide operating characteristics, temperature tolerances, and sealing to cover a wide range of special requirements. FEATURES 1 Operating force as low as 4 oz. (113 grams) maximum 1 Sensitive differential travel as low as .0002 to .0003 inches (0,005 to 0,008 mm) 1 Power load switching capability to 25 amperes 1 Motor handling capacity to 2 horsepower at 250 VAC 1 Long mechanical life 1 High temperature constructions for up to +400°F (204°C) 1 Momentary or maintained contact action 1 Alloy contacts available for special application needs 1 Variety of integral actuators 1 Variety of auxiliary actuators 1 Variety of terminal designs 1 Optional sealed plunger and cover 1 Stainless steel snap spring available 1 Military standard construction available with over 50 listings on the MILS-8805 Qualified products list 1 UL recognized, CSA certified First letter in catalog listing designates: B = Single-pole double-throw W = Single-pole single-throw (normally closed) Y = Single-pole single-throw (normally open) Second letter in catalog listing designates: Z = Standard 15-amp version M = 22-amp version A = Standard 20-amp version E = 25-amp version RECOMMENDED TORQUE (max.) Mounting screws . . . . . . . . . . . . 3 in./lbs.* Terminal screws . . . . . . . . . . . . . . 4 in./lbs. Panel mount bushing . . . . . . . 4-6 in./lbs. *Note: Tightening mounting screws above 3 in./lbs. changes operating characteristics and increases the possibility of cracking the case. This section covers only over 100 of our most popular BZ/BA type Series catalog listings. If you don’t find what you’re looking for, it’s likely one of the approximately 1800 other active listings will meet your needs. Contact the 800 number. UL/CSA Our basic switches are Component Recognized by Underwriters’ Laboratories, Inc. and certified by Canadian Standards Association. The BA, BZ, and BM line is covered as Special Use Switches to UL Standard 1054; the BE line is covered as an Industrial Motor Controller to UL Standard 508. Agency File References are: BA BM BZ BE-1,2,5 BE-R For application help: call 1-800-537-6945. UL File E12252, issued 12-09-88 UL File E12252, issued 12-08-88 UL File E12252, issued 6-29-89 UL File E22779, Vol. 4, Sec. 1 UL File E22779, Vol. 4, Sec. 2 Honeywell Sensing and Control 47 Basic Switches Standard BZ/BA Series AVAILABLE TERMINALS Most of the BZ/BA catalog listings have A2 type terminals. Several other terminal styles are shown and others are available. Specific information should be requested from the 800 number or local Authorized Distributor. Solder (No suffix) Use up to #14 wire A2 Bottom facing 6-32 NC × .218N screw with cup washers A4 (Same as A2 except #8 screws) D6 .250N (6,35 mm) wide × .032N (0,81 mm) thick quick-connect D5 .250N (6,35 mm) wide × .030N (7,62) thick quick-connect T Bottom facing 6-32 NC × .218N screw with Sems lockwashers P4 Side facing 8-32 × .218N screw with cup washers PC2 Self lifting pressure plate terminals and plastic barriers for added dielectric protection ACTUATORS BA, BE, BM and BZ standard basic switches use the actuators described. 48 Pin plunger; in-line motion Overtravel plunger; in-line applications requiring additional overtravel Roller lever; Very low force, fast moving cams Roller leaf; Low-force, large movement actuation Honeywell Sensing and Control Added overtravel in a panel mount roller plunger; Actuation by cams Leaf; Low-force, slow moving cams or slides Lever; Very low force, slow cams and slides Added overtravel in a panel-mount plunger; Heavy-duty in-line applications or slow cams. Cam rise should not exceed 30° For application help: call 1-800-537-6945. Basic Switches Standard BZ/BA Series Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Position. ORDER GUIDE by ascending electrical capability PIN PLUNGER Catalog Listing BZ/BA TYPE Dim. Dwg. Fig. 1 Electrical Data And O.F. R.F. min. P.T. max. O.T. min. UL Codes newtons newtons mm mm Recommended For Page 46 ounces ounces inches inches Applications requiring gold alloy contacts 1 Amp P 2,5-3,61 9-13 1,11 4 0,38 .015 0,13 .005 0,01-0,05 .0004-.0020 15,88 .625 BZ-2R725551-A2 Gold alloy contacts Dustproof and splash resistant seal 1 Amp P 2,22-4,17 8-15 1,11 4 — — 0,13 .005 0,01-0,06 .0004-.0025 15,88 .625 BZ-2R244-A2 Operating in temp. to +400°F (204°C) for 100 hours 5 Amps B 2,5-3,61 9-13 1,11 4 0,38 .015 0,13 .005 0,01-0,05 .0004-.0020 15,88 .625 BZ-R21-A2 Lower force 10 Amps C 1,11 4 0,7 2.5 0,30 .012 0,13 .005 0,005-0,013 .0002-.0005 15,88 .625 BZ-2R-A2 Most applications SPDT 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 0,13 .005 0,01-0,05 .0004-.0020 15,88 .625 WZ-2R-A2 SPST (normally closed) 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 0,13 .005 0,01-0,05 .0004-.0020 15,88 .625 YZ-2R-A2 SPST (normally open) 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 0,13 .005 0,01-0,05 .0004-.0020 15,88 .625 BZ-R-A2 Less differential travel 15 Amps D 1,95-2,5 7-9 1,11 4 0,30 .012 0,13 .005 0,005-0,008 .0002-.0003 15,88 .625 BZ-R19-A2 Best repeatability 15 Amps D 1,95-3,34 7-12 1,11 4 0,30 .012 0,13-0,2 0,005-0,02 .005-.008 .0002-.0008 16,26 .640 BZ-2R24-A2 Operating in temp. to +250°F (121°C) 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 0,13 .005 0,01-0,05 .0004-.0020 15,88 .625 BZ-2RT04 (8805/1-004) MIL-S-8805 application requirements 15 Amps A 2,5-3,61 9-13 1,67 6 0,38 .015 0,13 .005 0,01-0,05 .0004-.0020 15,88 .625 BZ-2R05-A2 Best stability under varying humidity 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 0,13 .005 0,01-0,05 .0004-.0020 15,88 .625 BZ-2R5551-A2 Dustproof and splash resistant seal 15 Amp A 2,5-4,17 9-15 1,11 4 — — 0,13 .005 0,01-0,06 .0004-.0025 15,88 .625 BZ-2R55-A2-S Best service for sealed construction. Stainless steel internal snap spring. 