HONEYWELL UX10E10C01

Basic Switches
Standard Basic Switches
Sealed/High Temperature Switches
Miniature/Subminiature Switches
Selection
Door Switches
SUBMINIATURE/MINIATURE BASIC SWITCHES
The U Series of subminiature basic switches are our newest line. The US is the
smallest snap-action switch available. The UX and UM are versatile, low cost,
full featured products with ample electrical capacity in a compact package.
SM subminiature basic switches are a versatile collection of small size and
ample electrical capacities, including 11 amp power load handling and 1⁄4 hp
motor load. SX subminiature basic switches are smaller than SM switches,
yet are big in performance and selection. They provide up to 7 amp power
load capacity. V3 miniature basic switches put a 25 amp power load capacity
and a choice of 11 other electrical ratings into a relatively small package with
many choices of actuators, contact materials, and terminal designs. V7 miniature basic switches have electrical ratings up to 15 amps. Both commercial
and European versions are UL recognized and CSA certified. The latter is also
designed to meet all leading European approval agency requirements. TB
miniature basic small double-break units can control 2, 3 or 4 isolated circuits.
Typical Applications . . . . . . . . . . . . . . . . . . . . . . . p. 2
Index by Product Type . . . . . . . . . . . . . . . . . . . . . p. 3
Selection Guides. . . . . . . . . . . . . . . . . . . . . . p. 4 to 7
Catalog Listings/Order Guides . . . . . . . . . p. 8 to 93
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . p. 94
Catalog Listing/Page Number Index . . . . . . . p. 102
STANDARD BASIC SWITCHES
Power load switching and motor handling capacity are among the attractions
of thumb-size BZ/BA standard basic switches. Double-pole double-throw
switching is added by DT switches. Where there’s a need for reliable switching of high capacity systems involving DC motors and solenoids, MT magnetic blow-out switches do the job. The 3MN has double-break switching. 6AS
assemblies have two tandem mounted standard basic switches under a common actuator.
SEALED AND HIGH TEMPERATURE BASIC SWITCHES
Specially adapted basic switches include: SE/XE environment-proof switches which protect subminiature SM/SX basic switches within a sealed housing; HM hermetically sealed switches are interchangeable in operating point
with the SM switches; HS hermetically sealed switches which parallel the size
and mounting scheme of the standard basic switches; and HT high temperature switches for use up to +1000°F.
DOOR SWITCHES
AC, WW and DM switches automatically cut power when a service door or
drawer is opened.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
1
Basic Switches
Subminiature/Miniature
ELECTRICAL DATA AND UL CODES
MINIATURE/SUBMINIATURE BASIC SWITCHES
Most of the switches in this section are UL recognized and CSA
certified. The current and voltage values shown are based on
test conditions specified by these agencies. Electrical life of the
switch is influenced by each application condition as well as by
voltage and current.
Circuitry
Circuitry
S UL rating:
4 amps, 250 vac.
Single-pole
double-throw
T UL/CSA rating:
11 amps and 1/3 hp, 125, 250, or 277
vac;
1/2 amp, 125 vdc; 1/4 amp, 250 vdc;
4 amps, 125 vac ‘‘L’’ (lamp load).
Electrical Data
Single-pole
double-throw
A 5 amps res., 3 amps ind., (sea level),
4 amps res., 2 amps ind., (50,000
feet), 28 vdc
5 amps res. or ind. 115 vac, 60 Hz.
UL/CSA rating: 5 amps, 250 vac.
Single-pole
double-throw
B 7 amps res., 4 amps ind., (sea level),
7 amps res., 2.5 amps ind., (50,000
feet), 28 vdc.
UL/CSA rating: 7 amps, 250 vac.
Single-pole
double-throw
C 3.5 amps res., 2 amps ind., (sea level),
3.5 amps res., 1.5 amps ind., (50,000
feet), 28 vdc.
UL rating: 7 amps, 250 vac.
Single-pole
double-throw
Electrical Data
Single-pole
double-throw
TT UL/CSA rating:
10 amps and 1/3 hp, 125 or 250 vac;
1/2 amp, 125 vdc; 1/4 amp, 250 vdc;
4 amps, 125 vac ‘‘L’’ (lamp load).
Single-pole
double-throw
unless
otherwise
noted in
order guide
UU 10 amps res., 10 amps ind., (sea
level),
6 amps ind. (50,000 feet), 6 amps
motor load, 30 vdc.
D 1 amp res., 0.5 amp ind., (sea level
and 50,000 feet), 28 vdc.
UL/CSA rating: 1 amp, 125 vac.
Single-pole
double-throw
VV UL/CSA rating:
3 amps-125, 250, 277 vac;
1/10 hp-250 vac
Single-pole
double-throw
E 3 amps res., 2 amps ind., (sea level),
28 vdc.
UL rating: 3 amps, 250 vac.
Single-pole
double-throw
Single-pole
double-throw
F 7 amps res., 4 amps ind., 2.5 amps
lamp load, (sea level),
4 amps res., 2.5 amps ind., 2.5 amps
lamp load, (50,000 feet), 28 vdc.
7 amps res., 7 amps ind., 2 amps lamp
load, 115 vac, 60 Hz (sea level).
V UL/CSA rating:
10 amps and 1/4 hp, 125 or 250 vac;
1/2 amp, 125 vdc; 1/4 amp, 250 vdc;
3 amps, 125 vac ‘‘L’’ (lamp load).
Single-pole
double-throw
W 10 amps, 250 vac or 28 vdc;
1/2 amp, 125 vdc; 1/4 amp, 250 vdc.
Single-pole
double-throw
X UL rating:
1 amp, 125 vac.
Y 10 amps and 1/3 hp, 125 or 250 vac;
4 amps, 125 vac ‘‘L’’ (lamp load).
Single-pole
double-throw
G 2 amps res., lamp ind., (sea level)
28 vdc.
Single-pole
double-throw
Single-pole
double-throw
H .010 amp res. and ind., (sea level).
28 vdc.
UL/CSA rating: 1 amp, 125 vac.
Single-pole
double-throw
Single-pole
double-throw
I 7 amps res., 4 amps ind., (sea level),
28 vdc.
Two-circuit
double-break
Single-pole
double-throw
J 5 amps res., 3 amps ind., (sea level),
5 amps res., 2.5 amps ind.,
(50,000 feet), 28 vdc.
UL rating: 5 amps, 250 vac.
Four-circuit
double-break
Single-pole
double-throw
K UL rating:
5 amps, 125 or 250 vac.
Single-pole
double-throw
L 1 amp res., 1/2 amp ind.,
(sea level) 28 vdc.
Single-pole
double-throw
M UL rating:
11 amps and 1/4 hp, 125 or 250 vac.
Single-pole
double-throw
N 1 amp res., 0.5 amp ind., 30 vdc.
UL rating: 1 amp, 125 vac.
Single-pole
double-throw
P 1 amp res., 30 vdc.
UL rating: .1 amp, 125 vac.
Single-pole
double-throw
R 5 amps res., 3 amps ind., 2.4 amps
lamp load (sea level),
5 amps res., 2.5 amps ind., 2.4 amps
lamp load, (50,000 feet), 28 vdc.
5 amps res., 5 amps ind., 1.5 amps
lamp load, 115 vac. 60 Hz (sea level)
20
Honeywell Sensing and Control
U UL/CSA rating:
15.1 amps and 1/2 hp, 125 or 250 vac.
1/2 amp, 125 vdc; 1/4 amp, 250 vdc;
5 amps, 120 vac ‘‘L’’ (lamp load).
YY UL/CSA rating:
5 amps-125, 250, 277 vac
1/10 hp-250 vac
Z 10 amps, 125 or 250 vac, or 30 vdc.
UL/CSA rating:
10 amps, 125 or 250 vac; 1/2 hp, 125
vac.
Single-pole
double-throw
ZZ UL rating:
5 amps and 1/10 hp.
125 or 250 vac.
Single-pole
double-throw
AA UL rating:
20 amps, 277 vac.
1 hp, 125 vac; 2 hp, 250 vac.
Single-pole
double-throw
BB UL rating:
25 amps, 277 vac.
1 hp, 125 vac; 2 hp, 250 vac.
For application help: call 1-800-537-6945.
Basic Switches
Standard
ELECTRICAL DATA AND UL CODES STANDARD BASIC
SWITCHES
Most of the switches in this section are UL recognized and CSA
certified. The current and voltage values shown are based on
test conditions specified by these agencies. Electrical life of the
switch is influenced by each application condition as well as by
voltage and current. For application assistance contact the 800
number.
Circuitry
Double-pole
double-throw
J 10 amps, 125 or 250 vac;
0.3 amp, 125 vdc; 0.15 amp,
250 vdc.
UL Code L59
Single-pole
double-throw
unless
otherwise noted
in order guide
K Rating established with
switch non-polarized
10 amps, 125 vac or vdc;
1
⁄4 hp, 125 vac or vdc.
UL Code L 168
Non-polarized:
10 amps res. or 1⁄4 hp, 125 vdc;
3 amps max. res. 250 vdc.
Polarized*:
10 amps res. or 1⁄2 hp, 125 vdc;
3 amps max. res., 250 vdc.
Electrical Data and
UL Codes
Circuitry
Electrical Data and
UL Codes
Single-pole
double-throw
unless
otherwise noted
in order guide
A 15 amps, 125, 250 or 480 vac;
1
⁄8 hp, 125 vac; 1⁄4 hp, 250 vac;
1
⁄2 amp, 125 vdc; 1⁄4 amp,
250 vdc.
UL Code L96
Single-pole
double-throw
unless
otherwise noted
in order guide
B 5 amps, 125, 250 or 480 vac;
1
⁄2 amp, 125 vdc; 1⁄4 amp, 250 vdc.
UL Code L35
Single-pole
double-throw
unless
otherwise noted
in order guide
C 10 amps, 125, 250 or 480 vac;
UL Code L8
Single-pole
double-throw
R 10 amps, 125 or 250 vac;
1
⁄3 hp, 125 vac; 3⁄4 hp, 250 vac;
1
⁄2 amp, 125 vdc; 1⁄4 amp,
250 vdc.
UL Code L115
Single-pole
double-throw
unless
otherwise noted
in order guide
D 15 amps, 125, 250 or 480 vac;
1
⁄8 hp, 125 vac; 1⁄4 hp, 250 vac.
UL Code L103
Single-pole
double-throw
S 10 amps, 125 or 250 vac;
1
⁄3 hp, 125 or 250 vac.
UL Code L93
Single-pole
double-throw
unless
otherwise noted
in order guide
E 15 amps, 125, 250 or 480 vac;
1
⁄4 hp, 125 vac, 1⁄2 hp, 250 vac;
1
⁄2 amp, 125 vdc; 1⁄4 amp, 250 vdc.
UL Code L67
Single-pole
double-throw
unless
otherwise noted
in order guide
F 22 amps, 125, 250 or 480 vac;
1
⁄2 hp, 125 vac, 1 hp, 250 vac.
UL Code L161
Single-pole
double-throw
unless
otherwise noted
in order guide
G 20 amps, 125, 250 or 480 vac;
10 amps, 125 vac ‘‘L’’ (tungsten
lamp load);
1 hp, 125 vac; 2 hp, 250 vac;
1
⁄2 amp, 125 vdc; 1⁄4 amp,
250 vdc.
UL Code L23
Single-pole
double-throw
unless
otherwise noted
in order guide
H Motor Control
25 amps, 125, 250 or 480 vac;
1 hp, 125 vac; 2 hp, 250 vac;
Pilot Duty—750 VA, 125, 250,
or 277 vac.
Single-pole
double-throw
unless
otherwise noted
in order guide
I
46
10 amps, 125, 250 or 480 vac;
1
⁄8 hp, 125 vac; 1⁄4 hp, 250 vac;
UL Code L95
Honeywell Sensing and Control
*To polarize, connect negative side of line to common terminal. To
achieve the same effect, mount switch with brass screws, using a
non-magnetic barrier (at least 1⁄4 N thick) between the switch and
mounting surface.
Two-circuit
double-break
Single-pole
double-throw
Two-circuit
double-break
Single-pole
double-throw
Two-circuit
double-break
Single-pole
single-throw
(N.C.)
Single-pole
double-throw
Single-pole
double-throw
M 25 amps, 125, 250 or 480 vac;
3
⁄4 hp, 125 vac; 11⁄4 amp, 250 vac.
1 amp, 125 vdc; 1⁄2 amp, 250 vdc.
UL Code L58
P 1 amp, 125 VAC
UL Code L22
T 15 amps, 125, 250 or 480 vac;
1 amp, 125 vdc; 1⁄2 amp, 250 vdc;
1
⁄4 hp, 125 vac; 1⁄2 hp, 250 vac
UL Code L73
U 5 amps, 250 vac.
UL Code L4
V Motor Control
15 amps, 120, 240, 480 or 600
vac;
1
⁄2 hp, 120 vac; 1 hp, 240 vac;
0.8 amp, 115 vdc; 0.4 amp,
230 vdc.
W 20 amps, 125, 250 or 277 vac;
3
⁄4 hp, 125 vac; 1⁄2 hp, 250 vac
UL Code L178B
X 15 amps, 125, 250 or 480 vac;
2 amps, 600 vac;
1
⁄8 hp, 125 vac; 1⁄4 hp, 250 vac;
1
⁄2 amp, 125 vdc; 1⁄4 amp,
250 vdc.
UL Code L74
Y 20 amps, 125, 250 or 480 vac;
3
⁄4 hp, 125 vac; 11⁄2 hp, 250 vac; UL
Code L17
For application help: call 1-800-537-6945.
Basic Switches
Operating Characteristics
ELECTROMECHANICAL SWITCHES
Definitions below explain the meaning of
operating characteristics. Characteristics
shown in tables throughout catalog were
chosen as most significant. They are taken at normal room temperature and humidity. These may vary as temperature
and humidity conditions differ. Sketches
show how characteristics are measured
for in-line plunger actuation.
Linear dimensions for in-line actuation
are from top of plunger to a reference line,
usually the center of the mounting holes.
Differential Travel (D.T.)—Plunger or actuator travel from point where contacts
‘‘snap-over’’ to point where they ‘‘snapback.’’
Free Position (F.P.)—Position of switch
plunger or actuator when no external
force is applied (other than gravity).
Full Overtravel Force—Force required
to attain full overtravel of actuator.
Operating Position (O.P.)—Position of
switch plunger or actuator at which point
contacts snap from normal to operated
position. Note that in the case of flexible or
adjustable actuators, the operating position is measured from the end of the lever
or its maximum length. Location of operating position measurement shown on
mounting dimension drawings.
Operating Force (O.F.)—Amount of
force applied to switch plunger or actuator to cause contact ‘‘snap-over.’’ Note in
the case of adjustable actuators, the force
is measured from the maximum length
position of the lever.
Overtravel (O.T.)—Plunger or actuator
travel safely available beyond operating
position.
Pretravel (P.T.)—Distance or angle traveled in moving plunger or actuator from
free position to operating position.
Release Force (R.F.)—Amount of force
still applied to switch plunger or actuator
at moment contacts snap from operated
position to unoperated position.
Total Travel (T.T.)—Distance from actuator free position to overtravel limit position.
IN-LINE PLUNGER ACTUATION
94
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Operating Characteristics
FULL LOAD AND LOCKED ROTOR CURRENTS FOR SINGLE PHASE AND DC MOTORS
Alternating Current
115 Volts
Direct Current
230 Volts
115 Volts
HP
Full
Load
Locked
Rotor
Full
Load
Locked
Rotor
Full
Load
Locked
Rotor
2
11⁄2
1
3
⁄4
1
⁄2
1
⁄3
1
⁄4
1
⁄6
1
⁄8
1
⁄10
1
⁄20
24.0
20.0
16.0
13.8
9.8
7.2
5.8
4.4
3.8
3.0
1.5
144.0
120.0
96.0
82.8
58.8
43.2
34.8
26.4
22.8
18.0
9.0
12.0
10.0
8.0
6.9
4.9
3.6
2.9
2.2
1.9
1.5
—
72.0
60.0
48.0
41.4
29.4
21.6
17.4
13.2
11.4
9.0
—
17.0
13.2
9.6
7.4
5.4
3.8
3.0
2.4
2.2
2.0
—
170.0
132.0
96.0
74.0
54.0
38.0
30.0
24.0
22.0
20.0
—
230 Volts
Full
Load
8.5
6.6
4.8
3.7
2.7
1.9
1.5
1.2
1.1
1.0
—
Locked
Rotor
85.0
66.0
48.0
37.0
27.0
19.0
15.0
12.0
11.0
10.0
—
Reference/Index
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
95
Basic Switches
B Type Switches Performance Information
ELECTRICAL DATA CHART
Catalog
Listing
(contact
gap)
BZ-3YT*
.036 in.
0,91 mm
BZ-3YT*
.036 in.
0,91 mm
BM-2R
.020 in.
0,50 mm
BM-2R
.020 in.
0,50 mm
BA-2R
.020 in.
0,50 mm
BA-2R
.020 in.
0,50 mm
BE-2R
.020 in.
0,50 mm
BE-2R
.020 in.
0,50 mm
BZ-R
.006 in.
0,15 mm
BZ-1R
.010 in.
0,25 mm
BZ-1R
.010 in.
0,25 mm
Amperes
Current
Inrush
Carrying
Capacity
N.C.
Resistive Ckt.
Max.1
N.O.
Ckt.
Motor
N.C.
Ckt.
N.O.
Ckt.
Lamp
N.C.
Ckt.
N.O.
Ckt.
Inductive2
Sea
50,000
Level
Feet
VDC
8
14
30
125
250
5
5
5
5
5
10
10
10
1
0.6
30
30
30
10
6
15
15
15
10
6
5
5
5
2
1.2
2.5
2.5
2.5
2
1.2
3
3
3
1
0.6
1.5
1.5
1.5
1
0.6
10
10
10
0.6
0.4
10
10
5
0.4
0.3
VAC
120
240
277
5
5
5
5
5
5
30
30
30
15
15
15
5
5
5
2.5
2.5
2.5
3
3
3
1.5
1.5
1.5
5
5
5
5
5
5
VDC
8
14
30
125
230
22
22
22
22
22
15
15
2
0.4
0.2
30
30
30
4
2
15
15
15
4
2
5
5
5
0.8
0.4
2.5
2.5
2.5
0.4
0.2
3
3
3
0.4
0.2
1.5
1.5
1.5
0.4
0.2
8
5
1
.03
.02
7
5
1
.02
.01
VAC
125
250
277
460
22
22
22
22
22
22
22
22
35
35
35
35
20
20
20
20
5.8
5.8
5.8
5.8
3.4
3.4
3.4
3.4
3.5
3.5
3.5
3.5
2.0
2.0
2.0
2.0
22
22
22
22
22
22
22
22
VDC
8
14
30
125
230
20
20
20
20
20
20
20
5
0.5
0.25
30
30
30
4
2
15
15
15
4
2
5
5
5
0.8
0.4
2.5
2.5
2.5
0.4
0.2
3
3
3
0.4
0.2
1.5
1.5
1.5
0.4
0.2
15
10
5
.05
.03
15
8
2
.03
.02
VAC
120
240
277
460
20
20
20
20
20
20
20
20
75
75
75
75
75
75
75
75
12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
20
20
20
20
20
20
20
20
VDC
8
14
30
125
250
25
25
25
25
25
25
25
5
0.5
0.25
30
30
30
4
2
15
15
15
4
2
5
5
5
0.8
0.4
2.5
2.5
2.5
0.8
0.4
3
3
3
0.4
0.2
1.5
1.5
1.5
0.4
0.2
15
10
5
.05
.03
15
8
2
.03
.02
VAC
120
240
277
460
25
25
25
25
25
25
25
25
96
96
96
96
96
96
96
96
16
16
16
16
16
16
16
16
10
10
10
10
10
10
10
10
25
25
25
25
VAC
125
250
277
15
15
15
15
15
15
30
30
30
15
15
15
5
5
5
2.5
2.5
2.5
3
3
3
1.5
1.5
1.5
15
15
15
15
15
15
VDC
8
14
30
125
230
15
15
15
15
15
15
15
2
0.4
0.2
30
30
30
4
2
15
15
15
4
2
5
5
5
0.8
0.4
2.5
2.5
2.5
0.8
0.4
3
3
3
0.4
0.2
1.5
1.5
1.5
0.4
0.2
8
5
1
0.03
0.02
7
5
1
0.01
0.01
VAC
125
250
277
460
15
15
15
15
15
15
15
15
30
30
30
30
15
15
15
15
5
5
5
5
2.5
2.5
2.5
2.5
3
3
3
3
1.5
1.5
1.5
1.5
15
15
15
15
15
15
15
15
Voltage
*Ampere levels for BZ-3YT applicable only if common terminal is not used and switch is used as a shorting bar switch.
96
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
B Type Switches Performance Information
ELECTRICAL DATA CHART, cont.
Catalog
Listing
(contact
gap)
BZ-2R
.020 in.
0.50 mm
BZ-2R
.020 in.
0,50 mm
BZ-3R
.036 in.
0,91 mm
BZ-3R
.036 in.
0,91 mm
BZ-7R
.070 in.
1,78 mm
BZ-7R
.070 in.
1,78 mm
Amperes
Current
Inrush
Carrying
Capacity
N.C.
Resistive Ckt.
Max.1
N.O.
Ckt.
Motor
N.C.
Ckt.
N.O.
Ckt.
Lamp
N.C.
Ckt.
N.O.
Ckt.
Inductive2
Sea
50,000
Level
Feet
VDC
8
14
30
125
230
15
15
15
15
15
15
15
6
0.4
0.2
30
30
30
4
2
15
15
15
4
2
5
5
5
0.8
0.4
2.5
2.5
2.5
0.8
0.4
3
3
3
0.4
0.2
1.5
1.5
1.5
0.4
0.2
15
10
5
0.05
0.03
15
8
2
0.03
0.02
VAC
125
250
277
460
15
15
15
15
15
15
15
15
30
30
30
30
15
15
15
15
5
5
5
5
2.5
2.5
2.5
2.5
3
3
3
3
1.5
1.5
1.5
1.5
15
15
15
15
15
15
15
15
VDC
8
14
30
125
250
15
15
15
15
15
15
15
10
0.6
0.3
30
30
30
6
3
15
15
15
6
3
5
5
5
1.2
0.6
2.5
2.5
2.5
1.2
0.6
3
3
3
0.6
0.3
1.5
1.5
1.5
0.6
0.3
15
15
10
0.1
0.05
15
15
5
0.05
0.03
VAC
125
250
277
460
15
15
15
15
15
15
15
15
30
30
30
30
15
15
15
15
5
5
5
4
2.5
2.5
2.5
2.5
3
3
3
3
1.5
1.5
1.5
1.5
15
15
15
15
15
15
15
15
VDC
8
14
30
125
250
30
15
15
15
15
15
15
15
0.75
0.3
15
30
30
7.5
3
5
15
15
7.5
3
2.5
5
5
1.5
0.6
3
2.5
2.5
1.5
0.6
1.5
3
3
0.75
0.3
15
1.5
1.5
0.75
0.3
15
15
10
0.4
0.2
—
15
7.5
0.2
0.1
VAC
120
240
277
460
15
15
15
15
15
15
15
15
30
30
30
30
15
15
15
15
5
5
5
5
2.5
2.5
2.5
2.5
3
3
3
3
1.5
1.5
1.5
1.5
15
15
15
15
15
15
15
15
Voltage
1 For a 86− F (30−C) max. temperature rise at terminals, not opening or closing the load (at sea level).
2 Data established with a 75% power factor on AC loads.
TEST CONDITIONS
Switch contact life is affected by electrical conditions and other
factors, such as: temperature, humidity, airborne contamination, vibration, amount and rate of plunger travel, and cycling
Temperature:
Humidity:
AC Cycle Rate:
DC Cycle Rate:
On-off Time:
Power Factor (AC):
Inductance (DC):
Circuit Loading:
Travel Plunger:
Actuation:
Overtravel Force:
rate. Our Evaluation Laboratory tests are conducted using procedures and practices common to UL and Military Specifications. The following conditions generally apply.
Room Ambient (70 −F, 21−C).
Room Ambient (50%).
60 operations/minute.
20 operations/minute.
Equal and compatible with above cycling rates.
Approximately 75%.
MIL-I-81023 Inductor.
One throw only on a SPDT switch during any test procedure. Both throws are evaluated separately.
Full switch travel is used.
Linear motion.
1 to 3 lbs. from spring-loaded actuators.
For application help: call 1-800-537-6945.
been extrapolated. For specific switch selection, customers
should evaluate switches under actual application conditions
or by simulating all application conditions and requirements.
The information set forth cannot substitute for the customer’s
own product evaulation. It should never be published by a customer as a rating on their product.
Honeywell Sensing and Control
97
Reference/Index
MICRO SWITCH believes that with the following voltage and
current values and under the test conditions set forth below
switch life of 100,000 closures, 95% survival can be expected. It
is a starting point for user evaluation and provides guidelines
on the switches identified. Because of the numerous electrical
conditions listed, not every current and voltage level has actually been tested on every switch and certain figures have
Basic Switches
Definitions of Terms
Actuator – Mechanism of the switch or
switch enclosure which operates the contacts.
Auxiliary Actuator – A mechanism, sold
separately, to provide basic switches with
easier means of operation and adjustment and adapt switches to different operating motions by supplying supplemental overtravel.
Double Break Contacts – (Twin break).
This breaks the circuit in two places. Referred to as form Z circuitry also.
Precision Snap-Acting Switch – An
electromechanical switch having predetermined and accurately controlled characteristics, and having a spring loaded
quick make and break contact action.
Form Z
Basic Switch – A self-contained switching unit. It can be used alone, gangmounted, built into assemblies or enclosed in metal housings.
Double-Pole Double-Throw (DPDT) –
Switches which make and break two separate circuits. This circuit provides a normally open and normally closed contact
for each pole.
Bifurcated Contacts – A movable contact, generally gold plated, which is
forked to provide two contact mating surfaces in a parallel, for more reliable contact.
Enclosed Switch – A basic switch unit
(contact block) enclosed in a durable
metal housing. The enclosure protects
the switching unit, provides mounting
means, and fitting for conduit connection.
Break – To open an electrical circuit.
Environment-Proof Switch – A switch
which is completely sealed to ensure constant operating characteristics. Sealing
normally includes an ‘‘O’’ ring on actuator
shaft and fused glass-to-metal terminal
seals or complete potting and an elastomer plunger-case seal.
Break Distance – The minimum open
gap distance between stationary and
movable objects.
Characteristics – This term is used by
MICRO SWITCH in a restricted sense and
refers only to switch operating characteristics such as pretravel, operating force,
etc.
Circuit – The contact arrangement with
switch actuator and contacts in their normal position.
Dead break – Exists in all mechanical
switches. Definition: When the switch
plunger is being depressed, dead break
is non-contact immediately before the
plunger reaches the operating point.
When the switch plunger is being released, dead break is non-contact immediately before the plunger reaches the release point. Dead break is expressed in
distance of plunger travel during which
the non-contact occurs. Manufacturing
specifications for most BZ/BA basic
switches allow a maximum dead break of
0.00005 in. (0,001 mm) measured at the
switch plunger. Switches are evaluated
while moving the plunger with the switch
installed in a 10 VDC, 0.100 ampere circuit. This specifiction does not apply to
switches that have been in service or have
not received proper handling or storage.
