OMRON P6B-Y1

Terminal Relay
G6B-4@@ND
Compact Terminal Relay with 4 Independent
Outputs
• Equipped with four G6B Mini-relays that are compact, highly
sensitive, and highly resistant to dielectric surges, and that can
switch 5 amps of power.
• Sealed plastic construction used for relays.
• Easy wiring with separated input/output terminals.
• Special P6B Mounting Socket used to facilitate maintenance
(except for high-reliability models).
• Standard models meet UL508 and CSA requirements.
• DIN Track mounting, and screw mounting models are available.
Model Number Structure
■ Model Number Legend
G6B-@@@@ND
1 2
3
Note: UL508 and CSA requirements met by standard models.
1. Number of Poles
4:
4 poles (4PST-NO standard circuit)
47: 4 poles (4PST-NO long-life circuit)
48: 4 poles (4PST-NO high-reliability circuit)
2. Mounting
None: DIN Track or screw mounting
F:
Screw mounting
3. Input Terminal
B:
Phillips screw (3.5 mm) terminals (4 independent points)
B1: Flat-bladed screw terminals (4 points with same common)
P:
Connector terminals (4 independent points)
Ordering Information
■ List of Models
Classification
Equipped with operation
indicator and diode to
absorb coil surge
Contact form
Mounting method
Terminals
Rated voltage
Model
4PST (standard)
DIN Track or screw
mounting
Phillips screw terminal
5 VDC
12 VDC
24 VDC
G6B-4BND
4PST (long-life)
DIN Track or screw
mounting
Phillips screw terminal
5 VDC
12 VDC
24 VDC
G6B-47BND
4PST (high reliability)
DIN Track or screw
mounting
Phillips screw terminal
5 VDC
12 VDC
24 VDC
G6B-48BND
4PST (standard)
Screw mounting
Flat-bladed screw
terminal
5 VDC
12 VDC
24 VDC
G6B-4FB1ND
4PST (standard)
Screw mounting
Connector
5 VDC
12 VDC
24 VDC
G6B-4FPND
Note: 1. For replacement relays, use relays with the same voltage specifications as the relays provided with the Terminal when it was purchased.
Longer operating life can be achieved by replacing the G6B-4@@ND with the G6B-1147P-FD-US.
2. Standard models are also available without relays mounted to the sockets. To obtain such terminals, replace the “G6B” portion of the
model number with “P6BF.” For example, to order G6B-4BND with empty sockets, use model number P6BF-4BND. Also specify voltage
specifications for models with operation indicators.
202
Terminal Relay G6B-4@@ND
Specifications
■ Ratings
Coil Ratings (per G6B Relay)
Rated voltage
5 VDC
12 VDC
24 VDC
Rated current
35.5 mA
19.1 mA
10.7 mA
Coil resistance
125 Ω
720 Ω
2,880 Ω
Must operate voltage
80% max. of rated voltage
Must release voltage
10% min. of rated voltage
Max. voltage
130% of rated voltage
Power consumption
Approx. 200 mW
Note: 1. Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of ±20%.
2. Operating characteristics were measured at a coil temperature of 23°C.
3. The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply. There is
no continuous allowance.
4. Diodes to absorb coil surge are equivalent to S5688J (reverse voltage resistance: 600 V; forward current: 1 A).
Contact Ratings
Classification
G6B-4BND (standard), G6B-47BND (long-life)
Load
Resistive load
(cosφ = 1)
Inductive load
Resistive load
(cosφ = 0.4, L/R = 7 ms) (cosφ = 1)
G6B-48BND (high-reliability)
Inductive load
(cosφ = 0.4, L/R = 7 ms)
Rated load
5 A at 250 VAC,
5 A at 30 VDC
2 A at 250 VAC,
2 A at 30 VDC
0.5 A at 250 VAC,
0.5 A at 30 VDC
Rated carry current
5A
Max. switching voltage
380 VAC, 125 VDC
Max. switching current
5A
Max. switching power
1,250 VA, 150 W
2 A at 250 VAC,
2 A at 30 VDC
2A
2A
500 VA, 60 W
Error rate (reference value) (see note) 10 mA at 5 VDC
500 VA, 60 W
125 VA, 15 W
1 mA at 1 VDC
Note: This value fulfills the P reference value of opening/closing at a rate of 120 times per min (ambient operating environment and determination
criteria according to JIS C5442).