15 Amps A 2,5-4,17 9-15 1,11 4 — — 0,13 .005 0,01-0,06 .0004-.0025 15,88 .625 BA-2R-A2 Up to 20 ampere load handling 20 Amps G 3,89-6,12 14-22 2,78 10 1,27 .050 0,25 .010 0,05-0,19 .0020-.0075 16,26 .640 BA-2R24-A2 Operating in temperature to +250°F (121°C) 20 Amps G 3,89-6,12 14-22 2,78 10 1,27 .050 0,25 .010 0,05-0,19 .0020-.0075 16,26 .640 BM-1R-A2 Up to 22 ampere load handling 22 Amps F 1,95-2,78 7-10 1,11 4 0,38 .015 0,13 .005 0,013-0,025 .0005-.0010 15,88 .625 BE-2R-A4 Up to 25 ampere load handling 25 Amps H 3,89-6,12 14-22 2,78 10 1,27 .050 0,25 .010 0,05-0,19 .0020-.0075 16,26 .640 BZ-RX Manual reset (maintained contact) applications, solder terminals 15 Amps E 1,95-2,5 7-9 0,56-2,78* 2-10 — — — — 0,30 .012 — — 0,13 .005 0,38* .015 — — 15,88 .625 WA-1RX-A4 Manual reset SPSTNC, A4 terminals 20 Amps W 5,56 20 6,95* 25 — — — — — — — — 0,25 .010 — — 0,20 .008 — — 16,26 .64 27,9* 1.10 Dim. Dwg. Fig. 3 Dim. Dwg. Fig. 4 Except where stated ** ±0,38mm ±.015 in. *Reset characteristics. All catalog listings shown are not necessarily stock items. Stocking depends on sales experience. For application help: call 1-800-537-6945. Auxiliary actuators see p. 62-63. Honeywell Sensing and Control 49 Standard Basic Switches BA/BE TYPE O.P.** mm inches BZ-2R72-A2 SEALED TYPE Dim. Dwg. Fig. 2 D.T. mm inches Basic Switches Standard BZ/BA Series Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Position. OVERTRAVEL PLUNGER ORDER GUIDE Catalog Listing Recommended For Electrical Data and UL Codes Page 46 O.F. newtons ounces R.F. min. newtons ounces P.T. max. mm inches O.T. min. mm inches D.T. mm inches O.P.* mm inches BZ-2RD72-A2 Applications requiring gold alloy contacts 1 Amp P 2,5-3,61 9-13 1,11 4 0,38 .015 1,52 .060 0,01-0,05 .0004.0020 21,21 .835 BZ-2RD-A2 Added overtravel. For manual operation and slow 20° (max) cam rise 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 1,52 .060 0,01-0,05 .0004.0020 21,21 .835 BZ-2RD24-A2 Operating in temperature to +250°F (121°C) 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 1,52 .060 0,01-0,05 .0004.0020 21,21 .835 BM-1RD-A2 Up to 22 ampere load handling 22 Amps F 1,95-2,78 7-10 1,11 4 0,38 .015 1,52 .060 0,013-0,025 .0005.0010 21,21 .835 BZ-2RDS725551-A2 Applications requiring gold alloy contacts plus dustproof and splash resistant seal 1 Amp P 3,61-5,28 13-19 1,11 4 — 1,52 .060 0,01-0,063 .0004.0025 28,20 1.110 Dustproof and splash resistant seal 15 Amps A 3,61-5,28 13-19 1,11 4 — 1,52 .060 0,01-0,063 .0004.0025 28,20 1.110 BA-2RB-A2 Up to 20 ampere load handling 20 Amps G 3,89-6,12 14-22 2,78 10 1,27 .050 2,39 .094 0,05-0,19 .0020.0075 26,20 1.03 BE-2RB-A4 Up to 25 ampere load handling 25 Amps H 3,89-6,12 14-22 2,78 10 1,27 .050 2,39 .094 0,05-0,19 .0020.0075 26,20 1.03 BZ-2RS72-A2 Applications requiring gold alloy contacts 1 Amp P 2,5-3,61 9-13 1,11 4 0,38 .015 1,52 .060 0,01-0,05 .0004.0020 28,20 1.110 BZ-2RS-A2 Added overtravel. For in-line operation and with JR auxiliary actuators 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 1,52 .060 0,01-0,063 .0004.0025 28,20 1.110 BZ-2RS24-A2 Operating in temperature to +250°F (121°C) 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 1,52 .060 0,01-0,05 .0004.0020 28,20 1.110 MIL-S-8805 application requirements 15 Amps A 2,5-3,61 9-13 1,67 6 0,38 .015 1,52 .060 0,01-0,05 .0004.0020 28,20 1.110 BZ-RSX Manual reset solder terminals 15 Amps E 1,95-2,64 7-9 — — 0,30 .012 0,64 .025 — — 2,79 1.11 BM-1RS-A2 Up to 22 ampere load handling 22 Amps F 1,95-2,78 7-10 1,11 4 0,38 .015 1,52 .060 0,013-0,025 .0005.0010 28,20 1.110 BZ-2RS7225551-A2 Applications requiring gold alloy contacts plus dustproof and splash resistant seal 1 Amp P 2,5-4,17 9-15 1,11 4 — 1,52 .060 0,01-0,063 .0004.0025 28,20 1.110 15 Amps A 2,5-4,17 9-15 1,11 4 — 1,52 .060 0,01-0,063 .0004.0025 28,20 1.110 Dim. Dwg. Fig. 11 BZ-2RDS5551-A2 Dim. Dwg. Fig. 12 Dim. Dwg. Fig. 13 BZ-2RST04 (M8805/1-012) Dim. Dwg. Fig. 14 BZ-2RS5551-A2 Dustproof and splash resistant seal *±0,51 mm ±.020 in. Dim. Dwg. Fig. 15 50 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Standard OVERTRAVEL PLUNGER BZ/BA Series ORDER GUIDE Catalog Listing Recommended For Electrical Data and UL Codes Page 46 O.F. newtons ounces R.F. min. newtons ounces P.T. max. mm inches O.T. min. mm inches D.T. mm inches O.P.