OMRON V700-CD2D-V3

Electromagnetic Inductive RFID System
V700
A High-functionality High-performance RFID
System That Revolutionizes Product and
Distribution Management in the Production
Environment
• A long transmission distance and a wide transmission range allow position displacement and axial offset of ID Tags to be handled with ease.
• Reading and writing are possible with several ID Tags in the Antenna’s transmission range, allowing use in new applications.
• Easy-to-use, reasonably-priced ID Tags enable the creation of low-cost systems even in applications using a
large number of Tags.
• Availability of price effective Compact Reader V700HMD11(-1)
• The lineup includes an ID Link Unit that is compatible
with multi-drop connections and RS-485 interfaces.
• The V700-HMD11-1 Compact Reader Writer can be connected
directly to the ID Link Unit or an OMRON PLC without an AC
Adapter.
• CE marking.
• FCC approvals and R&TTE Directive compliance.
Ordering Information
■ List of Models
Name
Model
Specifications/Design
V700-D23P31
20 dia. × t 2.7 mm
Coin-shaped
256 bytes (with user area of 240 bytes)
V700-D23P41
3.9 dia. × 25 mm
Stick-shaped
256 bytes (with user area of 240 bytes)
V700-D23P61
40 × 40 × 4.5 mm
Square tag
256 bytes (with user area of 240 bytes)
ID Tag Holder
V700-A80
Special holder for the V700-D23P31
(There is no ID Tag provided with the product.)
Antenna
V700-H01
(Standard Antenna)
250 × 200 × 35 mm 100-mm cable
ID Tag
Electromagnetic Inductive RFID System
V700
1
Name
Model
Controller
V700-CD1D-V3
Specifications/Design
90 × 65 × 75 mm
V700-CD2D-V3
Antenna Cable
RS-485 interface
Maximum number of Controllers that
can be connected: 31
24 VDC, 1 channel for Antenna
connection
V700-A40
2m
V700-A41
3m
V700-A42
5m
V700-A43
10 m
V700-A44
20 m
V700-A45
30 m
Compact Reader V700-HMD11
Writer
40 × 53 × 23 mm
V700-HMD11-1
ID Link Unit
V700-L12
Programming
Console
C200H-PRO27-E
Programming
Console
Connecting
Cable
V700-P10
2
Electromagnetic Inductive RFID System V700
RS-232C interface
24 VDC, 1 channel for Antenna
connection
Material: Vinyl chloride
The connector is not waterproof.
RS-232C interface
5 VDC supplied via AC Adapter
2-m cable
RS-232C interface 1-m cable
5 VDC supplied
2-m cable
from connector
4-m cable
110 × 65 × 64 mm
RS-232C and RS-485 interface
Unit for multiple connections
Equipped with the following functions:
Execution status monitor, set value
display, transmission execution,
transmission test, noise measurement,
reading error contents
2m
Cable for connecting the V700-CD@DV@ and C200H-PRO27-E
Specifications
■ ID Tags
Model
V700-D23P61
V700-D23P31
V700-D23P41
Memory capacity
240 bytes (user area)
240 bytes (user area)
240 bytes (user area)
Memory type
EEPROM
Data backup time
10 years after data written
Data writing times
100,000 times per address
Ambient operating
temperature (during
transmission)
−20 to 70°C (with no icing)
−25 to 70°C (with no icing)
−10 to 70°C
−40 to 110°C (with no icing)
−10 to 70°C (with no icing)
Item
Ambient operating
−40 to 110°C (with no icing)
temperature (not during
Heat resistance:
transmission)
Constant high temperature:
180°C for 200 hours
Thermal cycle: 25°C/180°C, 30
minutes, 200 cycles
Ambient storage
temperature
−40 to 110°C (with no icing)
−40 to 110°C (with no icing)
−10 to 70°C (with no icing)
Ambient operating
humidity
No restrictions
35% to 95% (with no condensation)
35% to 85%
Degree of protection
IEC 60529: IP68
IEC 60529: IP67
IP67 (IEC 60529 standard)
Vibration resistance
10 to 2,000 Hz, 0.75-mm single amplitude, 150-m/s2 acceleration with 10
sweeps of 15 min each in X, Y, and Z directions
10 to 2,000 Hz, 1.5-mm single amplitude, 150-m/s2 acceleration with 10
sweeps of 15 min each in X, Y, and Z
directions
Shock resistance
500-m/s2 acceleration for 3 times each in X, Y, and Z directions (18 times in
total)
500-m/s2 acceleration for 3 times each
in 6 directions, front/back, up/down,
and left/right (18 times in total)
Material
PPS resin
Case: PBT resin; Filling: Epoxy resin Case: ABS; Filling: Epoxy resin
Weight
Approx. 2 g
Approx. 1 g
Approx. 6 g
■ Controllers
Model
V700-CD1D-V3
V700-CD2D-V3
Item
Host interface
RS-232C
Number of connectable
Antennas
1
RS-485 (Up to 31 Controllers can be connected.)
