MORNSUN WRA4805SP-3W

WRA_SP-3W & WRB_SP-3W Series
3W, WIDE INPUT, IAOLATED & REGULATED
DUAL/SINGLE OUTPUT DIP DC-DC CONVERTER
multi-country patent protection RoHS
PRODUCT PROGRAM
FEATURES
Wide (2:1) input range
Efficiency up to 82%
Short circuit protection(automatic recovery)
Operating temperature: -40°C to +85°C
Internal SMD construction
1.5KVDC Isolation
Metal shielding package
No Heat sink required
No external component required
Industry standard Pinout
MTBF>1,000,000 hours
RoHS Compliance
APPLICATIONS
The WRB_SP-3W & WRA_SP-3W Series are
specially designed for applications where a wide
range input voltage power supplies are isolated
from the input power supply in a distributed
power supply system on a circuit board. These
products apply to:
1) Where the voltage of the input power supply
is wide range (voltage range: 2:1);
2) Where isolation is necessary between input
and output(isolation voltage≤1500VDC);
3) Where the regulation of the output voltage
and the output ripple noise are demanded.
MODEL SELECTION
WRB0512SP-3W
Rated Power
Package Style
Output Voltage
Input Voltage
Product Series
Part
Number
Input
Voltage (VDC)
Nominal Range
Max*
WRA0505SP-3W
WRA0509SP-3W
WRA0512SP-3W
WRA0515SP-3W
WRB0505SP-3W
WRB0509SP-3W
WRB0512SP-3W
WRB0515SP-3W
WRA1205SP-3W
WRA1209SP-3W
WRA1212SP-3W
WRA1215SP-3W
WRB1205SP-3W
WRB1209SP-3W
WRB1212SP-3W
WRB1215SP-3W
WRB1224SP-3W
WRA2405SP-3W
WRA2409SP-3W
WRA2412SP-3W
WRA2415SP-3W
WRB2405SP-3W
WRB2409SP-3W
WRB2412SP-3W
WRB2415SP-3W
WRB2424SP-3W
WRA4805SP-3W
WRA4809SP-3W
WRA4812SP-3W
WRA4815SP-3W
WRB4805SP-3W
WRB4809SP-3W
WRB4812SP-3W
WRB4815SP-3W
WRB4824SP-3W
5
4.5-9
11
12
9-18
22
24
18-36
40
48
36-72
80
Voltage
(VDC)
±5
±9
±12
±15
5
9
12
15
±5
±9
±12
±15
5
9
12
15
24
±5
±9
±12
±15
5
9
12
15
24
±5
±9
±12
±15
5
9
12
15
24
Output
Current
Max
±300
±166
±125
±100
600
333
250
200
±300
±166
±125
±100
600
333
250
200
125
±300
±166
±125
±100
600
333
250
200
125
±300
±166
±125
±100
600
333
250
200
125
(mA)
Min
±30
±16
±12
±10
60
33
25
20
±30
±16
±12
±10
60
33
25
20
12
±30
±16
±12
±10
60
33
25
20
12
±30
±16
±12
±10
60
33
25
20
12
Efficiency
(%, Typ)
68
70
72
71
68
70
72
71
74
76
78
79
76
78
80
79
81
78
80
82
81
78
80
82
81
80
78
79
80
81
78
79
80
81
80
*Input voltage can’t exceed this value, or will cause the permanent damage.
Note: The load shouldn't be less than 10%, otherwise ripple will increase dramatically.
Operation under 10% load will not damage the converter; However, they may not meet all specification
listed.
OUTPUT SPECIFICATIONS
MORNSUN Science & Technology co.,Ltd.
Item
Output power
Positive voltage accuracy
Negative voltage accuracy
Load regulation
Address: 2th floor 6th building, Hangzhou
Industrial District, Guangzhou, China
Tel: 86-20-38601850
Fax: 86-20-38601272
http://www.mornsun-power.com
Line regulation
Temperature drift (Vout)
Ripple & Noise**
Switching frequency
Test conditions
Refer to product program
Refer to recommended circuit
Refer to recommended circuit
From 10% to 100% load
Input voltage from low to high
Refer to recommended circuit
20MHz Bandwidth
100% load, nominal input voltage
Min
0.3
Typ
±1
±3
±0.5
±0.2
75
300
Max
Units
3
W
±3
±5
%
±1*
±0.5
±0.03 %/°C
150 mVp-p
KHz
*Dual output models unbalanced load: ±5%.
**Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power
Converter section, application notes.
MORNSUN reserves the copyright
Specifications subject to change without notice.
WRA_SP-3W & WRB_SP-3W
A/1-2008
Page 1 of 2
COMMON SPECIFICATIONS
Item
Test Conditions
Min
Typ
Storage humidity
Max
Units
Recommended Circuit
All the WRA_SP-3W & WRB_SP-3W Series
95
%
have been tested according to the following
Operating temperature
-40
85
Storage temperature
-55
125
Temp. rise at full load
Lead temperature
factory (Figure 1). This series should be tested
°C
15
1.5mm from case for 10 seconds
300
No-load power consumption
Isolation voltage
recommended testing circuit before leaving
W
Tested for 1 minute and 1 mA max 1500
Test at 500VDC
Isolation Capacitance
Input/Output
MΩ
100
pF
Free air convection
Short circuit protection
Ci n
VDC
1000
Cooling
+Vout
Vin
0.2
Isolation resistance
under load.
+Vout
DC
DC
0V
GND
1000
Weight
0V
-Vout
Cin
Aluminium alloy
MTBF
DC
Single Output
Vin
Continuous, automatic recovery
Case material
DC
GND
K hours
15
g
Note:
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load
unless otherwise specified.
2.See below recommended circuits for more details.
If
you
input/output
(Figure 1)
want to further
ripple,
decrease
you
can
the
increase
capacitance properly or choose capacitors with
low ESR. However, the capacitance of the
output filter capacitor must be proper. If the
capacitance is too big, a startup problem might
TYPICAL CHARACTERISTICS
arise. For every channel of output, provided the
safe and reliable operation is ensured, the
greatest capacitance of its filter capacitor sees
(Table 1). General:
Cin:
100
Operating Temp.( C )
OUTLINE DIMENSIONS& PIN CONNECTIONS
35.00 (1.378)
100μF
9
680
±9
470
12
470
±12
330
15
330
±15
220
24
220
-
-
FOOTPRINT DETAILS
2
1
3
(Bottom View)
4
7.62 7.62
(0.300)(0.300)
23.00(0.905)
7.62
(0.300)
3.88
(0.153)
First Angle Projection
5
2.90
(0.11 4)
5V&12V
24V&48V
10μF-47μF
Cout: 10μF/100mA
Output External Capacitor Table(Table 1)
Single Vout
Cout Dual Vout Cout
(VDC)
(uF)
(VDC)
(uF)
5
1000
±5
680
Pin
1
2
3
4
5
Single
Vin
GND
0V
No Pin
+Vo
Dual
Vin
GND
-Vo
0V
+Vo
Input Current
When it is used in unregulated power supply,
be sure that the fluctuating range of the power
supply and the rippled voltage do not exceed the
module standard. Input current of power supply
should afford the startup current of this kind of
29.21(1.150)
DC/DC module. (Figure 2)
0.50
(0.020)
Input Current(A)
(Side View)
4.10
(0.161)
8.50
(0.335)
General: Ip ≤1.4*Iin-max
Note:
Unit:mm(inch )
Pin diameter:0.80mm(0.031inch )
Pin diameter tolerances: 0.05mm( 0.002inch)
General to lerances: 0.25mm( 0.010inch)
Ip
Input Voltage
Range
APPLICATION NOTE
Requirement on output load
In order to ensure the product operate efficiently and reliably, in addition to a max load
Input Voltage (V)
(namely full load), a minimum load is specified for this kind of DC/DC converter. Make sure
the specified range of input voltage is not exceeded, the minimum output load no less than
No parallel connection or plug and play.
10% load. If the actual load is less than the specified minimum load, the output ripple may
increase sharply while its efficiency and reliability will reduce greatly. If the actual output
power is very small, please add an appropriate resistor as extra loading, or contact our
company for other lower output power products.
MORNSUN reserves the copyright
Specifications subject to change without notice.
WRA_SP-3W & WRB_SP-3W
A/1-2008
Page 2 of 2