For applications sensitive to dead break,
call Freeport for information on applicable electrical and mechanical conditions.
Dead make – When the switch plunger is
being depressed, dead make is non-contact immediately after the plunger reaches the release point. Dead make is expressed as the distance of plunger travel
during which the non-contact occurs.
Non contact is a failure of open contacts
to close (that is, the switch resistance exceeds the specified value) within the
specified range of plunger positions. If a
plunger position is specified with respect
to time, a non-contact is a contact miss.
98
Honeywell Sensing and Control
Normally Open Contacts (N.O.) – Provide a normally open circuit when actuator is in free position.
Explosion-Proof Switch – A UL listed
switch capable of withstanding an internal explosion of a specified gas without
igniting surrounding gases.
Hermetically Sealed Switch – A switch
completely sealed to provide constant
operating characteristics. All junctures
made with metal-to-metal or glass-tometal fusion.
Magnetic Blow-Out Switch – Contains a
small permanent magnet which provides
a means of switching high d-c loads. The
magnet deflects arc to quench it.
Maintained Contact Switch – Designed
for applications requiring sustained contact after plunger has been released, but
with provision for resetting.
Projection Contacts – A design in which
one or more truncated projections are arranged on the stationary contacts. When
closed on the smooth, spherical surface
of the opposing contact this configuration
tends to break thru oxides and other film
contaminants to avoid the particulate
contaminants. Used with silver contacts,
this design can be a useful substitute for
the more expensive gold or gold alloy
contact material.
Pulse Switch – Provides a single pulse of
current for each cycle of operation.
Quick Connect Terminal – A plug-in type
terminal designed for quick switch wiring.
Repeatability – Ability of a switch to repeat its characteristics precisely from one
operation to the next operation.
Single-Pole Double-Throw (SPDT) –
Switch which may either make or break a
circuit, depending on how it is wired. Also
referred to as form C circuitry.
Form C
Single-Pole Single-Throw (SPST) –
Switch with only one moving and one stationary contact. Available either normally
open (N.O.) also referred to as form A circuitry; or normally closed (N.C.) also referred to as form B circuitry.
Make – To close or establish an electrical
circuit.
Momentary Switch – A switch with contacts that return from operated condition
to normal condition when actuating force
is removed. Unless otherwise stated, all
switches in this catalog are momentary.
Mounting Dimensions – All dimensions
on the mounting dimension drawings in
this catalog are subject to change without
notice. Request current drawings from
the nearest MICRO SWITCH Sales Office
or write to Freeport.
Normally Closed Contacts (N.C.) – Provide a normally closed circuit when actuator is in free position.
Form A
Form B
Terminal Enclosure – A housing that fits
over switch terminals to protect against
electrical shock and accidental shorting,
and facilitate wiring.
Two Circuit Switch – In one position,
moving contacts complete one circuit, in
the other position, contacts complete another separate circuit.
For application help: call 1-800-537-6945.
Basic Switches
Subminiature
US Series
PC Terminal Version
C
NO
NC
FEATURES
1 MICRO SWITCH’S smallest snap-action switch
1 Choice of low energy or power duty electrical ratings
1 Variety of integral actuators
1 Temperature Range: −25° to +80°C (−13° to +176°F)
1 Weight: 0.2 grams (.007 oz.) – PC terminal type
0.3 grams (.011 oz.) – solder terminal type
1 Form C single-pole double-throw (SPDT) circuitry
ELECTRICAL RATINGS
Voltage
Resistive Load
Gold Contacts
US10 Type
Silver Contacts
US20 Type
30 VDC
125 VAC
0.1 A
0.1 A
0.5 A
0.1 A
ORDER GUIDE SOLDER TERMINALS
Contact Type
Actuator
Gold, 0.1 Amp
A pin plunger
O.F. max.
grams
oz.
Solder
R.F. min.
g
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T. max.
mm
inches
O.P
mm
inches
100
3.527
US10D10A00
10
.353
0,3
.012
0,1
.004
0,1
.004
5,4 ± 0,15
.213 ± .006
C flat lever
25
.88
US10D10C00
2,0
.071
2,4
.094
0,4
.016
0,7
.028
6,4 ± 0,6
.252 ± .024
E simulated
roller lever
30
1.058
US10D10E00
2,0
.071
2,2
.087
0,3
.012
0,7
.028
6,7 ± 0,5
.264 ± .020
100
3.527
US20D10A00
10
.353
0,3
.012
0,1
.004
0,1
.004
5,4 ± 0,15
.213 ± .006
C flat lever
25
.88
US20D10C00
2,0
.071
2,4
.094
0,4
.016
0,7
.028
6,4 ± 0,6
.252 ± .024
E simulated
roller lever
30
1.058
US20D10E00
2,0
.071
2,2
.087
0,3
.012
0,7
.028
6,7 ± 0,5
.264 ± .020
Silver, 0.5 Amp A pin plunger
ORDER GUIDE PC STRAIGHT TERMINALS
O.F. max.
grams
oz.
PC
Straight
Cross-Line
R.F. min.
g
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T. max.
mm
inches
O.P
mm
inches
100
3.527
US10D20A00
10
.353
0,3
.012
0,1
.004
0,1
.004
4,8 ± 0,15
.189 ± .006
C flat lever
25
.88
US10D20C00
1,0
.035
2,4
.094
0,4
.016
0,7
.028
5,8 ± 0,7
.228 ± .028
E simulated
roller lever
30
1.058
US10D20E00
1,0
.035
2,2
.087
0,3
.012
0,7
.028
6,1 ± 0,7
.240 ± .028
100
3.527
US20D20A00
10
.353
0,3
.012
0,1
.004
0,1
.004
4,8 ± 0,15
.189 ± .006
C flat lever
25
.88
US20D20C00
1,0
.035
2,4
.094
0,4
.016
0,7
.028
5,8 ± 0,7
.228 ± .028
E simulated
roller lever
30
1.058
US20D20E00
1,0
.035
2,2
.087
0,3
.012
0,7
.028
6,1 ± 0,7
.240 ± .028
Contact Type
Actuator
Gold, 0.1 Amp
A pin plunger
Silver, 0.5 Amp A pin plunger
OTHER TERMINATION TYPES ARE AVAILABLE
For PC right angle, change 2nd set of numbers to 50 (Example: US10D50A00)
For PC left angle, change 2nd set of numbers to 60 (Example: US10D60A00)
8
HoneywelSensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Subminiature
US Series
MOUNTING DIMENSIONS mm (for reference only)
in.
Solder Terminal Switches (with mounting holes)
Pin plunger (Type A)
Flat lever (Type C)
Simulated roller (Type E)
PC Board Terminals Switches
Pin plunger (Type A)
Right angle terminal (Type 50)
Miniature/
Subminiature
Left angle terminal (Type 60)
Flat lever (Type C)
Simulated roller (Type E)
Mounting screw size is m 1,4.
Maximum tightening torque is 1 kg-cm.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
9
Basic Switches
Subminiature
UX Series
NC
C NO
ELECTRICAL RATINGS (in amps)
FEATURES
1 Compact size – helps minimize equipment size
1 Choice of low energy or power duty electrical ratings
1 Variety of integral actuators
1 Temperature Range: –25° to +85°C (–13 to 185°F)
1 Weight: 0.5 grams (.018 oz.)
1 UL/CSA marking designations
1 Form C single-pole double-throw (SPDT) circuitry
Silver Contacts
UX40 Type
UX30 Type
Voltage
125 VAC*
30 VDC
6 VDC
12 VDC
24 VDC
3A
2A
–
–
–
Gold Contacts
UX10 Type
1A
1A
–
–
–
0.1 A
0.1 A
5 mA
2 mA
1 mA
*UL/CSA rating. UL File No. E12252. UL Standard 1054.CSA file LR23413M167
ORDER GUIDE
Terminals
Rating
Gold,
0.1 Amp 125 VAC
Solder
PC Straight
SelfSupporting
75
2.65
UX10C10A01
UX10C30A01
10
.353
0,5
.020
0,25
.010
0,12
.005
5,5 ± 0,2
.217 ± .008
150
5.3
UX10E10A01
UX10E30A01
20
.705
0,5
.020
0,25
.010
0,12
.005
5,5 ± 0,2
.217 ± .008
25
.88
UX10C10C01
UX10C30C01
2,5
.088
2,1
.083
0,55
.022
0,50
.020
6,8 ± 1,0
.268 ± .039
50
1.76
UX10E10C01
UX10E30C01
5,0
.176
2,1
.083
0,55
.022
0,50
.020
6,8 ± 1,0
.268 ± .039
27
.95
55
1.94
UX10C10E01
UX10C30E01
UX10E10E01
UX10E30E01
2,0
.071
4,0
.141
2,1
.083
2,1
.083
0,50
.020
0,50
.020
0,50
.020
0,50
.020
9,5 ± 1,0
.374 ± .039
9,5 ± 1,0
.374 ± .039
A pin plunger
75
2.65
UX30C10A01
UX30C30A01
10
.353
0,5
.020
0,25
.010
0,12
.005
5,5 ± 0,2
.217 ± .008
C flat lever
25
.88
UX30C10C01
UX30C30C01
2,5
.088
2,1
.083
0,55
.022
0,50
.020
6,8 ± 1,0
.268 ± .039
E roller lever
simulated
27
.95
UX30C10E01
UX30C30E01
2,0
.071
2,1
.083
0,50
.020
0,50
.020
9,5 ± 1,0
.374 ± .039
A pin plunger
150
5.3
UX40E10A01
UX40E30A01
20
.705
0,5
.020
0,25
.010
0,12
.005
5,5 ± 0,2
.217 ± .008
C flat lever
50
1.76
UX40E10C01
UX40E30C01
5,0
.176
2,1
.083
0,55
.022
0,50
.020
6,8 ± 1,0
.268 ± .039
E roller lever
simulated
55
1.94
UX40E10E01
UX40E30E01
4,0
.141
2,1
.083
0,50
.020
0,50
.020
9,5 ± 1,0
.374 ± .039
Actuator
A pin plunger
C flat lever
E roller lever
simulated
Silver,
1 Amp 125 VAC
Silver,
3 Amp 125 VAC
O.F. max.
grams
oz.
R.F. min. P.T. max. O.T. min. D.T. max.
g
mm
mm
mm
ounces
inches
inches
inches
OTHER TERMINATION TYPES ARE AVAILABLE
For PC right angle, change 2nd set of numbers to 50 (Example: UX10C50A01)
For PC left angle, change 2nd set of numbers to 60 (Example: UX10C60A01)
10
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
O.P
mm
inches
Basic Switches
Subminiature
UX Series
MOUNTING DIMENSIONS (for reference only) mm
in.
Pin plunger (Type A)
Solder terminals – Type 10
PC board terminals – Type 30
PC board mounting
Type 50
Type 60
Miniature/
Subminiature
LEVER ACTUATORS
UX Series switches with lever actuators can be operated by
cams or slides. They require lower operating forces than pin
plunger switches.
Flat levers are .520 in. (13,2 mm) long and simulated roller levers are .480 in. (12,2 mm) long.
Flat lever (Type C)
Simulated Roller Lever (Type E)
Mounting screw size is 2 mm.
Maximum tightening torque is 1 kg-cm.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
11
Basic Switches
Subminiature
UM Series
C
NO
NC
ELECTRICAL RATINGS (in amps)
FEATURES
1 Choice of low energy or power duty electrical
ratings
1 Variety of integral actuators
1 Temperature Range: −25° to +85°C (−13° to
185°F)
1 Weight: 2 grams (.07 oz.)
1 UL/CSA/VDE/SEMKO marking designations
1 Form C single-pole double-throw (SPDT) circuitry
Voltage
UM50E
Silver Contacts
Resistive Inductive
125 VAC
250 VAC
30 VDC
5
5
5
3
3
3*
UM40B/D
Silver Contacts
Resistive Inductive
3
3
3
2
2
2*
UM10A/B/D/E
Gold Contacts
Resistive
0.1
0.1
0.1
*Time constant for DC inductive loads: less than 7 msec.
UL File No. E12252, CSA File LR23413M167
ORDER GUIDE 0.1 AMP TYPE GOLD CONTACTS
Rating
Actuator
Length
O.F. max.
grams
oz.
A pin plunger
0.1 Amp
250 VAC
B flat lever
18mm
C flat lever
20mm
D flat lever
26mm
Honeywell Sensing and Control
Solder
.110 QC
O.P
mm
inches
25
.88
UM10A10A01 UM10A70A01
2
.071
0,6
.024
0,4
.016
0,1
.004
8,4 ± 0,3
.331 ± .012
50
1.76
UM10B10A01 UM10B70A01
7,5
.265
0,6
.024
0,4
.016
0,1
.004
8,4 ± 0,3
.331 ± .012
100
3.57
UM10D10A01 UM10D70A01
15
.529
0,6
.024
0,4
.016
0,1
.004
8,4 ± 0,3
.331 ± .012
150
5.3
UM10E10A01 UM10E70A01
20
.705
0,6
.024
0,4
.016
0,1
.004
8,4 ± 0,3
.331 ± .012
10
.35
20
.7
UM10A10B01 UM10A70B01
0,4
.014
1,7
.060
2,5
.098
2,5
.098
0,8
.031
0,8
.031
0,5
.020
0,5
.020
8,8 ± 0,8
.346 ± .031
8,8 ± 0,8
.346 ± .031
UM10B10B01 UM10B70B01
40
1.4
UM10D10B01 UM10D70B01
3,5
.123
2,5
.098
0,8
.031
0,5
.020
8,8 ± 0,8
.346 ± .031
60
2.1
UM10E10B01 UM10E70B01
4,0
.141
2,5
.098
0,8
.031
0,5
.020
8,8 ± 0,8
.346 ± .031
8
.28
16
.56
UM10A10C01 UM10A70C01
0,35
.012
1,5
.053
2,8
.110
2,8
.110
1,2
.047
1,2
.047
0,8
.031
0,8
.031
8,8 ± 0,8
.346 ± .031
8,8 ± 0,8
.346 ± .031
UM10B10C01 UM10B70C01
35
1.23
UM10D10C01 UM10D70C01
3,0
.106
2,8
.110
1,2
.047
0,8
.031
8,8 ± 0,8
.346 ± .031
55
2
UM10E10C01 UM10E70C01
3,5
.123
2,8
.110
1,2
.047
0,8
.031
8,8 ± 0,8
.346 ± .031
12
.4
25
.88
UM10B10D01 UM10B70D01
1,2
.042
2,5
.088
3,5
.138
3,5
.138
1,6
.063
1,6
.063
1,0
.039
1,0
.039
8,8 ± 1,2
.346 ± .047
8,8 ± 1,2
.346 ± .047
3,0
.106
3,5
.138
1,6
.063
1,0
.039
8,8 ± 1,2
.346 ± .047
45
1.6
12
R.F. min. P.T. max. O.T. min. D.T. max.
g
mm
mm
mm
ounces
inches
inches
inches
Terminals
UM10D10D01 UM10D70D01
UM10E10D01 UM10E70D01
For application help: call 1-800-537-6945.
Basic Switches
Subminiature
UM Series
ORDER GUIDE 0.1 AMP TYPE GOLD CONTACTS cont.
Rating
0.1 Amp
250 VAC
0.1 Amp
250 VAC
Actuator
Length
J flat lever
60mm
E simulated
roller lever, radius
2,5mm,
19mm
H simulated
roller lever, radius
1,3mm,
19mm
F roller lever
18,00mm
Terminals
R.F. min.
g
ounces
P.T. max.
mm
inches
O.T. min. D.T. max.
mm
mm
inches
inches
O.P
mm
inches
Solder
.110 QC
6
.2
UM10B10J01
UM10B70J01
0,5
.018
8,5
.335
2,2
.087
2,5
.098
8,8 ± 2,4
.346 ± .094
15
.52
UM10D10J01
UM10D70J01
1,0
.035
8,5
.335
2,2
.087
2,5
.098
8,8 ± 2,4
.346 ± .094
20
.7
UM10E10J01
UM10E70J01
1,0
.035
8,5
.335
2,2
.087
2,5
.098
8,8 ± 2,4
.346 ± .094
16
.56
UM10B10E01
UM10B70E01
1,5
.053
2,8
.110
1,2
.047
0,8
.031
11,65 ± 0,8
.459 ± .031
35
1.23
UM10D10E01
UM10D70E01
3,0
.106
2,8
.110
1,2
.047
0,8
.031
11,65 ± 0,8
.459 ± .031
55
2
UM10E10E01
UM10E70E01
3,5
.123
2,8
.110
1,2
.047
0,8
.031
11,65 ± 0,8
.459 ± .031
16
.56
UM10B10H01
UM10B70H01
1,5
.053
2,8
.110
1,2
.047
0,8
.031
10,7 ± 0,8
.421 ± .031
35
1.23
UM10D10H01
UM10D70H01
3,0
.106
2,8
.110
1,2
.047
0,8
.031
10,7 ± 0,8
.421 ± .031
55
2
UM10E10H01
UM10E70H01
3,5
.123
2,8
.110
1,2
.047
0,8
.031
10,7 ± 0,8
.421 ± .031
20
.7
UM10B10F01
UM10B70F01
1,7
.060
2,5
.098
0,8
.031
0,5
.020
14,50 ± 0,8
.571 ± .031
40
1.4
UM10D10F01
UM10D70F01
3,5
.123
2,5
.098
0,8
.031
0,5
.020
14,50 ± 0,8
.571 ± .031
60
2.1
UM10E10F01
UM10E70F01
4,0
.141
2,5
.098
0,8
.031
0,5
.020
14,50 ± 0,8
.571 ± .031
OTHER TERMINATION TYPES ARE AVAILABLE
For PC Straight cross-line, change 2nd set of numbers to 20 (Example: UM10A20A01)
For PC Straight international, change 2nd set of numbers to 40 (Example: UM10A40A01)
For PC Straight right angle, change 2nd set of numbers to 50 (Example: UM10A50A01)
For PC Straight left angle, change 2nd set of numbers to 60 (Example: UM10A60A01)
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
13
Miniature/
Subminiature
0.1 Amp
250 VAC
O.F. max.
grams
oz.
Basic Switches
Subminiature
UM Series
ORDER GUIDE 3 AND 5 AMP TYPE SILVER CONTACTS
Rating
3 Amp
250 VAC
3 Amp
250 VAC
Actuator
Length
O.F. max.
grams
oz.
P.T. max.
mm
inches
O.T. min. D.T. max.
mm
mm
inches
inches
Solder
.110 QC
UM40B70A01
7,5
.265
0,6
.024
0,4
.016
0,1
.004
8,4 ± 0,3
.331 ± .012
100
3.527
UM40D10A01
UM40D70A01
15,0
.529
0,6
.024
0,4
.016
0,1
.004
8,4 ± 0,3
.331 ± .012
20
.7
UM40B10B01
UM40B70B01
1,7
.060
2,5
.098
0,8
.031
0,5
.020
8,8 ± 0,8
.346 ± .031
40
1.4
UM40D10B01
UM40D70B01
3,5
.123
2,5
.098
0,8
.031
0,5
.020
8,8 ± 0,8
.346 ± .031
16
.56
UM40B10C01
UM40B70C01
1,5
.053
2,8
.110
1,2
.047
0,8
.031
8,8 ± 0,8
.346 ± .031
35
1.23
UM40D10C01
UM40D70C01
3,0
.106
2,8
.110
1,2
.047
0,8
.031
8,8 ± 0,8
.346 ± .031
12
.4
UM40B10D01
UM40B70D01
1,2
.042
3,5
.138
1,6
.063
1,0
.039
8,8 ± 1,2
.346 ± .047
25
.88
UM40D10D01
UM40D70D01
2,5
.088
3,5
.138
1,6
.063
1,0
.039
8,8 ± 1,2
.346 ± .047
6
.2
UM40B10J01
UM40B70J01
0,5
.018
8,5
.335
2,2
.087
2,5
.098
8,8 ± 2,4
.346 ± .094
15
.52
UM40D10J01
UM40D70J01
1,0
.035
8,5
.335
2,2
.087
2,5
.098
8,8 ± 2,4
.346 ± .094
16
.56
UM40B10E01
UM40B70E01
1,5
.053
2,8
.110
1,2
.047
0,8
.031
11,65 ± 0,8
.459 ± .031
35
1.23
UM40D10E01
UM40D70E01
3,0
.106
2,8
.110
1,2
.047
0,8
.031
11,65 ± 0,8
.459 ± .031
16
.56
UM40B10H01
UM40B70H01
1,5
.053
2,8
.110
1,2
.047
0,8
.021
10,7 ± 0,8
.421 ± .031
35
1.23
UM40D10H01
UM40D70H01
3,0
.106
2,8
.110
1,2
.047
0,8
.031
10,7 ± 0,8
.421 ± .031
20
.7
UM40B10F01
UM40B70F01
1,7
.060
2,5
.098
0,8
.031
0,5
.020
14,50 ± 0,8
.571 ± .031
40
1.4
UM40D10F01
UM40D70F01
3,5
.123
2,5
.098
0,8
.031
0,5
.020
14,50 ± 0,8
.571 ± .031
A pin plunger
150
5.3
UM50E10A01
UM50E70A01
20
.705
0,6
.024
0,4
.016
0,1
.004
8,4 ± 0,3
.331 ± .012
B flat lever
18mm
60
2.1
UM50E10B01
UM50E70B01
4,0
.141
2,5
.098
0,8
.031
0,5
.020
8,8 ± 0,8
.346 ± .031
C flat lever
20mm
55
2
UM50E10C01
UM50E70C01
3,5
.123
2,8
.110
1,2
.047
0,8
.031
8,8 ± 0,8
.346 ± .031
D flat lever
26mm
45
1.6
UM50E10D01
UM50E70D01
3,0
.106
3,5
.138
1,6
.063
1,0
.039
8,8 ± 1,2
.346 ± .047
UM50E10J01
UM50E70J01
1,0
.035
8,5
.335
2,2
.087
2,5
.098
8,8 ± 2,4
.346 ± .094
B flat lever
18mm
J flat lever
60mm
E simulated
roller lever, radius
2,5mm
19mm
H simulated
roller lever, radius
1,3mm
19,15mm
F roller lever
18mm
J flat lever
60mm
E simulated
roller lever, radius
2,5mm
19mm
55
2
UM50E10E01
UM50E70E01
3,5
.123
2,8
.110
1,2
.047
0,8
.031
11,65 ± 0,8
.459 ± .031
H simulated
roller lever, radius
1,3mm
19mm
55
2
UM50E10H01
UM50E70H01
3,5
.123
2,8
.110
1,2
.047
0,8
.031
10,7 ± 0,8
.421 ± .031
F roller lever
18mm
60
2.1
UM50E10F01
UM50E70F01
4,0
.141
2,5
.098
0,8
.031
0,5
.020
14,50 ± 0,8
.571 ± .031
OTHER TERMINATION TYPES ARE AVAILABLE
For PC Straight cross-line, change 2nd set of numbers to 20 (Example: UM40B20A01)
For PC Straight international, change 2nd set of numbers to 40 (Example: UM40B40A01)
For PC Straight right angle, change 2nd set of numbers to 50 (Example: UM40B50A01)
For PC Straight left angle, change 2nd set of numbers to 60 (Example: UM40B60A01)
14
O.P
mm
inches
UM40B10A01
D flat lever
26mm
5 Amp
250 VAC
R.F. min.
g
ounces
50
1.76
A pin plunger
C flat lever
20mm
3 Amp
250 VAC
Terminals
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Subminiature
UM Series
MOUNTING DIMENSIONS (for reference only) mm
in.
Pin Plunger Type A
PC Straight Cross-Line – Type 20
PC Straight In-line – Type 40
PC Right Angle In-line – Type 50
PC Left Angle In-line – Type 60
QC Quick Connect – Type 70
18mm Flat Lever Type B
20mm Flat Lever Type C
26mm Flat Lever Type D
60mm Type J
19mm Simulated Roller Type E/H
Type H has 1,3mm radius
Type E has 2,5mm radius
18mm Roller Lever Type F
5mm (.197 in.) dia. x 3,2mm (.126 in.)
thick roller
Miniature/
Subminiature
Solder Cross-line Terminals – Type 10
Lever Actuators 4mm (.158) wide
Mounting screw size is m 2,3.
Maximum tightening torque is 3 kg-cm.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
15
Basic Switches
Sealed Subminiature
IP50-SEALED
FEATURES
1 Silver or gold contacts
1 Variety of integral actuator styles including pin
plunger, flat lever, roller lever, and simulated
roller lever
1 IP50 or IP67 type sealing
1 Choice of quick-connect, printed circuit board,
solder or leadwire termination
1 Form C single-pole double-throw
1 Temperature range: −40° to 85°C (−40° to
185°F)
1 Weight, approx.: .07 oz. (2g.) for IP50-sealed
switches; and .14 oz. (4g.) for IP67-sealed
switches, not including leadwires
1 UL, CSA, VDE, and SEMKO marking
designations
UM Series
IP67-SEALED
ELECTRICAL RATINGS (in amps)
Voltage
125 VAC
250 VAC
30 VDC
125 VDC
Silver Contacts
Resistive
Inductive
2.0
2.0
2.0
0.4
2.0
2.0
2.0
0.05
Gold Contacts
Resistive
0.1A
0.1A
0.1A
—
UL File No. E12252, CSA File LR23413M167
IP50-sealed UM switches are the same size as non-sealed UM switches on
pages 12-15. There is an elastomer seal on the switch plunger and a cover-tocase seal. They provide a degree of protection against the entry of dust.
IP67-sealed UM switches have the plunger seal and cover-to-case seal. In
addition, their AWG #20 leadwires are molded in epoxy resin. They provide a
degree of protection against water entry during temporary immersion.
16
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
IP50-Sealed Subminiature
C
NO
UM Series
NC
ORDER GUIDE IP50 SEALED 0.1-AMP GOLD CONTACTS
Actuators
O.F. max.
grams
oz.
Termination
Solder
.110 QC
R.F. min.
grams
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T. max.
mm
inches
O.P
mm
inches
pin plunger
150
5.3
UM10E11AS1
UM10E71AS1
20
.705
0,6
.024
0,4
.016
0,1
.004
8,4 ± 0,3
.331 ± .012
B
flat lever
60
2.1
UM10E11BS1
UM10E71BS1
4,0
.141
2,5
.098
0,8
.031
0,5
.020
8,8 ± 0,8
.346 ± .031
C
flat lever
55
1.9
UM10E11CS1
UM10E71CS1
3,5
.123
2,8
.110
1,2
.047
0,8
.031
8,8 ± 0,8
.346 ± .031
D
flat lever
45
1.6
UM10E11DS1
UM10E71DS1
3,0
.106
3,5
.138
1,6
.063
1,0
.039
8,8 ± 1,2
.346 ± .047
E
simulated
roller lever
55
1.9
UM10E11ES1
UM10E71ES1
3,5
.123
2,8
.110
1,2
.047
0,8
.031
11,65 ± 0,8
.459 ± .031
F
roller
lever
60
2.1
UM10E11FS1
UM10E71FS1
4,0
.141
2,5
.098
0,8
.031
0,5
.020
14,5 ± 0,8
.571 ± .031
R.F. min.
grams
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T. max.
mm
inches
O.P
mm
inches
ORDER GUIDE IP50 SEALED 2.0-AMP SILVER CONTACTS
Actuators
O.F. max.
grams
oz.
