ETC 32.208.779

Platinum Resistance Temperature Detector
HL 220
HL 220 type platinum sensors are characterised by long-term stability, precision over a broad temperature range and
compatibility. The main feature is the small design. They are used in particular for applications with high consumption
volumes, e.g. white goods and heating power.
Nominal
Resistance R0
Tolerance
DIN EN 60751
1996-07
Tolerance
DIN EN 60751
2009-05
Order Number
Plastic Box
1000 Ohm at 0°C
Class 2B
F 0.6
32 208 779
The measuring point fort he nominal resistance is defined at 6mm from the end oft he sensor body.
Specification
DIN EN 60751
Temperature range
-70°C up to +750°C
Tolerance Class 2B: -70°C up to +750°C
Temperature coefficient
TC = 3850 ppm/K
Leads
Pt coated NiCr- wire
Lead lengths (L)
8mm ±1mm
Long-term tests
R0- Drift after 1000h at 750°C (energized) < 0,24%
(Unhoused chip in standard atmosphere.)
Environmental conditions
Unhoused for dry environmental only, above 500°C
no reducing atmosphere, free air admission is
necessary.
Assembly can influence the long term stability!
Vibration resistance
at least 40g acceleration at 10 to 2000 Hz,
depends on installation
Shock resistance
at least 100g acceleration with 8ms half sine wave,
depends on installation
Insulation resistance
> 100 M at 20 °C; > 1 M at 650 °C
Self heating
0.2 K/mW
Response time
Water current (v= 0.4m/s):
Air stream (v= 2m/s):
t0.5 = 0.05s
t0.9 = 0.14s
t0.5 = 3.0s
t0.9 = 10s
Measuring current
0.1 to 1mA
(self heating has to be considered)
Note
Other tolerances, values of resistance and wire lengths are
available on request.
We reserve the right to make alterations and technical data printed. All technical data serves as a guideline and does not guarantee
particular properties to any products.
Heraeus Sensor Technology USA
1901 Route 130
North Brunswick, NJ 08902
Phone 732-940-4400
Fax 732-940-4445
Email [email protected]
http://heraeus-sensor-technology-us.com
Name of document: 30910055 Index C
Status: 06/2010