■ Characteristics
Contact resistance (see note 2)
100 m Ω max.
Operate time
10 ms max. (approx. 3 ms)
Release time
15 ms max. (approx. 4 ms)
Switching power
Mechanical: 18,000 operations/hr
Rated load: 1,800 operations/hr
Insulation resistance
1,000 MΩ min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
250 VAC, 50/60 Hz for 1 min between coils of different polarity
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 100 m/s2 (approx. 10G)
Endurance
Mechanical: 50,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr, rated load)
500,000 operations min. for long-life at 2 A
100,000 operations min for long-life at 5 A
Ambient temperature
Operating: –25°C to 55°C (with no icing or condensation)
Storage: –25°C to 55°C (with no icing or condensation)
Ambient humidity
Operating: 35% to 85%
Weight
Approx. 75 g
Note: 1. The above values are initial values.
2. Measurement condition: 1 A at 5 VDC
Terminal Relay
G6B-4@@ND
203
Engineering Data
Maximum Switching
Power
Endurance
Contact Reliability
(High-reliability
Models)
AC resistive load
DC inductive load
(L/R = 7 ms)
DC resistive load
G6B-47@ (long life)
250 VAC resistive load
30 VDC resistive load
1,000
G6B-4@ (standard)
250 VAC resistive load
30 VDC resistive load
500
300
100
G6B-4@ (standard)
G6B-47@ (long-life)
250 VAC inductive load (cosφ = 0.4)
30 VDC inductive load (L/R = 7 ms)
G6B-48@ (high-reliability)
250 VAC resistive load
30 VDC resistive load
Switching voltage (V)
204
Terminal Relay G6B-4@@ND
Switching current (A)
Contact resistance (mΩ)
AC inductive load
(cosφ = 0.4)
Endurance (x103 operations)
Switching current (A)
4,000
Number of switching operations
(×104 times)
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Philip Screw Terminals
G6B-4BND
G6B-47BND
G6B-48BND
Note: G6B-4BND is shown in illustration (terminal numbers are incised).
Terminal Arrangement/
Internal Connections
(Top View)
Mounting Holes
16, M3.5 Phillips head screws
Two, 4 dia. holes or
M3.5 screw holes
IN side
Operation
indicator
78 max.
IN side
OUT
side
OUT side
28 max.
(30 max. for
G6B-47@@
long-life model)
43 max.
Note: Do not reverse the coil polarity.
Flat Screw Terminal
G6B-4FB1ND
Five, M2.6
24
max.
43 max.
Mounting Holes
Terminal Arrangement/
Internal Connections
(Top View)
Two, 4 dia. holes or
M3.5 screw holes
IN side
Operation
indicator
61 max.
OUT
side
IN side
Eight, M3.5 Phillips
head screws
OUT side
Note: Do not reverse the coil polarity.
Connector Terminal
G6B-4FPND
24
max.
43 max.
Mounting Holes
IN side
Operation
indicator
Terminal Arrangement/
Internal Connections
(Top View)
Two, 4 dia. holes or
M3.5 screw holes
60 max.
OUT
side
IN side
Eight, M3.5 Phillips
head screws
OUT
side
Note: Do not reverse the coil polarity.
Terminal Relay
G6B-4@@ND
205
■ Accessories (Order Separately)
Replacement Relays
Applicable terminal relay
Rated voltage
Model
G6B-4BND
5 VDC
12 VDC
24 VDC
G6B-1114P-FD-US
G6B-47BND
5 VDC
12 VDC
24 VDC
G6B-1174P-FD-US
Note: Relays cannot be replaced for G6B-48BND, which is mounted directly to boards.
