HONEYWELL 702-101BBB-A00

DESCRIPTION
The 700 Series has 100
and 1000
base resistances and is
The 700 Series Platinum RTD (Resistance Temperature
available in both the 3750 ppm/K and 3850 ppm/K temperature
Detector) is an economical, miniature temperature sensor. The
coefficients (375 and 385 alphas). The tolerances of the 700
series is available in two different package configurations,
Series meet DIN class A, DIN class B and DIN class 2B
leaded and SMT (Surface Mount Technology). Two sizes are
industry-standards.
available for each configuration, with the SMT available in
industry standard 0805 and 1206 packages.
The 700 Series is RoHS (Restriction of Hazardous
Substances) compliant (EU Directive 2002/95/EC).
FEATURES
POTENTIAL APPLICATIONS
Linear resistance vs temperature
HVAC (Heating Ventilation and Air Conditioning)
High accuracy
Electronic assemblies
Interchangeable
Process control
Excellent stability
Appliances
Fast time response
Automotive
Wide temperature range
Instrumentation
RoHS compliant
Table 1. Specifications
Temperature
range
Leads
Long-term
stability
Vibration
resistance
Shock
resistance
Environmental
conditions
Insulation
resistance
Self heating
Response time
Measuring current
Packaging
Temperature
range
Soldering
connection
Long-term
stability
Environmental
conditions
Insulation
resistance
Self heating
Response time
Measuring current
Processing
instructions
Packaging
2
700-*
Class B and 2B: -70 °C to 500 °C (continuous
operation)
Class A: -30 °C to 300 °C
701-*
Class B and 2B: -70 °C to 500 °C (continuous
operation)
Class A: -30 °C to 300 °C
Pt-clad Ni wire
max. R0 drift 0.04% after 1000 h at 500 °C
Pt-clad Ni wire
max. R0 drift 0.04% after 1000 h at 500 °C
at least 40 g acceleration at 10 Hz to 2000 Hz,
depends on installation
at least 100 g acceleration with 8 ms half sine
wave, depends on installation
unhoused for dry environments only
at least 40 g acceleration at 10 Hz to 2000 Hz,
depends on installation
at least 100 g acceleration with 8 ms half sine
wave, depends on installation
unhoused for dry environments only
>100 M
>100 M
at 20 °C; >2 M
at 500 °C
at 20 °C; >2 M
at 500 °C
0.4 K/mW at 0 °C
water current (v=0.4 m/s): t0.5=0.05 s; t0.9=0.15 s
air stream (V=2 m/s): t0.5=3.0 s; t0.9=10.0 s
100 : 0.3 mA to 1.0 mA
1000 : 0.1 mA to 0.3 mA
anti-static plastic bag
0.6 K/mW at 0 °C
water current (v=0.4 m/s): t0.5=0.04 s; t0.9=0.12 s
air stream (V=2 m/s): t0.5=2.2 s; t0.9=7.0 s
100 : 0.3 mA to 1.0 mA
1000 : 0.1 mA to 0.3 mA
anti-static plastic bag
702-*
Class B: -50 °C to 130 °C (continuous operation)
703-*
Class B: -50 °C to 130 °C (continuous operation)
end-termination galvanic tin-plated with Ni barrier
layer
max. R0 drift 0.06 % after 1000 h at 130 °C
end-termination galvanic tin-plated with Ni barrier
layer
max. R0 drift 0.06 % after 1000 h at 130 °C
unhoused for dry environments only
unhoused for dry environments only
>100 M at 20 °C; >2 M
covering)
0.8 K/mW at 0 °C
>100 M at 20 °C; >2 M
covering)
0.4 K/mW at 0 °C
at 130 °C (glass
water current (v=0.4 m/s): t0.5=0.10 s; t0.9=0.25 s
air stream (V = 2 m/s): t0.5=2.5 s; t0.9=8.0 s
100 : 0.3 mA to 1.0 mA
1000 : 0.1 mA to 0.3 mA
face up mounting: reflow soldering or wave
soldering, e.g. double wave ≤8 s/235 °C
face-up in blister reel
www.honeywell.com/sensing
at 130 °C (glass
water current (v=0.4 m/s): t0.5=0.15 s; t0.9=0.30 s
air stream (V = 2 m/s): t0.5=3.5 s; t0.9=10.0 s
100 : 0.3 mA to 1.0 mA
1000 : 0.1 mA to 0.3 mA
face up mounting: reflow soldering or wave
soldering, e.g. double wave ≤8 s/235 °C
face-up in blister reel
Figure 1. Mounting Dimensions (For reference only mm/[in].)
