AUK S4560

F
S4560
Semiconductor
Dual high slew rate OP AMP
Description
The S4560 is dual operational amplifiers which achieve approximately twice the high output
current of the S4560, as well as featuring a higher slew rate of 4V/us, a gain band width of
10MHz, and an improved frequency characteristic.
Features
•
•
•
•
•
Built-in output short-circuit protection circuit.
Internal phase correction.
No latch-up
Wide same phase mode and differential voltage ranges
High gain. low noise
Applications
•
•
•
•
Active filters
Audio amplifiers
VCOs
Other electronic circuits
Ordering Information
Type NO.
S4560
Marking
Package Code
S4560
SOP-8
Outline Dimensions
unit : mm
Block Diagram
KSI-K004-001
1
S4560
Absolute maximum ratings
Ta = 25 °C
Characteristic
Symbol
Ratings
Unit
Supply voltage
VCC
±18
V
Differential input voltage
VID
±30
V
Input voltage
VIC
-Vcc~Vcc
V
Power Dissipation
PD*
550
mW
Operating temperature
Topr
-40 ~ +85
°C
Storage temperature
Tstg
-55 ~ +125
°C
* Refer to Pd characteristics diagram. The values for the S4560 are those when it is mounted on a glass epoxy
PCB(50 ㎜×50 ㎜×1.6 ㎜).
Electrical Characteristics
(Unless otherwise specified. VCC = +15V, VEE=-15V and
Characteristic
Symbol
Input offset voltage
VIOS
Input offset current
IIOS
Input bias current
Ta = 25 °C)
Test Condition
Rg ≤ 10 ㏀
Min. Typ. Max.
Unit
-
0.5
6
mV
-
-
5
200
nA
IIB
-
-
50
500
nA
Input common mode
Voltage Range
VICR
-
±12
±14
-
V
±14
VOM
RL≥ 10 ㏀
±12
Maximum Output Voltage
-
V
RL≥ 2 ㏀
±10
±13
-
V
Vout=±10V, RL≥ 2 ㏀
86
100
-
dB
Large signal Voltage Gain
GV
Common mode
rejection ratio
CMRR
Rg ≤ 10 ㏀
70
90
-
dB
Power supply
rejection ratio
PSRR
Rg ≤ 10 ㏀
-
30
150
uV/V
GV=1, RL≥ 2 ㏀
-
4.0
-
V/us
-
-
2.2
uV
-
10
-
MHz
Slew Rate
SR
Input conversion
noise voltage
Vn
Gain band width product
GBW
f=10kHz
KSI-K004-001
2
S4560
Electrical Characteristic Curves
Fig. 1 GV – f
Fig. 2 VOP-P – f
(Vcc/VEE=±15V,RL=2 ㏀,Ta=25℃)
(Vcc/VEE=±15V,Ta=25℃)
㏀
Fig. 4 VICR - VCC / VEE
Fig. 3 IIB - Ta
(Ta=25℃)
(Vcc/VEE=±15V)
/
Fig. 5 IQ - VCC / V EE
±
Fig. 6 IIB - VCC
(Ta=25℃)
(Ta=25℃)
/
KSI-K004-001
3
S4560
These AUK products are intended for usage in general electronic equipments(Office and
communication equipment, measuring equipment, domestic electrification, etc.).
Please make sure that you consult with us before you use these AUK products in equipments which require high quality and/or reliability, and in equipments which could have
major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic
signal, combustion central, all types of safety device, etc.).
AUK cannot accept liability to any damage which may occur in case these AUK products
were used in the mentioned equipments without prior consultation with AUK.
KSI-K004-001
4