Termination
Solder
.110 QC
A
pin plunger
150
5.3
UM35E11AS1
UM35E71AS1
20
.705
0,6
.024
0,4
.016
0,1
.004
8,4 ± 0,3
.331 ± .012
B
flat lever
60
2.1
UM35E11BS1
UM35E71BS1
4,0
.141
2,5
.098
0,8
.031
0,5
.020
8,8 ± 0,8
.346 ± .031
C
flat lever
55
1.9
UM35E11CS1
UM35E71CS1
3,5
.123
2,8
.110
1,2
.047
0,8
.031
8,8 ± 0,8
.346 ± .031
D
flat lever
45
1.6
UM35E11DS1
UM35E71DS1
3,0
.106
3,5
.138
1,6
.063
1,0
.039
8,8 ± 1,2
.346 ± .047
E
simulated
roller lever
55
1.9
UM35E11ES1
UM35E71ES1
3,5
.123
2,8
.110
1,2
.047
0,8
.031
11,65 ± 0,8
.459 ± .031
F
roller
lever
60
2.1
UM35E11FS1
UM35E71FS1
4,0
.141
2,5
.098
0,8
.031
0,5
.020
14,5 ± 0,8
.571 ± .031
TO SPECIFY PC TERMINALS:
In the order guides above, change the 2nd set of numbers to 21. Example: UM10E11AS1 converts to UM10E21AS1 with PC terminals
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
17
Miniature/
Subminiature
A
Basic Switches
IP67-Sealed Subminiature
C
NO
UM Series
NC
ORDER GUIDE IP67 SEALED 0.1-AMP GOLD AND 2.0-AMP SILVER CONTACTS
Actuators
O.F. max.
grams
oz.
Leadwire Termination
R.F. min.
grams
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T. max.
mm
inches
O.P
mm
inches
Gold Contacts
Silver Contacts
A
pin plunger
150
5.3
UM10E90AS1
UM35E90AS1
20
.705
0,6
.024
0,4
.016
0,1
.004
8,4 ± 0,3
.331 ± .012
B
flat lever
60
2.1
UM10E90BS1
UM35E90BS1
4,0
.141
2,5
.098
0,8
.031
0,5
.020
8,8 ± 0,8
.346 ± .031
C
flat lever
55
1.9
UM10E90CS1
UM35E90CS1
3,5
.123
2,8
.110
1,2
.047
0,8
.031
8,8 ± 0,8
.346 ± .031
D
flat lever
45
1.6
UM10E90DS1
UM35E90DS1
3,0
.106
3,5
.138
1,6
.063
1,0
.039
8,8 ± 1,2
.346 ± .047
E
simulated
roller lever
55
1.9
UM10E90ES1
UM35E90ES1
3,5
.123
2,8
.110
1,2
.047
0,8
.031
11,65 ± 0,8
.459 ± .031
F
roller
lever
60
2.1
UM10E90FS1
UM35E90FS1
4,0
.141
2,5
.098
0,8
.031
0,5
.020
14,5 ± 0,8
.571 ± .031
MOUNTING DIMENSIONS
(For reference only)
mm
in.
Mounting screw size is m 2,3
Maximum torque is 3 kg/cm.
Pin Plunger Type A
PC Terminals
18
Honeywell Sensing and Control
Solder In-line Terminals
For application help: call 1-800-537-6945.
Basic Switches
IP50-Sealed Subminiature
MOUNTING DIMENSIONS
(For reference only)
mm
in.
UM Series
Mounting screw size is m 2,3
Maximum torque is 3 kg/cm.
Pin Plunger Type A
QC In-line Terminals
Leadwires
Miniature/
Subminiature
Lever Actuators 4 mm/.158 in. wide
18 mm Flat Lever Type B
19 mm Simulated Roller Lever Type E
2,5 mm radius
20 mm Flat Lever Type C
18 mm Roller Lever Type F
5 mm/.197 in. dia. x 3,2 mm/.126 in.
Thick Roller
26 mm Flat Lever Type D
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
19
Basic Switches
Subminiature
SX Series
CUT-A-WAY 1SX SUBMINIATURE BASIC SWITCH
T
GENERAL INFORMATION
SX subminiature basic switches are small
size precision snap-action switches from
MICRO SWITCH. These switches are ideal where savings in space and weight are
important. Unless otherwise noted, all
listings have silver contacts.
T2
Mounting torque Round
head 2-56 UNC 438
screws—
2 inch pounds max.
H58
STRAIGHT PIN
H391, H392
90° FORMED PIN
Mate with Amp Inc. Part No.
640024-1 Std.
Dimensions shown are for reference only
This section covers only 40 of our most popular SX Series catalog listings. If you don’t find what you’re looking for, it’s
likely one of the approximately 200 other active SX listings will meet your needs. Contact the 800 number.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
21
Miniature/
Subminiature
AVAILABLE TERMINALS
SX switches are available with several
types of terminations. The T and T2 terminals provide easy solder lead wire attachment. The H58 terminal offers the simplicity of quick-connect and mate with AMP
.058-inch receptacles. Pin terminals allow
easy attachment to printed circuit boards.
FEATURES
1 Low operating force to 3 oz. (85 grams)
maximum
1 Sensitive differential travel as low as
.001 inch maximum
1 Power load switching capability up to 7
amperes—silver contacts
1 Optional gold contacts for low energy
applications
1 Optional bifurcated gold contacts for
maximum reliability
1 Long mechanical life up to 10,000,000
cycles—95% survival for 11SX series
1,000,000 cycles—95% survival for 1SX
series
1 Temperature tolerance −65° to
+250°F (−54 to 121°C) on standard
construction
1 High temperature designs for up to
+400°F (204°C) for 100 hours
1 Variety of integral and auxiliary
actuators
1 Choice of several terminal styles
1 MIL-S-8805
qualified
products
available
1 UL recognized File #E12252, CSA certified file # LR41372
Basic Switches
Subminiature
SX Series
ORDER GUIDE by ascending electrical capability
PIN PLUNGER
Catalog
Listing
Dim. Dwg. Fig. 1
(Except Fig. 2
for 91SX39-T
and 93SX34-T)
Recommended for
Electrical
Data and O.F. max. R.F. min.
UL Code newtons newtons
Page 20
ounces
ounces
11SX91-T
Logic level loads
5VDC, 2mA; SPNO
At
Left
12SX2-T
Best reliability
(Bifurcated gold contacts)
3SX1-T
Applications requiring gold
contacts (1SX type)
1 Amp
D
12SX1-T
Best reliability with
higher current rating
(Bifurcated gold contacts)
12SX3-T
1,39
5
P.T. max. O.T. min. D.T. max. O.P.*
mm
mm
mm
mm
inches
inches
inches inches
0,28
1
0,51
.020
0,1
.004
0,1
.004
8,13
.320
0,28
1
0,51
.020
0,1
.004
0,051
.002
8,13
.320
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
1 Amp
D
1,39
5
0,28
1
0,51
.020
0,1
.004
0,076
.003
8,13
.320
Lowest differential travel
with bifurcated gold contacts
1 Amp
H
1,39
5
0,28
1
0,51
.020
0,1
.004
0,025
.001
8,13
.320
13SX21-T
Applications requiring gold
contacts. 11SX type.
1 Amp
D
1,39
5
0,28
1
0,51
.020
0,1
.004
0,051
.002
8,13
.320
23SX39-T
(MS24547-2)
MIL-S-8805 applications
requiring gold contacts
+180°F (82°C) max. use
1 Amp
D
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
23SX39-T2
(MS24547-5)
As above, with
T2 terminals
1 Amp
D
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
93SX39-T
M8805/109-03
.156N wide, with gold
contacts +180°F (82°C)
1 Amp
D
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
411SX21-T
M8805/106-01
+400°F (204°C)
for 100 hours
G
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.220
413SX21-T
M8805/106-02
+400°F (204°C)
for 100 hours
L
1,39
5
0,28
1
0,51
.020
0,1
.004
0,051
.002
8,13
.220
11SX1-T
Lowest differential travel
3 Amps
E
0,97
3.5
0,21
0.75
0,51
.020
0,1
.004
0,025
.001
8,13
.320
11SX21-T
Most applications
5 Amps
A
0,7 to 1,39
2.5 to 5
0,28
1
0,51
.020
0,1
.004
0,051
.002
8,13
.320
11SX22-T
For use in sealed
enclosures.
5 Amps
A
1,39
5
0,28
1
0,51
.020
0,1
.004
0,076
.003
8,13
.320
17SX21-T
Best stability under varying
humidity. 11SX type.
5 Amps
A
1,39
5
0,28
1
0,51
.020
0,1
.004
0,051
.002
8,13
.320
1SX1-T
Up to 7 amps load handling
7 Amps
B
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
1SX12-T
Low differential travel
7 Amps
C
1,39
5
0,28
1
0,51
.020
0,1
.004
0,051
.002
8,13
.320
1SX48-T
Added overtravel
7 Amps
B
1,39
5
0,28
1
0,51
.020
0,25
.010
0,13
.005
8,13
.320
2SX1-T
Lower force
7 Amps
B
0,83
3
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
4SX1-T
Operating in temperature
to +400°F (204°C)
for 100 hours
7 Amps
I
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
21SX1-T
Best stability under varying
humidity (1SX type)
7 Amps
B
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
21SX39-T
(MS24547-1)
MIL-S-8805 application
requirements +180°F (82°C)
7 Amps
F
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
21SX39-T2
(MS24547-4)
MIL-S-8805 application
requirements +180°F (82°C)
7 Amps
F
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
91SX39-T
M8805/109-01
.156N wide version
of standard SX +180°F
(82°C)
7 Amps
F
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
.010 Amp 0,7 to 1.39
H
2.5 to 5
*±0,38 mm
±.015 in.
22
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Subminiature
SX Series
Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. –
Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating
Position
ORDER GUIDE
INTEGRAL LEVERS
Catalog
Listing
O.P.
mm
inches
.135 inch (3,43 mm)
straight lever
5 Amps
A
0,49
1.76
0,09
.32
1,65
.065
0,36
.014
0,51
.020
8,43±1,14
.332±.045
313SX1-T
As above with gold
contacts
1 Amp
D
0,49
1.76
0,09
.32
1,65
.065
0,36
.014
0,51
.020
8,43±1,14
.332±.045
311SX2-T
.505 inch (12,8 mm)
straight lever
5 Amps
A
0,31
1.1
0,05
.18
2,92
.115
0,64
.025
0,89
.035
8,26±1,91
.325±.075
313SX2-T
As above with gold
contacts
1 Amp
D
0,31
1.1
0,05
.18
2,92
.115
0,64
.025
0,89
.035
8,26±1,91
.325±.075
311SX3-T
.965 inch (24,5 mm)
straight lever
5 Amps
A
0,20
.71
0,03
.11
4,70
.185
0,61
.024
1,52
.060
7,75±2,92
.305±.115
313SX3-T
As above with gold
contacts
1 Amp
D
0,20
.71
0,03
.11
4,70
.185
0,61
.024
1,52
.060
7,75±2,92
.305±.115
311SX4-T
.042 inch (1,1 mm)
simulated roller lever
5 Amps
A
0,58
2.1
0,11
.39
1,27
.050
0,25
.010
0,38
.015
14,15±0,91
.557±.036
313SX4-T
As above with gold
contacts
1 Amp
D
0,58
2.1
0,11
.39
1,27
.050
0,25
.010
0,38
.015
14,15±0,91
.557±.036
311SX5-T
.459 inch (11,7 mm)
simulated roller lever
5 Amps
A
0,31
1.1
0,05
.18
2,67
.105
0,56
.022
0,89
.035
14,86±1,65
.585±.065
313SX5-T
As above, with gold
contacts
1 Amp
D
0,31
1.1
0,05
.18
2,67
.105
0,56
.022
0,89
.035
14,86±1,65
.585±.065
Dim. Dwg. Fig. 3
Dim. Dwg. Fig. 4
Dim. Dwg. Fig. 5
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
23
Miniature/
Subminiature
311SX1-T
Dim. Dwg. Fig. 3
Dim. Dwg. Fig. 6
Description
Electrical
Data And O.F. max. R.F. min. P.T. max. O.T. min. D.T. max.
UL Code newtons newtons
mm
mm
mm
Page 20 ounces ounces inches
inches
inches
Basic Switches
Subminiature
SX
Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. –
Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating
Position; F.P. – Free Position.
*All characteristics are taken with actuator assembled on Catalog Listing 1SX1-T as shown.
ORDER GUIDE
AUXILIARY
ACTUATORS
Switches are not
included with
actuators.
Catalog
Listing
Description
Actuator
Length
‘‘A’’
O.F. max. R.F. min.
mm
newtons newtons
inches ounces ounces
P.T.
mm
inches
O.T.
mm
inches
D.T. max.
mm
inches
O.P.††
mm
inches
F.P.
mm
inches
JX-20
Straight lever
18.3
.72
0,28
1
approx.
0,04
.14
—
0,76
.030
approx.
0,76
.030
approx.
10,8
.425
approx.
12,3
.485
approx.
JX-219
Straight lever
(For higher temp.)
18,3
.72
0,28
1
0,04
.14
—
0,76
.030
approx.
0,76
.030
approx.
10,8
.425
approx.
12,3
.485
approx.
JX-25
Roller lever
16,5
.65
0,42
1.5
0,04
1.4
—
0,51
.020
0,76
.030
14,9J1,14
.585J.045
168
.660
max.
JX-220
Roller lever
(For higher temp.)
16,5
.65
0,42
1.5
0,04
.14
—
0,51
.020
0,76
.030
14,9J1,14
.585J.045
16,8
.660
max.
JX-40
Straight leaf
9,4
.37†
1,95
7
0,56
2
.225
approx.
0,38
.015
0,64
.025
7,5
.295
12,3
.485
ref.
JX-95
Straight leaf
(For higher temp.)
9,4
.37†
1,95
7
0,56
2
.225
approx.
0,38
.015
0,64
.025
7,5
.295
12,3
.485
ref.
JX-41**
Reverse leaf
9,4
.37†
1,67
6
0,28
1
.110
approx.
0,38
.015
0,64
.025
7,5
.295
9,4
.370
ref.
JX-45
Roller leaf
6,1
.24†
1,95
7
0,28
1
.225
approx.
0,38
.015
0,64
.025
12,2
.480
16,5
.650
ref.
JX-96
Roller leaf
(For higher temp.)
6,1
.24†
1,95
7
0,28
1
.225
approx.
0,38
.015
0,64
.025
12,2
.480
16,5
.650
ref.
JX-51**
Reverse roller leaf
7,6
.30†
1,67
6
0,56
2
.110
approx.
0,38
.015
0,64
.025
12,8
.505
14,7
.580
ref.
JX-4
Tandem leaf
7,9
.31
4,17
15
0,83
3
.065
approx.
0,20
.008
0,76
.030
7,6
.300
9,40
.370
ref.
Dim. Dwg. Fig. 7
Dim. Dwg. Fig. 8
Dim. Dwg. Fig. 9
Dim. Dwg. Fig. 9
Dim. Dwg. Fig. 10
24
**Switch is mounted with plunger end reversed
from JX-40.
†‘‘A’’ measurement is from center of mounting
hole nearest tip of lever to the point indicated on
drawing.
Honeywell Sensing and Control
NOTE: Above actuators should be used at temperatures below +300°F (149°C); except listings
JX-95, JX-96, JX-219 and JX-220 are for use with
the 4SX1-T to 400°F. (204°C).
Except where stated †† ±0,76 mm
±.030 in.
For application help: call 1-800-537-6945.
Basic Switches
Subminiature
SX Series
MOUNTING DIMENSIONS (for reference only)
PIN PLUNGER
INTEGRAL LEVERS
Dim. ‘‘A’’
Fig. 1
Fig. 2
311SX1-T
3,6/.14
311SX2-T
13,0/.51
Fig. 3
INTEGRAL LEVERS
Miniature/
Subminiature
Interchangeable with 1SX-1T switch with
JX-25 actuator.
Fig. 4
Fig. 5
Fig. 6
AUXILIARY ACTUATORS
Fig. 7
Switches are not included with actuator.
For application help: call 1-800-537-6945.
Fig. 8
Fig. 9
Fig. 10
Mounting holes accept pins or screws of
.087 diameter (2,21 mm).
Honeywell Sensing and Control
25
Basic Switches
Subminiature
SM Series
CUT-A-WAY SM SUBMINIATURE BASIC SWITCH
AVAILABLE TERMINALS
Various terminals are available for most
listings. These include: the T and T2 for
wrap-around soldering of leadwires; solder terminals for solder connections; H58
terminals and H4 series terminals provide
easy quick-connect installation; H2 type,
round wire wrap or PC terminals; H6 rectangular wire wrap terminals are also available. Other quick-connect terminals of
the Series H types are available. Contact
the 800 number for ordering information.
T
GENERAL INFORMATION
SM subminiature switches are slightly
larger than the SX switches. These
switches combine small size and light
weight with ample electrical capacity, precision operation and long life. Unless otherwise noted, all listings have silver contacts.
SOLDER
T2
FEATURES
1 Low operating force to 2 ounces
maximum
1 Sensitive differential travel as low as
.001 inch (0,025 mm) maximum
1 Power load switching capability
available to 11 amps (VAC) – silver
contacts
1 Motor load handling capacity to 1/4
hp (VAC)
1 Optional gold contacts for low energy
applications
1 Optional bifurcated gold contacts for
maximum reliability
1 Long mechanical life
– 11SM Series 10,000,000
operations
– 1SM/41SM Series 80,000
operations
– Bifurcated contacts 1,000,000
operations
All at 95% survival
1 Standard temperature range −65° to
+185°F (−54 to 85°C)
1 High temperature construction
available for use to +400°F (204°C)
for 100 hours
1 Variety of integral and auxiliary
actuators
1 Choice of several terminal styles
1 Military Standard construction
available with three listings on the
MIL-S-8805 qualified products list
1 UL recognized File #E12252, CSA
certified File #LR41372
Mounting Torque:
2.3 inch pounds max.
H4
H58
H2
Mates with Amp Inc. Part
No. 640024-1 Std.
Dimensions shown are for reference only
This section covers only 38 of our most popular SM Series catalog listings. If you don’t find what you’re looking for, it’s
likely one of the approximately 500 other active SM listings will meet your needs. Contact the 800 number.
26
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Subminiature
SM Series
Characteristics: O.F. — Operating Force; R.F. — Release
Force; P.T. — Pretravel; O.T. — Overtravel; D.T. —
Differential Travel; O.P. — Operating Position.
ORDER GUIDE by ascending electrical capability
PIN PLUNGERS
Catalog
Listing
O.P.*
mm
inches
11SM1077-T
Gold alloy contacts
.1 Amp
P
0,83-1,39
3-5
0,28
1
0,51
.020
0,13
.005
0,1
.004
8,38
.330
12SM604-T
Bifurcated gold contacts,
reduced rating
.1 Amp
P
0,83-1,39
3-5
0,28
1
0,51
.020
0,076
.003
0,1
.004
8,38
.330
11SM23-T
Application requiring gold
contacts
1 Amp
N
0,83-1,39
3-5
0,28
1
0,51
.020
0,13
.005
0,1
.004
8,38
.330
12SM4-T
Best reliability
(Bifurcated gold contacts)
1 Amp
N
0,83-1,39
3-5
0,28
1
0,51
.020
0,076
.003
0,1
.004
8,38
.330
11SM701-T
Lower force
4 Amps
S
0,56
2
0,14
.5
0,51
.020
0,13
.005
0,051
.002
8,38
.330
11SM1-T
Most applications
5 Amps 0,83-1,39
J
3-5
0,28
1
0,51
.020
0,13
.005
0,1
.004
8,38
.330
11SM3-T
Operating in temperatures
to +250°F (121°C)
5 Amps 0,83-1,39
J
3-5
0,28
1
0,51
.020
0,13
.005
0,1
.004
8,38
.330
11SM244-T
Operating in temperatures 5 Amps 0,83-1,39
to +400°F (204°C) 100 hrs.
*
3-5
0,28
1
0,51
.020
0,13
.005
0,1
.004
8,38
.330
11SM401-T
Less differential travel
5 Amps
K
0,28
1
0,51
.020
0,13
.005
0,025
.001
8,38
.330
21SM284-T2
(MS25085-2)
MIL-S-8805 application
requirements
5 Amps 0,83-1,39
R
3-5
0,28
1
0,76
.030
0,13
.005
0,1
.004
8,38
.330
21SM284
(MS25085-1)
MIL-S-8805 application
requirements,
solder terminals
5 Amps 0,83-1,39
R
3-5
0,28
1
0,76
.030
0,13
.005
0,1
.004
8,38
.330
22SM1-T
Best stability under
varying humidity
5 Amps 0,83-1,39
J
3-5
0,28
1
0,51
.020
0,13
.005
0,1
.004
8,38
.330
41SM1-T
Up to 11 ampere 1/4 hp
(AC) load handling
11 Amps 0,83-1,39
M
3-5
0,28
1
0,76
.030
0,13
.005
0,1
.004
8,38
.330
0,97
3.5
max.
*For electrical data call 1-800-537-6945
411SM1
Sealed plunger
construction
5 Amps 0,83-2,09
K
3-7.5
0,28
1
0,51
.020
0,13
.005
0,1
.004
8,38
.330
411SM23
As above with gold
contacts
1 Amp
N
0,28
1
0,51
.020
0,13
.005
0,1
.004
8,38
.330
0,83-2,09
3-7.5
Except where stated * ±0,38mm
±.015 in.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
27
Miniature/
Subminiature
Dim. Dwg. Fig. 1
Recommended For
Electrical
Data And
O.F.
R.F. min. P.T. max. O.T. min. D.T. max.
UL Code newtons newtons
mm
mm
mm
Page 20 ounces ounces inches
inches
inches
Basic Switches
Subminiature
SM Series
Characteristics: O.F. — Operating Force; R.F. — Release
Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential
Travel; O.P. — Operating Position.
ORDER GUIDE
INTEGRAL LEVERS
Catalog
Listing
.285 inch (7,24mm)
straight lever
5 Amps
J
0,39
1.4
0,07
.25
2,16
.085
0,51
.020
0,48
.019
8,64±1,5
.340±.060
311SM23-T
As above with gold
contacts
1 Amp
N
0,39
1.4
0,07
.25
2,16
.085
0,51
.020
0,48
.019
8,64±1,5
.340±.060
311SM701-T
.285 inch (7,24mm)
straight lever.
Lower force
4 Amps
S
0,16
.57
0,03
.11
2,16
.085
0,51
.020
0,36
.014
8,64±1,5
.340±.060
311SM2-T
.565 inch (14,35mm)
straight lever
5 Amps
J
0,31
1.1
0,05
.18
3,05
.120
0,66
.026
0,69
.027
8,51±2
.335±.080
311SM43-T
As above with gold
contacts
1 Amp
N
0,31
1.1
0,05
.18
3,05
.120
0,66
.026
0,69
.027
8,51±2
.335±.080
311SM702-T
.565 inch (14,35mm)
straight lever.
Lower force
4 Amps
S
0,11
.4
0,02
.07
3,05
.120
0,66
.026
0,38
.015
8,51±2
.335±.080
311SM3-T
1.765 inch (44,8mm)
straight lever
5 Amps
J
0,15
.53
0,02
.07
7,87
.310
1,45
.057
2,8
.110
7,11±4,3
.280±.170
311SM17-H58 As above with gold
contacts
1 Amp
N
0,15
.53
0,02
.07
7,87
.310
1,45
.057
2,8
.110
7,11±4,3
.280±.170
311SM703-T
1.765 inch (44,8mm)
straight lever.
Lower force
4 Amps
S
0,06
.2
0,01
.04
7,87
.310
1,45
.057
1,78
.070
7,11±4,3
.280±170
311SM4-T
.251 inch (6,38mm)
simulated roller lever
5 Amps
J
0,39
1.4
0,07
.25
2,16
.085
0,46
.018
0,48
.019
11,7±1,5
.460±.060
311SM25-T
As above with gold
contacts
1 Amp
N
0,39
1.4
0,07
.25
2,16
.085
0,46
.018
0,48
.019
11,7±1,5
.460±.060
311SM704-T
.251 inch (6,38mm)
simulated roller lever.
Lower force
4 Amps
S
0,16
.57
0,03
.11
2,16
.085
0,46
.018
0,33
.013
11,7±1,5
.460±.060
311SM5-T
.535 inch (13,6mm)
simulated roller lever
5 Amps
J
0,31
1.1
0,05
.18
3,05
.120
0,66
.026
0,69
.027
11,56±2
.455±.080
311SM705-T
.535 inch (13,6mm)
simulated roller lever.
Lower force
4 Amps
S
0,11
.4
0,02
.07
3,05
.120
0,66
.026
0,38
.015
11,56±2
.455±.080
311SM6-T
.251 inch (6,38mm)
roller lever
5 Amps
J
0,39
1.4
0,07
.25
2,16
.085
0,46
.018
0,48
.019
14,2±1,5
.560±.060
311SM68-T
As above with gold
contacts
1 Amp
N
0,39
1.4
0,07
.25
2,16
.085
0,46
.018
0,48
.019
14,2±1,5
.560±.060
311SM706-T
.251 inch (6,38mm)
roller lever.
Lower force
4 Amps
S
0,16
.57
0,03
.11
2,16
.085
0,46
.018
0,33
.013
14,2±1,5
.560±.060
311SM7-T
.535 inch (13,6mm)
roller lever
5 Amps
J
0,31
1.1
0,05
.18
3,05
.120
0,66
.026
0,69
.027
14,1±2
.555±.080
Dim. Dwg. Fig. 6
Dim. Dwg. Fig. 7
Dim. Dwg. Fig. 8
Dim. Dwg. Fig. 9
Dim. Dwg. Fig. 10
28
O.P.
mm
inches
311SM1-T
Dim. Dwg. Fig. 4
Dim. Dwg. Fig. 5
Description
Electrical
Data And O.F. max. R.F. max. P.T. max. O.T. min. D.T. max.
UL Code newtons newtons
mm
mm
mm
Page 20 ounces ounces
inches
inches
inches
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Subminiature
SM Series
ORDER GUIDE
INTEGRAL LEAF
Catalog
Listing
Dim. Dwg. Fig. 11
Recommended For
Electrical
Data And O.F. max. R.F. min. P.T. max. O.T. min. D.T. max.
UL Code newtons newtons
mm
mm
mm
Page 20 ounces ounces
inches
inches
inches
O.P.
mm
inches
111SM1-T
Force and stability of
flexible leaf actuator
5 Amps
J
1,95
7
0,56
2
5,54
.218
0,76
.030
0,76
.030
8,89±0,76
.350±.030
111SM17-T
As above with gold
contacts
1 Amp
N
1,95
7
0,56
2
5,54
.218
0,76
.030
0,76
.030
8,89±0,76
.350±.030
111SM2-T
Flexible leaf with roller
5 Amps
J
1,95
7
0,56
2
5,56
.219
0,76
.030
0,64
.025
14,3±0,76
.562±.030
111SM23-T
As above with gold
contacts
1 Amp
N
1,95
7
0,56
2
5,56
.219
0,76
.030
0,64
.025
14,3±0,76
.562±.030
Dim. Dwg. Fig. 12
Miniature/
Subminiature
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
29
Basic Switches
Subminiature
SM Series
Characteristics: O.F. — Operating Force; R.F. — Release Force;
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P.