** mm inches BZ-2RQ-A2 Added overtravel. For manual in-line operation and for slow 30° (max) rise cams 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 5,56 .219 0,01-0,05 .0004.0020 38,10±0,51 1.500±.020 BZ-2RQ24-A2 Operating in temperature to ±250°F (121°C) 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 5,56 .219 0,01-0,05 .0004.0020 38,10±0,51 1.500±.020 BZ-2RQ172-A2 Applications requiring gold alloy contacts 1 Amp P 2,5-3,61 9-13 1,11 4 0,38 .015 5,56 .219 0,01-0,05 .0004.0020 21,82 .859 BZ-2RQ1-A2 BZ-2RQ-A2 type applications with panel mount 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 5,56 .219 0,01-0,05 .0004.0020 21,82 .859 MIL-S-8805 application requirements 15 Amps A 2,5-3,61 9-13 1,67 6 0,38 .015 5,56 .219 0,01-0,05 .0004.0020 21,82 .859 BZ-2RQ124-A2 Operating in temperature to ±250°F (121°C) 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 5,56 .219 0,01-0,05 .0004.0020 21,82 .859 BZ-2RN702 Furnished with unassembled seal boot. 15 Amps X 2,5-3,61 9-13 1,11 4 0,38 0.15 3,18 .125 0,01-0,05 .0004.0020 48,4±0,50 1.906±.020 BZ-RQ1X Manual reset. Solder terminals 15 Amps E 1,67-2,64 6-9.5 – – 0,30 0.12 5,56 .219 – – 23,42±1,14 .922±.045 7,14* .281* BA-2RQ1-A2 Up to 20 ampere load handling 20 Amps G 3,89-6,12 14-22 2,78 10 1,27 .050 5,56 .219 0,05-0,19 .0020.0075 21,82 .859 BM-1RQ1-A2 Up to 22 ampere load handling 22 Amps F 1,95-2,78 7-10 1,11 4 0,38 .015 5,56 .219 0,0130,025 .0005.0010 21,82 .859 BZ-2RQ1872-A2 Applications requiring gold alloy contacts 1 Amp P 2,5-3,61 9-13 1,11 4 0,38 .015 3,56 .140 0,01-0,05 .0004.0020 33,32±1,14 1.312±.045 BZ-2RQ18-A2 Added overtravel. Roller plunger for rapid cam (30° max) rise and slide operation. Panel mount 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 3,56 .140 0,01-0,05 .0004.0020 33,32±1,14 1.312±.045 BZ-2RQ1824-A2 Operating in temperature to ±250°F) (121°C) 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 3,56 .140 0,01-0,05 .0004.0020 33,32±1,14 1.312±.045 BZ-2AQ18T1 Double-break circuitry 15 Amps T 3,89-6,68 14-24 1,11 4 0,51 .020 3,58 .141 0,03-0,10 .001-.004 33,35±1,19 1.313±.047 BM-1RQ18-A2 Up to 22 ampere load handling 22 Amps F 1,95-2,78 7-10 1,11 4 0,38 .015 3,56 .140 0,0130,025 .0005.0010 33,32±1,14 1.312±.045 BZ-2RQ181-A2 Applications requiring roller plunger 90° to major axis of switch 15 Amps A 2,5-3,61 9-13 1,11 4 0,38 .015 3,56 .140 0,01-0,05 .0004.0020 33,32±1,14 1.312±.045 Dim. Dwg. Fig. 16 BZ/BM TYPE BZ-2RQ1T04 (M8805/1-020) Dim. Dwg. Fig. 17 BA TYPE Dim. Dwg. Fig. 19 * Reset characteristics. Dim. Dwg. Fig. 20 For application help: call 1-800-537-6945. Except where stated ** ±0,76 mm ±.030 in. Honeywell Sensing and Control 51 Standard Basic Switches Dim. Dwg. Fig. 18 Basic Switches Standard BZ/BA Series Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Position. STRAIGHT LEVER ORDER GUIDE Recommended For Catalog Listing BZ-2RW8072-A2 D.T. mm inches O.P.** mm inches 1 Amp P 0,7 2.5 0,14 0.5 — 5,56 .219 0,18-1,27 .007-.050 19,1 .750 Best stability under varying humidity. Gold alloy contacts with seal 1 Amp P 0,7 2.5 0,14 0.5 — 5,56 .219 0,18-1,27 .007-.050 19,1 .750 Operating in temp. to +400°F (204°C) for 100 hours 5 Amps B 0,7 2.5 0,14 0.5 — 5,56 .219 0,18-1,27 .007-.050 19,1 .750 Lowest operating force (without external return spring) 10 Amps I 0,07 .25 — 6,76 .266 5,56 .219 0,08-0,38 .003-.015 19,1 .750 1.25 inch lever requirements 15 Amps A 1,67 6 0,42 1.5 — 0,42 .141 0,10-0,63 .004-.025 19,1 .750 2.5 inch lever requirements 15 Amps A 0,7 2.5 0,14 0.5 — 5,56 .219 0,18-1,27 .007-.050 19,1 .750 BZ-2RW84-A2 Lower force (without external return spring) 15 Amps A 0,28 1 0,03 0.125 8,33 .328 5,56 .219 0,18-1,27 .007-.050 19,1 .750 BZ-2RW805551-A2 Dustproof and splash resistant seal 15 Amps A 0,7 2.5 0,14 0.5 — 5,56 .219 0,18−1,27 .007-.050 19,1 .750 MIL-S-8805 application requirements 15 Amps A 0,28-0,90 1-3.25 0,21 0.75 7,52 .296 4,37 .172 2,36 .093 19,1 .750 Operating in temperature to +250°F (121°C) 15 Amps A 0,7 2.5 0,14 0.5 — 5,56 .219 0,18-1,27 .007-.050 19,1 .750 BZ-RW80X Manual reset solder terminals 15 Amps E 0,63 2.25 — — — — 5,56 .219 0,38* .015 — — – – 19,05 .750 7,14* .281 BZ-2RW863-A2 6 inch lever requirements 15 Amps A 0,28 1 — — 12,7 .500 BA-2RV-A2 Up to 20 ampere load handling 20 Amps G 0,7 2.5 0,14 0.5 15,88 .625 1,98 .078 2,77 .109 19,1 .750 BM-1RW84-A2 Up to 22 ampere load handling 22 Amps F 0,28 1 0,03 0.125 7,54 .297 5,56 .219 0,13-0,84 .005-.033 19,1 .750 BE-2RV-A4 Up to 25 ampere load handling 25 Amps H 0,7 2.5 0,14 0.5 15,88 .625 1,98 .078 2,77 .109 max. 19,1 .750 Adjustable operating point (17 mm to 22 mm) .670N to .880N 15 Amps A 0.7 2.5 0.14 0.5 — 3,54 † .125 0,18-1,27 17,02-22,35 .007-.050 .670-.880 Reverse acting actuator (switch plunger depressed in free position) 15 Amps A 1,67 6 0,28 1 5,56 .219 5,56 .219 0,10-0,89 .004-.035 BZ-2RW80722555105-A2 BZ-2RW8244-A2 BZ-RW8435-A2 Dim. Dwg. Fig. 21 BZ-2RW876T BZ-2RW80-A2 BA TYPE BZ-2RWT04 (M8805/1-044) BZ-2RW824-A2 ADJUSTABLE O.T. min. mm inches Applications requiring gold alloy contacts BZ/BM TYPE Dim. Dwg. Fg. 23 Electrical Data and O.F. max. R.F. min. P.T. max. UL Codes newtons newtons mm Page 46 ounces ounces inches * Reset characteristics. BZ-2RW899-A2 BZ-2RM-A2 Dim. Dwg. Fg. 22 † From17 mm O.P. .670 in. Honeywell Sensing and Control 19,1 .750 Except where stated ** ±0.76 mm ±.030 in. Dim. Dwg. Fig. 24 52 0,46-3,68 19,1±1,52 .018-.145 .750±.060 For application help: call 1-800-537-6945. Basic Switches Standard BZ/BA Series SIMULATED ROLLER ORDER GUIDE Catalog Listing BZ-2RW80147-A2 Electrical Data And UL Code Recommended For Page 46 O.F. R.F. P.T. max. min. max. newtons newtons mm ounces ounces inches O.T. min. mm inches D.T. mm inches O.P.