Power supply voltage
24 VDC +10%/−15%
Power consumption
20 W max.
Insulation resistance
20 MΩ min. (at 100 VDC) between the power supply terminals and ground terminal, power supply terminals and I/O
terminals, power supply terminals and case, I/O terminals and ground terminal, I/O terminals and case, and ground
terminal and case
Dielectric strength
500 VAC (50/60 Hz, 1 minute) between the above terminals (leakage current: 10 mA max.)
Vibration resistance
10 to 150 Hz, 0.30-mm double amplitude with 4 sweeps of 8 min each in X, Y, and Z directions
Shock resistance
200-m/s2 acceleration for 3 times each in X, Y, and Z directions (18 times in total)
Ambient operating
temperature
−10 to 55°C (with no icing)
Ambient operating
humidity
35% to 85% (with no condensation)
Electromagnetic Inductive RFID System
V700
3
Model
V700-CD1D-V3
V700-CD2D-V3
Item
Ambient storage
temperature
−25 to 65°C (with no icing)
Ambient storage
humidity
35% to 95% (with no condensation)
Degree of protection
IEC 60529: IP30 (panel mounted)
Ground
Ground at a resistance of less than 100 Ω. If grounding is not performed properly, transmission specifications may be
adversely affected by the surrounding environment.
Weight
Approx. 290 g
■ Antennas
Model
V700-H01
Item
Oscillation frequency
125 kHz
Insulation resistance
20 MΩ min. (at 500 VDC) between the cable terminals and the case
Dielectric strength
1,000 VAC (50/60 Hz, 1 minute) between the cable terminals and the case (leakage current: 1 mA max.)
Vibration resistance
10 to 150 Hz, 1.50-mm double amplitude with 2 sweeps of 8 min each in X, Y, and Z directions
Shock resistance
300-m/s2 acceleration for 3 times each in X, Y, and Z directions (18 times in total)
Ambient operating
temperature
−20 to 55°C (with no icing)
Ambient storage
temperature
−35 to 65°C (with no icing)
Ambient operating
humidity
35% to 85% (with no condensation)
Ambient storage
humidity
35% to 95% (with no condensation)
Degree of protection
IEC 60529: IP40 (except connector)
Material
Case: PC/ASA resin; Rear panel: Phenol resin; PVC (The connector is not resistant to water or oil.)
Cable length
Maximum connection distance: 50.1 m using extension cable.
Weight
Approx. 800 g
4
Electromagnetic Inductive RFID System V700
■ Compact Reader Writers
Model
V700-HMD11-1
V700-HDM11
Item
Host interface
RS-232C
Power consumption
5 VDC ±5%
Oscillating: 200 mA max.; Not oscillating: 25 mA max.
Insulation resistance
50 MΩ min. (at 500 VDC) between the cable terminals and the case
Dielectric strength
1,000 VAC (50/60 Hz, 1 minute) between the cable terminals and the case (leakage current: 1 mA max.)
Vibration resistance
10 to 150 Hz, 1.50-mm double amplitude with 4 sweeps of 8 min each in X, Y, and Z directions
Shock resistance
300-m/s2 acceleration for 3 times each in X, Y, and Z directions (18 times in total)
Ambient operating
temperature
−10 to 55°C (with no icing)
Ambient operating
humidity
25% to 85% (with no condensation)
Ambient storage
temperature
−25 to 65°C (with no icing)
Ambient storage
humidity
25% to 95% (with no condensation)
Degree of protection
IEC 60529: IP67
The connector is not resistant to water or oil.
Material
Case: ABS resin; Filling: Epoxy resin; Cable: PVC (oil-resistant)
Cable length
2 m (RS-232C signal lines can be extended up to a total 1, 2, 4 m
length of 15 m.)
Weight
Approx. 210 g
5 VDC ±5% (supplied via connector)
250 mA max.
Approx. 210 g (2 m)
Electromagnetic Inductive RFID System
V700
5
■ ID Link Unit
Item
V700-L12
Host interface
RS-232C or RS-485 (special 1:N protocol)
Number of connectable
Antennas
1
Power supply voltage
24 VDC +10%/−15%
Power consumption
10 W max.
Insulation resistance
50 MΩ min. (at 500 VDC) between the power supply terminals and the ground terminal
Dielectric strength
1,000 VAC (50/60 Hz, 1 minute) between the power supply terminals and the ground terminal (leakage current: 5 mA
max.)