— Operating Position; F.P. — Free Position
AUXILIARY
ACTUATORS
* All characteristics are taken with actuator assembled to Catalog Listing 11SM3-T as
shown.
ORDER GUIDE
Switches are not
included with the
actuators.
Catalog
Listing
Description
Actuator
Length
‘‘A’’
O.F. max. R.F. min.
mm
newtons newtons
inches ounces ounces
P.T. max.
mm
inches
O.T. min. D.T. max.
mm
mm
inches
inches
O.P.
mm
inches
F.P. max.
mm
inches
JS-2
Straight leaf
16,8
.66
2,78
10
0,56
2
1,98
.078
0,38
.015
0,38
.015
8,89±0,38
.350±.015
11,3
.445
JS-5
Roller leaf
(Bronze roller)
15
.59
2,78
10
0,83
3
1,98
.078
0,38
.015
0,38
.015
14,2±0,38
.580±.015
16,9
.665
JS-7
Formed leaf
(Simulated
roller)
14,7
.58
2,78
10
0,56
2
2,39
.094
0,79
.031
0,38
.015
9,65±0,38
.380±.015
12,1
.475
JS-220
Straight lever
26,2†
1.03
0,28
1
0,04
.14
3,18
.125 approx.
0,76
.030
0,76
.030
10,3
.406 approx.
—
JS-246
Roller lever
(Steel roller)
25,4†
1.00
0,28
1
0,04
.14
3,18
.125 approx.
0,76
.030
0,76
.030
14,3
.562 approx.
—
JS-221
Formed lever
(Simulated
roller)
25,4†
1.00
0,28
1
0,04
.14
3,18
.125 approx.
0,76
.030
0,76
.030
11,6
.455 approx.
—
JS-33**
Tandem leaf
5,3
.21
5,00
18
2,78
10
2,36
.093
0,15
.006
0,38
.015
8,89±0,38
.350±.015
10,5
.415
JS-31**
Tandem
roller leaf
(Bronze roller)
4,3
.17
11,1
40
4,45
16
2,36
.093
0,13
.005
0,38
.015
14,5±0,38
.570±.015
16,1
.635
Dim. Dwg. Fig. 14
Dim. Dwg. Fig. 14
Dim. Dwg. Fig. 14
Dim. Dwg. Fig. 16
Dim. Dwg. Fig. 16
Dim. Dwg. Fig. 16
**Travel characteristics on tandem actuators vary with actual basic switch characteristics.
NOTE: Above actuators should be used below +300°F.
See page 79 for other actuators that may be used with SM Switches at higher temperatures.
†‘‘A’’ measurement is from the pivot point of lever to the point indicated on drawing.
30
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Subminiature
SM Series
MOUNTING DIMENSIONS (for reference only)
PIN PLUNGER
Fig. 1
Fig. 2
INTEGRAL LEVERS
Fig. 8
Fig. 5
Fig. 9
Fig. 6
Fig. 7
Fig. 10
INTEGRAL LEAFS
Mounting holes accept pins or screws of
.087 inch (2,21 mm) max. diameter
Fig. 11
Fig. 12
AUXILIARY ACTUATORS
Fig. 14
Fig. 16
Switches are not included with the actuators.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
31
Miniature/
Subminiature
Fig. 4
Position Sensors
Environment-Sealed Basic Switches
SE and XE Series
GENERAL INFORMATION
SE and XE switches are the smallest environment-sealed switches offered by
MICRO SWITCH. Both types enclose basic switches within a corrosion resistant
aluminum housing to seal precision
switch contacts from contamination. SE
switches include a SM basic switch, and
XE switches include the smaller SX basic
switch.
Switches held depressed for extended
periods of time at temperature extremes
may experience retarded plunger return
upon deactuation. Where such a condition exists in the application, contact the
800 number for special designs that are
available.
FEATURES
1 Watertight seal per enclosure design
symbol 3, MIL-S-8805
1 Power load switching capability up to 7
amps
1 Temperature tolerance up to +221°F
(105°C)
1 High temperature construction for use
to +300°F (149°C)
1 Several auxiliary actuators
1 Choice of termination
1 Military standard construction with listings qualified to MIL-S-8805
1 All 4SE switches are UL recognized
and CSA certified
1 4XE switches are UL recognized
ELECTRICAL RATINGS
Circuitry
Electrical Rating Code
Single-Pole
Double-Throw
A 5 amps res., 3 amps ind., (sea level), 5 amps res.,
2.5 amps ind., (50,000 feet) 28 vdc.
5 amps res., 5 amps ind., 125 or 250 vac, 60 Hz.
B UL and CSA Rating
5 amps, 250 vac, 60 Hz
C 7 amps res., 4 amps ind., (sea level),
7 amps res., 2.5 amps ind., (50,000 feet), 28 vdc.
7 amps res., 4 amps ind., (sea level), 115 vac, 400 Hz
1 foot leads
(other lengths
available)
Recommended
For
Electrical
Rating
Code
O.F.
Newtons
ounces
R.F. min.
Newtons
ounces
Characteristics
P.T. max. O.T. min.
mm
mm
inches
inches
D.T. max.
mm
inches
O.P.
mm
inches
Most applications
A
1,39-4,73
5-17
1,11
4
1,27
.050
0,08
.003
0,1
.004
10,8
.425
1SE2
SPST — Normallyclosed
A
1,39-4,73
5-17
1,11
4
1,27
.050
0,08
.003
0,1
.004
10,8
.425
1SE3
SPST — Normallyopen
A
1,39-4,73
5-17
1,11
4
1,27
.050
0,08
.003
0,1
.004
10,8
.425
4SE1
UL and CSA listing
and UL and CSA
listed lead wire
Oil resistant
Fluorosilicone seal
B
1,39-4,73
5-17
1,11
4
1,27
.050
0,08
.003
0,1
.004
10,8
.425
A
1,39-4,73
5-17
1,11
4
1,27
.050
0,08
.003
0,1
.004
10,8
.425
7SE1
Lower force
A
1,11-2,22
4-8
0,56
2
1,27
.050
0,08
.003
0,1
.004
10,8
.425
12SE4-T
High return force
A
1,39-5,28
5-19
1,11
4
1,27
.050
0,08
.003
0,1
.004
10,8
.425
1SE1-T
For customer
leading
A
1,39-4,73
5-17
1,11
4
1,27
.050
0,08
.003
0,1
.004
10,8
.425
Fig. 2
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada
13
Position Sensors
1SE1
5SE1
Fig. 1
E 7 amps res., 4 amps ind., (sea level),
7 amps res., 2.5 amps ind., (50,000 feet), 28 vdc.
R 1 amp res., 0.50 amp ind., 28 vdc.
Characteristics: O.F. — Operating Force; R.F. — Release Force;
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel;
O.P. — Operating Position
SE SWITCHES ORDER GUIDE
Catalog
Listing
D UL Rating
7 amps, 250 vac 60 Hz
Position Sensors
Environment-Sealed Basic Switches
SE Series
AUXILIARY ACTUATORS FOR SE SWITCHES ORDER GUIDE
(Switches are not included with actuators)
Catalog
Listing
Description
Characteristics: O.F. — Operating Force; R.F. — Release Force;
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel;
O.P. — Operating Position
Characteristics measured
with actuators mounted to a 1SE1
Actuator
O.F.
R.F.
P.T.
O.T.
D.T.
Length A
max.
min.
approx.
min.
max.
O.P.
mm
Newtons Newtons
mm
mm
mm
mm
inches
ounces ounces inches
inches inches
inches
F.P.
mm
inches
JE-1
Straight leaf
(mounting
hardware
included)
16,8
.66
3,34
12
0,56
2
3,81
.150
0,38
.015
0,64
.025
11,2
.440
15±0,76
.590±.030
JE-4
Roller leaf.
Roller turned
90° to switch
axis
(mounting
hardware
included).
16,8
.66
3,34
12
0,56
2
3,81
.150
0,38
.015
0,64
.025
16,3
.640
20,1
.790
approx.
JE-5
Roller leaf
(mounting
hardware
included)
14,2
.560
3,34
12
0,56
2
3,81
.150
0,38
.015
0,64
.025
16,3
.640
20,1±0,76
.790±.030
JE-17
Roller leaf.
Reversed
position
(mounting
hardware
included)
14,2
.560
3,34
12
0,56
2
3,81
.150
0,38
.015
0,64
.025
16,3
.640
20,1±0,76
.790±.030
JE-21
Roller lever
13,7
.540
1,67
6
0,28
1
2,54
.100
0,25
.010
0,41
.016
16,3
.640
18,8±0,76
.740±.030
JE-22
Tandem
Roller
Lever
17,8
.700
4,73
17
1,11
4
2,54
.100
0,15
.006
0,3
.012
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
16,8±1,3 19,3±1,3
.660±.050 .760±.050
Fig. 8
14
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada
Position Sensors
Environment-Sealed Basic Switches
XE Series
Characteristics: O.F. — Operating Force; R.F. — Release Force;
P.T. — Pretravel; D.T. — Differential Travel; O.P. — Operating Position.
XE SWITCHES ORDER GUIDE
Characteristics
Catalog
Listing
1 foot leads
(other lengths
available)
Recommended For
Electrical
Rating
Code
O.F.
max.
Newtons
ounces
R.F.
max.
Newtons
ounces
P.T.
max.
mm
inches
O.T.
min.
mm
inches
D.T.
max.
mm
inches
O.P.
mm
inches
±.020 (0,51)
1XE1
(MS27994-1)
Most applications
MIL-S-8805
requirements
C
1,39-4,73
5-17
1,11
4
1,27
.050
0,1
.004
0,13
.005
10,8
.425
1XE201
(MS27994-4)
General Use
MIL-S-8805
requirements
C
1,39-4,73
5-17
1,11
4
1,27
.050
0,1
.004
0,13
.005
10,8
.425
MIL-W-22759/11
wire
1XE3
SPST-Normally Open
C
1,39-4,73
5-17
1,11
4
1,27
.050
0,1
.004
0,13
.005
10,8
.425
1XE301
(MS27994-5)
Gold Contacts
MIL-W-22759/11 wire
R
1,39-4,73
5-17
1,11
4
1,27
.050
0,1
.004
0,13
.005
10,8
.425
4XE1
UL listing and UL and
CSA listed leadwire
D
1,39-4,73
5-17
1,11
4
1,27
.050
0,1
.004
0,13
.005
10,8
.425
5XE1
Oil resistant
Fluorosilicone seal
C
1,39-4,73
5-17
1,11
4
1,27
.050
0,1
.004
0,13
.005
10,8
.425
14XE1
Less operating force
Use to +300°F
(149°C)
E
2,50
9 max.
0,56
2
0,76
.030
0,1
.004
0,13
.005
10,9
.430
14XE1-T
For customer leading
Use to +300°F
(149°C)
E
2,50
9 max.
0,56
2
0,76
.030
0,1
.004
0,13
.005
10,9
.430
1XE1-T
(MS27994-3)
For customer leading
C
1,39-4,73
5-17
1,11
4
1,27
.050
0,1
.004
0,13
.005
10,8
.425
Fig. 9
Fig. 10
Characteristics: O.F. — Operating Force; R.F. — Release
Force; P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential
Travel; O.P. — Operating Position; F.P. — Free Position.
AUXILIARY ACTUATORS FOR XE SWITCHES ORDER GUIDE
(Switches are not included with the actuators)
Characteristics measured with actuator mounted on a 1XE1
R.F.
min.
Newtons
ounces
P.T.
approx.
mm
inches
O.T.
min.
mm
inches
D.T.
max.
mm
inches
O.P.
mm
inches
F.P.
mm
inches
Catalog
Listing
Description
JM-1
Straight leaf
5,84
21
0,83
3
3,18
.125
0,23
.009
0,3
.012
10,8±0,76
.425±.030
14±0,76
.550±.030
JM-5
Roller leaf
5,84
21
0,83
3
3,18
.125
0,23
.009
0,3
.012
15,9±0,89
.625±.035
19,1±0,89
.750±.035
Fig. 11
Fig. 12
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada
15
Position Sensors
O.F.
max.
Newtons
ounces
Position Sensors
Environment-Sealed Basic Switches
SE Series
SE MOUNTING DIMENSIONS (For reference only)
SE switches
MOUNTING HOLES WILL ACCEPT PINS OR
SCREWS OF 22,1/.087 MAX DIA
Fig. 1
Fig. 2
SE auxiliary actuators
Fig. 4
Fig. 5
Fig. 3
Fig. 8
Fig. 6
16
Fig. 7
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada
Position Sensors
Environment-Sealed Basic Switches
XE Series
XE MOUNTING DIMENSIONS (For reference only)
XE switches
Fig. 9
Fig. 10
Fig. 11
Fig. 12
XE auxiliary actuators
Position Sensors
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada
17
Position Sensors
Hermetically Sealed Switches
GENERAL INFORMATION
HS switches are designed for applications
where maximum electrical rating and maximum sealing are essential, and where size
and weight requirements are less critical.
These switches are side mounted through
mounting holes that are outside the sealed
switching chamber.
HS Series
FEATURES
1 Hermetically sealed per MIL-S-8805,
design symbol 5 (–67° to +180°F or
–55° to 82°C)
1 Power load switching capability up to
25 amperes, 28 VDC
1 Temperature tolerance from –67°F to
+250°F (–55°C to +125°C)
1 High temperature construction for use
to +300°F (149°C)
1 Several styles of integral lever
actuators
1 Two styles of terminals
1 Military standard construction with listings on the MIL-S-8805 qualified products list
1 UL recognized File #E12252; CSA certified LR 4442
ELECTRICAL RATINGS
Circuitry
Single-Pole
Double-Throw
Electrical Rating Codes
M 25 amps res., 8 amps ind., 5 amps motor, 3 amps
lamp load, 28 vdc;
1 amp res., 1 amp ind., 115 vac, 60 Hz
UL-CSA Rating: 1 amp., 115 vac, 60 Hz.
N
15 amps res., 8 amps ind., 28 vdc;
1 amp res., 1 amp ind., 115 vac, 60 Hz
O 20 amps res., 8 amps ind., 28 vdc;
1 amp res., 1 amp ind., 115 vac, 60 Hz
UL-CSA Rating: 1 amp, 115 vac, 60 Hz
P
22
10 amps res., 5 amps ind., 28 vdc;
1 amp res., 1 amp ind., 115 vac, 60 Hz
UL-CSA Rating: 1 amp., 115 vac, 60 Hz.
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada
Position Sensors
Hermetically Sealed Switches
HS Series
Characteristics: O.F. — Operating Force; R.F. —
Release Force; P.T. — Pretravel; O.T. — Overtravel; D.T.
— Differential Travel; O.P. — Operating Position.
HS ORDER GUIDE
Operating Characteristics
Electrical O.F. max. R.F. min. P.T. max. O.T. min. D.T. max.
Rating
Newtons Newtons
mm
mm
mm
Code
ounces ounces
inches
inches
inches
O.P.
mm
inches
Catalog
Listing
Recommended For
1HS1
(MS25011-1)
Most applications
MIL-S-8805 (M8805/47)
M
2,78-6,12
10-22
1,11
4
1,65
.065
0,25
.010
0,51
.020
13,5 ± 0,38
.530 ± .015
101HS1
Operating in
temperatures to
+250°F (121°C)
O
2,78-6,12
10-22
1,11
4
1,65
.065
0,25
.010
0,51
.020
13,5 ± 0,38
.530 ± .015
102HS1
Operating in
temperatures to
+300°F (149°C)
P
2,78-8,34
10-30
1,11
4
1,65
.065
0,25
.010
0,51
.020
13,5 ± 0,38
.530 ± .015
4HS4-118
Lead wire termination
N
2,78-6,12
10-22
1,11
4
1,65
.065
0,25
.010
0,51
.020
15,6
.615±
.020
1HS41
Applications requiring
added overtravel
M
1,11-5,56
4-20
0,56
2
—
1,57
.062 max.
2,54
.100
13,54
.533
approx.
1HS6
(MS25011-4)
MIL-S-8805
requirements. More
operating force
M
6,12-7,78
22-28
1,11
4
2,16
.085
0,25
.010
0,51
.020
13,5 ± 0,38
.530 ± .015
1HS3
Roller lever
M
2,78-6,12
10-22
1,11
4
1,65
.065
0,25
.010
0,51
.020
18,3 ± 0,38
.720 ± .015
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
HS MOUNTING DIMENSIONS (For reference only)
Fig. 1
Fig. 2
Fig. 4
Fig. 5
Position Sensors
Mounting holes will accept pins or screws of .139N (3,53mm) diameter.
Fig. 3
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada
23
Position Sensors
Miniature Hermetically Sealed Switches
GENERAL INFORMATION
HM switches are not generally recommended for 115 VAC, 60 Hz. If you have a
60 Hz application in the milliamp range,
contact our 800 number for special design variations that are available.
HM Series
FEATURES
1 Hermetically sealed per enclosure design symbol 5, MIL-S-8805
1 Power load switching capability up to 4
amperes, 28 VDC and 2 Amps 115 VAC,
400 Hz
1 Temperature tolerance from –85°F to
+250°F (–65°C to +121°C)
1 High temperature construction for use
from –85°F to +500°F (–65°C to
+260°C)
1 Variety of auxiliary actuators
1 Choice of terminal styles
1 Gold contacts for special applications
1 Military standard construction with listings on the MIL-S-8805 qualified products list.
ELECTRICAL RATINGS
Circuitry
Electrical Rating Code
Single-Pole
Double-Throw
H
1 amp res., 0.25 amp ind., 28 VDC.
Single-Pole
Double-Throw
I
2 amps res., 2 amps ind., 0.5 amps lamp load, 115 VAC,
400 Hz.
4 amps res., 2 amps ind., 1 amp lamp load, 28 VDC
Single-Pole
Double-Throw
J
1
Single-Pole
Double-Throw
K
3 amps res., 1 amp ind. (sea level or 70,000 ft.), 28 VDC
1 amp res. or ind. (sea level), 115 VAC., 400 Hz.
Single-Pole
Double-Throw
L
3 amp res., 1 amp ind., 28 VDC
1 amp res., 1 amp ind., 115 VAC, 400 Hz.
⁄2 amp res., 1⁄4 amp ind. (sea level or 70,000 ft.),
28 VDC
APPLICATION NOTES
1. Honeywell does not recommend the use of silver cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally loads less than 12 volts and/or 0.5
amp. Catalog listings in the 5, 6, 15, and 16HM Series use silver cadmium oxide contacts. If you
have specific questions, contact the MICRO SWITCH Application Center at 1-800-537-6945.
2. For applications involving non-arcing loads, catalog listings in the 9, 10, 19 and 20HM Series
are recommended.
3. The 1, 2, 5, and 6HM Series are recommended for use only in 3 to 4 amp range applications.
18
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada
Position Sensors
Miniature Hermetically Sealed Switches
HM Series
Characteristics: O.F. — Operating Force; R.F. — Release Force;
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel;
O.P. — Operating Position.
HM ORDER GUIDE
Operating Characteristics
Catalog
Listing
Recommended For
Electrical
Rating
Code
O.F. max. R.F. min.
Newtons Newtons
ounces
ounces
P.T. max.
mm
inches
O.P.
O.T. min. D.T. max.
mm
mm
mm
inches
inches
inches ±.015 (0,38 mm)
11HM1
(MS27216-5)
Most applications.
Exceeds MIL-S-8805
requirements for
shock and vibration.
K
1,95
7
0,28
1
0,76
.030
0,08
.003
0,15
.006
8,38
.330
13HM1
Applications requiring
gold contacts
H
1,95
7
0,28
1
0,76
.030
0,08
.003
0,15
.006
8,38
.330
9HM1
(MS27216-6)
Bifurcated gold
contacts
J
1,95
7
0,28
1
0,76
.030
0,08
.003
0,15
.006
8,38
.330
2HM19-1
(MS27216-2)
MIL-S-8805
application
requirements 1 ft.
(305mm) leads
I
1,95
7
0,28
1
0,76
.030
0,08
.003
0,15
.006
8,38
.330
2HM19-5
(MS27216-4)
5 foot (1524mm) long
leads
I
1,95
7
0,28
1
0,76
.030
0,08
.003
0,15
.006
8,38
.330
16HM1-1
High temperature to
500°F (260°C) flat
spring
L
1,95
7
0,28
1
0,76
.030
0,08
.003
0,15
.006
8,38
.330
15HM2
Operating in
temperatures to
+500°F (260°C) with
weld tab termination.
L
1,95
7
0,28
1
0,76
.030
0,08
.003
0,15
.006
8,38
.330
Fig. 1
Fig. 2
Fig. 3
Position Sensors
Fig. 4
HM MOUNTING
A force spreading plate is recommended to reduce the
chance of product damage due to excessive mounting force.
MOUNTING PLATE
19PA137-HM
NOTICE
Torque on #2 mounting screws must be restricted to 1.5 inch
pounds max. to prevent switch damage. The force spreading
mounting plate used as shown will allow up to 2.5 inch
pounds of mounting torque.
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada
19
Position Sensors
Miniature Hermetically Sealed Switches
HM Series
Characteristics: O.F. — Operating Force; R.F. — Release Force;
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel;
O.P. — Operating Position; F.P. — Free Position.
AUXILIARY ACTUATORS FOR HM SWITCHES ORDER GUIDE
(Switches are not included)
Operating Characteristics with Actuator Mounted on a 6HM1-1
Catalog
Listing
Description
JS-254
Leaf
Temp.
(Max.)
O.F. max. R.F. min.
Newtons Newtons
ounces
ounces
P.T. max.
mm
inches
O.T. min. D.T. max.
mm
mm
inches
inches
O.P.
mm
inches
F.P.
mm
inches
500°F
(260°C)
2,50
9
0,56
2
—
0,76
.030
0,76
.030
8,64
12,2
.340 approx. .480 approx.
500°F
(260°C)
2,50
9
0,56
2
—
0,76
.030
0,76
.030
14
17,5
.550 approx. .690 approx.
JS-307
Straight lever 500°F
(260°C)
0,42
1.5
0,03
.11
3,18
.125
approx.
0,64
.025
1,42
.056
10,3
.406 approx.
JS-308
Roller lever
0,42
1.5
0,03
.11
3,18
.125
approx.
0,64
.025
1,42
.056
14,3
.562 approx.
Fig. 5
JS-151
Roller leaf
Fig. 6
Fig. 7
500°F
(260°C)
Fig. 8
MOUNTING TORQUE:
JS-254 2.5 inch pounds
all others 1.5 inch pounds
See optional mounting plate – previous
page.
20
All standard JS actuators in the SM Section of Catalog 10 can be used with the
HM line. However, hardware, insulator,
and oil impregnated roller supplied with
these actuators may not provide the required service at temperatures above
250°F (121°C).
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada
Position Sensors
Miniature Hermetically Sealed Switches
HM Series
HM MOUNTING DIMENSIONS (For reference only)
Pin plunger switches
Fig. 1
Fig. 2
MOUNTING HOLES WILL ACCEPT PINS OR
SCREWS OF 1,9/.08 DIA
Fig. 4
Fig. 3
Auxiliary actuators
Position Sensors
Fig. 5
Fig. 6
Fig. 8
Fig. 7
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada
21
Position Sensors
High Temperature Basic Switches
HT Series
GENERAL INFORMATION
HT switches will withstand temperatures
up to +1000F. The switching element is
mounted on a ceramic base within a
stainless steel enclosure. HT switches are
not classified as sealed switches.
FEATURES
1 Temperature tolerance up to +1000°F
(538°C)
1 Designed to meet military applications
1 Side and panel mount
1 UL recognized
ELECTRICAL RATINGS
Circuitry
Single-Pole
Double-Throw
Electrical Rating
UL Ratings:
3 amps, 1/10 HP, 125 vac.
3 amps, 1/6 HP, 250 vac.
Characteristics: O.F. – Operating Force; R.F. – Release Force;
P.T. – Pretravel; O.T. – Overtravel; O.P. – Operating Position
HT ORDER GUIDE
Catalog Listing
Description
O.F.
newtons
ounces
R.F. min.
newtons
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
O.P.
mm
inches
1HT1
Straight plunger panel
mount
2,78-5,56
10-20
1,67
6
1,65
.065
4,78
.188
23,7
.935
approx.
3HT1
Roller plunger panel
mount
8,34
30 max.
1,67
6
1,65
.065
4,78
.188
35,9
1.413
approx.
2HT1
Pin plunger side mount
2,78-5,56
10-20
1,67
6
1,27
.050
0,25
.010
16,8
.66
approx.
Fig. 1
Fig. 2
Fig. 3
HT MOUNTING DIMENSIONS (For reference only)
Fig. 1
Mounting holes will accept pins or
screws of .139N (3,53 mm) dia.
24
Fig. 2
Fig. 3
Honeywell Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-416-293-8111 Canada
MT Series
FEATURES
1 Arc resistant case
1 Mechanical life of 100,000 operations
— 95% survival
1 Temperature tolerance to +180°F
(82°C)
1 Mounting interchangeability with Z
switches
1 UL recognized
GENERAL INFORMATION
MT (single-pole double-throw) magnetic
blow-out switches are designed to switch
high capacity (125 and 250 VDC) systems. An integral magnet around the contact gap protects the contacts by deflecting the arc. Vents between the cover and
housing allow the hot gas to escape.
These switches are designed for the control of DC motors, solenoids, etc.
AVAILABLE TERMINALS
Solder (No listing designation)
A28
6-32NC H .218N Screws
will accept up to #12 wire.
ELECTRICAL RATING
Electrical Data and
UL Codes
Circuitry
Single-pole
double-throw
unless
otherwise noted
in order guide
K Rating established with
switch non-polarized
10 amps, 125 vac or vdc;
1/4 hp, 125 vac or vdc.
UL Code L 168
Non-polarized:
10 amps res. or 1/4 hp, 125 vdc;
3 amps max. res. 250 vdc.
Polarized*:
10 amps res. or 1/2 hp, 125 vdc;
3 amps max. res., 250 vdc.
*To polarize, connect negative side of line to common terminal. To
achieve the same effect, mount switch with brass screws, using a
non-magnetic barrier (at least 1⁄4 N thick) between the switch and
mounting surface.
Characteristics: O.F. – Operating Force;
R.F. – Release Force; P.T. – Pretravel;
O.T. – Overtravel; D.T. – Differential Travel;
O.P. – Operating Position.
ORDER GUIDE
Catalog Listing
MT-4R-A28
Recommended For
Pin plunger
SPDT
Electrical
Data and
UL Codes
O.F.
newtons
ounces
R.F. min.
newtons
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T. max.
mm
inches
O.P.
mm
inches
10 Amps
K
3,34-5,0
12-18
1,39
5
1,02
.04
0,13
.005
0,1-0,18
.004-.007
15,9±0,38
.625±.015
Dim. Dwg. Fig. 1
70
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Basic Switches
Magnetic Blow-out
MT Series
ORDER GUIDE
Catalog Listing
Description
Electrical O.F. max.