** mm inches 30,17 1.188 1.05 inch (26,7 mm) (simulated roller) lever applications 15 Amps A 1,67 6 0,42 1.5 — 2,39 .094 0,08-0,51 .003-.020 1.90 inch (48,3 mm) (simulated roller) lever applications 15 Amps A 0,97 3.5 0,21 0.75 — 3,96 .156 0,10-1,0 30,17±0,76 .004-.040 1.188±.030 Applications requiring gold alloy contacts 1 Amp P 1,67 6 0,42 1.5 — 2,39 .094 0,08-0,51 .003-.020 30,17 1.188 Applications requiring gold alloy contacts plus dustproof and splash resistant seal 1 Amp P 1,67 6 0,42 1.5 — 2,39 .094 0,08-0,51 .003-.020 30,17 1.188 1.05 inch (26,7 mm) (steel roller) lever applications 15 Amps A 1,67 6 0,42 1.5 — 2,39 .094 0,08-0,51 .003-.020 30,17 1.188 BZ-2RW8222-A2 Roller turned 90° 15 Amps A 0,7-1,81 2.5-6.5 0,35 1.25 — 3,58 .141 max. 0,08-0,51 .003-.020 30,75 1.25 BZ-2RW82224-A2 Operating in temperature to +250°F (121°C) 15 Amps A 1,67 6 0,42 1.5 — 2,39 .094 0,08-0,51 .003-.020 30,17 1.188 Dustproof and splash resistant seal 15 Amps A 1,67 6 0,42 1.5 — 2,39 .094 0,08-0,51 .003-.020 30,17 1.188 Best service for sealed construction. Stainless steel internal snap spring. 15 Amps A 1,67 6 0,42 1.5 — 2,39 .094 0,08-0,51 .003-.020 30,17 1.188 BA-2RV22-A2 Up to 20 ampere load handling 20 Amps G 1,67 6 0,42 1.5 6,35 .250 0,76 .030 1,14 .045 max. 29,77 1.172 BM-1RW822-A2 Up to 22 ampere load handling 22 Amps F 1,67 6 0,42 1.5 — 2,39 .094 0,025-0,33 .001-.013 30,17 1.188 BE-2RV22-A4 Up to 25 ampere load handling 25 Amps H 1,67 6 0,42 1.5 6,35 .250 0,76 .030 1,14 .045 max. 29,77 1.172 BZ-2RW82299-A2 Adjustable operating point. Roller lever 1.05 inch (26,7 mm) 15 Amps A 1,67 6 0,42 1.5 — 1,02 .040 0,08-0,51 29,77-30,56 .003-.020 1.172-1.203 Adjustable operating point. Roller lever 1.90 inch (48,3 mm) 15 Amps A 0,97 3.5 0,21 0.75 — 2,16 .085 0,10-1,0 .004-.040 BZ-2RW80196-A2 Dim. Dwg. Fig. 27 ROLLER LEVER BZ-2RW82272-A2 BZ-2RW822725551-A2 BZ/BM TYPE BZ-2RW822-A2 Dim. Dwg. Fig. 25 BZ-2RW8225551-A2 Dim. Dwg. Fig. 28 BA/BE TYPE BZ-2RW8299-A2 29,2-31,5 1.150-1.24 Dim. Dwg. Fig. 26 Except where stated * ±0,38 mm ±.015 in. For application help: call 1-800-537-6945. Honeywell Sensing and Control 53 Standard Basic Switches BZ-2RW82255-A2-S Basic Switches Standard ROLLER LEVER BZ/BM TYPE BZ/BA Series ORDER GUIDE Catalog Listing Recommended For BZ-2RW82725551-A2 Applications requiring gold alloy contacts, plus dustproof, and splash resistant seal BA/BE TYPE Dim. Dwg. Fig. 30 Electrical Data And UL Code Page 46 O.F. R.F. max. min. newtons newtons ounces ounces P.T. max. mm inches O.T. min. mm inches D.T. mm inches O.P.* mm inches 1 Amp P 0,97 3.5 0,21 0.75 — 3,96 .156 0,10-1,0 .004-.040 30,17±0,76 1.188±.030 1.90 inch (48,3 mm) (steel roller) lever applications 15 Amps A 0,97 3.5 0,21 0.75 — 3,96 .156 0,10-1,0 .004-.040 30,17±0,76 1.188±.030 Dustproof and splash resistant seal 15 Amps A 0,97 3.5 0,21 0.75 — 3,96 .156 0,10-1,0 .004-.040 30,17±0,76 1.188±.030 Operating in temperature to +250°F (121°C) 15 Amps A 0,97 3.5 0,21 0.75 — 3,96 .156 0,10-1,0 .004-.040 30,17±0,76 1.188±.030 BA-2RV2-A2 Up to 20 ampere load handling 20 Amps G 0,97 3.5 0,14 0.5 11,89 .468 1,52 .060 2,16 .085 30,17±0,76 1.188±.030 BM-1RW82-A2 Up to 22 ampere load handling 22 Amps F 0,97 3.5 0,21 0.75 — 3,96 .156 0,08-0,56 .003-.022 30,17±0,76 1.188±.030 Up to 25 ampere load handling 25 Amps H 0,97 3.5 0,14 0.5 11,89 .468 1,52 .060 2,16 .085 max. 30,17±0,76 1.188±.030 BZ-2RW82-A2 Dim. Dwg. Fig. 29 Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Position. BZ-2RW825551-A2 BZ-2RW8224-A2 BE-2RV2-A4 NOTE: For adjustable operate point and simulated roller lever switches, refer to previous page. BZ-RW922-A2 Best repeatability and O.P. stability 10 Amps I 3,34 12 1,11 4 0,38 .015 2,54 .100 0,013-0,025 .0005-.0010 31,37 1.235 BZ-2RW826-A2 One-way roller (9,4 mm H 3,8 mm) .37N dia. H .15N wide roller 15 Amps A 1,67 6 0,42 1.5 — 2,39 .094 0,08-0,51 .003-.020 41,34 1.625 One-way roller (4,83 mm H 4,83 mm) .19N dia. H .19N wide roller 15 Amps A 2,22 8 0,42 1.5 — 1,52 .060 0,38 .015 28,96 1.14 Dim. Dwg. Fig. 31 BZ-2RW825-A2 Dim. Dwg. Fig. 32 54 Honeywell Sensing and Control Except where stated * ±0,38 mm ±.015 in. For application help: call 1-800-537-6945. Basic Switches Standard FLEXIBLE LEAF BZ/BA Series ORDER GUIDE Electrical Data and UL Codes Page 46 O.F. max. newtons ounces Force and stability of the flexible leaf actuator 15 Amps A 1,39 5 0,14 0.5 – 1,52 .060 1,27 .050 17,48 .688 Dustproof and splash resistant seal 15 Amps A 1,95 7 0,14 0.5 – 1,52 .060 1,27 .050 17,48 .688 BZ-2RLT04 (M8805/1-001) MIL-S-8805 application requirements 15 Amps A 1,39 5 0,14 0.5 – 1,52 .060 1,27 .050 17,48 .688 BZ-2RL24-A2 Operating in temperature to +250°F (121°C) 15 Amps A 1,39 5 0,14 0.5 – 1,52 .060 1,27 .050 17,48 .688 BZ-RLX Manual reset. Solder terminals 15 Amps E 0,83 3 – – – – 1,57 .062 0,38* .015 – – – – 17,48 .688 7,14* .281 BA-2RL-A2 Up to 20 ampere load handling 20 Amps G 2,5 9 0,28 1 – 1,57 .062 1,57 .062 17,48 .688 Up to 25 ampere load handling 25 Amps H 2,5 9 0,28 1 – 1,57 .062 1,57 .062 17,48 .688 Electrical Data and UL Codes Page 46 O.F. max. newtons ounces Operating in temp. to +250°F (121°C) for 100 hours 5 Amps B 1,39 5 0,14 0.5 – 1,52 .060 1,27 .050 28,6 1.125 Force and stability of the flexible leaf with roller 15 Amps A 1,39 5 0,14 0.5 – 1,52 .060 1,27 .050 28,6 1.125 Dustproof and splash resistant seal 15 Amps A 1,95 7 0,14 0.5 – 1,52 .060 1,27 .050 28,6 1.125 BZ-2RL2T04 (M8805/1-036) MIL-S-8805 application requirements 15 Amps A 1,04-1,39 3.75-5 0,14 0.5 – 1,52 .060 1,27 .050 28,6 1.125 BA-2RL2-A2 Up to 20 ampere load handling 20 Amps G 2,5 9 0,28 1 – 1,52 .060 1,65 .065 28,6 1.125 Up to 25 ampere load handling 25 Amps H 2,5 9 0,28 1 – 1,52 .060 1,65 .065 28,6 1.125 Catalog Listing BZ TYPE BZ-2RL-A2 BZ-2RL5551-A2 Dim. Dwg. Fig. 33 BA/BE TYPE Dim. Dwg. Fig. 34 BE-2RL-A4 FLEXIBLE ROLLER LEAF BZ TYPE Catalog Listing BZ-2RL25551-A2 BA/BE TYPE BE-2RL2-A4 Recommended For R.F. min. P.T. max. O.T. min. D.T. max. newtons mm mm mm ounces inches inches inches * Reset characteristics For application help: call 1-800-537-6945. O.P.