700-*
701-*
1,7 ±0,25
[0.067 ±0.01]
2,3 ±0,15
[0.091 ±0.0059]
A
8 ±1
[0.315 ±0.0394]
B
10 ±1
[0.394 ±0.0394]
10 ±1
[0.394 ±0.0394]
Ø 0,15 ±0,02
[0.006 ±0.001]
Ø 0,2 ±0,02
[0.008 ±0.0008]
1,25 ±0,15
[0.049 ±0.006]
2,1 ±0,2
[0.083 ±0.0079]
0,8. ±0,2
[0.031 ±0.008]
0,9 +0,3
-0,2
[0.035
A
B
+0.0118]
-0.0079]
Applies to the following 700-* listings only:
700-102AAB-B00
700-102AAC-B00
Applies to all other 700-* listings.
702-*
703-*
0,52 ±0,05
[0.020 ±0.0020]
0,6 ±0,05
[0.024 ±0.0020]
0,5 ±0,2
[0.020 ±0.0079]
0,35 ±0,2
[0.014 ±0.0079]
2,3 ±0,15
[0.091 ±0.0059]
3,25 ±0,15
[0.128 ±0.0059]
0,35 ±0,2
[0.014 ±0.0079]
0,5 ±0,2
[0.020 ±0.0079]
1,4 ±0,15
[0.055 ±0.0059]
1,65 ±0,15
[0.065 ±0.0059]
Honeywell Sensing and Control
3
Order Guide
Catalog Listing
700-101BAA-B00
700-101BAB-B00
700-102AAB-B00
700-102AAC-B00
700-102BAA-B00
700-102BAB-B00
701-101BAA-B00
701-101BAB-B00
701-102AAB-B00
701-102BAB-B00
702-101BBB-A00
702-102BBB-A00
703-101BBB-A00
703-102BBB-A00
Package Style and Size
mm [in]
chip, 2,1 w x 2,3 l x 0,9 thk
[0.083 w x 0.091 l x 0.035 thk]
chip, 2,1 w x 2,3 l x 0,9 thk
[0.083 w x 0.091 l x 0.035 thk]
chip, 2,1 w x 2,3 l x 0,9 thk
[0.083 w x 0.091 l x 0.035 thk]
chip, 2,1 w x 2,3 l x 0,9 thk
[0.083 w x 0.091 l x 0.035 thk]
chip, 2,1 w x 2,3 l x 0,9 thk
[0.083 w x 0.091 l x 0.035 thk]
chip, 2,1 w x 2,3 l x 0,9 thk
[0.083 w x 0.091 l x 0.035 thk]
chip, 1,25 w x 1,7 l x 0,8 thk
[0.049 w x 0.067 l x 0.031 thk]
chip, 1,25 w x 1,7 l x 0,8 thk
[0.049 w x 0.067 l x 0.031 thk]
chip, 1,25 w x 1,7 l x 0,8 thk
[0.049 w x 0.067 l x 0.031 thk]
chip, 1,25 w x 1,7 l x 0,8 thk
[0.049 w x 0.067 l x 0.031 thk]
SMD 0805, 1,4 w x 2,3 l x 0,52 thk
[0.055 w x 0.091 l x 0.020]
SMD 0805, 1,4 w x 2,3 l x 0,52 thk
[0.055 w x 0.091 l x 0.020]
SMD 1206, 1,65 w x 3,25 l x 0,6 thk
[0.065 w x 0.128 l x 0.024]
SMD 1206, 1,65 w x 3,25 l x 0,6 thk
[0.065 w x 0.128 l x 0.024]
Nominal
Temp.