Data and newtons
UL Codes ounces
R.F. min.
newtons
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T. max.
mm
inches
O.P.*
mm
inches
MT-4RV-A28
Straight lever
10 Amps
K
0,56
2
0,14
0.5
12,7
0.5
1,19
.047
2,16
.085
19,1
.750
MT-4RV2-A28
1.90 inch (48,3mm) lever
with hardened steel roller
10 Amps
K
0,76
2.75
0,07
0.25
8,89
0.35
0,79
.031
1,65
.065
30,2
1.188
MT-4RV22-A28
1.03 inch (26,2mm) lever
with hardened steel roller
10 Amps
K
1,25
4.5
0,28
1
5,08
.200
0,38
.015
0,89
.035
31,3
1.234
MT-4RL-A28
1.95 inch (49,5mm)
flexible leaf
10 Amps
K
3,34
12
0,28
1
—
1,52
.060
max.
—
19,1
.750
1.82 inch (46,2mm)
flexible leaf with hardened
steel roller
10 Amps
K
3,34
12
0,28
1
—
1,52
.060
max.
—
30,2
1.188
Dim. Dwg. Fig. 2
Dim. Dwg. Fig. 3
Dim. Dwg. Fig. 4
Dim. Dwg. Fig. 5
For application help: call 1-800-537-6945.
Except where stated * ±0,76 mm
±.030 in.
Honeywell Sensing and Control
71
Standard
Basic Switches
MT-4RL2-A28
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Basic Switches
Magnetic Blow-out
MT Series
MOUNTING DIMENSIONS (For reference only)
PIN PLUNGER
STRAIGHT LEVER
Fig. 1
Fig. 2
ROLLER LEVER
FLEXIBLE LEAF
Fig. 3
Fig. 4
FLEXIBLE ROLLER LEAF
Fig. 5
Mounting holes accept pins or screws of
.139 N (3,53 mm) diameter.
72
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Basic Switches
Magnetic Blow-out
Obsolete
V3 Series
CUT-A-WAY V3 MINIATURE BASIC SWITCH
GENERAL INFORMATION
V3 miniature basic switches feature high
electrical capacity and long life. Their size
and shape meet design requirements in
all types of applications.
There is a choice of SPDT, SPNC, and
SPNO circuitry. Many lever styles, contact
materials, and terminal variations can be
furnished. Contact the 800 number for ordering information.
FEATURES
1 Low operating force to .53 ounce
maximum
1 Sensitive differential travel as low as
.006 inch maximum
1 Power load switching capability up to
25 amperes–silver contacts
1 Gold alloy crosspoint, silver cadmium,
and other contact material for special
applications
1 Long mechanical life of 10,000,000 cycles—95% survival for V3-100, V3-1100,
V3-2100, V3-3000 Series
1 Temperature tolerance up to +180°F
(82°C) on standard construction
1 High temperature construction for use
up to +600°F (316°C)
1 3,1 mm mounting holes available
1 UL recognized File #E12252, CSA certified File #LR41370
AVAILABLE TERMINALS
SOLDER
D8
SHORT SOLDER
QUICK CONNECT
SCREW
D9
Dimensions shown are for reference only
.188 wide × .020 thick terminals
.250 wide × .032 thick terminals
Mounting torque:
2 inch pounds min.
5 inch pounds max.
This section covers only 60 of our most popular V3 Series catalog listings. If you don’t find what you’re looking for, it’s likely
one of the approximately 850 other active V3 listings will meet your needs. Contact the 800 number.
32
Honeywell 1 MICRO SWITCH Sensing and Control
For application help: call 1-800-537-6945.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Basic Switches
Miniature
Obsolete
PIN PLUNGERS
V3 Series
Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. –
Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating
Position.
ORDER GUIDE by ascending electrical capability
Catalog
Listing
Dim. Dwg. Fig. 1
Recommended For
R.F.
O.F.
min.
newtons newtons
ounces
ounces
P.T.
max.
mm
inches
O.T.
min.
mm
inches
D.T.
mm
inches
O.P.**
mm
inches
V3-343-D8
General use. Gold
alloy crosspoint
contacts.
1 Amp
X
2,22
8 max.
0,56
2
1,2
.047
1,02
.040
0,15-0,41
.006-.016
14,7
.578
V3-2451-D8
Lowest force.
3 Amps
VV
0,15
.53
—
1,2
.047
1,27
.050
0,051-0,25
.002-.010
14,7
.578
V3-2401-D8
Lower force.
5 Amps
YY
0,24
.9
—
1,2
.047
1,27
.050
0,051-0,25
.002-.010
14,7
.578
V3-70101-D8
Most 5 amp
applications.
5 Amps
ZZ
2,22
8
0,56
2
1,2
.047
1,02
.040
0,15-0,41
.006-.016
14,7
.578
V3-1101-D8
General use.
10 Amps
TT
0,72 max.
2.6
0,10
.35
1,2
.047
1,27
.050
0,051-0,25
.002-.010
14,7
.578
V3-2101-D8
Low force.
10 Amps
V
0,50 max.
1.8
0,05
.18
1,2
.047
1,27
.050
0,051-0,25
.002-.010
14,7
.578
V3-101-D8
Higher force. Most
applications.
11 Amps
T
2,22
8 max.
0,56
2
1,2
.047
1,02
.040
0,15-0,41
.006-.016
14,7
.578
V3-1-D8
Highest force. Up to
15.1 amps load
handling with reduced
life.
15.1 Amps
U
1,67-3,89
6-14
1,11
4
1,21
.047
1,0
.040
0,15-0,4
.006-.016
14,7
.578
V3-3001-D8
High force. Up to 15.1
amps load handling.
15,1 Amps
U
1,47 max.
5.3
0,15
.53
1,2
.047
1,27
.050
0,051-0,25
.002-.010
14,7
.578
V3-2800-D9
Up to 20 amps load
handling
20 Amps
AA
0,63 - 1,22
2.3 - 4.4
0,20
0.7
1,2
.047
1,27
.050
0,25
.010 max.
14,7
.578
V3-2900-D9
Up to 25 amps load
handling
25 Amps
BB
1,22 - 2,20
4.4 - 7.9
0,31
1.1
1,2
.047
1,27
.050
0,25
.010 max
14,7
.578
V3-1001
(MS25253-1)
MIL-S-8805 application
requirements (SPDT)
10 Amps
UU
1,67-3,89
6-14
1,11
4
1,2
.047
1,02
.040
0,15-0,41
.006-.016
14,7
.578
V3-1002
(MS25253-3)
MIL-S-8805 application
requirements (SPNC)
10 Amps
UU
1,67-3,89
6-14
1,11
4
1,2
.047
1,02
.040
0,15-0,41
.006-.016
14,7
.578
V3-1003
(MS25253-2)
MIL-S-8805 application
requirements (SPNO)
10 Amps
UU
1,67-3,89
6-14
1,11
4
1,2
.047
1,02
.040
0,15-0,41
.006-.016
14,7
.578
V3-129*
Operating in
temperature to
+302°F (150°C)
11 Amps
T
2,22
8 max.
0,56
2
1,2
.047
1,02
.040
0,15-0,41
.006-.016
14,7
.578
V3-245*
Operating in
temperature to
+400°F (204°C)
10 Amps
W
2,78-6,95
10-25
1,67
6
1,2
.047
1,02
.040
0,15-0,41
.006-.016
14,7
.578
Miniature/
Subminiature
Dim. Dwg. Fig. 2
Electrical
Data And
UL Code
Page 20
**Tolerances ±0.38
±0.15
*For actuators, contact MICRO SWITCH Sales Office.
ORDER GUIDE
SIMULATED
ROLLER
Catalog
Listing
Electrical Length of
O.F.
R.F.
P.T.
Data And Lever ‘‘A’’ max.
min.
max.
mm
newtons newtons mm
UL Code
Recommended For Page 20
inches
ounces ounces inches
O.T.
min.
mm
inches
D.T.
max.
mm
inches
O.P.*
mm
inches
V3L-1123-D8
General use.
10 Amps
TT
32,6
1.285
0,39
1.4
0,05
.18
2,54
.100
2,03
.080
0,76
.030
18,5
.730
V3L-2105-D8
Low force.
10 Amps
V
32,6
1.285
0,33
1.2
0,02
.07
2,54
.100
2,03
.080
0,76
.030
18,5
.730
V3L-121-D8
High force. Most
applications.
11 Amps
T
32,6
1.285
1,11
4
0,14
.5
3,18
.125
1,57
.062
0,81
.032
18,5
.730
V3L-5-D8
Highest force. Up to
15.1 amps load
handling with
reduced life.
15.1 Amps
U
32,6
1.285
2,22
8
0,28
1
3,18
.125
1,57
.062
0,81
.032
18,5
.730
V3L-3014-D8
High force. Up to
15.1 amps load
handling.
15.1 Amps
U
32,6
1.285
0,94
3.4
0,07
.25
2,54
.100
1,90
.075
0,76
.030
18,5
.730
Dim. Dwg. Fig. 3
*±1.5 mm
±.060 in.
For application help: call 1-800-537-6945.
Honeywell 1 MICRO SWITCH Sensing and Control
33
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Basic Switches
Miniature
Obsolete
V3 Series
ORDER GUIDE
STRAIGHT LEVERS
Catalog
Listing
Dim. Dwg. Fig. 4
Dim. Dwg. Fig. 4
Dim. Dwg. Fig. 4
Dim. Dwg. Fig. 4
34
Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating Position.
Electrical Length of
O.F.
R.F.
P.T.
O.T.
D.T.
min.
max.
min.
max.
Data And Lever ‘‘A’’ max.
UL Code
mm
newtons newtons mm
mm
mm
Recommended For Page 20
inches ounces ounces inches inches inches
O.P.
mm
inches
V3L-1105-D8
General use.
10 Amps
TT
21,3
.860
0,72
2.6
0,10
.35
1,5
.060
1,14
.045
0,33
.013
15,2±0,51
.600±.020
V3L-2101-D8
Low force. Added
overtravel.
10 Amps
V
21,3
.860
0,50
1.8
0,50
.18
1,5
.060
1,14
.045
0,33
.013
15,2±0,51
.600±.020
V3L-101-D8
Higher force. Most
applications.
11 Amps
T
21,3
.860
2,50
9
0,56
2
1,5
.060
1,02
.040
0,41
.016
15,2±0,51
.600±.020
V3L-1-D8
Highest force. Up to
15.1 amps load
handling with
reduced life.
15.1 Amps
U
21,3
.860
3,89
14
0,83
3
1,5
.060
1,02
.040
0,41
.016
15,2±0,51
.600±.020
V3L-3001-D8
High force. Up to
15.1 amps load
handling.
15.1 Amps
U
21,3
.860
1,47
5.3
0,15
.53
1,5
.060
1,02
.040
0,28
.011
15,2±0,51
.600±.020
V3L-1108-D8
General use.
10 Amps
TT
35,6
1.40
0,39
1.4
0,04
.14
2,79
.110
2,29
.090
0,76
.030
15,2±1,5
.600±.060
V3L-2102-D8
Low force.
10 Amps
V
35,6
1.40
0,31
1.1
0,02
.07
2,79
.110
2,29
.090
0,76
.030
15,2±1,5
.600±.060
V3L-104-D8
Higher force. Most
applications.
11 Amps
T
35,6
1.40
1,11
4
0,14
.5
3,18
.125
2,29
.090
1,27
.050
15,2±1,5
.600±.060
V3L-2-D8
Highest force. Up to
15.1 amps load
handling with
reduced life.
15.1 Amps
U
35,6
1.40
2,22
8
0,28
1
3,18
.125
2,29
.090
1,27
.050
15,2±1,5
.600±.060
V3L-3005-D8
High force. Up to
15.1 amps load
handling.
15.1 Amps
U
35,6
1.40
.86
3.1
0,06
.21
3,05
.120
2,29
.090
0,81
.032
15,2±1,5
.600±.060
V3L-2425-D8
Lower force.
5 Amps
YY
59,4
2.34
0,07
.25
—
5,08
.200
4,06
.160
1,4
.055
15,2±2
.600±.080
V3L-1122-D8
General use.
10 Amps
TT
59,4
2.34
0,22
.81
0,02
.07
5,08
.200
4,06
.160
1,4
.055
15,2±1,8
.600±.070
V3L-2106-D8
Low force.
10 Amps
V
59,4
2.34
0,16
.56
0,01
.04
5,08
.200
4,06
.160
1,4
.055
15,2±1,8
.600±.070
V3L-131-D8
Higher force. Most
applications.
11 Amps
T
59,4
2.34
0,58
2.1
0,12
.42
6,6
.260
3,81
.150
2,29
.090
14,7±2
.580±.080
V3L-6-D8
Highest force. Up to
15.1 amps load
handling with
reduced life.
15.1 Amps
U
59,4
2.34
1,11
4
0,14
.50
6,95
2.60
3,81
.150
2,29
.090
14,35±1,5
.565±.060
V3L-3013-D8
High force. Up to
15.1 amps load
handling.
15.1 Amps
U
59,4
2.34
0,39
1.4
0,03
.11
5,33
.210
4,06
.160
1,52
.060
15,2±1,9
.600±.075
V3L-2472-D8
Lowest force.
3 Amps
VV
69,45
2.75
0,03
.11
—
—
5,97
.235
5,08
.200
1,60
.063
15,2±2,54
.600±.100
V3L-1124-D8
General use.
10 Amps
TT
69,45
2.75
0,19
.70
0,01
.04
7,74
.305
3,68
.145
1,65
.065
15,31±2,54
.603±.100
V3L-145-D8
Most applications.
11 Amps
T
69,45
2.75
0,54
1.93
0,10
.36
0,76
.300
4,57
.180
2,54
.100
14,48±2,03
.570±.080
V3L-14-D8
Highest force. Up to
15.1 amps load
handling with
reduced life.
15.1 Amps
U
69,45
2.75
0,83
3
0,14
.50
8,38
.330
4,32
.170
2,54
.100
13,72±2,03
.540±.080
Honeywell 1 MICRO SWITCH Sensing and Control
For application help: call 1-800-537-6945.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Basic Switches
Miniature
Obsolete
V3 Series
ORDER GUIDE
ROLLER LEVERS
Catalog
Listing
Recommended
For
Electrical Length of
Data And Lever ‘‘A’’
UL Codes
mm
Page 20
inches
O.F. max.
newtons
ounces
R.F. min.
newtons
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T. max.
mm
inches
O.P.
mm
inches
General use.
10 Amps
TT
20,6
.81
0,89
3.2
0,10
.35
1,2
.047
1,14
.045
0,33
.013
20,6±0,76
.810±.030
V3L-2103-D8
Low force.
10 Amps
V
20,6
.81
0,58
2.1
0,03
.11
1,42
.056
0,86
.034
0,33
.013
20,6±0,76
.810±.030
V3L-139-D8
Higher force.
Most applications.
11 Amps
T
20,6
.81
2,22
8
0,56
2
1,5
.060
1,02
.040
0,41
.016
20,6±0,76
.810±.030
V3L-3-D8
Highest force.
15.1 Amps
Up to 15.1 amps
U
load handling with
reduced life.
20,6
.81
3,89
14
0,83
3
1,52
.060
1,02
.040
0,41
.016
20,6±0,76
.810±.030
V3L-3003-D8
High force.
Up to 15.1 amps
load handling.
15.1 Amps
U
20,6
.81
1,89
6.8
0,15
.53
1,2
.047
1,02
.040
0,05 - 0,25
.002 - .010
20,6±0,76
.810±.030
V3L-1101-D8
General use.
10 Amps
TT
34
1.34
0,44
1.6
0,04
.14
3,18
.125
2,16
.085
0,76
.030
20,6±1,5
.810±.060
V3L-2104-D8
Low force.
10 Amps
V
34
1.34
0,31
1.1
0,02
.07
3,18
.125
2,16
.085
0,76
.030
20,6±1,5
.810±.060
V3L-111-D8
Higher force.
Most applications.
11 Amps
T
34
1.34
1,11
4
0,14
.5
3,18
.125
2,16
.085
1,27
.050
20,6±1,5
.810±.060
V3L-4-D8
Highest force.
15.1 Amps
Up to 15.1 amps
U
load handling with
reduced life.
34
1.34
2,22
8
0,28
1
3,18
.125
2,16
.085
1,27
.050
20,6±1,5
.810±.060
V3L-3004-D8
Higher force.
Up to 15.1 amps
load handling.
34
1.34
0,89
3.2
0,14
.5
3,18
.125
2,16
.085
0,76
.030
20,6±1,5
.810±.060
Dim. Dwg. Fig. 7
Dim. Dwg. Fig. 7
15.1 Amps
U
Characteristics: O.F. — Operating Force; O.T. — Overtravel; D.T. — Differential Travel; R.F. — Release
Force; P.T. — Pretravel; O.P. — Operating Position; F.P. — Free Position.
* Characteristics taken with actuator assembled on Catalog Listing V3-1 switch as shown.
AUXILIARY
ACTUATORS
ORDER GUIDE - SWITCHES ARE NOT INCLUDED WITH ACTUATORS
Catalog
Listing
Description
Actuator
Length ‘‘A’’ O.F. max
mm
newtons
inches
ounces
R.F. min.
newtons
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T. max.
mm
inches
O.P.
mm
inches
F.P. max.
mm
inches
JV-1
Leaf type
21,3
.84
3,34
12
1,11
4
1,19
.047
0,79
.031
0,41
.016
15±0,38
.590±.015
16,4
.645
JV-7
Long leaf
32,3
1.27
2,50
9
1,11
4
1,57
.062
1,27
.050
0,64
.025
14,5±0,76
.570±.030
17,4
.685
JV-5
Roller leaf
20,6
.81
3,34
12
1,11
4
1,52
.060
0,79
.031
0,41
.016
20,3±0,64
.800±.025
22,1
.870
Dim. Dwg. Fig. 11
Dim. Dwg. Fig. 11
Dim. Dwg. Fig. 11
NOTE: Contact a MICRO SWITCH Sales Office for application assistance when actuators will be used at temperatures above 300°F (149°C).
For application help: call 1-800-537-6945.
Honeywell 1 MICRO SWITCH Sensing and Control
35
Miniature/
Subminiature
V3L-1117-D8
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Basic Switches
Miniature
Obsolete
V3 Series
Characteristics: O.F. — Operating Force;
R.F. — Release Force; P.T. — Pretravel;
O.T. — Overtravel; D.T. — Differential Travel;
O.P. — Operating Positon; F.P. — Free Position
* Characteristics taken with actuator assembled on Catalog Listing V3100 switch as shown.
AUXILIARY
ACTUATORS
Switches are not included
with actuators
ORDER GUIDE - SWITCHES ARE NOT INCLUDED WITH ACTUATORS
Catalog
Listing
Description
Actuator
Length ‘‘A’’ O.F. max.
mm
newtons
inches
ounces
R.F. min.
newtons
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T. max.
mm
inches
O.P.
mm
inches
F.P. max.
mm
inches
JV-26
Long lever
44,5 †
1.75
0,39
1.4
0,06
.21
8,33
.328
3,58
.141
4,75
.187
12,7±3,18
.500±.125
—
JV-20
Roller lever
19,1 †
.750
0,83
3
0,14
.5
4,78
.188
1,57
.062
1,98
.078
19,5±1,4
.766±.055
23,8
.936
JV-220
Roller lever
17,7 †
.695
0,83
3
0,14
.5
4,78
.188
1,57
.062
1,98
.078
19,5±1,1
.766±.045
23,8
.936
JV-30
One-way roller
lever
20,6
.81
3,34
12
1,11
4
2,03
.080
0,51
.020
0,38
.015
25,7±0,76
1.010±.030
27,7
1.09
JV-91**
Tandem leaf
20,6
.81
5,00
18
1,67
6
1,57
.062
0,89
.035
–
14,9±0,76
.588±.030
16,5
.650
JV-82**
Tandem roller
leaf
20,6
.81
5,00
18
1,67
6
1,57
.062
0,89
.035
–
20,5±0,76
.806±.030
21,8
.860
Dim. Dwg. Fig. 14
Dim. Dwg. Fig. 14
Dim. Dwg. Fig. 14
Dim. Dwg. Fig. 11
Dim. Dwg. Fig. 17
NOTE: Contact the 800 number for application assistance when actuators will be used at temperatures above 300°F (149°C).
** Travel characteristics on tandem actuators vary with actual basic switch characteristics. These shown are typical for the
assembly.
† ‘‘A’’ measurement is from the pivot point of lever to the point indicated on drawing.
Dim. Dwg. Fig. 17
36
Honeywell 1 MICRO SWITCH Sensing and Control
For application help: call 1-800-537-6945.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Basic Switches
Miniature
Obsolete
V3 Series
MOUNTING DIMENSIONS (for reference only)
PIN PLUNGERS
Fig. 1
SIMULATED ROLLER
Fig. 2
STRAIGHT LEVER
ROLLER LEVER
Miniature/
Subminiature
Fig. 3
Fig. 4
Fig. 7
AUXILIARY ACTUATORS
Fig. 11
Fig. 14
NOTE: Operate point dimensions taken
at top of lever/roller.
Fig. 17
For application help: call 1-800-537-6945.
Honeywell 1 MICRO SWITCH Sensing and Control
37
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Basic Switches
Miniature
BASIC SWITCHES
V5 Series
Miniature Basic Switches
V5 Series Basic Switches are used for simple or
precision on/off, end of limit, presence/absence,
pressure, temperature and manual operato r
interface application needs .
Voltage :
250 Vac
Operating temperature :
Standard
-55 °C to 85 ° C
-67 °F to 185 ° F
High temperature
-55 °C to 150 ° C
-67 °F to 302 ° F
Termination :
6,3 mm x 0,8 mm Quick connect
(QC )
Contact type :
Silver/silver cadmium oxid e
Electrical rating :
V5 A
20 A
V5B/P/ R
16 A
V5C/ D
10 A
22 A
V5S
Switching options :
SPDT
Single Pole Double Throw
Straight /ever
Typ e
20, 6
1, 6
(P .T .)
22
A
20, 6
(O .P. )
15, 3
(O .P.)
APPROVALS
CE, CSA, ENEC, U L
REFERENCE
V5CO10BB3B
REFERENCE
V5B210CB3 D
V5C010BB3 D
H
TI
3, 2
(P.T .)
3 .2
34
(T
h
35,6
a
20 .6
(O .P .)
15, 3
(O .P .)
OPTIONS
High temperature
Type E
Type C
PI
APPROVALS
CE, CSA, ENEC. UL
CE, CSA . ENEC. UL
Top pin plunger
APPROVAL S
CE, ENE C
High temperature
REFERENC E
V5B210CB1 C
59, 5
s.1 ►
APPROVALS
CE ENEC
CE, CSA, ENEC, UL
CE, CSA, UL
CE, ENEC
CE, ENEC
CE, ENEC
CE, CSA . ENEC . UL
CE, CSA . ENEC . UL
CE, ENEC
APPROVALS
CE ENEC
CE . ENEC
CE, BEAB
CE, BEAB
-14,1-,
4,8 mm x 0,5 mm OC
Solder terminals
High temperature
4,8 mm x 0,5 mm OC
Solder terminals
SWITCHING OPTIONS
SPNO
SPNO
SPNC
SPNO
REFERENC E
V5A010C B
V5BO10C8 3
V5BO10FB3
V5BO10T 0
V5B210C B
V5CO10B B
V5C010EB 3
V5CO10TB 3
V5PO10CB
Lever position 2
High temperature
REFERENC E
V5A010CB4 E
V5B210CB1 E
I
Type
►i2,8r
APPROVALS
CE. CSA, ENEC . UL
CE. ENEC
APPROVAL S
CE, ENEC
REFERENC E
V5CO10BB1 G
REFERENC E
V5DO30B B
V5R030C B
V5S020C B
V5SO30CB
Honeywel l
www .honeywell .com/sensing
Basic Switches
Miniature
V7 Series
CUTAWAY V7 MINIATURE BASIC SWITCH
FEATURES
1 Quick-connect and printed wiring
board termination
1 Proven V3 switching mechanism
1 Physically interchangeable with existing V3 switches
1 All existing V3 lever options available
1 UL recognized File # E12252; CSA certified File # LR41370
1 International listings carry VDE
approval
1 Power load switching capability up to
21 amps
1 Temperature tolerance –40° to 185°F
(–40° to 85°C)
1 High temperature construction
available—350°F
APPLICABLE EUROPEAN SYMBOLS
µ = microgap construction. (The
measurement between open
contacts is less than 3mm).**
` = alternating current (used with
value of voltage source:
250V `).
T = maximum rated use
temperature; followed by the
temperature value in °C
(example T 85).
+++ = switch is rated for at least
50,000 cycles at its rated
current. (Sometimes referred
to as ‘‘frequent’’ operation.)
10(3) = first number represents
resistive rating. Second
number represents inductive
(motor) rating.
GENERAL INFORMATION
The V7 Series is available in two versions,
the Timesaver series and the International
series. The Timesaver series is UL recognized and CSA certified. Timesaver series
switches use readily available high-volume components to provide especially
responsive delivery performance. The International V7 provides VDE approval in
addition to UL recognition and CSA certification.
The V7 offers a choice of four quick-connect and two printed wiring board terminal types. Three quick-connect types are
offset to meet international 3mm spacing
requirements and one is designed for use
with molded connectors. Contact material choice includes gold alloy, silver alloy
or silver for handling various electrical
loads. There are two mounting hole sizes
available. Standard .114N or 3mm to meet
European design requirements.
dard receptacles and connectors. The
plastic enclosure meets VDE KC250 arc
tracking requirement and is approvable
under the Refrigeration Industry Taste
and Odor test.
OPERATING FORCES
175 grams (V rating only)
150 grams (Not applicable to Electrical
Rating V)
75 grams (Not applicable to Electrical
Rating C or V)
50 grams (Not applicable to Electrical
Rating B, C, V)
25 grams (Not applicable to Electrical
Rating B, C, E, V)
15 grams (Not applicable to Electrical Rating A, B, C, E, S, V)
Mounting Torque:
2 inch pounds min.
5 inch pounds max.
Terminal variations and switch dimensions of the European designed version
conform to applicable DIN standards.
These V7s mate with both standard domestic and international industry stan-
ELECTRICAL RATINGS
A
5 amps, 125,
250 or 277
VAC; 1⁄10 hp,
250 VAC
W
15.1 amps,
125, 250 or 277
VAC
B
11 amps and 1⁄3
hp, 125, 250 or
277 VAC; 1⁄2
amp, 125 VDC;
1
⁄4 amp, 250
VDC; 4 amps,
125 VAC ‘‘L’’
C*
15.1 amps and
1
⁄2 hp, 125, 250
or 277 VAC; 1⁄2
amp, 125 VDC;
1
⁄4 amp, 250
VDC; 5 amps,
120 VAC ‘‘L’’
D
1 amp, 125
VAC
E
10 amps and 1⁄3
hp 125 or 250
VAC; 1⁄2 amp,
125 VDC; 1⁄4
amp, 250 VDC;
4 amps, 125
VAC ‘‘L’’
F
3 amps, 125,
250 or 277
VAC; 1⁄10 hp,
250 VAC
S
V
.1 amp,
125 VAC
21 amps 125,
250 or 277
VAC, 1 HP 125,
250, 277 VAC;
2 HP, 250, 277
VAC
+++
16 (4)
250V `
µ
T 85
50E3 SPNO only
X
6 amps; 1⁄8 HP
125, 250 or 277
VAC
International Series Only
10 (3) +++
250V `
µ
T 85
5 (2) +++
250V `
µ
T 85
* Available only when specifying 150 gram operating force.