* mm inches ** ±0.76 mm ±.030 in. Honeywell Sensing and Control 55 Standard Basic Switches BZ-2RL2-A2 Dim. Dwg. Fig. 36 O.P.** mm inches ORDER GUIDE BZ-RL24-A2 Dim. Dwg. Fig. 35 Recommended For R.F. min. P.T. max. O.T. min. D.T. max. newtons mm mm mm ounces inches inches inches Basic Switches Standard BZ/BA Series GENERAL INFORMATION SPECIAL CIRCUITRY SWITCHES ‘‘Special sequence’’ switches provide unusual circuit control. A make-beforebreak switch provides circuit continuity while switching from N.C. to N.O. In another make-before-make switch, upon actuation, one circuit is made an interval before the second circuit. Another switch provides a single pulse or momentary closure of the contacts with each cycle of operation. Double break versions can interrupt greater inductive loads and feature shorting bar construction. A split contact version allows control of the two isolated circuits. Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating Position. PIN PLUNGER ORDER GUIDE Catalog Listing BZ-2G-A2 Dim. Dwg. Fig 5 Unoperated Intermediate 6BS1-B Recommended For Make-before-break contact action Fully Operated Make-before-make contact action Electrical Data and UL Codes Page 46 O.F. newtons ounces 10 Amps C 5,56 20 max. R.F. min. P.T. max. O.T. min. newtons mm mm ounces inches inches 2,22 8 Intermediate Release 10 Amps R 9,73 35 max. 0,76 .030 D.T. mm inches O.P.* mm inches 0,13 .005 0,38 .015 15,9 .625 – – – Fully Released 2,78 10 – Dim. Dwg. Fig. 6 *±0,38 mm ± .015 in. 10BS210 Adjustable differential travel 20 Amps Y 3,10-5,56 11-20 2,78 10 – 0,25 .010 at max. setting 0,04-0,06 .0015-.0025 0,18 .007 at max. setting Dim. Dwg. Fig. 4-A 56 Honeywell Sensing and Control For application help: call 1-800-537-6945. 16,3 .64 Basic Switches Standard BZ/BA Series PIN PLUNGER — SPECIAL CIRCUITRY ORDER GUIDE Recommended For Electrical Data and UL Codes Page 46 BZ-3AT Double-break, low voltage DC applications 15 Amps T 4,45-7,23 16-26 1,11 4 0,76 .030 0,13 .005 0,051-0,13 .002-.005 15,9 .625 BZ-2AW80T As above, with 2.5 inch lever 15 Amps T 0,90 3.25 0,14 .25 – – 5,56 .219 0,51 2.54 19,05±0,76 .750±.030 BZ-2AW82T As above, with 1.9 inch roller lever 15 Amps T 1,25 4.5 0,21 .75 – – 3.96 .156 0,38-1,91 .015-.075 30,18±0,76 1.188±.030 BZ-2AW822T As above, with 1.05 inch roller lever 15 Amps T 2,36 8.5 0,42 1.5 – – 2,39 .094 0,20-2,39 .008-.030 30,18±0,76 1.188±.030 BA-3ST Double-break, low voltage DC applications 25 Amps M 7,23-10,6 26-38 2,78 10 1,65 .065 0,25 .010 0,18-0,38 .007-.015 16,3 .640 BZ-3YT (MS25383-1) MIL-S-8805 application requirements. (split contact) 5 Amps U 4,45-7,23 16-26 1,11 4 0,76 .030 0,13 .005 0,025-0,1 .001-.004 15,9 .625 BZ-3YWT80 As above, with 2.50 inch lever 5 Amps U 0,97 3.5 0,14 .5 – – 5,56 .219 0,51-2,54 .020-.100 19,05±0,76 .750±.030 BZ-3YWT82 As above, with 1.9 inch roller lever 5 Amps U 1,25 4.5 0,21 .75 – – 3,96 .156 0,38-1,91 .015-.075 30,18±0,76 1.188±.030 BZ-3YWT822 As above, with 1.05 inch roller lever 5 Amps U 1,95 7 0,42 1.5 – – 2,39 .094 0,20-1,02 .008-.040 30,19 .188 Catalog Listing Dim. Dwg. Fig. 8 O.F. newtons ounces R.F. min. P.T. max. O.T. min. newtons mm mm ounces inches inches D.T. mm inches O.P.* mm inches Dim. Dwg. Fig. 9 Except where stated * ±0,38 mm ±.015 in. For application help: call 1-800-537-6945. Honeywell Sensing and Control 57 Standard Basic Switches Dim. Dwg. Fig. 10 Basic Switches Standard BZ/BA Series MOUNTING DIMENSIONS (For reference only) PIN PLUNGERS BZ/BM BA/BE Fig. 1 Fig. 2 Fig. 4 Fig. 4-A Fig. 3 PIN PLUNGERS — SPECIAL CIRCUITRY Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Mounting holes accept pins or screws of .139 N (3,53 mm) diameter. 58 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Standard BZ/BA Series MOUNTING DIMENSIONS (For reference only) OVERTRAVEL PLUNGERS Fig. 12 Fig. 13 Fig. 14 Fig. 15 Fig. 16 *Fig. 17 *Fig. 19 *Fig. 20 Standard Basic Switches Fig. 11 *Fig. 18 * Threaded bushings are 15/32-32ns. For application help: call 1-800-537-6945. Honeywell Sensing and Control 59 Basic Switches Standard BZ/BA Series MOUNTING DIMENSIONS (For reference only) STRAIGHT LEVERS Fig. 21 Fig. 22 Fig. 23 Fig. 24 Fig. 25 Fig. 26 FLEXIBLE LEAF ACTUATOR Fig. 33 60 Honeywell Sensing and Control Fig. 34 For application help: call 1-800-537-6945. Basic Switches Standard BZ/BA Series MOUNTING DIMENSIONS ROLLER LEVERS Fig. 28 Fig. 29 Fig. 30 Fig. 31 Fig. 32 FLEXIBLE ROLLER LEAF Mounting holes accept pins or screws of .139N (3,53 mm) diameter. Fig. 35 For application help: call 1-800-537-6945. Fig. 36 Honeywell Sensing and Control 61 Standard Basic Switches Fig. 27 Basic Switches Auxiliary Actuators Standard Basic FEATURES 1 Additional overtravel 1 Quick, easy installation 1 Corrosion resistance 1 MIL-S-8805 listed units NOTE: Switches shown are not included with the actuator. All actuators are for use with pin plunger types only except catalog listing JR. GENERAL INFORMATION Auxiliary actuators adapt the plungertype standard basic switches to many application needs. Auxiliary actuators minimize the need for a large inventory of switch types. Actuators and switches are sold as separate items and must be ordered separately. Mounting hardware is furnished with the actuator. Characteristics: O.T. — Overtravel; O.P. — Operating Position; F.P. — Free Position. ORDER GUIDE Description Catalog Listing Use Only With O.T. min. mm inches O.P.