ALPHA AT004N3-11

GaAs 30 dB IC Voltage Variable Dual
Control Attenuator DC–4 GHz
AT004N3-11
Features
-11
■ Dual Control Voltages
ORIENTATION
MARK
■ Low Insertion Loss
■ 8 Lead Hermetic Surface Mount Package
■ Capable of Meeting MIL-STD
Requirements5
0.150
(3.81 mm)
0.050
(1.27 mm)
TYP.
Description
The AT004N3-11 is a GaAs IC FET non-reflective bridged
“T” attenuator. This device provides over 30 dB of
“matched” attenuation with the input and output VSWR
less than 1.5:1 under all attenuation values. The
applications for these fast attenuators are AGC circuits and
variable level control in high reliability and
telecommunication systems.
0.180 (4.57 mm)
SQ. MAX.
0.017 (0.43 mm)
0.013 (0.33 mm)
0.400 (10.16 mm)
0.380 (9.65 mm)
0.070 (1.78 mm)
0.040 (1.02 mm)
0.075
(1.91 mm)
MAX.
0.006 (0.15 mm)
0.004 (0.10 mm)
0.250 (6.35 mm)
0.200 (5.08 mm)
Electrical Specifications at 25°C
Parameter1
Insertion
Frequency4
Loss2
Min.
DC–1.0 GHz
DC–2.0 GHz
DC–4.0 GHz
Attenuation Range
DC–1.0 GHz
DC–2.0 GHz
DC–4.0 GHz
VSWR (I/O)
DC–2.0 GHz
DC–4.0 GHz
30
29
26
Typ.
Max.
Unit
0.8
1.0
1.2
1.0
1.2
1.4
dB
dB
dB
35
33
30
dB
dB
dB
1.25:1
1.40:1
1.3:1
1.5:1
Typ.
Max.
Operating Characteristics at 25°C
Parameter
Condition
Switching Characteristics
Rise, Fall (10/90% or 90/10% RF)
On, Off (50% CTL to 90/10% RF)
Video Feedthru3
Input Power for 1 dB Compression
For All Attenuation Levels
Control Voltages
VLow = 0 to -0.2 V @ 20 µA Max.
VHigh = -5 V @ 50 µA Max.
Frequency
0.5–4 GHz
0.05 GHz
Min.
Unit
7
10
20
ns
ns
mV
0
-3
dBm
dBm
1. All measurements made in a 50 Ω system, unless otherwise specified.
2. Insertion loss changes by 0.003 dB/°C.
3. Video feedthru measured with 1 ns risetime pulse and 500 MHz bandwidth.
4. DC = 300 kHz.
5. See Quality/Reliability section.
Alpha Industries, Inc. [781] 935-5150 • Fax [617] 824-4579 • Email [email protected] • www.alphaind.com
Specifications subject to change without notice. 3/99A
1
GaAs 30 dB IC Voltage Variable Dual Control Attenuator DC–4 GHz
AT004N3-11
2.4
50
2.0
40
1.5
Attenuation (dB)
Insertion Loss (dB)
Typical Performance Data
+85˚C
1.2
-55˚C
30
20
0.8
10
0.4
DC
1
2
3
0
DC
4
1
2
3
4
Frequency (GHz)
Frequency (GHz)
Insertion Loss vs. Frequency
Attenuation (By State) vs. Frequency
Typical Transfer Curve
F = 1 GHz, VP1 = -3.5 V
F = 50 MHz
-1.0
V1 (Series)
-2.0
-3.0
V2 (Shunt)
-4.0
-5.0
0
10
5
20
PIN at 1.0 dB Compression (dBm)
V1 V2 Control Voltages (V)
0
15
20
25
30
15
10
5
0
-5
0
35
5
10
15
20
25
Relative Attenuation (dB)
Attenuation (dB)
Relative Attenuation vs. Control Voltages
Attenuation vs. 1.0 dB Compression Point
Absolute Maximum Ratings
Characteristic
RF Input Power (RF In)
Control Voltage (VC)
Truth Table
V1
V2
Attenuation
J1–J2
0
-5
Insertion Loss
-5
0
Full Attenuation
Value
10 mW > 500 MHz
4 mW @ 50 MHz
+0.2 V, -10 V
Operating Temperature (TOP)
-55°C to +125°C
Storage Temperature (TST)
-65°C to +150°C
Thermal Resistance (ΘJC)
25°C/W
Pin Out
GND
J1
GND
V2
2
30
Alpha Industries, Inc. [781] 935-5150 • Fax [617] 824-4579 • Email [email protected] • www.alphaind.com
Specifications subject to change without notice. 3/99A
GND
J2
GND
V1