NOTE: ‘‘L’’ denotes lamp load.
**The microgap construction (M) means contact gap is less than 3mm. Therefore, these products are suitable for secondary circuit use but not
primary circuit use which requires a 3mm gap.
38
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Miniature
V7 Series
AVAILABLE TERMINALS
Quick-connect
D8*
.187 Wide H
.020 Thick
NOTE: D8 and E8 terminals are European approved when used with electrical ratings B, D,
or E. E9 terminals are European approved
when used with electrical ratings B, C, D, or E.
Printed Wiring Board
E8
.187 Wide H
.020 Thick
E9
.250 Wide H
.032 Thick
* International approving agencies will require that
switches with these terminals have insulated receptacles or connector.
PO1
Miniature/
Subminiature
Printed wiring board terminals interface
with snap-on receptacles and other components from AMPMODU interconnection system.
Dimensions shown are for reference
only.
PO2
PO7
This section covers only 48 of our most popular V7 Series catalog listings. If you don’t find what you’re looking for, it’s likely
one of the approximately 300 other active V7 listings will meet your needs. Contact the 800 number.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
39
Basic Switches
Miniature
V7 Series
TIMERSAVER SERIES
PIN PLUNGERS
ORDER GUIDE - SPDT*
Elect.
Rating
P. 38
O.F. max.
grams
ounces
R.F. min.
grams
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T.
mm
inches
V7-1S17D8
1 Amp
S
150
5.3
25
.88
1,19
.047
1,27
.050
0,05-0,25
.002-.010
V7-3S17E9
1 Amp
S
50
1.75
5
.175
1,19
.047
1,27
.050
0,05-0,25
.002-.010
V7-3A17E9
5 Amps
A
50
1.75
5
.175
1,19
.047
1,27
.050
0,05-0,25
.002-.010
V7-2B17D8
11 Amps
B
75
2.63
10
.35
1,19
.047
1,27
.050
0,05-0,25
.002-.010
V7-2B17E9
11 Amps
B
75
2.63
10
.35
1,19
.047
1,27
.050
0,05-0,25
.002-.010
V7-1C17D8
15.1 Amps
C
150
5.3
25
.88
1,19
.047
1,27
.050
0,05-0,25
.002-.010
V7-9W1AE9
15.1 Amps
W (350°F)
300
10.6
25
.88
1,19
.047
1,27
.050
0,25
.010 max.
V7-1V19E9
21 Amps
V
175
6.1
20
.70
1,19
.047
1,27
.050
0,05-0,25
.002-.010
Catalog
Listing
Dim. Dwg. Fig. 1
Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. –
Pretravel; O.T. – Overtravel; D.T. – Differential Travel.
STRAIGHT LEVERS
ORDER GUIDE - SPDT* .87N LEVER TIMESAVER SERIES
Dim. Dwg. Fig. 2
V7-3S17D8-002
1 Amp
S
54
1.9
3
.11
1,52
.060
0,89
.035
0,33
.013
V7-1A17D8-002
5 Amps
A
160
5.6
7
.25
1,52
.060
0.89
.035
0,38
.015
V7-2B17D8-002
11 Amps
B
80
2.8
5
1.76
1,52
.060
0,89
.035
0,38
.015
V7-1C17E9-002
15.1 Amps
C
160
5.6
17
.60
1,52
.060
0,89
.35
0,36
.014
V7-1V19E9-002
21 Amps
V
185
6.5
13
.5
1,65
.065
0,89
.035
0,38
.015
1.40N LEVER TIMESAVER SERIES
Dim. Dwg. Fig. 5
V7-3S17D8-022
1 Amp
S
30
1.05
1
0.035
3,04
.120
2,16
.085
0,76
.030
V7-1A17E9-022
5 Amps
A
85
3
8
.28
3,04
.120
1,52
.060
0,76
.030
V7-1X2AD8-022
6 Amps
X (350°F)
185
6.5
15
.53
1,40
.055
0,76
.030
0,38
.015
V7-1B17D8-022
11 Amps
B
82
2.9
8
.28
3,04
.120
1,7
.067
0,68
.027
V7-1C17E9-022
15.1 Amps
C
82
2.9
8
.28
3,04
.120
1,7
.067
0,76
.030
V7-1V19E9-022
21 Amps
V
95
3.3
5
.18
3,3
.130
1,78
.070
0,76
.030
2.34N LEVER TIMESAVER SERIES
V7-3S17D8-048
1 Amp
S
16
.56
.5
.018
5,97
.235
3,0
.118
1,27
.050
V7-2B17D8-048
11 Amps
B
20
.7
1
.035
5,97
.235
2.92
.115
1,27
.050
V7-1C17E9-048
15.1 Amps
C
85
3
4
.14
5,97
.235
1,65
.065
1,29
.051
V7-9W1AE9-048
15.1 Amps
W (350°F)
90
3.2
4
.14
6,35
.250
3,15
.124
1,37
.054
* For SPST (N.O. & N.C.) circuitry, contact the 800 number.
NOTE: Catalog listings in V7 Order Guides have standard .114N mounting holes. For 3mm size holes, contact the 800
number.
40
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Miniature
SIMULATED
ROLLER LEVERS
V7 Series
Characteristics: O.F. – Operating Force; R.F. –
Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T.
– Differential Travel.
ORDER GUIDE - SPDT*
1.29N LEVER TIMESAVER SERIES
Catalog
Listing
Elect.
Rating
P. 38
O.F. max.
grams
ounces
R.F. min.
grams
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T. max.
mm
inches
1.29N LEVER TIMESAVER SERIES
V7-1S17D8-263
1 Amp
S
90
3.15
9
.32
2,79
.110
1,9
.075
0,76
.030
V7-1B17D8-263
11 Amps
B
90
3.15
9
.32
2,79
.110
1,52
.060
0,76
.030
V7-1C17D8-263
15.1 Amps
C
91
3.19
9
.32
2,79
.110
1,54
.061
0,61
.024
Dim. Dwg. Fig. 3
.81N ROLLER LEVER TIMERSAVER SERIES
Dim. Dwg. Fig. 4
1 Amp
S
90
3.15
7
.25
1,19
.047
1,02
.040
0,38
.015
V7-2B17D8-201
11 Amps
B
88
3.1
7
.25
1,3
.052
1,04
.041
0,3
.012
V7-1C17E9-201
15.1 Amps
C
176
6.16
19
.67
1,3
.052
0,81
.032
0,3
.012
V7-1V19E9-201
21 Amps
V
205
7.2
15
.5
1,42
.056
0,81
.032
0,33
.013
1.34N ROLLER LEVER TIMESAVER SERIES
Dim. Dwg. Fig. 7
V7-3S17D8-207
1 Amp
S
35
1.23
2
.07
2,79
.110
2,03
.080
0,76
.030
V7-2A17D8-207
5 Amps
A
43
1.51
3
.105
2,92
.115
1,52
.060
0,64
.025
V7-1C17E9-207
15.1 Amps
C
86
3
9
.32
2,84
.112
1,63
.064
0,64
.025
V7-1V19E9-207
21 Amps
V
100
3.5
7
.25
3,07
.121
1,65
.065
0,76
.030
* For SPST (N.O. & N.C.) circuitry, contact the 800 number.
NOTE: Catalog listing in V7 Order Guides have standard .114N mounting holes. For 3mm size holes, contact the 800 number.
ORDER GUIDE – ACCESSORIES
Catalog Listing
Description
15PA176-V7
Connector/Receptacle packet - Includes 25
connectors and 75 receptacles with 18 N, blue 16
gauge PVC insulated, stranded wire. (To be used
with D8 terminals only).
15PA260
Plunger boot seal. Elastomer dust and splash
resistant plunger seal.
Catalog Listing
15PA177-V7
Description
Insulator packet (500 pcs.) .018N thick
varnished fiberglass.
Dimensions shown are for reference only.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
41
Miniature/
Subminiature
V7-2S17D8-201
Basic Switches
Miniature
V7 Series
INTERNATIONAL SERIES
PIN PLUNGER
Elect.
Rating
P. 38
O.F. max.
grams
ounces
R.F. min.
grams
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T.
mm
inches
V7-1B11E9
11 Amps
B
150
5.3
25
.88
1,19
.047
1,27
.050
0,05-0,25
.002-.010
V7-2B11D8
11 Amps
B
75
2.63
10
.35
1,19
.047
1,27
.050
0,05-0,25
.002-.010
V7-2B11PO2
11 Amps
B
75
2.63
10
.35
1,19
.047
1,27
.050
0,05-0,25
.002-.010
V7-3E11D8
10 Amps
E
50
1.75
5
.175
1,19
.047
1,27
.050
0,05-0,25
.002-.010
V7-3E11E9
10 Amps
E
50
1.75
5
.175
1,19
.047
1,27
.050
0,05-0,25
.002-.010
Catalog
Listing
Dim. Dwg. Fig. 1
STRAIGHT LEVERS
Dim. Dwg. Fig. 5
SIMULATED
ROLLER LEVERS
Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel.
ORDER GUIDE - SPDT*
INTERNATIONAL SERIES
1.40 N LEVER INTERNATIONAL SERIES
V7-1B11E9-022
11 Amps
B
80
2.8
8
.28
2,79
.110
2,28
.090
0,76
.030
V7-2B11E9-022
11 Amps
B
45
1.58
4
.14
2,79
.110
2,28
.090
0,76
.030
V7-3E11D8-022
10 Amps
E
30
1.05
2
.070
2,79
.110
2,28
.090
0,76
.030
1.29N LEVER INTERNATIONAL SERIES
V7-2B11D8-263
11 Amps
B
50
1.75
5
.175
2,54
.100
1,9
.075
0,76
.030
V7-3E11E9-263
10 Amps
E
33
1.16
2
.070
2,54
.100
1,9
.075
0,76
.030
Dim. Dwg. Fig. 3
ROLLER LEVERS
ORDER GUIDE - SPDT* .81N LEVER INTERNATIONAL SERIES
V7-2B11D8-201
11 Amps
B
90
3.15
10
.35
1,19
.047
1,02
.040
0,38
.015
V7-3E11D8-201
10 Amps
E
62
2.17
5
.175
1,19
.047
1,02
.040
0,38
.015
5
.175
2,54
.100
2,16
.085
0,76
.030
Dim. Dwg. Fig. 4
1.34N LEVER INTERNATIONAL SERIES
V7-2B11E9-207
11 Amps
B
45
1.58
NOTE: Catalog listings in V7 Order Guides have standard .114N mounting holes. For 3mm size holes, contact the 800
number.
Dim. Dwg. Fig. 7
42
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Miniature
V7 Series
MOUNTING DIMENSIONS (for reference only)
PIN PLUNGER
Fig. 1
Miniature/
Subminiature
Fig. 2
Straight Lever
(Style-002)
Fig. 3
Simulated Roller
(Style-263)
Fig. 4
Roller Lever
(Style-201)
Fig. 5
Straight Lever
(Style-022)
Fig. 6
Straight Lever
(Style-048)
Fig. 7
Roller Lever
(Style-207)
NOTE: All levers are 0.17N (4,31 mm) wide. Rollers are 0.19N (4,82 mm) wide.
NOTE:
Operate point dimensions taken at top of lever/roller.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
43
BASIC SWITCHES
ZM, ZX, ZV and ZW Series Subminiatur e
Basic Switche s
zx
App
Straight /ever
9 .8
0.78
Ele l
ZM, ZX, ZV and ZW Series Subminiature Basic Switches are cost effective devices used for simple on/off applications . These switche s
combine small size and light weight with ample electrical capability an d
long life . Plastic lever capability is available on the ZV Series .
Electrical rating :
Voltage :
Operating temperature :
Termination :
Contact type :
Switching options :
01
i
0 .1 A, 3 A, 5 A or 10 .1 A
125/250 Va c
25 °C to 85 °C [-13 °F to 185 °F ]
Quick connect, solder, PC B
Gold or silve r
SPDT
T1
ll'
~w1
`rJ
8.8
0 .346
ZM Series
Approvals :
Electrical rating :
5.1
0 200
I
7 .3
0.287
9S
0.374
0 .6
0.02 4
5.2
I 0.205
UL/CS A
0 .1 A, 5 A or 10.1 A
TERMINATION
Quick connect
Solder
OPTIONS
Top pin plunge r
ELECTRICAL RATIN G
5A
5A
CONTACT TYPE
silver
silver
REFERENCE
ZM50E70DO 1
ZM50E10DO1
Simulated roller lever
Wlis n
19 .8
0.78
3.2
3.9
0 .154
D_126
12 .7
0.50 0
+0.1
m70 .4-0 ~
+0 .004
00,0940
m2. 5
0009
. 8
0
1 .6
0 .0633
8.8
0 .346
5.1
0 .200
S
7. 3
0.25 7
9 .5
0.374
_
5 .2
0 .205
55-53
TERMINATION
Quick connect
Solder
PCB
Solder
ELECTRICAL RATING
5A
5A
10.1 A
0.1 A
CONTACT TYPE
silver
silver
silver
gold
REFERENC E
ZM50E70AO 1
ZM50E1OA0 1
ZM90G2OAO 1
ZM10BI0A01
0. 6
0 02 4
0 .346
5 .1
0 .200
TERMINATION
Quick connec t
Solder
Honeywell
www.honeywell .com/sensin g
9 .5
0 .374
0205 '
ELECTRICAL RATING
5A
5A
CONTACT TYPE
silver
silver
REFERENC E
ZM50E70EO1
ZM50E10EO1
I
BASIC SWITCHES
IW
ZX Serie s
Simulated roller leve r
Approvals :
Electrical rating :
U L/C S A
0 .1 A or 3 A
n
L
I
OPTIONS
1I
Top pin plunger
57
0 .2 24
2 .9
0 .114--
01
to
2 .7
0 .5
5.2
0 .205
11 2
0 .044
P
57
1
1—
.05
'0 .081
_92
''6
-121 J0
e
0
J -I - -
0 .1
6 .5
0 .435
I- -. -5 .08
_L
02
--
6 .5
0.256
3 .1 5
0 .124
5.08
5 .08
0.2
0 .2
0.4
001 6
- .-- _ 12 8
0 .506
TERMINATION
PCB
Solder
I
3 .1 5
1
0 .4
+~ -001 6
112
424-1- 0 .049
5 .08
02
5 .8
0228
ELECTRICAL RATING
3A
3A
CONTACT TYP E
silve r
silver
REFERENC E
ZX40E30EO 1
ZX40E10E0 1
0.04 9
5 .8
0.228
12 .8
0.504
ZV Series
TERMINATION
PCB
Solder
ELECTRICAL RATING
3A
0.1 A
CONTACT TYPE
silve r
gold
REFERENCE
ZX40E30AO1
ZX10C10AO1
Approvals :
Electrical rating :
UL/ENE C
0 .1 A, 5 A or 10 .1 A
OPTIONS
Straight lever
Top pin plunge r
2 .7
0 .5
57
0 .22 4
19 .8
0.78
2.9
0 .114
2.2 5
0 .08 9
4.85
D.191
I
12. 7
0.50 0
al
g
)
Pt:
dra
02 .4- 0
o oo'
00098
1. 6
0.063
0.4
0 .01 6
TERMINATIO N
PCB
Solder
ELECTRICAL RATING
3A
3A
8.8
0.374
.1
0 .200
0 .04 9
5.8
0 .22 8
0.504
CONTACT TYPE
silve r
silver
REFERENCE
ZX40E30001
ZX40E10001
TERMINATIO N
PC B
Solde r
Quick connect
hr,r, A\r\A/r.11 es"
MS /0, ',I,
.0940
7.3
0.287
9.5
0.374
ELECTRICAL RATING
5A
5A
0 .1 A
Honeywel l
IAn An AI
00I
0.6
0 .02 4
5 .2
0.205
CONTACT TYPE
silver
s3vvr
gold
REFERENC E
ZV50E20A01
ZV50E10A0 1
ZVI OB70AO 1
IA
:
BASIC SWITCHES
S
ZW Sealed Series
Straight lever
Approvals :
Electrical rating :
19 .8
0.78
2.2 5
4.85
0 .08 9
0 .191
~
OPTIONS
L-
Ir~
Top pin plunge r
-
.
S~
A
~~
1.6
88
5 .1
0.200
0 .29 5
L
7. 3
0.374
0 .063
0 .191
I +0. 1 ! 0, 2 .4-,O
' 00.0941'0
02' 5
00.098
TERMINATION
Solder
Quick connect
S
12 .7
0 .500
17 . 4
ft
UL/ENE C
0 .1 Aor5A
Ri
0.28 7
9 .5
I
0 .374
ELECTRICAL RATING
5A
5A
52
0.205
CONTACT TYPE
silver
silver
2Io
TE
W
REFERENC E
ZV50E10B0 1
ZV50E7000 1
7.5
0.295
7 .5
0 .295
9 .5
0 .3/ 4
19. 8
0.780
5 2
5.205
Roller lever
TERMINATION
Solder
6. 4
0.252
3.55
4
2 .4C
094
ELECTRICAL RATING
5A
CONTACT TYPE
silve r
REFERENC E
ZW50F15AD1
(C
0.140
Straight lever
I
II
90, 3
0.01 2
3z
I .2
0.04 7
0.126
TERMINATIO N
PCB
Quick connect
ELECTRICAL RATING
5A
5A
CONTACT TYPE
silver
silver
REFERENC E
ZV50E20FO1
ZV50E70FO1
520
0 .205
9.5
C
0 .37 4
19 .8
0.780
TERMINATION
Solder
Honeywel l
www.honeywell .com/sensin g
ELECTRICAL RATING
0.1 A
CONTACT TYPE
gold
REFERENC E
ZW1OE15CD1
•
•
Roller leve r
CON : BLACK NO,CYAN
Y
1
0}
OS
a
°
0.11830 .020 °
I
TERMINATION
Wire leads
I
NC_ 0R A Y
5.2
9 .5
0.205 0.37 4
19. 8
0 .780
ELECTRICAL RATING CONTACT TYPE
0.1 A
gold
J J
001.0.B 1
6 .4
0.252
REFERENCE
ZW10E90FW 1
S
(t
(5
Honeywel l
www.honeywell .com/sensing
m
Basic Switches
Miniature Double-break
TB Series
FEATURES
1 Power load switching capability up to
10 amperes
1 Motor handling capacity of 1⁄2 horsepower, 125 VAC
1 Two- and four-circuit double-break
1 Several auxiliary actuators
1 Choice of terminal styles
1 UL recognized, CSA certified
1 Momentary action
Description
The terminals of two- and four-circuit double break switches must be wired to identical voltage sources and the same polarity so that a voltage potential is not set up
between adjacent terminals. A voltage
potential between adjacent terminals
could promote dielectric breakdown at
high energy levels. The loads should be
on the same sides of the line.
Characteristics: O.F. – Operating Force; R.F. – Release Force;
P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P.
– Operating Position.
ORDER GUIDE
Catalog
Listing
GENERAL INFORMATION
TB miniature switches are basic doublebreak units which offer a means of controlling isolated circuits. Each circuit can
be driven by independent voltage sources. These switches find many uses in
modern control systems because of their
circuitry.
Electrical
Data And
UL Code
Page 20
O.F.
newtons
ounces
R.F. min.
newtons
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T.
mm
inches
O.P.**
mm
inches
1TB1-1
Two-circuit, doublebreak end screw
terminals
10 Amps
Z
1,95-3,61
7-13
1,11
4
1,52
.060
0,25
.010
0,25-0,64
.010-.025
11,7
.460
1TB1-2
Two-circuit, doublebreak end solder
terminals
10 Amps
Z
1,95-3,61
7-13
1,11
4
1,52
.060
0,25
.010
0,25-0,64
.010-.025
11,7
.460
1TB1-3
Two-circuit, doublebreak front solder
terminals
10 Amps
Z
1,95-3,61
7-13
1,11
4
1,52
.060
0,25
.010
0,25-0,64
.010-0.25
11,7
.460
41TB5-3
Four-circuit, doublebreak front solder
terminals
10 Amps
Z
5,56-10,0
20-36
2,22
8
1,78
.070
0,25
.010
0,64-1,14
.025-.045
4,70
.185
Dim. Dwg. Fig. 1
Dim. Dwg. Fig. 2
Dim. Dwg. Fig. 3
* ±0,38 mm
±.015 in
Dim. Dwg. Fig. 4
44
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Miniature Double-break
TB Series
AUXILIARY ACTUATORS
For use with 1TB1-1 and 1TB1-2 switches
ORDER GUIDE
Catalog Listing
JT-1
Description
JT-1
Leaf actuator
JT-5
Roller leaf actuator
JT-5
Switches are not included with the actuators.
Miniature/
Subminiature
MOUNTING DIMENSIONS (For reference only)
Fig. 1
Fig. 2
Fig. 3
Fig. 4
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
45
Basic Switches
Standard
BZ/BA Series
STANDARD BASIC SWITCH CUT-A-WAY
The cut-a-way shown is representative of the standard basic switches described in this
catalog.
GENERAL INFORMATION
MICRO SWITCH standard basic switches
are precision snap-action mechanisms
enclosed in accurately molded plastic
cases. These switches are carefully manufactured and thoroughly inspected.
They are industry known for their compactness, light weight, accurate repeatability and long life.
Mounting holes for Types BZ, BM, BA, BE,
DT, MT, and 6AS switches accept pins or
screws of .139 inch (3,53 mm) diameter.
Characteristics as stated are taken at normal room temperature and humidity.
These may vary as temperature and humidity conditions differ.
GENERAL SWITCH IDENTIFICATION
Standard
Basic Switches
MOUNTING DIMENSIONS
Mounting dimensions are included at the
end of each product section. They are
shown in English and metric equivalents.
These dimensions are for reference only.
For exacting layout work, request an engineering layout work, request an engineering drawing from the 800 number.
The type BZ switch design meets most
applications needs. Modifications of the
standard silver contact design and material, spring configuration, and plunger locations give the type BM, BA and BE
switches greater electrical load handling
capacity. Other changes in materials and
switch design provide operating characteristics, temperature tolerances, and
sealing to cover a wide range of special
requirements.
FEATURES
1 Operating force as low as 4 oz. (113
grams) maximum
1 Sensitive differential travel as low as
.0002 to .0003 inches (0,005 to 0,008
mm)
1 Power load switching capability to 25
amperes
1 Motor handling capacity to 2 horsepower at 250 VAC
1 Long mechanical life
1 High temperature constructions for up
to +400°F (204°C)
1 Momentary or maintained contact
action
1 Alloy contacts available for special application needs
1 Variety of integral actuators
1 Variety of auxiliary actuators
1 Variety of terminal designs
1 Optional sealed plunger and cover
1 Stainless steel snap spring available
1 Military standard construction available with over 50 listings on the MILS-8805 Qualified products list
1 UL recognized, CSA certified
First letter in catalog listing designates:
B = Single-pole double-throw
W = Single-pole single-throw (normally closed)
Y = Single-pole single-throw (normally open)
Second letter in catalog listing designates:
Z = Standard 15-amp version
M = 22-amp version
A = Standard 20-amp version
E = 25-amp version
RECOMMENDED TORQUE (max.)
Mounting screws . . . . . . . . . . . . 3 in./lbs.*
Terminal screws . . . . . . . . . . . . . . 4 in./lbs.
Panel mount bushing . . . . . . . 4-6 in./lbs.
*Note: Tightening mounting screws
above 3 in./lbs. changes operating characteristics and increases
the possibility of cracking the
case.
This section covers only over 100 of our most popular BZ/BA type Series
catalog listings. If you don’t find what you’re looking for, it’s likely one of
the approximately 1800 other active listings will meet your needs. Contact the 800 number.
UL/CSA
Our basic switches are Component Recognized by Underwriters’ Laboratories, Inc. and certified by Canadian Standards Association. The BA, BZ, and BM line is covered as Special Use Switches to UL Standard 1054; the BE line is covered as an Industrial Motor
Controller to UL Standard 508.
Agency File References
are:
BA
BM
BZ
BE-1,2,5
BE-R
For application help: call 1-800-537-6945.
UL File E12252, issued 12-09-88
UL File E12252, issued 12-08-88
UL File E12252, issued 6-29-89
UL File E22779, Vol. 4, Sec. 1
UL File E22779, Vol. 4, Sec. 2
Honeywell Sensing and Control
47
Basic Switches
Standard
BZ/BA Series
AVAILABLE TERMINALS
Most of the BZ/BA catalog listings have
A2 type terminals. Several other terminal
styles are shown and others are available.
Specific information should be requested
from the 800 number or local Authorized
Distributor.
Solder (No suffix)
Use up to #14 wire
A2
Bottom facing 6-32 NC × .218N
screw with cup washers
A4
(Same as A2 except #8 screws)
D6
.250N (6,35 mm) wide × .032N (0,81 mm) thick
quick-connect
D5
.250N (6,35 mm) wide × .030N (7,62) thick
quick-connect
T
Bottom facing 6-32 NC × .218N screw
with Sems lockwashers
P4
Side facing 8-32 × .218N screw with cup washers
PC2
Self lifting pressure plate terminals and plastic
barriers for added dielectric protection
ACTUATORS
BA, BE, BM and BZ standard basic
switches use the actuators described.
48
Pin plunger; in-line motion
Overtravel plunger; in-line
applications requiring additional
overtravel
Roller lever; Very low force, fast
moving cams
Roller leaf; Low-force, large
movement actuation
Honeywell Sensing and Control
Added overtravel in a panel mount
roller plunger; Actuation by cams
Leaf; Low-force, slow moving cams or
slides
Lever; Very low force, slow cams and
slides
Added overtravel in a panel-mount
plunger; Heavy-duty in-line
applications or slow cams.
Cam rise should not exceed 30°
For application help: call 1-800-537-6945.
Basic Switches
Standard
BZ/BA Series
Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T.
— Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. —
Operating Position.
ORDER GUIDE by ascending electrical capability
PIN PLUNGER
Catalog
Listing
BZ/BA TYPE
Dim. Dwg. Fig. 1
Electrical
Data And
O.F.
R.F. min. P.T. max. O.T. min.