* mm inches F.P. max. mm inches Roller lever for ‘‘S’’ plunger type BZ and DT switches only. Permits cam operation. JR BZ DT 11.1 .437 44,45±3,18 1.75±.125 Adjustable roller lever. Tang on top of actuator can be bent to adjust O.P. and F.P. AD5721R (8805/59) AN3169-1 BZ BM 11,1 .437 approx. 31,75-41,15 1.25-1.62 39,6-43,7 1.56-1.72 ADA3721R BA BE 9,53 .375 approx. 40,48 1.594 approx. 43,03 1.812 ADD3721R DT MT 9,53 .375 approx. 39,6 1.562 approx. 46,03 1.812 MC2711 (8805/59) AN3168-2 BZ BM 4,78 .188 27,79 .188 29,4 1.156 MCA2711 BA BE 3,96 .156 28,17 1.109 30,18 1.188 MCD2711 DT MT 3,58 .141 27,79 1.094 30,18 1.188 Fig. 1 Fig. 2 Straight plunger. Panel mount. Fig. 3 Dimensions shown are for reference only. 62 Honeywell 1 MICRO SWITCH Sensing and Control Except where stated * ±1,14 mm ±.045 in. For application help: call 1-800-537-6945. Basic Switches Auxiliary Actuators Standard Basics ORDER GUIDE Description Fig. 4 Sealed straight plunger. Panel mount. Elastomer seal boot keeps out liquid splash and dirt. Furnished unassembled. Fig. 5 Cross roller plunger. Panel mount. Roller perpendicular to long axis of the switch. Fig. 7 High overtravel plunger. Panel mount. Use O.T. min. Only mm With Inches O.P.* mm Inches F.P. max. mm Inches MC2711H BZ BM 4,78 .188 28,98 1.141 29,4 1.156 MCA2711H BA BE 4,37 .172 27,38±0,76 1.078±.030 29,56 1.156 MCD2711H DT MT 3.58 .141 27,79 1.094 30,18 1.188 MD3211Q BZ BM 3,18 .125 approx. 35,7 1.406 37,69 1.484 MDA3711Q BA BE 3,18 .125 36,12 1.422 37,69 1.484 MD3211Q DT MT 3,18 .125 35,7 1.406 37,69 1.484 MD3211Q1 BZ BM 3,18 .125 approx. 35,7 1.406 37,69 1.484 MDA3711Q1 BA BE 3,18 .125 36,12 1.422 37,69 1.484 MD3211Q1 DT MT 3,18 .125 35,7 1.406 37,69 1.484 MC7711 (8805/58) AN3167-1 BZ BM 20,62 .812 69,1 2.719 70,64 2.781 MCA7711 BA BE 19,84 .781 69,44 2.734 71,42 2.812 MCD7711 DT MT 18,26 .719 69,1 2.719 71,42 2.812 Except where stated* ±1,14 mm ±.045 in. For application help: call 1-800-537-6945. Honeywell nsing and Control 63 Standard Basic Switches Fig. 6 Roller plunger. Panel mount. Roller parallel to long axis of the switch. Catalog Listing Basic Switches Accessories Standard Basics DIE CAST ZINC ENCLOSURES FEATURES 1 Protect switch from physical abuse 1 Protect personnel from contact with exposed terminals 1 Provide rugged mounting means 1 1/2-14NPT internal thread conduit hub Width of opening .74N (18,8 mm) 3PA1 3PA2* *Width of base is 2.125 inches (54 mm) and mounting hole centers are 1.625 inches (41,3 mm) apart. ORDER GUIDE Catalog Listing Description 3PA1 Side mount enclosure–Can be mounted from either side through .140N (3,55mm) dia. holes on 1N (25,4mm) centers. 3PA28 Side mount enclosure–Can be mounted from either side through .140N (3,55mm) dia. holes on 1N (25,4mm) centers. 1/2-14 NPSM internal thread conduit hub. 3PA2 Flange mount enclosure—Switch is first secured in enclosure; two 0.172N (4,37mm) dia. holes in the flange accept #8 machine screws for mounting on 1.625 (41,3mm) centers. 3PA6 Side mount enclosure—For use with actuator Fig. 2 page 58. PLASTIC TERMINAL ENCLOSURES FEATURES 1 Easy to use 1 Screw and solder terminal versions 1 Protect personnel from contact with exposed terminals 5PA1 5PA1 WITH SWITCH ASSEMBLY ORDER GUIDE Catalog Listing 5PA2 Description 5PA1 For solder terminal switches 5PA2 For screw terminal switches 5PA3 For solder or screw terminal switches with auxiliary actuators assembled. Dimensions shown are for reference only. Switches are not included with enclosures. 64 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Accessories Standard Basics ADJUSTABLE MOUNTING BRACKETS FEATURES 1 Sturdy plated steel construction 1 Fast, easy screwdriver adjustment 1 Can be used with all standard basic switches GENERAL INFORMATION The operation point of a basic switch can be regulated up to .080′ (2 mm) by loosening the locking screw, inserting a screwdriver in the adjusting slot, and twisting. ORDER GUIDE Catalog Listing 8MA1 WITH SWITCH ASSEMBLED Description 8MA1 Adjustable mounting bracket, adjustment slot on the left. 8MA2 Adjustable mounting bracket, adjustment slot on the right. MOUNTING DIMENSIONS ‘A’ Dimension for BZ Type 3,6/.14 BA Type 7,8/.31 CONVERSION MOUNTING BRACKET Standard Basic Switches 17MA1-B FEATURES 1 Converts standard basic switches from side to top mount 1 Corrosion resistant 1 Snaps into switch mounting holes— without tools ORDER GUIDE Catalog Listing 17MA1-B Description Conversion mounting bracket. 17MA1-B WITH SWITCH ASSEMBLED MOUNTING DIMENSIONS Switches are not included with bracket. For application help: call 1-800-537-6945. Honeywell Sensing and Control 65 Basic Switches Double-pole Double-throw DT Series FEATURES 1 Two independent single-pole doublethrow circuits on one housing 1 Design permitting several wiring combinations 1 Savings in space and weight 1 Mounting interchangeability with type Z switches 1 Temperature tolerance to +180°F (82°C) 1 UL recognized, CSA certified ELECTRICAL RATING Circuitry Double-pole double-throw DOUBLE-POLE DOUBLE THROW Electrical Data and UL Codes AVAILABLE TERMINALS B6 6-32 UNC H .188 N (No. 5 pan head screws) A7 4-40 UNC H .125 N Screws with lockwashers. Fiberglas insulator isolates terminals and prevents accidental shorting. J 10 amps, 125 or 250 vac; 0.3 amp, 125 vdc; 0.15 amp, 250 vdc. UL Code L59 Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Position. ORDER GUIDE Catalog Listing Description Electrical Data and UL Code O.F. max. newtons ounces R.F. min. newtons ounces P.T. max. mm inches O.T. mm inches D.T. max. min. mm inches O.P.