TI SN74ALS137AN

SN54ALS137A, SN74ALS137A, SN74AS137
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
WITH ADDRESS LATCHES
SDAS203C – APRIL 1982 – REVISED JANUARY 1995
•
•
•
SN54ALS137A . . . J PACKAGE
SN74ALS137A, SN74AS137 . . . D OR N PACKAGE
(TOP VIEW)
Combines Decoder and 3-Bit Address
Latch
Incorporates Two Output Enables to
Simplify Cascading
Package Options Include Plastic SmallOutline (D) Packages, Ceramic Chip
Carriers (FK), and Standard Plastic (N) and
Ceramic (J) 300-mil DIPs
A
B
C
LE
G2
G1
Y7
GND
description
The SN54ALS137A, SN74ALS137A, and
SN74AS137 are 3-line to 8-line decoders/
demultiplexers with latches on the three address
inputs. When the latch-enable (LE) input is low,
the devices act as decoders/demultiplexers.
When LE goes from low to high, the address
present at the select (A, B, and C) inputs is stored
in the latches. Further address changes are
ignored as long as LE remains high. The
output-enable controls (G1 and G2) control the
outputs independently of the select or
latch-enable inputs. All of the outputs are forced
high if G1 is low or G2 is high. These devices are
ideally suited for implementing glitch-free
decoders in strobed (stored-address) applications
in bus-oriented systems.
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
VCC
Y0
Y1
Y2
Y3
Y4
Y5
Y6
B
A
NC
VCC
Y0
SN54ALS137A . . . FK PACKAGE
(TOP VIEW)
4
3 2 1 20 19
18
5
17
6
16
7
15
8
14
9 10 11 12 13
Y1
Y2
NC
Y3
Y4
Y7
GND
NC
Y6
Y5
C
LE
NC
G2
G1
The SN54ALS137A is characterized for operation
over the full military temperature range of – 55°C
to 125°C. The SN74ALS137A and SN74AS137
are characterized for operation from 0°C to 70°C.
NC – No internal connection
FUNCTION TABLE
INPUTS
ENABLE
OUTPUTS
SELECT
LE
G1
G2
C
B
A
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
X
X
H
X
X
X
H
H
H
H
H
H
H
H
X
L
X
X
X
X
H
H
H
H
H
H
H
H
L
H
L
L
L
L
L
H
H
H
H
H
H
H
L
H
L
L
L
H
H
L
H
H
H
H
H
H
L
H
L
L
H
L
H
H
L
H
H
H
H
H
L
H
L
L
H
H
H
H
H
L
H
H
H
H
L
H
L
H
L
L
H
H
H
H
L
H
H
H
L
H
L
H
L
H
H
H
H
H
H
L
H
H
L
H
L
H
H
L
H
H
H
H
H
H
L
H
L
H
L
H
H
H
H
H
H
H
H
H
H
L
H
H
L
X
X
X
Outputs corresponding to stored address = L; all others = H
Copyright  1995, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
SN54ALS137A, SN74ALS137A, SN74AS137
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
WITH ADDRESS LATCHES
SDAS203C – APRIL 1982 – REVISED JANUARY 1995
logic symbols (alternatives)†
4
C8
LE
A
B
C
X/Y
1
8D
2
1
2
3
15
0
4
14
1
13
2
12
3
11
4
G1
6
&
5
5
EN
G2
10
9
6
7
7
4
Y0
Y1
Y2
Y3
LE
A
B
C
C8
2
8D
Y6
15
0
1
0
3
2
14
1
G
Y4
Y5
DMUX
0
7
13
2
12
3
11
4
G1
6
5
G2
Y7
&
10
5
9
6
7
7
Y0
Y1
Y2
Y3
Y4
Y5
Y6
Y7
† These symbols are in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the D, J, and N packages.
logic diagram (positive logic)
A
15
1
14
13
Select
Inputs
B
2
12
Y0
Y1
Y2
Y3
Data
Outputs
11
C
10
9
Latch
Enable
LE
4
7
Output
Enables
G2
G1
5
6
Pin numbers shown are for the D, J, and N packages.