Relay Mounting Products
Name
Model
Relay Removal Tool
P6B-Y1
Short Bars
G6B-4-SB
Mounting Track
PFP-100N
PFP-50N
PFP-100N2
End Plate
PFP-M
Spacer
PFP-S
P6B-Y1 Relay Removal Tool
G6B-4-SB Short Bars
Short Bars are used to wire crossovers for
common terminals for coils or contacts.
G6B-4-C Terminal Covers (Two per set)
206
Terminal Relay G6B-4@@ND
Precautions
Wiring
Relays Mounted
Be sure to turn OFF the power when wiring the Unit and do not touch
the charged terminals of the Unit. Otherwise, an electric shock may
result.
Do not apply overvoltage to the input terminals. Otherwise, the Unit
may malfunction or burn.
G6B-4@@ND standard:
G6B-1114P-FD-US
G6B-4@@ND long life:
G6B-1174P-FD
G6B-4@@ND high reliability: G6B-1184P-US
Replacement is not possible for G6B-48BND.
Wiring
Relay Models
Be sure to connect the input terminals with the correct polarity.
Do not connect the Unit to loads exceeding the rated switching power
(switching voltage or current). Otherwise, faulty insulation, contact
weld, or faulty contact of Relays, or damage to Relays may result, or
the Relays may malfunction or burn.
The life of Relays varies with the switching condition. Test the Relays
under the actual operating conditions before using the Relays within
the permissible switching frequency. The use of deteriorated Relays
may result in the faulty insulation of the Relays or cause the Relays
to burn.
Do not use the Unit in locations with inflammable gas. Otherwise, a
fire or explosion due to the heat of the Relays or sparks from the
Relays may result when they are switched.
Coil Voltage
Be sure not to impose voltage exceeding the permissible voltage on
the coil continuously.
Do not use the relays when other inductive loads are connected in
parallel with the coil input or when there are surges during power
supply because the built-in diodes used to absorb surge may be
destroyed.
Do Not Use the Following Circuit
■ Correct Use
Inductive load
Mounting
Heat generated by the relays must be considered when gang-mounting. Space must be provided between the relays or other methods
must be taken to maintain the relays’ ambient temperature at 55 °C
or lower.
Replacement of Relays
G6B-4@@ND
Use the P6B-Y1 Removal Tool as shown in the following diagram.
G6B Coil
Coil surge current
absorption diode
Handling
Do not drop, shock, or vibrate the Unit excessively. Otherwise, damage to the Unit may result or the Unit may malfunction.
Make sure that all the Relays are properly mounted before use.
Screw Tightening Torque
Tighten each terminal screw to a torque of 0.78 to 1.18N·m.
Tighten each mounting screw to a torque of 0.59 to 0.98 N·m.
Installation Environment
Be sure to turn OFF the power to the Unit before replacing a Relay.
Relays must be inserted straight onto the socket connector pins to
ensure proper connection.
G6B-48BND models (high reliability) are connected directly to
boards to increase reliability and the relays are thus not replaceable.
If relay replacement is necessary, use the P6BF-4BND Terminal
Sockets together with the G6B-1184P Mini Relays. P6BF-4BND Terminal Sockets are equipped with relay replacement sockets.
Do not mount Relays that are different to one another in voltage.
Do not install the Unit in the following locations. Otherwise, damage
to the Unit may result or the Unit may malfunction.
Locations with direct sunlight.
Locations with an ambient temperature range not within 0°C to 55°C.
Locations with rapid temperature changes resulting in condensation
or locations with relative humidity ranges not within 10% to 90%.
Locations with corrosive or inflammable gas.
Locations with excessive dust, salinity, or metal powder.
Locations with vibration or shock affecting the Unit.
Locations with water, oil, or chemical sprayed on the Unit.
Disassembly, Repair, and Modification
Do not disassemble, repair, or modify the Unit. Otherwise, an electric
shock may result or the Unit may malfunction.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. J098-E1-02A
In the interest of product improvement, specifications are subject to change without notice.
Terminal Relay
G6B-4@@ND
207