UL Codes newtons newtons
mm
mm
Recommended For Page 46
ounces ounces inches
inches
Applications requiring
gold alloy contacts
1 Amp
P
2,5-3,61
9-13
1,11
4
0,38
.015
0,13
.005
0,01-0,05
.0004-.0020
15,88
.625
BZ-2R725551-A2
Gold alloy contacts
Dustproof and splash
resistant seal
1 Amp
P
2,22-4,17
8-15
1,11
4
—
—
0,13
.005
0,01-0,06
.0004-.0025
15,88
.625
BZ-2R244-A2
Operating in temp. to
+400°F (204°C) for
100 hours
5 Amps
B
2,5-3,61
9-13
1,11
4
0,38
.015
0,13
.005
0,01-0,05
.0004-.0020
15,88
.625
BZ-R21-A2
Lower force
10 Amps
C
1,11
4
0,7
2.5
0,30
.012
0,13
.005
0,005-0,013
.0002-.0005
15,88
.625
BZ-2R-A2
Most applications
SPDT
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
0,13
.005
0,01-0,05
.0004-.0020
15,88
.625
WZ-2R-A2
SPST (normally
closed)
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
0,13
.005
0,01-0,05
.0004-.0020
15,88
.625
YZ-2R-A2
SPST (normally open)
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
0,13
.005
0,01-0,05
.0004-.0020
15,88
.625
BZ-R-A2
Less differential travel
15 Amps
D
1,95-2,5
7-9
1,11
4
0,30
.012
0,13
.005
0,005-0,008
.0002-.0003
15,88
.625
BZ-R19-A2
Best repeatability
15 Amps
D
1,95-3,34
7-12
1,11
4
0,30
.012
0,13-0,2
0,005-0,02
.005-.008 .0002-.0008
16,26
.640
BZ-2R24-A2
Operating in temp. to
+250°F (121°C)
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
0,13
.005
0,01-0,05
.0004-.0020
15,88
.625
BZ-2RT04
(8805/1-004)
MIL-S-8805 application
requirements
15 Amps
A
2,5-3,61
9-13
1,67
6
0,38
.015
0,13
.005
0,01-0,05
.0004-.0020
15,88
.625
BZ-2R05-A2
Best stability under
varying humidity
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
0,13
.005
0,01-0,05
.0004-.0020
15,88
.625
BZ-2R5551-A2
Dustproof and splash
resistant seal
15 Amp
A
2,5-4,17
9-15
1,11
4
—
—
0,13
.005
0,01-0,06
.0004-.0025
15,88
.625
BZ-2R55-A2-S
Best service for sealed
construction. Stainless
steel internal snap
spring.
15 Amps
A
2,5-4,17
9-15
1,11
4
—
—
0,13
.005
0,01-0,06
.0004-.0025
15,88
.625
BA-2R-A2
Up to 20 ampere load
handling
20 Amps
G
3,89-6,12
14-22
2,78
10
1,27
.050
0,25
.010
0,05-0,19
.0020-.0075
16,26
.640
BA-2R24-A2
Operating in
temperature to +250°F
(121°C)
20 Amps
G
3,89-6,12
14-22
2,78
10
1,27
.050
0,25
.010
0,05-0,19
.0020-.0075
16,26
.640
BM-1R-A2
Up to 22 ampere load
handling
22 Amps
F
1,95-2,78
7-10
1,11
4
0,38
.015
0,13
.005
0,013-0,025
.0005-.0010
15,88
.625
BE-2R-A4
Up to 25 ampere load
handling
25 Amps
H
3,89-6,12
14-22
2,78
10
1,27
.050
0,25
.010
0,05-0,19
.0020-.0075
16,26
.640
BZ-RX
Manual reset
(maintained contact)
applications, solder
terminals
15 Amps
E
1,95-2,5
7-9
0,56-2,78*
2-10
—
—
—
—
0,30
.012
—
—
0,13
.005
0,38*
.015
—
—
15,88
.625
WA-1RX-A4
Manual reset SPSTNC, A4 terminals
20 Amps
W
5,56
20
6,95*
25
—
—
—
—
—
—
—
—
0,25
.010
—
—
0,20
.008
—
—
16,26
.64
27,9*
1.10
Dim. Dwg. Fig. 3
Dim. Dwg. Fig. 4
Except where stated ** ±0,38mm
±.015 in.
*Reset characteristics.
All catalog listings shown are not
necessarily stock items. Stocking
depends on sales experience.
For application help: call 1-800-537-6945.
Auxiliary actuators see p. 62-63.
Honeywell Sensing and Control
49
Standard
Basic Switches
BA/BE TYPE
O.P.**
mm
inches
BZ-2R72-A2
SEALED TYPE
Dim. Dwg. Fig. 2
D.T.
mm
inches
Basic Switches
Standard
BZ/BA Series
Characteristics: O.F. — Operating Force;
R.F. — Release Force; P.T. — Pretravel;
O.T. — Overtravel; D.T. — Differential Travel;
O.P. — Operating Position.
OVERTRAVEL
PLUNGER
ORDER GUIDE
Catalog Listing
Recommended For
Electrical
Data and
UL Codes
Page 46
O.F.
newtons
ounces
R.F. min.
newtons
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T.
mm
inches
O.P.*
mm
inches
BZ-2RD72-A2
Applications requiring gold
alloy contacts
1 Amp
P
2,5-3,61
9-13
1,11
4
0,38
.015
1,52
.060
0,01-0,05
.0004.0020
21,21
.835
BZ-2RD-A2
Added overtravel. For
manual operation and slow
20° (max) cam rise
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
1,52
.060
0,01-0,05
.0004.0020
21,21
.835
BZ-2RD24-A2
Operating in temperature
to +250°F (121°C)
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
1,52
.060
0,01-0,05
.0004.0020
21,21
.835
BM-1RD-A2
Up to 22 ampere load
handling
22 Amps
F
1,95-2,78
7-10
1,11
4
0,38
.015
1,52
.060
0,013-0,025
.0005.0010
21,21
.835
BZ-2RDS725551-A2
Applications requiring gold
alloy contacts plus
dustproof and splash
resistant seal
1 Amp
P
3,61-5,28
13-19
1,11
4
—
1,52
.060
0,01-0,063
.0004.0025
28,20
1.110
Dustproof and splash
resistant seal
15 Amps
A
3,61-5,28
13-19
1,11
4
—
1,52
.060
0,01-0,063
.0004.0025
28,20
1.110
BA-2RB-A2
Up to 20 ampere load
handling
20 Amps
G
3,89-6,12
14-22
2,78
10
1,27
.050
2,39
.094
0,05-0,19
.0020.0075
26,20
1.03
BE-2RB-A4
Up to 25 ampere load
handling
25 Amps
H
3,89-6,12
14-22
2,78
10
1,27
.050
2,39
.094
0,05-0,19
.0020.0075
26,20
1.03
BZ-2RS72-A2
Applications requiring gold
alloy contacts
1 Amp
P
2,5-3,61
9-13
1,11
4
0,38
.015
1,52
.060
0,01-0,05
.0004.0020
28,20
1.110
BZ-2RS-A2
Added overtravel. For
in-line operation and with JR
auxiliary actuators
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
1,52
.060
0,01-0,063
.0004.0025
28,20
1.110
BZ-2RS24-A2
Operating in temperature
to +250°F (121°C)
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
1,52
.060
0,01-0,05
.0004.0020
28,20
1.110
MIL-S-8805 application
requirements
15 Amps
A
2,5-3,61
9-13
1,67
6
0,38
.015
1,52
.060
0,01-0,05
.0004.0020
28,20
1.110
BZ-RSX
Manual reset
solder terminals
15 Amps
E
1,95-2,64
7-9
—
—
0,30
.012
0,64
.025
—
—
2,79
1.11
BM-1RS-A2
Up to 22 ampere load
handling
22 Amps
F
1,95-2,78
7-10
1,11
4
0,38
.015
1,52
.060
0,013-0,025
.0005.0010
28,20
1.110
BZ-2RS7225551-A2
Applications requiring gold
alloy contacts plus
dustproof and splash
resistant seal
1 Amp
P
2,5-4,17
9-15
1,11
4
—
1,52
.060
0,01-0,063
.0004.0025
28,20
1.110
15 Amps
A
2,5-4,17
9-15
1,11
4
—
1,52
.060
0,01-0,063
.0004.0025
28,20
1.110
Dim. Dwg. Fig. 11
BZ-2RDS5551-A2
Dim. Dwg. Fig. 12
Dim. Dwg. Fig. 13
BZ-2RST04
(M8805/1-012)
Dim. Dwg. Fig. 14
BZ-2RS5551-A2
Dustproof and splash
resistant seal
*±0,51 mm
±.020 in.
Dim. Dwg. Fig. 15
50
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Standard
OVERTRAVEL
PLUNGER
BZ/BA Series
ORDER GUIDE
Catalog Listing
Recommended For
Electrical
Data and
UL Codes
Page 46
O.F.
newtons
ounces
R.F. min.
newtons
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T.
mm
inches
O.P.**
mm
inches
BZ-2RQ-A2
Added overtravel. For
manual in-line operation and
for slow 30° (max) rise cams
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
5,56
.219
0,01-0,05
.0004.0020
38,10±0,51
1.500±.020
BZ-2RQ24-A2
Operating in temperature
to ±250°F (121°C)
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
5,56
.219
0,01-0,05
.0004.0020
38,10±0,51
1.500±.020
BZ-2RQ172-A2
Applications requiring gold
alloy contacts
1 Amp
P
2,5-3,61
9-13
1,11
4
0,38
.015
5,56
.219
0,01-0,05
.0004.0020
21,82
.859
BZ-2RQ1-A2
BZ-2RQ-A2 type applications
with panel mount
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
5,56
.219
0,01-0,05
.0004.0020
21,82
.859
MIL-S-8805 application
requirements
15 Amps
A
2,5-3,61
9-13
1,67
6
0,38
.015
5,56
.219
0,01-0,05
.0004.0020
21,82
.859
BZ-2RQ124-A2
Operating in temperature
to ±250°F (121°C)
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
5,56
.219
0,01-0,05
.0004.0020
21,82
.859
BZ-2RN702
Furnished with
unassembled seal
boot.
15 Amps
X
2,5-3,61
9-13
1,11
4
0,38
0.15
3,18
.125
0,01-0,05
.0004.0020
48,4±0,50
1.906±.020
BZ-RQ1X
Manual reset.
Solder terminals
15 Amps
E
1,67-2,64
6-9.5
–
–
0,30
0.12
5,56
.219
–
–
23,42±1,14
.922±.045
7,14*
.281*
BA-2RQ1-A2
Up to 20 ampere load
handling
20 Amps
G
3,89-6,12
14-22
2,78
10
1,27
.050
5,56
.219
0,05-0,19
.0020.0075
21,82
.859
BM-1RQ1-A2
Up to 22 ampere load
handling
22 Amps
F
1,95-2,78
7-10
1,11
4
0,38
.015
5,56
.219
0,0130,025
.0005.0010
21,82
.859
BZ-2RQ1872-A2
Applications requiring gold
alloy contacts
1 Amp
P
2,5-3,61
9-13
1,11
4
0,38
.015
3,56
.140
0,01-0,05
.0004.0020
33,32±1,14
1.312±.045
BZ-2RQ18-A2
Added overtravel. Roller
plunger for rapid cam (30°
max) rise and slide
operation. Panel mount
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
3,56
.140
0,01-0,05
.0004.0020
33,32±1,14
1.312±.045
BZ-2RQ1824-A2
Operating in temperature
to ±250°F) (121°C)
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
3,56
.140
0,01-0,05
.0004.0020
33,32±1,14
1.312±.045
BZ-2AQ18T1
Double-break
circuitry
15 Amps
T
3,89-6,68
14-24
1,11
4
0,51
.020
3,58
.141
0,03-0,10
.001-.004
33,35±1,19
1.313±.047
BM-1RQ18-A2
Up to 22 ampere load
handling
22 Amps
F
1,95-2,78
7-10
1,11
4
0,38
.015
3,56
.140
0,0130,025
.0005.0010
33,32±1,14
1.312±.045
BZ-2RQ181-A2
Applications requiring
roller plunger 90° to major
axis of switch
15 Amps
A
2,5-3,61
9-13
1,11
4
0,38
.015
3,56
.140
0,01-0,05
.0004.0020
33,32±1,14
1.312±.045
Dim. Dwg. Fig. 16
BZ/BM TYPE
BZ-2RQ1T04
(M8805/1-020)
Dim. Dwg. Fig. 17
BA TYPE
Dim. Dwg. Fig. 19
* Reset characteristics.
Dim. Dwg. Fig. 20
For application help: call 1-800-537-6945.
Except where stated ** ±0,76 mm
±.030 in.
Honeywell Sensing and Control
51
Standard
Basic Switches
Dim. Dwg. Fig. 18
Basic Switches
Standard
BZ/BA Series
Characteristics: O.F. — Operating Force; R.F. — Release Force;
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel;
O.P. — Operating Position.
STRAIGHT LEVER
ORDER GUIDE
Recommended
For
Catalog Listing
BZ-2RW8072-A2
D.T.
mm
inches
O.P.**
mm
inches
1 Amp
P
0,7
2.5
0,14
0.5
—
5,56
.219
0,18-1,27
.007-.050
19,1
.750
Best stability under
varying humidity.
Gold alloy contacts
with seal
1 Amp
P
0,7
2.5
0,14
0.5
—
5,56
.219
0,18-1,27
.007-.050
19,1
.750
Operating in temp.
to +400°F (204°C)
for 100 hours
5 Amps
B
0,7
2.5
0,14
0.5
—
5,56
.219
0,18-1,27
.007-.050
19,1
.750
Lowest operating
force (without
external return
spring)
10 Amps
I
0,07
.25
—
6,76
.266
5,56
.219
0,08-0,38
.003-.015
19,1
.750
1.25 inch lever
requirements
15 Amps
A
1,67
6
0,42
1.5
—
0,42
.141
0,10-0,63
.004-.025
19,1
.750
2.5 inch lever
requirements
15 Amps
A
0,7
2.5
0,14
0.5
—
5,56
.219
0,18-1,27
.007-.050
19,1
.750
BZ-2RW84-A2
Lower force (without
external return
spring)
15 Amps
A
0,28
1
0,03
0.125
8,33
.328
5,56
.219
0,18-1,27
.007-.050
19,1
.750
BZ-2RW805551-A2
Dustproof and
splash resistant seal
15 Amps
A
0,7
2.5
0,14
0.5
—
5,56
.219
0,18−1,27
.007-.050
19,1
.750
MIL-S-8805
application
requirements
15 Amps
A
0,28-0,90
1-3.25
0,21
0.75
7,52
.296
4,37
.172
2,36
.093
19,1
.750
Operating in
temperature to
+250°F (121°C)
15 Amps
A
0,7
2.5
0,14
0.5
—
5,56
.219
0,18-1,27
.007-.050
19,1
.750
BZ-RW80X
Manual reset solder
terminals
15 Amps
E
0,63
2.25
—
—
—
—
5,56
.219
0,38*
.015
—
—
–
–
19,05
.750
7,14*
.281
BZ-2RW863-A2
6 inch lever
requirements
15 Amps
A
0,28
1
—
—
12,7
.500
BA-2RV-A2
Up to 20 ampere
load handling
20 Amps
G
0,7
2.5
0,14
0.5
15,88
.625
1,98
.078
2,77
.109
19,1
.750
BM-1RW84-A2
Up to 22 ampere
load handling
22 Amps
F
0,28
1
0,03
0.125
7,54
.297
5,56
.219
0,13-0,84
.005-.033
19,1
.750
BE-2RV-A4
Up to 25 ampere
load handling
25 Amps
H
0,7
2.5
0,14
0.5
15,88
.625
1,98
.078
2,77
.109 max.
19,1
.750
Adjustable
operating point (17
mm to 22 mm) .670N
to .880N
15 Amps
A
0.7
2.5
0.14
0.5
—
3,54 †
.125
0,18-1,27 17,02-22,35
.007-.050 .670-.880
Reverse acting
actuator (switch
plunger depressed
in free position)
15 Amps
A
1,67
6
0,28
1
5,56
.219
5,56
.219
0,10-0,89
.004-.035
BZ-2RW80722555105-A2
BZ-2RW8244-A2
BZ-RW8435-A2
Dim. Dwg. Fig. 21
BZ-2RW876T
BZ-2RW80-A2
BA TYPE
BZ-2RWT04
(M8805/1-044)
BZ-2RW824-A2
ADJUSTABLE
O.T. min.
mm
inches
Applications
requiring gold alloy
contacts
BZ/BM TYPE
Dim. Dwg. Fg. 23
Electrical
Data and O.F. max. R.F. min. P.T. max.
UL Codes newtons newtons
mm
Page 46
ounces ounces inches
* Reset characteristics.
BZ-2RW899-A2
BZ-2RM-A2
Dim. Dwg. Fg. 22
† From17 mm O.P.
.670 in.
Honeywell Sensing and Control
19,1
.750
Except where stated ** ±0.76 mm
±.030 in.
Dim. Dwg. Fig. 24
52
0,46-3,68 19,1±1,52
.018-.145 .750±.060
For application help: call 1-800-537-6945.
Basic Switches
Standard
BZ/BA Series
SIMULATED ROLLER
ORDER GUIDE
Catalog
Listing
BZ-2RW80147-A2
Electrical
Data And
UL Code
Recommended For Page 46
O.F.
R.F.
P.T.
max.
min.
max.
newtons newtons
mm
ounces ounces inches
O.T.
min.
mm
inches
D.T.
mm
inches
O.P.**
mm
inches
30,17
1.188
1.05 inch (26,7 mm)
(simulated roller)
lever applications
15 Amps
A
1,67
6
0,42
1.5
—
2,39
.094
0,08-0,51
.003-.020
1.90 inch (48,3 mm)
(simulated roller)
lever applications
15 Amps
A
0,97
3.5
0,21
0.75
—
3,96
.156
0,10-1,0 30,17±0,76
.004-.040 1.188±.030
Applications
requiring gold alloy
contacts
1 Amp
P
1,67
6
0,42
1.5
—
2,39
.094
0,08-0,51
.003-.020
30,17
1.188
Applications
requiring gold alloy
contacts plus
dustproof and splash
resistant seal
1 Amp
P
1,67
6
0,42
1.5
—
2,39
.094
0,08-0,51
.003-.020
30,17
1.188
1.05 inch (26,7 mm)
(steel roller) lever
applications
15 Amps
A
1,67
6
0,42
1.5
—
2,39
.094
0,08-0,51
.003-.020
30,17
1.188
BZ-2RW8222-A2
Roller turned 90°
15 Amps
A
0,7-1,81
2.5-6.5
0,35
1.25
—
3,58
.141 max.
0,08-0,51
.003-.020
30,75
1.25
BZ-2RW82224-A2
Operating in
temperature to
+250°F (121°C)
15 Amps
A
1,67
6
0,42
1.5
—
2,39
.094
0,08-0,51
.003-.020
30,17
1.188
Dustproof and
splash resistant seal
15 Amps
A
1,67
6
0,42
1.5
—
2,39
.094
0,08-0,51
.003-.020
30,17
1.188
Best service for
sealed construction.
Stainless steel
internal snap spring.
15 Amps
A
1,67
6
0,42
1.5
—
2,39
.094
0,08-0,51
.003-.020
30,17
1.188
BA-2RV22-A2
Up to 20 ampere
load handling
20 Amps
G
1,67
6
0,42
1.5
6,35
.250
0,76
.030
1,14
.045 max.
29,77
1.172
BM-1RW822-A2
Up to 22 ampere
load handling
22 Amps
F
1,67
6
0,42
1.5
—
2,39
.094
0,025-0,33
.001-.013
30,17
1.188
BE-2RV22-A4
Up to 25 ampere
load handling
25 Amps
H
1,67
6
0,42
1.5
6,35
.250
0,76
.030
1,14
.045 max.
29,77
1.172
BZ-2RW82299-A2
Adjustable operating
point. Roller lever
1.05 inch (26,7 mm)
15 Amps
A
1,67
6
0,42
1.5
—
1,02
.040
0,08-0,51 29,77-30,56
.003-.020 1.172-1.203
Adjustable operating
point. Roller lever
1.90 inch (48,3 mm)
15 Amps
A
0,97
3.5
0,21
0.75
—
2,16
.085
0,10-1,0
.004-.040
BZ-2RW80196-A2
Dim. Dwg. Fig. 27
ROLLER LEVER
BZ-2RW82272-A2
BZ-2RW822725551-A2
BZ/BM TYPE
BZ-2RW822-A2
Dim. Dwg. Fig. 25
BZ-2RW8225551-A2
Dim. Dwg. Fig. 28
BA/BE TYPE
BZ-2RW8299-A2
29,2-31,5
1.150-1.24
Dim. Dwg. Fig. 26
Except where stated * ±0,38 mm
±.015 in.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
53
Standard
Basic Switches
BZ-2RW82255-A2-S
Basic Switches
Standard
ROLLER LEVER
BZ/BM TYPE
BZ/BA Series
ORDER GUIDE
Catalog
Listing
Recommended
For
BZ-2RW82725551-A2
Applications requiring
gold alloy contacts,
plus dustproof, and
splash resistant seal
BA/BE TYPE
Dim. Dwg. Fig. 30
Electrical
Data And
UL Code
Page 46
O.F.
R.F.
max.
min.
newtons newtons
ounces ounces
P.T.
max.
mm
inches
O.T.
min.
mm
inches
D.T.
mm
inches
O.P.*
mm
inches
1 Amp
P
0,97
3.5
0,21
0.75
—
3,96
.156
0,10-1,0
.004-.040
30,17±0,76
1.188±.030
1.90 inch (48,3 mm)
(steel roller) lever
applications
15 Amps
A
0,97
3.5
0,21
0.75
—
3,96
.156
0,10-1,0
.004-.040
30,17±0,76
1.188±.030
Dustproof and splash
resistant seal
15 Amps
A
0,97
3.5
0,21
0.75
—
3,96
.156
0,10-1,0
.004-.040
30,17±0,76
1.188±.030
Operating in
temperature to
+250°F (121°C)
15 Amps
A
0,97
3.5
0,21
0.75
—
3,96
.156
0,10-1,0
.004-.040
30,17±0,76
1.188±.030
BA-2RV2-A2
Up to 20 ampere load
handling
20 Amps
G
0,97
3.5
0,14
0.5
11,89
.468
1,52
.060
2,16
.085
30,17±0,76
1.188±.030
BM-1RW82-A2
Up to 22 ampere load
handling
22 Amps
F
0,97
3.5
0,21
0.75
—
3,96
.156
0,08-0,56
.003-.022
30,17±0,76
1.188±.030
Up to 25 ampere load
handling
25 Amps
H
0,97
3.5
0,14
0.5
11,89
.468
1,52
.060
2,16
.085 max.
30,17±0,76
1.188±.030
BZ-2RW82-A2
Dim. Dwg. Fig. 29
Characteristics:
O.F. — Operating Force; R.F. — Release Force; P.T. — Pretravel;
O.T. — Overtravel; D.T. — Differential Travel;
O.P. — Operating Position.
BZ-2RW825551-A2
BZ-2RW8224-A2
BE-2RV2-A4
NOTE: For adjustable operate point and simulated roller lever switches, refer to previous page.
BZ-RW922-A2
Best repeatability and
O.P. stability
10 Amps
I
3,34
12
1,11
4
0,38
.015
2,54
.100
0,013-0,025
.0005-.0010
31,37
1.235
BZ-2RW826-A2
One-way roller (9,4
mm H 3,8 mm) .37N
dia. H .15N wide roller
15 Amps
A
1,67
6
0,42
1.5
—
2,39
.094
0,08-0,51
.003-.020
41,34
1.625
One-way roller (4,83
mm H 4,83 mm) .19N
dia. H .19N wide roller
15 Amps
A
2,22
8
0,42
1.5
—
1,52
.060
0,38
.015
28,96
1.14
Dim. Dwg. Fig. 31
BZ-2RW825-A2
Dim. Dwg. Fig. 32
54
Honeywell Sensing and Control
Except where stated * ±0,38 mm
±.015 in.
For application help: call 1-800-537-6945.
Basic Switches
Standard
FLEXIBLE LEAF
BZ/BA Series
ORDER GUIDE
Electrical
Data and
UL Codes
Page 46
O.F. max.
newtons
ounces
Force and stability of the
flexible leaf actuator
15 Amps
A
1,39
5
0,14
0.5
–
1,52
.060
1,27
.050
17,48
.688
Dustproof and splash
resistant seal
15 Amps
A
1,95
7
0,14
0.5
–
1,52
.060
1,27
.050
17,48
.688
BZ-2RLT04
(M8805/1-001)
MIL-S-8805 application
requirements
15 Amps
A
1,39
5
0,14
0.5
–
1,52
.060
1,27
.050
17,48
.688
BZ-2RL24-A2
Operating in temperature
to +250°F (121°C)
15 Amps
A
1,39
5
0,14
0.5
–
1,52
.060
1,27
.050
17,48
.688
BZ-RLX
Manual reset.
Solder terminals
15 Amps
E
0,83
3
–
–
–
–
1,57
.062
0,38*
.015
–
–
–
–
17,48
.688
7,14*
.281
BA-2RL-A2
Up to 20 ampere load
handling
20 Amps
G
2,5
9
0,28
1
–
1,57
.062
1,57
.062
17,48
.688
Up to 25 ampere load
handling
25 Amps
H
2,5
9
0,28
1
–
1,57
.062
1,57
.062
17,48
.688
Electrical
Data and
UL Codes
Page 46
O.F. max.
newtons
ounces
Operating in temp. to
+250°F (121°C)
for 100 hours
5 Amps
B
1,39
5
0,14
0.5
–
1,52
.060
1,27
.050
28,6
1.125
Force and stability of the
flexible leaf with roller
15 Amps
A
1,39
5
0,14
0.5
–
1,52
.060
1,27
.050
28,6
1.125
Dustproof and splash
resistant seal
15 Amps
A
1,95
7
0,14
0.5
–
1,52
.060
1,27
.050
28,6
1.125
BZ-2RL2T04
(M8805/1-036)
MIL-S-8805 application
requirements
15 Amps
A
1,04-1,39
3.75-5
0,14
0.5
–
1,52
.060
1,27
.050
28,6
1.125
BA-2RL2-A2
Up to 20 ampere load
handling
20 Amps
G
2,5
9
0,28
1
–
1,52
.060
1,65
.065
28,6
1.125
Up to 25 ampere load
handling
25 Amps
H
2,5
9
0,28
1
–
1,52
.060
1,65
.065
28,6
1.125
Catalog Listing
BZ TYPE
BZ-2RL-A2
BZ-2RL5551-A2
Dim. Dwg. Fig. 33
BA/BE TYPE
Dim. Dwg. Fig. 34
BE-2RL-A4
FLEXIBLE
ROLLER LEAF
BZ TYPE
Catalog Listing
BZ-2RL25551-A2
BA/BE TYPE
BE-2RL2-A4
Recommended For
R.F. min. P.T. max. O.T. min. D.T. max.
newtons
mm
mm
mm
ounces
inches
inches
inches
* Reset characteristics
For application help: call 1-800-537-6945.
O.P.*
mm
inches
** ±0.76 mm
±.030 in.
Honeywell Sensing and Control
55
Standard
Basic Switches
BZ-2RL2-A2
Dim. Dwg. Fig. 36
O.P.**
mm
inches
ORDER GUIDE
BZ-RL24-A2
Dim. Dwg. Fig. 35
Recommended For
R.F. min. P.T. max. O.T. min. D.T. max.
newtons
mm
mm
mm
ounces
inches
inches
inches
Basic Switches
Standard
BZ/BA Series
GENERAL INFORMATION
SPECIAL CIRCUITRY SWITCHES
‘‘Special sequence’’ switches provide unusual circuit control. A make-beforebreak switch provides circuit continuity
while switching from N.C. to N.O. In another make-before-make switch, upon
actuation, one circuit is made an interval
before the second circuit. Another switch
provides a single pulse or momentary
closure of the contacts with each cycle of
operation.
Double break versions can interrupt greater inductive loads and feature shorting
bar construction. A split contact version
allows control of the two isolated circuits.
Characteristics: O.F. – Operating Force;
R.F. – Release Force; P.T. – Pretravel;
O.T. – Overtravel; D.T. – Differential Travel;
O.P. – Operating Position.