2
Y4
3
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
Y5
Y6
Y7
SN54ALS137A, SN74ALS137A, SN74AS137
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
WITH ADDRESS LATCHES
SDAS203C – APRIL 1982 – REVISED JANUARY 1995
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Operating free-air temperature range, TA: SN54ALS137A . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
SN74ALS137A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54ALS137A
SN74ALS137A
MIN
NOM
MAX
MIN
NOM
MAX
4.5
5
5.5
4.5
5
5.5
UNIT
VCC
VIH
Supply voltage
VIL
IOH
Low-level input voltage
0.7
0.8
High-level output current
– 0.4
– 0.4
mA
IOL
tw
Low-level output current
4
8
mA
Pulse duration, LE low
15
10
ns
tsu
th
Setup time at A, B, and C before LE↑
15
10
ns
TA
Operating free-air temperature
High-level input voltage
2
Hold time at A, B, and C after LE↑
2
5
V
5
– 55
125
V
V
ns
0
70
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
VOH
TEST CONDITIONS
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = – 18 mA
IOH = – 0.4 mA
VOL
5V
VCC = 4
4.5
IOL = 4 mA
IOL = 8 mA
II
IIH
VCC = 5.5 V,
VCC = 5.5 V,
VI = 7 V
VI = 2.7 V
IIL
IO§
VCC = 5.5 V,
VCC = 5.5 V,
VI = 0.4 V
VO = 2.25 V
SN54ALS137A
TYP‡
MAX
MIN
SN74ALS137A
TYP‡
MAX
MIN
– 1.5
VCC – 2
– 1.5
VCC – 2
0.25
0.4
0.1
– 20
UNIT
V
V
0.25
0.4
0.35
0.5
0.1
V
mA
20
20
µA
– 0.1
– 0.1
mA
– 112
mA
– 112
– 30
ICC
VCC = 5.5 V
5
11
5
11
mA
‡ All typical values are at VCC = 5 V, TA = 25°C.
§ The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
SN54ALS137A, SN74ALS137A, SN74AS137
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
WITH ADDRESS LATCHES
SDAS203C – APRIL 1982 – REVISED JANUARY 1995
switching characteristics (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A B
A,
B, C
Y
tPLH
tPHL
G2
Y
tPLH
tPHL
G1
Y
tPLH
tPHL
LE
Y
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 500 Ω,
TA = MIN to MAX†
SN54ALS137A SN74ALS137A
MIN
MAX
MIN
MAX
5
25
5
20
6
25
6
20
4
15
3
12
5
18
4
15
5
21
4
17
5
19
4
15
7
27
6
22
7
25
7
20
UNIT
ns
ns
ns
ns
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Operating free-air temperature range, TA: SN74AS137 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN74AS137
MIN
NOM
MAX
4.5
5
5.5
UNIT
VCC
VIH
Supply voltage
VIL
IOH
Low-level input voltage
0.8
V
High-level output current
–2
mA
IOL
tw
Low-level output current
20
mA
tsu
th
TA
4
High-level input voltage
2
Pulse duration, LE low
V
V
6.5
ns
Setup time at A, B, and C before LE↑
4
ns
Hold time at A, B, and C after LE↑
1
ns
Operating free-air temperature
0
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
70
°C
SN54ALS137A, SN74ALS137A, SN74AS137
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
WITH ADDRESS LATCHES
SDAS203C – APRIL 1982 – REVISED JANUARY 1995
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
SN74AS137
TYP†
MAX
TEST CONDITIONS
MIN
VIK
VOH
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = – 18 mA
IOH = – 2 mA
VOL
II
VCC = 4.5 V,
VCC = 5.5 V,
IOL = 20 mA
VI = 7 V
IIH
IIL
IO‡
VCC = 5.5 V,
VCC = 5.5 V,
VI = 2.7 V
VI = 0.4 V
– 1.2
VCC – 2
UNIT
V
V
0.35
0.5
V
0.1
mA
20
µA
–1
mA
VCC = 5.5 V,
VO = 2.25 V
– 30
– 112
mA
ICC
VCC = 5.5 V
15
24
mA
† All typical values are at VCC = 5 V, TA = 25°C.
