BB REG5608

®
REG5608
RE
G5
60
8
RE
G5
60
8
LOW CAPACITANCE 18-Line SCSI
ACTIVE TERMINATOR
FEATURES
DESCRIPTION
● ACTIVE 18-Line TERMINATOR
● 2pF CAPACITANCE PER LINE
IMPORTANT FOR SCSI FAST-20
● ON-CHIP TERMINATION RESISTORS
● ALL TERMINATIONS DISCONNECT WITH
SINGLE LOGIC SIGNAL
● 325mA CURRENT SINKING FOR ACTIVE
NEGATION
● 22.4mA PER LINE DURING ASSERTION
The REG5608 is a low capacitance 18-line active
terminator for SCSI (Small Computer Systems
Interface) parallel bus systems. On-chip resistors and
voltage regulator provide the prescribed SCSI bus
termination. Low line capacitance (2pF) meets
requirements for high data rate systems.
All terminations can be disconnected from the bus
with a single logic control line. In the disconnect
mode, output lines remain high impedance with or
without power applied. This allows “hot socket”
equipment plugging as required for “plug and play”
applications.
● CURRENT LIMIT AND THERMAL LIMIT
● HOT-SOCKET CAPABLE
● 28-Lead SOIC and SSOP PACKAGES
The internal voltage regulator is temperature-compensated to assure proper termination characteristics over
a wide operating range. Output current and thermal
limit circuitry protect against damage.
The REG5608 is available in 28-lead SOIC and
fine-pitch SSOP packages and is specified for 0°C to
70°C operation.
2.9V
Regulator
TERMPWR
Reg Out
110Ω
110Ω
Thermal
Limit
Current
Limit
Disconnect
SCSI
Termination
Lines
110Ω
Switch
Drive
(18 lines)
International Airport Industrial Park • Mailing Address: PO Box 11400 • Tucson, AZ 85734 • Street Address: 6730 S. Tucson Blvd. • Tucson, AZ 85706
Tel: (520) 746-1111 • Twx: 910-952-1111 • Cable: BBRCORP • Telex: 066-6491 • FAX: (520) 889-1510 • Immediate Product Info: (800) 548-6132
© 1995 Burr-Brown Corporation
PDS-1305
Printed in U.S.A. November, 1995
SPECIFICATIONS
At TA = 0°C to +70°C, TERMPWR = 4.75V, and Disconnect = Low and IREG OUT = 0, unless otherwise specified.
REG5608U
REG5608E
PARAMETERS
CONDITIONS
POWER SUPPLY
TERMPWR Supply Voltage
TERMPWR Supply Current
TERMINATION LINES
Termination Impedance
Output Termination High Voltage(1)
Maximum Line Current
Line Leakage Current
Line Capacitance
REG5608U SO-28 Package
REG5608E SSOP-28
REGULATOR
Output Voltage
Line Regulation
Drop-Out Voltage
Source Current Limit
Sink Current Limit
Thermal Shutdown, TJ
DISCONNECT LOGIC INPUT
Input High Voltage
Input Low Voltage
Input Low Current
Threshold Hysteresis
MIN
TYP
4
All Termination Lines Open Circuit
All VLINE = 0.5V
Disconnect = High
∆ILINE = 5 to 15mA
TERMPWR = 4.0V
VLINE = 0.5V
TA = 0°C to 70°C
TA = 25°C
TERMPWR = 4.0V, TA=0°C to 70°C(1)
TERMPWR = 4.0V, TA = 25°C(1)
Disconnect = High
TERMPWR = 5.25V, VLINE = 0V
TERMPWR = 5.25V, VLINE = 5.25V
TERMPWR = 0V, VLINE = 5.25V
Disconnect = High
18
390
5
MAX
UNITS
5.25
25
430
V
mA
mA
mA
104.5
2.65
110
2.9
115.5
3.0
Ω
V
19.8
20.3
19.0
19.5
21.5
21.5
21.5
21.5
22.4
22.4
22.4
22.4
mA
mA
mA
mA
10
10
10
400
400
400
nA
nA
nA
2.5
1.8
2.8
TERMPWR = 4.0 to 6.0V
All VLINE = 0.5V, ∆Reg Out = 100mV
Reg Out = 0V
Reg Out = 3.5V
400
100
(Logic High = Switches Open)
(Logic Low = Switches Closed)
2
0
2.9
2
0.9
550
325
145
10
50
TEMPERATURE RANGE
Specification
Storage
θJL (Junction to Lead)
0
-40
25
20
pF
pF
3.0
20
1.2
950
500
V
mV
V
mA
mA
°C
TERMPWR
0.8
20
V
V
µA
mV
70
150
°C
°C
°C/W
NOTE: (1) Measurement of each termination line while the other 17 lines are held low (VLINE = 0.5V).
The information provided herein is believed to be reliable; however, BURR-BROWN assumes no responsibility for inaccuracies or omissions. BURR-BROWN assumes no responsibility
for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights or
licenses to any of the circuits described herein are implied or granted to any third party. BURR-BROWN does not authorize or warrant any BURR-BROWN product for use in life support
devices and/or systems.