Temp.
Tolerance
Resistance Coefficient
Range
at 0 °C
(°C)
3850 ppm/K -70 to 500 DIN EN 60751, class A
100
(R0: ±0.06 %)
3850 ppm/K -70 to 500 DIN EN 60751, class B
100
(R0: ±0.12 %)
3750 ppm/K -70 to 500 DIN EN 60751, class B
1000
(R0: ±0.12 %)
3750 ppm/K -70 to 500 DIN EN 60751, class 2B
1000
(R0: ±0.24 %)
3850 ppm/K -70 to 500 DIN EN 60751, class A
1000
(R0: ±0.06 %)
3850 ppm/K -70 to 500 DIN EN 60751, class B
1000
(R0: ±0.12 %)
3850 ppm/K -70 to 500 DIN EN 60751, class A
100
(R0: ±0.06 %)
3850 ppm/K -70 to 500 DIN EN 60751, class B
100
(R0: ±0.12 %)
3750 ppm/K -70 to 500 DIN EN 60751, class B
1000
(R0: ±0.12 %)
3850 ppm/K -70 to 500 DIN EN 60751, class B
1000
(R0: ±0.12 %)
3850 ppm/K -50 to 130 DIN EN 60751, class B
100
(R0: ±0.12 %)
3850 ppm/K -50 to 130 DIN EN 60751, class B
1000
(R0: ±0.12 %)
3850 ppm/K -50 to 130 DIN EN 60751, class B
100
(R0: ±0.12 %)
3850 ppm/K -50 to 130 DIN EN 60751, class B
1000
(R0: ±0.12 %)
WARNING
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective
materials and faulty workmanship. Honeywell’s standard product
warranty applies unless agreed to otherwise by Honeywell in writing;
please refer to your order acknowledgement or consult your local sales
office for specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair or
replace, at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no event
shall Honeywell be liable for consequential, special, or indirect
damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specifications may change without notice. The information we supply
is believed to be accurate and reliable as of this printing. However, we
assume no responsibility for its use.
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for reference
only. Do not use this document as a product installation guide.
Complete installation, operation, and maintenance information is
provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death
or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network of sales
offices, representatives and distributors. For application assistance,
current specifications, pricing or name of the nearest Authorized
Distributor, contact your local sales office or:
E-mail: [email protected]
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific
+65 6355-2828
+65 6445-3033 Fax
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Sensing and Control
Honeywell
1985 Douglas Drive North
www.honeywell.com/sensing
bare Pt-clad Ni wire, adjacent
leads
bare Pt-clad Ni wire, adjacent
leads
bare Pt-clad Ni wire, adjacent
leads
bare Pt-clad Ni wire, adjacent
leads
bare Pt-clad Ni wire, adjacent
leads
bare Pt-clad Ni wire, adjacent
leads
bare Pt-clad Ni wire, adjacent
leads
bare Pt-clad Ni wire, adjacent
leads
bare Pt-clad Ni wire, adjacent
leads
bare Pt-clad Ni wire, adjacent
leads
end termination, galvanic Snplated with Ni barrier layer
end termination, galvanic Snplated with Ni barrier layer
end termination, galvanic Snplated with Ni barrier layer
end termination, galvanic Snplated with Ni barrier layer
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices
or in any other application where failure of the product could result in
personal injury.
Failure to comply with these instructions could result in death
or serious injury.
Minneapolis, MN 55422
Termination
009018-3-EN IL50 GLO Printed in USA
April 2010
© 2010 Honeywell International Inc. All rights reserved.