‡ The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
switching characteristics (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
RL = 500 Ω,
TA = MIN to MAX§
UNIT
SN74AS137
tPLH
tPHL
A B
A,
B, C
Y
tPLH
tPHL
G2
Y
tPLH
tPHL
G1
Y
tPLH
tPHL
LE
Y
MIN
MAX
2
12.5
2
12.5
2
8
2
8.5
2
10
2
9
3
13.5
3
14
ns
ns
ns
ns
§ For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
SN54ALS137A, SN74ALS137A, SN74AS137
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
WITH ADDRESS LATCHES
SDAS203C – APRIL 1982 – REVISED JANUARY 1995
PARAMETER MEASUREMENT INFORMATION
SERIES 54ALS/74ALS AND 54AS/74AS DEVICES
7V
RL = R1 = R2
VCC
S1
RL
R1
Test
Point
From Output
Under Test
CL
(see Note A)
From Output
Under Test
RL
Test
Point
From Output
Under Test
CL
(see Note A)
CL
(see Note A)
LOAD CIRCUIT FOR
BI-STATE
TOTEM-POLE OUTPUTS
LOAD CIRCUIT
FOR OPEN-COLLECTOR OUTPUTS
3.5 V
Timing
Input
Test
Point
LOAD CIRCUIT
FOR 3-STATE OUTPUTS
3.5 V
High-Level
Pulse
1.3 V
R2
1.3 V
1.3 V
0.3 V
0.3 V
Data
Input
tw
th
tsu
3.5 V
1.3 V
3.5 V
Low-Level
Pulse
1.3 V
0.3 V
1.3 V
0.3 V
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
VOLTAGE WAVEFORMS
PULSE DURATIONS
3.5 V
Output
Control
(low-level
enabling)
1.3 V
1.3 V
0.3 V
tPZL
Waveform 1
S1 Closed
(see Note B)
tPLZ
[3.5 V
1.3 V
tPHZ
tPZH
Waveform 2
S1 Open
(see Note B)
1.3 V
VOL
0.3 V
VOH
1.3 V
0.3 V
[0 V
3.5 V
1.3 V
Input
1.3 V
0.3 V
tPHL
tPLH
VOH
In-Phase
Output
1.3 V
1.3 V
VOL
tPLH
tPHL
VOH
Out-of-Phase
Output
(see Note C)
1.3 V
1.3 V
VOL
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. When measuring propagation delay items of 3-state outputs, switch S1 is open.
D. All input pulses have the following characteristics: PRR ≤ 1 MHz, tr = tf = 2 ns, duty cycle = 50%.
E. The outputs are measured one at a time with one transition per measurement.
Figure 1. Load Circuits and Voltage Waveforms
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
PACKAGE OPTION ADDENDUM
www.ti.com
26-Sep-2005
PACKAGING INFORMATION
Orderable Device
Status (1)
Package
Type
Package
Drawing
Pins Package Eco Plan (2)
Qty
Lead/Ball Finish
MSL Peak Temp (3)
5962-9066501M2A
ACTIVE
LCCC
FK
20
1
TBD
Call TI
Level-NC-NC-NC
5962-9066501MEA
ACTIVE
CDIP
J
16
1
TBD
Call TI
Level-NC-NC-NC
5962-9066501MFA
ACTIVE
CFP
W
16
1
TBD
Call TI
Level-NC-NC-NC
SN74ALS137AD
ACTIVE
SOIC
D
16
40
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
SN74ALS137ADE4
ACTIVE
SOIC
D
16
40
Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
SN74ALS137ADR
ACTIVE
SOIC
D
16
2500 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
SN74ALS137ADRE4
ACTIVE
SOIC
D
16
2500 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
SN74ALS137AN
ACTIVE
PDIP
N
16
25
Pb-Free
(RoHS)
CU NIPDAU
Level-NC-NC-NC
SN74ALS137ANE4
ACTIVE
PDIP
N
16
25
Pb-Free
(RoHS)
CU NIPDAU
Level-NC-NC-NC
SN74ALS137ANSR
ACTIVE
SO
NS
16
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
SN74ALS137ANSRE4
ACTIVE
SO
NS
16
2000 Green (RoHS &
no Sb/Br)
CU NIPDAU
Level-1-260C-UNLIM
SN74AS137D
OBSOLETE
SOIC
D
16
TBD
Call TI
Call TI
SN74AS137DR
OBSOLETE
SOIC
D
16
TBD
Call TI
Call TI
SN74AS137N
OBSOLETE
PDIP
N
16
TBD
Call TI
Call TI
SNJ54ALS137AFK
ACTIVE
LCCC
FK
20
1
TBD
Call TI
Level-NC-NC-NC
SNJ54ALS137AJ
ACTIVE
CDIP
J
16
1
TBD
Call TI
Level-NC-NC-NC
SNJ54ALS137AW
ACTIVE
CFP
W
16
1
TBD
Call TI
Level-NC-NC-NC
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in
a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS) or Green (RoHS & no Sb/Br) - please check
http://www.ti.com/productcontent for the latest availability information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements
for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered
at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame
retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder
temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is
provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the
accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take
reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on
incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited
information may not be available for release.