PIN PLUNGER
ORDER GUIDE
Catalog Listing
BZ-2G-A2
Dim. Dwg. Fig 5
Unoperated
Intermediate
6BS1-B
Recommended For
Make-before-break
contact action
Fully
Operated
Make-before-make
contact action
Electrical
Data and
UL Codes
Page 46
O.F.
newtons
ounces
10 Amps
C
5,56
20 max.
R.F. min. P.T. max. O.T. min.
newtons
mm
mm
ounces
inches
inches
2,22
8
Intermediate
Release
10 Amps
R
9,73
35 max.
0,76
.030
D.T.
mm
inches
O.P.*
mm
inches
0,13
.005
0,38
.015
15,9
.625
–
–
–
Fully
Released
2,78
10
–
Dim. Dwg. Fig. 6
*±0,38 mm
± .015 in.
10BS210
Adjustable
differential travel
20 Amps
Y
3,10-5,56
11-20
2,78
10
–
0,25
.010 at
max.
setting
0,04-0,06
.0015-.0025
0,18
.007 at max.
setting
Dim. Dwg. Fig. 4-A
56
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
16,3
.64
Basic Switches
Standard
BZ/BA Series
PIN PLUNGER —
SPECIAL CIRCUITRY
ORDER GUIDE
Recommended For
Electrical
Data and
UL Codes
Page 46
BZ-3AT
Double-break, low
voltage DC applications
15 Amps
T
4,45-7,23
16-26
1,11
4
0,76
.030
0,13
.005
0,051-0,13
.002-.005
15,9
.625
BZ-2AW80T
As above, with
2.5 inch lever
15 Amps
T
0,90
3.25
0,14
.25
–
–
5,56
.219
0,51
2.54
19,05±0,76
.750±.030
BZ-2AW82T
As above, with
1.9 inch roller lever
15 Amps
T
1,25
4.5
0,21
.75
–
–
3.96
.156
0,38-1,91
.015-.075
30,18±0,76
1.188±.030
BZ-2AW822T
As above, with
1.05 inch roller lever
15 Amps
T
2,36
8.5
0,42
1.5
–
–
2,39
.094
0,20-2,39
.008-.030
30,18±0,76
1.188±.030
BA-3ST
Double-break, low
voltage DC applications
25 Amps
M
7,23-10,6
26-38
2,78
10
1,65
.065
0,25
.010
0,18-0,38
.007-.015
16,3
.640
BZ-3YT
(MS25383-1)
MIL-S-8805 application
requirements. (split
contact)
5 Amps
U
4,45-7,23
16-26
1,11
4
0,76
.030
0,13
.005
0,025-0,1
.001-.004
15,9
.625
BZ-3YWT80
As above, with
2.50 inch lever
5 Amps
U
0,97
3.5
0,14
.5
–
–
5,56
.219
0,51-2,54
.020-.100
19,05±0,76
.750±.030
BZ-3YWT82
As above, with
1.9 inch roller lever
5 Amps
U
1,25
4.5
0,21
.75
–
–
3,96
.156
0,38-1,91
.015-.075
30,18±0,76
1.188±.030
BZ-3YWT822
As above, with
1.05 inch roller lever
5 Amps
U
1,95
7
0,42
1.5
–
–
2,39
.094
0,20-1,02
.008-.040
30,19
.188
Catalog Listing
Dim. Dwg. Fig. 8
O.F.
newtons
ounces
R.F. min. P.T. max. O.T. min.
newtons
mm
mm
ounces
inches
inches
D.T.
mm
inches
O.P.*
mm
inches
Dim. Dwg. Fig. 9
Except where stated * ±0,38 mm
±.015 in.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
57
Standard
Basic Switches
Dim. Dwg. Fig. 10
Basic Switches
Standard
BZ/BA Series
MOUNTING DIMENSIONS (For reference only)
PIN PLUNGERS
BZ/BM
BA/BE
Fig. 1
Fig. 2
Fig. 4
Fig. 4-A
Fig. 3
PIN PLUNGERS — SPECIAL
CIRCUITRY
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Mounting holes accept pins or screws of
.139 N (3,53 mm) diameter.
58
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Standard
BZ/BA Series
MOUNTING DIMENSIONS (For reference only)
OVERTRAVEL PLUNGERS
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
*Fig. 17
*Fig. 19
*Fig. 20
Standard
Basic Switches
Fig. 11
*Fig. 18
* Threaded bushings are 15/32-32ns.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
59
Basic Switches
Standard
BZ/BA Series
MOUNTING DIMENSIONS (For reference only)
STRAIGHT LEVERS
Fig. 21
Fig. 22
Fig. 23
Fig. 24
Fig. 25
Fig. 26
FLEXIBLE LEAF ACTUATOR
Fig. 33
60
Honeywell Sensing and Control
Fig. 34
For application help: call 1-800-537-6945.
Basic Switches
Standard
BZ/BA Series
MOUNTING DIMENSIONS
ROLLER LEVERS
Fig. 28
Fig. 29
Fig. 30
Fig. 31
Fig. 32
FLEXIBLE ROLLER LEAF
Mounting holes accept pins or screws of
.139N (3,53 mm) diameter.
Fig. 35
For application help: call 1-800-537-6945.
Fig. 36
Honeywell Sensing and Control
61
Standard
Basic Switches
Fig. 27
Basic Switches
Auxiliary Actuators Standard Basic
FEATURES
1 Additional overtravel
1 Quick, easy installation
1 Corrosion resistance
1 MIL-S-8805 listed units
NOTE: Switches shown are not included with the actuator. All actuators are
for use with pin plunger types only except catalog listing JR.
GENERAL INFORMATION
Auxiliary actuators adapt the plungertype standard basic switches to many application needs. Auxiliary actuators minimize the need for a large inventory of
switch types. Actuators and switches are
sold as separate items and must be ordered separately. Mounting hardware is
furnished with the actuator.
Characteristics:
O.T. — Overtravel;
O.P. — Operating Position;
F.P. — Free Position.
ORDER GUIDE
Description
Catalog
Listing
Use
Only
With
O.T. min.
mm
inches
O.P.*
mm
inches
F.P. max.
mm
inches
Roller lever for ‘‘S’’ plunger type
BZ and DT switches only.
Permits cam operation.
JR
BZ
DT
11.1
.437
44,45±3,18
1.75±.125
Adjustable roller lever. Tang on
top of actuator can be bent to
adjust O.P. and F.P.
AD5721R
(8805/59)
AN3169-1
BZ
BM
11,1
.437
approx.
31,75-41,15
1.25-1.62
39,6-43,7
1.56-1.72
ADA3721R
BA
BE
9,53
.375
approx.
40,48
1.594
approx.
43,03
1.812
ADD3721R
DT
MT
9,53
.375
approx.
39,6
1.562
approx.
46,03
1.812
MC2711
(8805/59)
AN3168-2
BZ
BM
4,78
.188
27,79
.188
29,4
1.156
MCA2711
BA
BE
3,96
.156
28,17
1.109
30,18
1.188
MCD2711
DT
MT
3,58
.141
27,79
1.094
30,18
1.188
Fig. 1
Fig. 2
Straight plunger. Panel mount.
Fig. 3
Dimensions shown are for reference only.
62
Honeywell 1 MICRO SWITCH Sensing and Control
Except where stated * ±1,14 mm
±.045 in.
For application help: call 1-800-537-6945.
Basic Switches
Auxiliary Actuators Standard Basics
ORDER GUIDE
Description
Fig. 4
Sealed straight plunger.
Panel mount. Elastomer seal
boot keeps out liquid splash
and dirt. Furnished
unassembled.
Fig. 5
Cross roller plunger. Panel
mount. Roller perpendicular
to long axis of the switch.
Fig. 7
High overtravel plunger.
Panel mount.
Use O.T. min.
Only
mm
With Inches
O.P.*
mm
Inches
F.P. max.
mm
Inches
MC2711H
BZ
BM
4,78
.188
28,98
1.141
29,4
1.156
MCA2711H
BA
BE
4,37
.172
27,38±0,76
1.078±.030
29,56
1.156
MCD2711H
DT
MT
3.58
.141
27,79
1.094
30,18
1.188
MD3211Q
BZ
BM
3,18
.125
approx.
35,7
1.406
37,69
1.484
MDA3711Q
BA
BE
3,18
.125
36,12
1.422
37,69
1.484
MD3211Q
DT
MT
3,18
.125
35,7
1.406
37,69
1.484
MD3211Q1
BZ
BM
3,18
.125
approx.
35,7
1.406
37,69
1.484
MDA3711Q1
BA
BE
3,18
.125
36,12
1.422
37,69
1.484
MD3211Q1
DT
MT
3,18
.125
35,7
1.406
37,69
1.484
MC7711
(8805/58)
AN3167-1
BZ
BM
20,62
.812
69,1
2.719
70,64
2.781
MCA7711
BA
BE
19,84
.781
69,44
2.734
71,42
2.812
MCD7711
DT
MT
18,26
.719
69,1
2.719
71,42
2.812
Except where stated* ±1,14 mm
±.045 in.
For application help: call 1-800-537-6945.
Honeywell nsing and Control
63
Standard
Basic Switches
Fig. 6
Roller plunger. Panel mount.
Roller parallel to long axis of
the switch.
Catalog
Listing
Basic Switches
Accessories Standard Basics
DIE CAST ZINC ENCLOSURES
FEATURES
1 Protect switch from physical abuse
1 Protect personnel from contact with exposed terminals
1 Provide rugged mounting means
1 1/2-14NPT internal thread conduit hub
Width of opening .74N (18,8 mm)
3PA1
3PA2*
*Width of base is 2.125 inches (54 mm)
and mounting hole centers are 1.625
inches (41,3 mm) apart.
ORDER GUIDE
Catalog Listing
Description
3PA1
Side mount enclosure–Can be mounted from either side through
.140N (3,55mm) dia. holes on 1N (25,4mm) centers.
3PA28
Side mount enclosure–Can be mounted from either side through
.140N (3,55mm) dia. holes on 1N (25,4mm) centers. 1/2-14 NPSM
internal thread conduit hub.
3PA2
Flange mount enclosure—Switch is first secured in enclosure; two
0.172N (4,37mm) dia. holes in the flange accept #8 machine screws
for mounting on 1.625 (41,3mm) centers.
3PA6
Side mount enclosure—For use with actuator Fig. 2 page 58.
PLASTIC TERMINAL ENCLOSURES
FEATURES
1 Easy to use
1 Screw and solder terminal versions
1 Protect personnel from contact with
exposed terminals
5PA1
5PA1 WITH SWITCH
ASSEMBLY
ORDER GUIDE
Catalog Listing
5PA2
Description
5PA1
For solder terminal switches
5PA2
For screw terminal switches
5PA3
For solder or screw terminal switches with auxiliary actuators
assembled.
Dimensions shown are for reference only.
Switches are not included with
enclosures.
64
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Accessories Standard Basics
ADJUSTABLE MOUNTING BRACKETS
FEATURES
1 Sturdy plated steel construction
1 Fast, easy screwdriver adjustment
1 Can be used with all standard basic
switches
GENERAL INFORMATION
The operation point of a basic switch can
be regulated up to .080′ (2 mm) by loosening the locking screw, inserting a
screwdriver in the adjusting slot, and
twisting.
ORDER GUIDE
Catalog Listing
8MA1 WITH SWITCH
ASSEMBLED
Description
8MA1
Adjustable mounting bracket, adjustment slot on the left.
8MA2
Adjustable mounting bracket, adjustment slot on the right.
MOUNTING DIMENSIONS
‘A’ Dimension for
BZ Type 3,6/.14
BA Type 7,8/.31
CONVERSION MOUNTING BRACKET
Standard
Basic Switches
17MA1-B
FEATURES
1 Converts standard basic switches
from side to top mount
1 Corrosion resistant
1 Snaps into switch mounting holes—
without tools
ORDER GUIDE
Catalog Listing
17MA1-B
Description
Conversion mounting bracket.
17MA1-B WITH SWITCH
ASSEMBLED
MOUNTING DIMENSIONS
Switches are not included with bracket.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
65
Basic Switches
Double-pole Double-throw
DT Series
FEATURES
1 Two independent single-pole doublethrow circuits on one housing
1 Design permitting several wiring
combinations
1 Savings in space and weight
1 Mounting interchangeability with type
Z switches
1 Temperature tolerance to +180°F
(82°C)
1 UL recognized, CSA certified
ELECTRICAL RATING
Circuitry
Double-pole
double-throw
DOUBLE-POLE
DOUBLE THROW
Electrical Data and
UL Codes
AVAILABLE TERMINALS
B6
6-32 UNC H .188 N
(No. 5 pan head screws)
A7
4-40 UNC H .125 N
Screws with lockwashers.
Fiberglas insulator isolates
terminals and prevents
accidental shorting.
J 10 amps, 125 or 250 vac;
0.3 amp, 125 vdc; 0.15 amp,
250 vdc.
UL Code L59
Characteristics: O.F. — Operating Force; R.F. — Release Force;
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel;
O.P. — Operating Position.
ORDER GUIDE
Catalog Listing
Description
Electrical
Data and
UL Code
O.F.
max.
newtons
ounces
R.F.
min.
newtons
ounces
P.T.
max.
mm
inches
O.T.
mm
inches
D.T. max.
min.
mm
inches
O.P.*
mm
inches
DT-2R-A7
MS25008-1
Pin plunger
10 Amps
J
3,34-5,56
12-20
0,56
2
1,91
.075
0,13
.005
1,02-1,52
.040-.060
15,6
.615±.015
DT-2RS1-A7
Straight plunger
10 Amps
J
3,34-5,56
12-20
0,28
1
1,91
.075
0,51
.020
1,02-1,52
.040-.060
28,2±0,38
1.11±.015
DT-2RV3-A7
Straight lever
Reversed lever
position
10 Amps
J
1,11-1,95
4-7
0,14
0.5
6,86
.270
0,25
.010
2,92-4,83
.115-.190
18,3
.719
DT-2RV-A7
Straight lever
10 Amps
J
0,97-1,67
3.5-6
0,28
1
25,4
1
1,57
.062
12,4-19,2
.490-.755
21,8
.859
Dim. Dwg. Fig. 1
Dim. Dwg. Fig. 9
Dim. Dwg. Fig. 3
Except where stated * ±0,76 mm
±.030 in.
Dim. Dwg. Fig. 2
66
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Double-pole Double-throw
DT Series
ORDER GUIDE
Catalog Listing
Recommended For
Electrical O.F. max.
Data and newtons
UL Codes ounces
R.F. min.
newtons
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T. max.
mm
inches
O.P.*
mm
inches
DT-2RV216-A7
Roller lever
(centered steel roller)
10 Amps
J
11,1
2.5 lbs.
1,11
4
1,02
.040
0,13
.005
0,51-0,76
.020-.030
31
1.219
DT-2RV22-A7
1.03 inch (26,2mm) roller
lever (steel roller)
10 Amps
J
2,5-3,89
9-14
0,83
3
–
0,79
.031
4,95-7,75
.195-.305
30,2±0,38
1.188±.015
DT-2RV212-A7
Roller lever
Reversed lever position
10 Amps
J
2,5-4,17
9-15
0,42
1.5
3,3
.130
0,13
.005
1,27-2,16
.050-.085
29,4
1.156
DT-2RV23-A7
Roller lever
Reversed lever position
10 Amps
J
1,53-2,64
5.5-9.5
0,21
.75
4,45
.175
0,25
.010
2,16-3,43
.085-.135
29,4
1.156
DT-2RV2-A7
1.90 inch (48,3 mm) roller
lever (steel roller)
10 Amps
J
1,25-2,09
4.5-7.5
0,42
1.5
—
—
1,19
.047
9,27-14,4
.365-.565
31,8
1.250
Dim. Dwg. Fig. 8
Dim. Dwg. Fig. 5
Standard
Basic Switches
Dim. Dwg. Fig. 7
Dim. Dwg. Fig. 6
Except where stated * ±0,76 mm
±.030 in.
Dim. Dwg. Fig. 4
Auxiliary actuators see page 68-69.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
67
Basic Switches
Double-pole Double-throw
DT Series
MOUNTING DIMENSIONS (For reference only)
68
PIN PLUNGER
STRAIGHT LEVER
Fig. 1
Fig. 2
STRAIGHT LEVER
ROLLER LEVER
Fig. 3
Fig. 4
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Double-pole Double-throw
DT Series
MOUNTING DIMENSIONS (For reference only)
ROLLER LEVER
Fig. 5
Fig. 6
ROLLER LEVER
ROLLER LEVER
Fig. 7
Fig. 8
Standard
Basic Switches
ROLLER LEVER
STRAIGHT PLUNGER
Fig. 9
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
69
Basic Switches
Magnetic Blow-out
MT Series
FEATURES
1 Arc resistant case
1 Mechanical life of 100,000 operations
— 95% survival
1 Temperature tolerance to +180°F
(82°C)
1 Mounting interchangeability with Z
switches
1 UL recognized
GENERAL INFORMATION
MT (single-pole double-throw) magnetic
blow-out switches are designed to switch
high capacity (125 and 250 VDC) systems. An integral magnet around the contact gap protects the contacts by deflecting the arc. Vents between the cover and
housing allow the hot gas to escape.
These switches are designed for the control of DC motors, solenoids, etc.
AVAILABLE TERMINALS
Solder (No listing designation)
A28
6-32NC H .218N Screws
will accept up to #12 wire.
ELECTRICAL RATING
Electrical Data and
UL Codes
Circuitry
Single-pole
double-throw
unless
otherwise noted
in order guide
K Rating established with
switch non-polarized
10 amps, 125 vac or vdc;
1/4 hp, 125 vac or vdc.
UL Code L 168
Non-polarized:
10 amps res. or 1/4 hp, 125 vdc;
3 amps max. res. 250 vdc.
Polarized*:
10 amps res. or 1/2 hp, 125 vdc;
3 amps max. res., 250 vdc.
*To polarize, connect negative side of line to common terminal. To
achieve the same effect, mount switch with brass screws, using a
non-magnetic barrier (at least 1⁄4 N thick) between the switch and
mounting surface.
Characteristics: O.F. – Operating Force;
R.F. – Release Force; P.T. – Pretravel;
O.T. – Overtravel; D.T. – Differential Travel;
O.P. – Operating Position.
ORDER GUIDE
Catalog Listing
MT-4R-A28
Recommended For
Pin plunger
SPDT
Electrical
Data and
UL Codes
O.F.
newtons
ounces
R.F. min.
newtons
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T. max.
mm
inches
O.P.
mm
inches
10 Amps
K
3,34-5,0
12-18
1,39
5
1,02
.04
0,13
.005
0,1-0,18
.004-.007
15,9±0,38
.625±.015
Dim. Dwg. Fig. 1
70
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Magnetic Blow-out
MT Series
ORDER GUIDE
Catalog Listing
Description
Electrical O.F. max.
Data and newtons
UL Codes ounces
R.F. min.
newtons
ounces
P.T. max.
mm
inches
O.T. min.
mm
inches
D.T. max.
mm
inches
O.P.*
mm
inches
MT-4RV-A28
Straight lever
10 Amps
K
0,56
2
0,14
0.5
12,7
0.5
1,19
.047
2,16
.085
19,1
.750
MT-4RV2-A28
1.90 inch (48,3mm) lever
with hardened steel roller
10 Amps
K
0,76
2.75
0,07
0.25
8,89
0.35
0,79
.031
1,65
.065
30,2
1.188
MT-4RV22-A28
1.03 inch (26,2mm) lever
with hardened steel roller
10 Amps
K
1,25
4.5
0,28
1
5,08
.200
0,38
.015
0,89
.035
31,3
1.234
MT-4RL-A28
1.95 inch (49,5mm)
flexible leaf
10 Amps
K
3,34
12
0,28
1
—
1,52
.060
max.
—
19,1
.750
1.82 inch (46,2mm)
flexible leaf with hardened
steel roller
10 Amps
K
3,34
12
0,28
1
—
1,52
.060
max.
—
30,2
1.188
Dim. Dwg. Fig. 2
Dim. Dwg. Fig. 3
Dim. Dwg. Fig. 4
Dim. Dwg. Fig. 5
For application help: call 1-800-537-6945.
Except where stated * ±0,76 mm
±.030 in.
Honeywell Sensing and Control
71
Standard
Basic Switches
MT-4RL2-A28
Basic Switches
Magnetic Blow-out
MT Series
MOUNTING DIMENSIONS (For reference only)
PIN PLUNGER
STRAIGHT LEVER
Fig. 1
Fig. 2
ROLLER LEVER
FLEXIBLE LEAF
Fig. 3
Fig. 4
FLEXIBLE ROLLER LEAF
Fig. 5
Mounting holes accept pins or screws of
.139 N (3,53 mm) diameter.
72
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Double-break
3MN Series
FEATURES
1 .080 inch minimum overtravel
1 Power load switching capability up to
15 amperes
1 Motor handling capacity of 1 horsepower at 240 vac.
1 Long mechanical life of 10,000,000 cycles—95% survival
1 Arc resistant plastic
1 More space between terminals to reduce possibility of shorting
1 #8 Terminal screws
1 UL recognized, CSA certified
GENERAL INFORMATION
3MN switches are for use with limit or control mechanisms on machine tools,
presses or other industrial equipment.
These switches provide easy gang
mounting.
The terminals of double-break switches
must be wired to identical voltage sources and the same polarity. The loads
should be on the same sides of the lines.
ELECTRICAL RATING
Electrical Data and
UL Codes
Circuitry
Two-circuit
double-break
V Motor Control
15 amps, 120, 240, 480 or 600 vac;
1/2 hp, 120 vac; 1 hp, 240 vac;
0.8 amp, 115 vdc; 0.4 amp,
230 vdc.
Characteristics: O.F. — Operating Force; R.F. — Release Force; P.T.
— Pretravel; O.T. – Overtravel; D.T. — Differential Travel; O.P. — Operating
Position.
ORDER GUIDE
Description
O.F.
newtons
ounces
R.F.
min.
newtons
ounces
P.T.
max.
mm
inches
O.T.
min.
mm
inches
D.T.
mm
inches
O.P.* max.
mm
inches
2,16
.085
3MN1
For most
applications
15 Amps
V
3,34-5,56
12-20
1,67
6
1,52
.060
2,03
.080
0,38-0,63
.015-.025
3MN6
Lower force
15 Amps
V
1,95-3,1
7-11
1,11
4
1,52
.060
2,03
.080
0,38-0,63
.015-.025
Dim. Dwg. Fig. 1
MOUNTING DIMENSIONS (For reference only)
Fig. 1
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
73
2,16
.085
* ±0,38 mm
±.015 in.
Standard
Basic Switches
Catalog
Listing
Electrical
Data and
UL Codes
Basic Switches
Tandem Switch Assemblies
6AS Series
FEATURES
1 Variety of actuators
1 Choice of circuitries and electrical
ratings
1 Choice of terminations
1 Field adjustable operating point on one
or both basic switches
GENERAL INFORMATION
6AS switches are two standard basic
switches ganged together and actuated
by a single actuator. Operating characteristics will depend on the type of individual
switches and actuators.
ELECTRICAL RATING
Electrical Data and
UL Codes
Circuitry
Single-pole
double-throw
unless
otherwise noted
in order guide
A 15 amps, 125, 250 or 480 vac;
1/8 hp, 125 vac; 1/4 hp, 250 vac;
1/2 amp, 125 vdc; 1/4 amp,
250 vdc.
UL Code L96
Single-pole
double-throw
unless
otherwise noted
in order guide
G 20 amps, 125, 250 or 480 vac;
10 amps, 125 vac ‘‘L’’ (tungsten
lamp load);
1 hp, 125 vac; 2 hp, 250 vac;
1/2 amp, 125 vdc; 1/4 amp,
250 vdc.
UL Code L23
Characteristics: O.F. – Operating Force; R.F. – Release Force; P.T. – Pretravel; O.T. – Overtravel; D.T. – Differential Travel; O.P. – Operating Position.
ORDER GUIDE
Catalog
Listing
6AS32
6AS54
6AS25
Dim. Dwg. Fig. 1
Description
Lever
Length
Electrical
mm
Type
Data and
inches Terminals UL Codes
O.F.
max.
newtons
ounces
R.F.
min.
newtons
ounces
O.T.
min.
mm
inches
D.T.
max.
mm
inches
O.P.*
mm
inches
Centered lever. Adjustment over
both switches.
58,72
2.312
Solder
15 Amps
A
2,22
8
0,14
0.5
0,51
.020
2,77
.109
18,29
.720 adj.
Short lever. Adjustment over
switch D.
20,47
.806
Solder
15 Amps
A
3,34
12
0,83
3
0,25
.010
3,96
.156
18,24
.718 max.
Centered lever. Adjustment over
switch D.
32,26
1.270
A2
20 Amps
G
3,89
14
1,11
4
1,02
.040
—
18,67
.735
Unless otherwise noted * ±0,76 mm
±.030 in.
74
Honeywell Sensing and Control
For application help: call 1-800-537-6945.
Basic Switches
Tandem Switch Assemblies
6 AS Series
ORDER GUIDE
Catalog
Listing
6AS13
6AS18
6AS36
6AS35
6AS16
6AS69
6AS112
Dim. Dwg. Fig. 2
6AS5
Dim. Dwg. Fig. 3
Description
Lever
Length
mm
Type
inches Terminals
Electrical
Data and
UL Codes
O.F.
max.
newtons
ounces
R.F.
min.
newtons
ounces
O.T.
min.
mm
inches
D.T.
max.
mm
inches
O.P.*
mm
inches
Centered lever.
Adjustment over
switch D.
30,56
1.203
Solder
15 Amps
A
2,22
8
0,14
0.5
0,51
.020
2,77
.109
29,77
1.172
Centered lever.
Adjustment over both
switches.
30,56
1.203
Solder
15 Amps
A
2,22
8
0,14
0.5
0,51
.020
2,77
.109
29,77
1.172 adj.
Lever over switch C.
Adjustment over
switch D.
30,56
1.203
A2
15 Amps
A
2,22
8
0,14
0.5
0,51
.020
2,77
.109
29,77
1.172
Lever and adjustment
over switch D.
30,56
1.203
A2
15 Amps
A
2,22
8
0,14
0.5
0,51
.020
2,77
.109
29,77
1.172
Centered lever.
Adjustment over
switch D.
30,56
1.203
A2
20 Amps
G
3,89
14
1,11
4
1,02
.040
3,96
.156
30,96±1,14
1.219±.045
Centered lever.
Adjustment over
switch D.
27,25
1.073
T
25 Amps
M
—
—
—
—
30,96±1,14
1.219±.045
Centered lever.
Adjustment over
switch D.
30,56
1.203
A2
25 Amps
H
3,89
14
1,11
4
1,02
.040
3,96
.156
30,96±1,14
1.219±.045
Centered leaf. No
adjustment. Switches
operate within .030 N
of each other.
38,35
1.51
A2
15 Amps
A
—
—
0,76-1,52
.030-.060
—
Unless otherwise noted * ±0,76 mm
±.030 in.
STRAIGHT LEVER
ROLLER LEVER
LEAF
Fig. 1
Fig. 2
Fig. 3
Mounting holes accept pins or screws of
.139 N (3,53 mm) diameter.
For application help: call 1-800-537-6945.
Honeywell Sensing and Control
75
Standard