* mm inches DT-2R-A7 MS25008-1 Pin plunger 10 Amps J 3,34-5,56 12-20 0,56 2 1,91 .075 0,13 .005 1,02-1,52 .040-.060 15,6 .615±.015 DT-2RS1-A7 Straight plunger 10 Amps J 3,34-5,56 12-20 0,28 1 1,91 .075 0,51 .020 1,02-1,52 .040-.060 28,2±0,38 1.11±.015 DT-2RV3-A7 Straight lever Reversed lever position 10 Amps J 1,11-1,95 4-7 0,14 0.5 6,86 .270 0,25 .010 2,92-4,83 .115-.190 18,3 .719 DT-2RV-A7 Straight lever 10 Amps J 0,97-1,67 3.5-6 0,28 1 25,4 1 1,57 .062 12,4-19,2 .490-.755 21,8 .859 Dim. Dwg. Fig. 1 Dim. Dwg. Fig. 9 Dim. Dwg. Fig. 3 Except where stated * ±0,76 mm ±.030 in. Dim. Dwg. Fig. 2 66 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Double-pole Double-throw DT Series ORDER GUIDE Catalog Listing Recommended For Electrical O.F. max. Data and newtons UL Codes ounces R.F. min. newtons ounces P.T. max. mm inches O.T. min. mm inches D.T. max. mm inches O.P.* mm inches DT-2RV216-A7 Roller lever (centered steel roller) 10 Amps J 11,1 2.5 lbs. 1,11 4 1,02 .040 0,13 .005 0,51-0,76 .020-.030 31 1.219 DT-2RV22-A7 1.03 inch (26,2mm) roller lever (steel roller) 10 Amps J 2,5-3,89 9-14 0,83 3 – 0,79 .031 4,95-7,75 .195-.305 30,2±0,38 1.188±.015 DT-2RV212-A7 Roller lever Reversed lever position 10 Amps J 2,5-4,17 9-15 0,42 1.5 3,3 .130 0,13 .005 1,27-2,16 .050-.085 29,4 1.156 DT-2RV23-A7 Roller lever Reversed lever position 10 Amps J 1,53-2,64 5.5-9.5 0,21 .75 4,45 .175 0,25 .010 2,16-3,43 .085-.135 29,4 1.156 DT-2RV2-A7 1.90 inch (48,3 mm) roller lever (steel roller) 10 Amps J 1,25-2,09 4.5-7.5 0,42 1.5 — — 1,19 .047 9,27-14,4 .365-.565 31,8 1.250 Dim. Dwg. Fig. 8 Dim. Dwg. Fig. 5 Standard Basic Switches Dim. Dwg. Fig. 7 Dim. Dwg. Fig. 6 Except where stated * ±0,76 mm ±.030 in. Dim. Dwg. Fig. 4 Auxiliary actuators see page 68-69. For application help: call 1-800-537-6945. Honeywell Sensing and Control 67 Basic Switches Double-pole Double-throw DT Series MOUNTING DIMENSIONS (For reference only) 68 PIN PLUNGER STRAIGHT LEVER Fig. 1 Fig. 2 STRAIGHT LEVER ROLLER LEVER Fig. 3 Fig. 4 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Double-pole Double-throw DT Series MOUNTING DIMENSIONS (For reference only) ROLLER LEVER Fig. 5 Fig. 6 ROLLER LEVER ROLLER LEVER Fig. 7 Fig. 8 Standard Basic Switches ROLLER LEVER STRAIGHT PLUNGER Fig. 9 For application help: call 1-800-537-6945. Honeywell Sensing and Control 69 Basic Switches Magnetic Blow-out MT Series FEATURES 1 Arc resistant case 1 Mechanical life of 100,000 operations — 95% survival 1 Temperature tolerance to +180°F (82°C) 1 Mounting interchangeability with Z switches 1 UL recognized GENERAL INFORMATION MT (single-pole double-throw) magnetic blow-out switches are designed to switch high capacity (125 and 250 VDC) systems. An integral magnet around the contact gap protects the contacts by deflecting the arc. Vents between the cover and housing allow the hot gas to escape. These switches are designed for the control of DC motors, solenoids, etc. AVAILABLE TERMINALS Solder (No listing designation) A28 6-32NC H .218N Screws will accept up to #12 wire. ELECTRICAL RATING Electrical Data and UL Codes Circuitry Single-pole double-throw unless otherwise noted in order guide K Rating established with switch non-polarized 10 amps, 125 vac or vdc; 1/4 hp, 125 vac or vdc. UL Code L 168 Non-polarized: 10 amps res. or 1/4 hp, 125 vdc; 3 amps max. res. 250 vdc. Polarized*: 10 amps res. or 1/2 hp, 125 vdc; 3 amps max. res., 250 vdc. *To polarize, connect negative side of line to common terminal. To achieve the same effect, mount switch with brass screws, using a non-magnetic barrier (at least 1⁄4 N thick) between the switch and mounting surface. Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating Position. ORDER GUIDE Catalog Listing MT-4R-A28 Recommended For Pin plunger SPDT Electrical Data and UL Codes O.F. newtons ounces R.F. min. newtons ounces P.T. max. mm inches O.T. min. mm inches D.T. max. mm inches O.P. mm inches 10 Amps K 3,34-5,0 12-18 1,39 5 1,02 .04 0,13 .005 0,1-0,18 .004-.007 15,9±0,38 .625±.015 Dim. Dwg. Fig. 1 70 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Magnetic Blow-out MT Series ORDER GUIDE Catalog Listing Description Electrical O.F. max. Data and newtons UL Codes ounces R.F. min. newtons ounces P.T. max. mm inches O.T. min. mm inches D.T. max. mm inches O.P.* mm inches MT-4RV-A28 Straight lever 10 Amps K 0,56 2 0,14 0.5 12,7 0.5 1,19 .047 2,16 .085 19,1 .750 MT-4RV2-A28 1.90 inch (48,3mm) lever with hardened steel roller 10 Amps K 0,76 2.75 0,07 0.25 8,89 0.35 0,79 .031 1,65 .065 30,2 1.188 MT-4RV22-A28 1.03 inch (26,2mm) lever with hardened steel roller 10 Amps K 1,25 4.5 0,28 1 5,08 .200 0,38 .015 0,89 .035 31,3 1.234 MT-4RL-A28 1.95 inch (49,5mm) flexible leaf 10 Amps K 3,34 12 0,28 1 — 1,52 .060 max. — 19,1 .750 1.82 inch (46,2mm) flexible leaf with hardened steel roller 10 Amps K 3,34 12 0,28 1 — 1,52 .060 max. — 30,2 1.188 Dim. Dwg. Fig. 2 Dim. Dwg. Fig. 3 Dim. Dwg. Fig. 4 Dim. Dwg. Fig. 5 For application help: call 1-800-537-6945. Except where stated * ±0,76 mm ±.030 in. Honeywell Sensing and Control 71 Standard Basic Switches MT-4RL2-A28 Basic Switches Magnetic Blow-out MT Series MOUNTING DIMENSIONS (For reference only) PIN PLUNGER STRAIGHT LEVER Fig. 1 Fig. 2 ROLLER LEVER FLEXIBLE LEAF Fig. 3 Fig. 4 FLEXIBLE ROLLER LEAF Fig. 5 Mounting holes accept pins or screws of .139 N (3,53 mm) diameter. 