Addendum-Page 1
PACKAGE OPTION ADDENDUM
www.ti.com
26-Sep-2005
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI
to Customer on an annual basis.
Addendum-Page 2
MECHANICAL DATA
MLCC006B – OCTOBER 1996
FK (S-CQCC-N**)
LEADLESS CERAMIC CHIP CARRIER
28 TERMINAL SHOWN
18
17
16
15
14
13
NO. OF
TERMINALS
**
12
19
11
20
10
A
B
MIN
MAX
MIN
MAX
20
0.342
(8,69)
0.358
(9,09)
0.307
(7,80)
0.358
(9,09)
28
0.442
(11,23)
0.458
(11,63)
0.406
(10,31)
0.458
(11,63)
21
9
22
8
44
0.640
(16,26)
0.660
(16,76)
0.495
(12,58)
0.560
(14,22)
23
7
52
0.739
(18,78)
0.761
(19,32)
0.495
(12,58)
0.560
(14,22)
24
6
68
0.938
(23,83)
0.962
(24,43)
0.850
(21,6)
0.858
(21,8)
84
1.141
(28,99)
1.165
(29,59)
1.047
(26,6)
1.063
(27,0)
B SQ
A SQ
25
5
26
27
28
1
2
3
4
0.080 (2,03)
0.064 (1,63)
0.020 (0,51)
0.010 (0,25)
0.020 (0,51)
0.010 (0,25)
0.055 (1,40)
0.045 (1,14)
0.045 (1,14)
0.035 (0,89)
0.045 (1,14)
0.035 (0,89)
0.028 (0,71)
0.022 (0,54)
0.050 (1,27)
4040140 / D 10/96
NOTES: A.
B.
C.
D.
E.
All linear dimensions are in inches (millimeters).
This drawing is subject to change without notice.
This package can be hermetically sealed with a metal lid.
The terminals are gold plated.
Falls within JEDEC MS-004
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications,
enhancements, improvements, and other changes to its products and services at any time and to discontinue
any product or service without notice. Customers should obtain the latest relevant information before placing
orders and should verify that such information is current and complete. All products are sold subject to TI’s terms
and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are used to the extent TI
deems necessary to support this warranty. Except where mandated by government requirements, testing of all
parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for
their products and applications using TI components. To minimize the risks associated with customer products
and applications, customers should provide adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right,
copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process
in which TI products or services are used. Information published by TI regarding third-party products or services
does not constitute a license from TI to use such products or services or a warranty or endorsement thereof.
Use of such information may require a license from a third party under the patents or other intellectual property
of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of information in TI data books or data sheets is permissible only if reproduction is without
alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction
of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for
such altered documentation.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that
product or service voids all express and any implied warranties for the associated TI product or service and
is an unfair and deceptive business practice. TI is not responsible or liable for any such statements.
Following are URLs where you can obtain information on other Texas Instruments products and application
solutions:
Products
Applications
Amplifiers
amplifier.ti.com
Audio
www.ti.com/audio
Data Converters
dataconverter.ti.com
Automotive
www.ti.com/automotive
DSP
dsp.ti.com
Broadband
www.ti.com/broadband
Interface
interface.ti.com
Digital Control
www.ti.com/digitalcontrol
Logic
logic.ti.com
Military
www.ti.com/military
Power Mgmt
power.ti.com
Optical Networking
www.ti.com/opticalnetwork
Microcontrollers
microcontroller.ti.com
Security
www.ti.com/security
Telephony
www.ti.com/telephony
Video & Imaging
www.ti.com/video
Wireless
www.ti.com/wireless
Mailing Address:
Texas Instruments
Post Office Box 655303 Dallas, Texas 75265
Copyright  2005, Texas Instruments Incorporated