Vibration resistance
10 to 150 Hz, 0.20-mm double amplitude, 15-m/s2 acceleration with 10 sweeps of 8 min each in X, Y, and Z directions
Shock resistance
150-m/s2 acceleration for 3 times each in X, Y, and Z directions (18 times in total)
Ambient operating
temperature
0 to 40°C (with no icing)
Ambient operating
humidity
35% to 85% (with no condensation)
Ambient storage
temperature
−15 to 50°C (with no icing)
Ambient storage
humidity
35% to 85% (with no condensation)
Degree of protection
IEC 60529: IP20
Ground
Ground at a resistance of less than 100 Ω. If grounding is not performed properly, transmission specifications may be
adversely affected by the surrounding environment.
Weight
Approx. 185 g
■ ID Tag Holder (for V700-D23P31
Coin-shaped ID Tag)
Item
V700-A80
Ambient storage
temperature
Conforms to the specifications for the
V700-D23P31 Coin-shaped ID Tag.
Ambient operating
humidity
No restrictions
Material
PPS resin
Weight
Approx. 5 g
6
Electromagnetic Inductive RFID System V700
System Configuration
Programming Console
ID Tag
Antenna
Antenna Cable
Controller
C200H-PRO27-E
V700-CD2D-V3
RS-485 interface
V700-A40
-A41
-A42
-A43
-A44
-A45
V700-D23P31
Host device
with RS-485
interface
Programming Console Conversion Cable
V700-P10
Holder for
V700-D23P31
V700-CD1D-V3
RS-232C interface
V700-H01
V700-A80
Compact Reader Writer (Combined Antenna and Controller)
Host device
with RS-232C
interface
V700-HMD11
V700-D23P41
V700-HMD11-1
ID Link Unit
V700-D23P61
V700-L12
Programmable
Controller
CPM2C Series
Note: The V700-CD1D-V3, V700-HMD11(-1), and V700-L12 all have different function
and command structures.
Electromagnetic Inductive RFID System
V700
7
Functions
■ Transmission Functions
V700-CD1D-V3
V700-CD2D-V3
V700-HMD11
V700-HMD11-1
Single access
Provided
Provided
FIFO
Provided
Provided
Multiple access
Provided
Not provided
Selective access
Provided
Not provided
Note: The V700-CD@D-V@ and V700-HMD11(-1) have different
command structures.
■ Transmission Time (Reference)
The transmission time is the time required for transmission between the Antenna and ID Tag and does not include time required for host communications.
V700-CD@D-V@
Asynchronous
Read-only
synchronization
Read-write
synchronization
Write
T = 52.8 N + 113.5
Read
T = 46.7 N + 60.7
Read
T = 46.7 N + 107.4
Write
T = 52.8 N + 172.4
Read
T = 52.8 N + 119.6
V700-HMD11/HMD11-1
Precautions on Using the Product near Noise Sources
This product makes transmissions to ID Tags using a frequency of 125 kHz. Transceivers, motors, monitoring devices, and power supplies have parts that generate
electromagnetic waves (noise). These waves may interfere
with transmissions to ID Tags. Before using this product near
these kinds of devices, check that there is no adverse affect
on transmissions.
Multiple Access with the V700-CD@D-V@
Read
T = 48 N + 66
Write
T = 55 N + 120
The transmission time when using multiple-access commands not
only depends on the number of bytes, but also on the number of ID
Tags in the transmission range and the combination of the ID Tags’
codes. The average values for random ID codes are given below.
(units: ms)
Note: T = Transmission time (ms)
N = Number of pages (1 page = 8 bytes)
Number of Tags
Reading 8 bytes
5
579
Writing 8 bytes
873
10
1,191
1,547
15
1,857
2,275
20
2,523
3,002
30
3,853
4,455
50
6,344
7,192
■ Mutual Interference Prevention Functions (Using the V700-CD@D-V@)
If there is less than 15 m between Antennas, all the Antennas must be synchronized to prevent mutual interference. This can be done using either
of the two methods described below.
Read-only Synchronization
Read/Write Synchronization
If all the Antennas only use read commands, this method can be
used to reduce the access time.
This is the synchronization method that is usually used. It enables
the synchronization of both read and write commands for several
connected Antennas.
ID Controllers Antennas
ID Controllers Antennas
1 m min.
Read
8
Read
1 m min.