72 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Double-break 3MN Series FEATURES 1 .080 inch minimum overtravel 1 Power load switching capability up to 15 amperes 1 Motor handling capacity of 1 horsepower at 240 vac. 1 Long mechanical life of 10,000,000 cycles—95% survival 1 Arc resistant plastic 1 More space between terminals to reduce possibility of shorting 1 #8 Terminal screws 1 UL recognized, CSA certified GENERAL INFORMATION 3MN switches are for use with limit or control mechanisms on machine tools, presses or other industrial equipment. These switches provide easy gang mounting. The terminals of double-break switches must be wired to identical voltage sources and the same polarity. The loads should be on the same sides of the lines. ELECTRICAL RATING Electrical Data and UL Codes Circuitry Two-circuit double-break V Motor Control 15 amps, 120, 240, 480 or 600 vac; 1/2 hp, 120 vac; 1 hp, 240 vac; 0.8 amp, 115 vdc; 0.4 amp, 230 vdc. Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel; O.T. – Overtravel; D.T. — Differential Travel; O.P. — Operating Position. ORDER GUIDE Description O.F. newtons ounces R.F. min. newtons ounces P.T. max. mm inches O.T. min. mm inches D.T. mm inches O.P.* max. mm inches 2,16 .085 3MN1 For most applications 15 Amps V 3,34-5,56 12-20 1,67 6 1,52 .060 2,03 .080 0,38-0,63 .015-.025 3MN6 Lower force 15 Amps V 1,95-3,1 7-11 1,11 4 1,52 .060 2,03 .080 0,38-0,63 .015-.025 Dim. Dwg. Fig. 1 MOUNTING DIMENSIONS (For reference only) Fig. 1 For application help: call 1-800-537-6945. Honeywell Sensing and Control 73 2,16 .085 * ±0,38 mm ±.015 in. Standard Basic Switches Catalog Listing Electrical Data and UL Codes Basic Switches Tandem Switch Assemblies 6AS Series FEATURES 1 Variety of actuators 1 Choice of circuitries and electrical ratings 1 Choice of terminations 1 Field adjustable operating point on one or both basic switches GENERAL INFORMATION 6AS switches are two standard basic switches ganged together and actuated by a single actuator. Operating characteristics will depend on the type of individual switches and actuators. ELECTRICAL RATING Electrical Data and UL Codes Circuitry Single-pole double-throw unless otherwise noted in order guide A 15 amps, 125, 250 or 480 vac; 1/8 hp, 125 vac; 1/4 hp, 250 vac; 1/2 amp, 125 vdc; 1/4 amp, 250 vdc. UL Code L96 Single-pole double-throw unless otherwise noted in order guide G 20 amps, 125, 250 or 480 vac; 10 amps, 125 vac ‘‘L’’ (tungsten lamp load); 1 hp, 125 vac; 2 hp, 250 vac; 1/2 amp, 125 vdc; 1/4 amp, 250 vdc. UL Code L23 Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating Position. ORDER GUIDE Catalog Listing 6AS32 6AS54 6AS25 Dim. Dwg. Fig. 1 Description Lever Length Electrical mm Type Data and inches Terminals UL Codes O.F. max. newtons ounces R.F. min. newtons ounces O.T. min. mm inches D.T. max. mm inches O.P.* mm inches Centered lever. Adjustment over both switches. 58,72 2.312 Solder 15 Amps A 2,22 8 0,14 0.5 0,51 .020 2,77 .109 18,29 .720 adj. Short lever. Adjustment over switch D. 20,47 .806 Solder 15 Amps A 3,34 12 0,83 3 0,25 .010 3,96 .156 18,24 .718 max. Centered lever. Adjustment over switch D. 32,26 1.270 A2 20 Amps G 3,89 14 1,11 4 1,02 .040 — 18,67 .735 Unless otherwise noted * ±0,76 mm ±.030 in. 74 Honeywell Sensing and Control For application help: call 1-800-537-6945. Basic Switches Tandem Switch Assemblies 6 AS Series ORDER GUIDE Catalog Listing 6AS13 6AS18 6AS36 6AS35 6AS16 6AS69 6AS112 Dim. Dwg. Fig. 2 6AS5 Dim. Dwg. Fig. 3 Description Lever Length mm Type inches Terminals Electrical Data and UL Codes O.F. max. newtons ounces R.F. min. newtons ounces O.T. min. mm inches D.T. max. mm inches O.P.* mm inches Centered lever. Adjustment over switch D. 30,56 1.203 Solder 15 Amps A 2,22 8 0,14 0.5 0,51 .020 2,77 .109 29,77 1.172 Centered lever. Adjustment over both switches. 30,56 1.203 Solder 15 Amps A 2,22 8 0,14 0.5 0,51 .020 2,77 .109 29,77 1.172 adj. Lever over switch C. Adjustment over switch D. 30,56 1.203 A2 15 Amps A 2,22 8 0,14 0.5 0,51 .020 2,77 .109 29,77 1.172 Lever and adjustment over switch D. 30,56 1.203 A2 15 Amps A 2,22 8 0,14 0.5 0,51 .020 2,77 .109 29,77 1.172 Centered lever. Adjustment over switch D. 30,56 1.203 A2 20 Amps G 3,89 14 1,11 4 1,02 .040 3,96 .156 30,96±1,14 1.219±.045 Centered lever. Adjustment over switch D. 27,25 1.073 T 25 Amps M — — — — 30,96±1,14 1.219±.045 Centered lever. Adjustment over switch D. 30,56 1.203 A2 25 Amps H 3,89 14 1,11 4 1,02 .040 3,96 .156 30,96±1,14 1.219±.045 Centered leaf. No adjustment. Switches operate within .030 N of each other. 38,35 1.51 A2 15 Amps A — — 0,76-1,52 .030-.060 — Unless otherwise noted * ±0,76 mm ±.030 in. STRAIGHT LEVER ROLLER LEVER LEAF Fig. 1 Fig. 2 Fig. 3 Mounting holes accept pins or screws of .139 N (3,53 mm) diameter. For application help: call 1-800-537-6945. Honeywell Sensing and Control 75 Standard Basic Switches MOUNTING DIMENSIONS (For reference only)