MICRODC WRE4805ZD-3W

WRE-ZD-3W&WRF-ZD-3W Series
3W,4:1 WIDE INPUT,ISOLATED&REGULATED SINGLE/DUAL OUTPUT DIP DC/DC CONVERTER
SELECTION GUIDE
Input
Output
Voltage(VDC)
Order code
Efficiency
(%,Typ)
Current(mA)
Nominal
Range
Max.*
Voltage
(VDC)
WRE2405ZD-3W
24
9-36
40
±5
±300
±30
80
WRE2412ZD-3W
24
9-36
40
±12
±125
±13
82
WRE2415ZD-3W
24
9-36
40
±15
±100
±10
84
WRE2424ZD-3W
24
9-36
40
±24
±63
±6
87
WRF2403ZD-3W
24
9-36
40
3.3
909
91
78
WRF2405ZD-3W
24
9-36
40
5
600
60
80
WRF2412ZD-3W
24
9-36
40
12
250
25
82
Short Circuit Protection(Automatic recovery)
WRF2415ZD-3W
24
9-36
40
15
200
20
84
Internal SMD construction
WRF2424ZD-3W
24
9-36
40
24
125
13
82
WRE4805ZD-3W
48
18-72
80
±5
±300
±30
80
WRE4812ZD-3W
48
18-72
80
±12
±125
±13
82
FEATURES
High Efficiency up to 84%
◆
Operating Temperature: -40℃ to +85℃
◆
Max.
Min.
3KVDC Input/Output Isolation
◆
◆
◆
No Heat Sink Required
◆
Industry Standard Pinout
◆
WRE4815ZD-3W
48
18-72
80
±15
±100
±10
84
MTBF>1,000,000 hours
WRE4824ZD-3W
48
18-72
80
±24
±63
±6
84
RoHS Compliance
WRF4803ZD-3W
48
18-72
80
3.3
909
91
77
WRF4805ZD-3W
48
18-72
80
5
600
60
80
WRF4812ZD-3W
48
18-72
80
12
250
25
82
WRF4815ZD-3W
48
18-72
80
15
200
20
84
WRF4824ZD-3W
48
18-72
80
24
125
13
84
◆
◆
MODEL SELECTION
①
②
③ ④ ⑤
⑥
WRE 24 05 Z D -3W
①Product Series
②Input Voltage
③Output Voltage 1st ④Wide (4:1) Input Range
⑤DIP24 Package Style ⑥Rated Power
Note:
1.*Input voltage can't exceed this value, or will cause the permanent damage.
2. The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
3. Operation under 10% load will not damage the converter; However, they may not meet all specification
listed.
APPLICATIONS
The WRE_ZD-3W&WRF_ZD-3W Series
are specially designed for applications where a
wide range input voltage power supplies are
isolated from the input power supply in a
distributed power supply system on a circuit
board.
These products apply to:
1) Where the voltage of the input power
supply is wide range (voltage range≤4:1);
2) Where isolation is necessary between
input and output (Isolation Voltage≤3000VDC);
3) Where the regulation of the output voltage
and the output ripple noise are demanded.
MICRODC RESERVES THE COPYRIGHT
ISOLATION SPECIFICATIONS
Parameter
Test conditions
Max.
Units
3
W
±1
±3
%
±3
±5
%
From 10% to 100% load
±0.5
±2*
%
Line Regulation(at full load)
Input voltage from low to high
±0.2
±0.5
Temperature Drift(Vout)
Refer to recommended circuit
±0.02
Ripple**
20MHz bandwidth
20
50
mVp-p
Noise**
20MHz bandwidth
75
150
mVp-p
Switching Frequency
100% load,nominal Input voltage
300
Output Power
See below products program
Positive Voltage accuracy
Refer to recommended circuit
Negative Voltage accuracy
Refer to recommended circuit
Load Regulation
Min.
Typ.
0.3
%
%/℃
KHz
*Dual output models unbalanced load: ±5%
**Test ripple and noise by “Parallel cable”method. See detailed operation instructions at Testing of Power
Converter section, application notes.
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 2
WRE-ZD-3W&WRF-ZD-3W Series
OUTPUT SPECIFICATIONS
Parameter
APPLICATION NOTE
Test conditions
Min
Typ.
Storage Humidity
Max
Uni
95
%
Operating Temperature
-40
85
℃
Storage Temperature
-55
125
℃
Temp. rise at full load
40
300
Requirement Output Load
In order to ensure the product operate efficiently and reliably, in addition
to a max load (namely full load), a minimum load is specified for this
kind of DC/DC converter. Make sure the specified range of input voltage
is not exceeded, the minimum output load no less than 10% load. If
℃
the actual load is less than the specified minimum load, the output ripple
℃
may increase sharply while its efficiency and reliability will reduce
Lead Temperature
1.5mm from case for 10 seconds
Isolation voltage
Tested for 1 minute and 1mA max
3000
VDC
greatly. If the actual output power is very small, please add an
Isolation resistance
Test at 500VDC
1000
MΩ
appropriate resistor as extra loading, or contact our company for other
mW
lower output power products.
No-load power consumption
500
Cooling
Recommended Circuit
Free air convection
Case Material
All the WRE_ZD-3W&WRF_ZD-3W Series have been tested according
Plastic(UL94-V0)
Short Circuit Protection
to the following recommended testing circuit before leaving factory. (See
Continuous, automatic recovery
MTBF
1000
Weight
Figure 1).
K hours
17
g
TYPICAL CHARECTERISTICS
If you want to further decrease the input/output ripple, you can increase
capacitance properly or choose capacitors with low ESR. However, the
capacitance of the output filter capacitor must be proper. If the
capacitance is too big, a startup problem might arise. For every channel
of output, provided the safe and reliable operation is ensured, the
OUTLINE DIMENSIONS & FOOTPRINT DETAILS
greatest capacitance of its filter capacitor sees (Table 1). General:
MECHANICAL DIMENSIONS
RECOMMENDED FOOTPRINT(TOP VIEW)
Cin:
24V&48V
10µF-47µF
Cout: 10µF/100mA
Input Current
When it is used in unregulated power supply, be sure that the fluctuating
range of the power supply and the rippled voltage do not exceed the
TUBE OUTLINE DIMENSIONS
module standard. Input current of power supply should afford the startup
current of this kind of DC/DC module (See figure 2), General:
Note:
Unit:mm[inch]
Pin diameter tolerances:±0.10mm[±0.004inch]
General tolerances: ±0.25mm[±0.010inch]
Ip ≤1.6*Iin-max
FOOTPRINT DETAILS
Pin
Single
Dual
2,3
GND
GND
9
No Pin
0V
11
NC
-Vo
14
+Vo
+Vo
16
0V
0V
22,23
Vin
Vin
NC: No connection.
http://www.microdc.cn
Note:
Unit :mm[inch]
General tolerances:±0.50mm[±0.020inch]
L=530mm[20.866inch]
Tube Quantity: 15pcs
L=220mm[8.661inch]
Tube Quantity: 6pcs
No parallel connection or plug and play.
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646