Read
1 m min.
Read
1 m min.
Read
Electromagnetic Inductive RFID System V700
1 m min.
Read
Read
1 m min.
Write
1 m min.
1 m min.
Read/Write
Read
Characteristic Data (Typical)
■ Transmission Range
Antenna Operation Range Graphs
V700-H01 & V700-D23P31
V700-CH1D & V700-D23P61
Y
Y
X
V700-CH1D (-1)
40
30
X
Y
20
30
V700-H01
Tag
Y
20
Tag
10
–40
–30
–20
–10
10
0
10
20
30
40
X
cm
−40
−30
−20
−10
0
10
20
30
40
X
mm
V700-HMD11(-1) & V700-D23P31
Y
V700-HMD11(-1)
50
X
40
Y
Tag
30
20
10
–50
–40
–30
–20
–10
0
10
20
30
40
50
X
mm
V700-H01 & V700-D23P41
Y
X
30
Y
V700-H01
Tag
20
10
–40
–30
–20
–10
0
10
20
30
40
X
cm
V700-HMD11(-1) & V700-D23P41
Y
V700-HMD11(-1)
50
X
40
Y
Tag
30
20
10
–50
–40
–30
–20
–10
0
10
20
30
40
50
X
mm
V700-HMD11 & V700-D23P61
Y
V700-HMD11
X
80
60
Y
Tag
40
20
−80
−60
−40
−20
0
20
40
60
80
X
mm
Electromagnetic Inductive RFID System
V700
9
Dimensions
Note: All units are in millimeters unless otherwise indicated.
ID Tag
ID Tag Holder (for V700-D23P31)
V700-D23P31
Coin-shaped ID Tag
V700-D23P41
Stick-shaped ID Tag
V700-A80
40
20 dia.+0.05
Two, 6-dia.
22
Two, 3.5-dia.
31±0.1
25±0.1
3.9 dia.±0.1
3.5
1.5
R1
1.1 2.7 dia.±0.1
5 8
R0.25
16 dia.
20 dia.
1
0.2
V700-D23P61
Square Tags
22
8
Mounting Hole Dimensions
5.2
8
13.2
Two, M3
5.2
8
13.2
16
40㧗0.1
−0.5
32±0.2
0.2
16
Mounting reference
surface
8
Two, 3.5 dia.
mounting holes
16
16
40㧗0.1
−0.5
2
4.5
Antenna
V700-H01 Standard Antenna
200
185±0.2
Four, 5-dia.
85
142.5
235±0.2
250
40
13.5
78.8
21
20 max.
7.5
30
100
44.5
16 max.
10
Electromagnetic Inductive RFID System V700
32±0.2
Case: ABS
Filling: Epoxy resin
Compact Reader Writer
V700-HMD11
Two, 10-dia.
Two, 4.5-dia. mounting holes
6 dia., length: 2 m
Bushing
5
32
28
40
10
Four, R1
5
27
53
20
11 dia
Operation indicator
6
Length: 190
34
45.5
5
13
18
11
15
23
.
Connector:EIAJRC5320AJSAP2(receptacle)
V700-HMD11-1
6 dia., length: 1 m, 2 m, 4 m
Bushing
32
40
5
Two, 4.5-dia. mounting holes
10
Two, 10-dia.
28±0.1
Four, R1
45.5
5
27
Operation indicator
13
18
20
11
15
23
53
5
6
Controller
V700-CD1D-V3
10
66
75
8
4
10
Power
indicator
4
4
4
Operation
indicator
21
18
90 100
17.5
10
10
56
Two, 4.5-dia. mounting holes
V700-CD2D-V3
10
10
66
75
8
4
Power
indicator
4
4
4
Operation
indicator
21
18
90 100
17.5
10
56
10
Two, 4.5-dia. mounting holes
Electromagnetic Inductive RFID System
V700
11
ID Link Unit
V700-L12
110
41.5
26.5
41.3
18.5 20.3
65
16.7 10.7
35.2
5
Two, 4.5-dia.
4
4
Mounting Hole Dimensions
55±0.2
Two, M4 or 4.2-dia.
110±0.2
12
Electromagnetic Inductive RFID System V700
60
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of
sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS
FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT
THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S
ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO
CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate
catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use
of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This
information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other
application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the
products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment,
and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A
WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED
USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of
OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of
Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some
specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your
application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or
proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in
any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.
16
Electromagnetic Inductive RFID System V700
Cat. No. Q111-E2-04
OMRON Corporation
2007. 3
In the interest of product improvement, specifications are subject to change without notice.
Industrial Automation Company