®
REG5608
2
CONNECTION DIAGRAM
Top View
SOIC
SSOP
Disconnect
1
28
GND
Termination Line 1
2
27
Termination Line 18
Termination Line 2
3
26
Termination Line 17
Termination Line 3
4
25
Termination Line 16
Termination Line 4
5
24
Termination Line 15
Termination Line 5
6
23
Termination Line 14
(Thermal) GND
7
22
GND (Thermal)
8
21
GND (Thermal)
REG5608
(Thermal) GND
(Thermal) GND
9
20
GND (Thermal)
Termination Line 6
10
19
Termination Line 13
Termination Line 7
11
18
Termination Line 12
Termination Line 8
12
17
Termination Line 11
Termination Line 9
13
16
Termination Line 10
TERMPWR
14
15
Reg Out
NOTE: Pin 28 is electrical ground. Connect pins
7, 8, 9, 20, 21, 22 to large circuit trace for proper heat
sinking. Connect to ground or leave open-circuit.
ABSOLUTE MAXIMUM RATINGS
ELECTROSTATIC
DISCHARGE SENSITIVITY
TERMPWR Voltage ............................................................................. +7V
Signal Line Voltage ................................................................... 0V to +7V
Junction Temperature .................................................................... +150°C
Storage Temperature ..................................................... –40°C to +150°C
This integrated circuit can be damaged by ESD. Burr-Brown
recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling
and installation procedures can cause damage.
PACKAGE/ORDERING INFORMATION
MODEL
REG5608U
REG5608E
PACKAGE
PACKAGE DRAWING
NUMBER(1)
Plastic 28-Lead SOIC
Plastic 28-Lead SSOP
217
324
NOTE: (1) For detailed drawing and dimension table, please see end of data
sheet, or Appendix D of Burr-Brown IC Data Book.
®
3
REG5608
TYPICAL PERFORMANCE CURVES
TA = 25°C, TERMPWR = 4.75V unless otherwise noted.
TERMINATION CURRENT vs TEMPERATURE
LINE CAPACITANCE vs PIN NUMBER
10
Line Capacitance (pF)
Termination Current (mA)
23
22
VLINE = 0.5V
21
20
8
First-Generation Terminator
6
4
REG5608U SOIC Package
2
19
–25
REG5608E SSOP Package
0
0
25
50
75
100
125
2
27
Temperature (°C)
3
26
4
25
5
24
6
23
10
19
11
18
12
17
13
16
Pin Number
shutdown during normal operation is an indication of
inadequate heat sinking and/or excessive power
dissipation.
APPLICATION INFORMATION
Figure 1 shows a typical SCSI parallel bus termination
circuit. Bypass capacitors should be connected to TERMPWR
and Reg Out pins as shown.
The terminator's internal power is dissipated primarily by
conduction through the package leads to circuit board traces.
It is important to connect the six thermal ground leads (7, 8,
9, 20, 21, 22) to a large circuit trace—see Figure 2. Typical
measured values of thermal resistance for various circuit
board materials are shown. These are approximate values.
Variations in circuit board pattern, mounting techniques, air
flow, proximity to other circuit boards and heat sources will
affect thermal performance.
Line capacitance of the REG5608 has been reduced to less
than one-fourth that of the first-generation integrated
terminator ICs. Capacitance difference between package
types and variation by pin number is shown in the typical
performance curve, “Line Capacitance vs Pin Number.” It
shows that the SSOP package provides the lowest capacitance with typical values under 2pF. This variation is
produced primarily by the differences in the interconnection
length to the IC. Of course, actual line capacitance on a
circuit board is generally determined by circuit board layout.
To achieve lowest line capacitance, minimize the total circuit
board interconnection length from the interface cable to the
SCSI transceiver IC and to the REG5608 terminator.
A simple experiment will determine whether the actual circuit
board layout is adequate (i.e., θBA is low enough) so that the
maximum recommended junction temperature of the REG5608
will not be exceeded. The procedure uses the internal thermal
shutdown feature of the REG5608 (at TJ ≈ 145°C) to
determine when the junction is approximately 20°C above the
maximum recommended junction temperature (TJ = 125°C).
Operate the circuit with normal or other desired test electrical
conditions. Increase the ambient temperature and determine
the value at which thermal limit occurs (by sensing a sudden
drop in VREG output). At this point TJ is approximately 145°C.
If this occurs at an ambient temperature of more than 20°C
above the system ambient temperature design goal, the TJ will
not exceed 125°C under the same electrical conditions when
the ambient temperature is at the system design goal value.
THERMAL CONSIDERATIONS
The REG5608 has internal current limit and thermal
shutdown that protect it from damage in case of output
short-circuit or overload. The current limit is approximately 550mA and thermal shutdown activates at a
junction temperature of approximately 145°C. For good
long-term reliability, the junction temperature should not
exceed 125°C. Any tendency to activate the thermal
®
REG5608
4
4V to 5.25V
4.7µF Tantalum
+
14
TERMPWR
Low = Termination On
High = Disconnect
1
28
Disconnect
REG5608
Reg
Out
15
T18
To
Controller
Tranceivers
+ 4.7µF
Tantalum
Gnd
T1
27
2
(18 Lines)
To other SCSI Devices
and opposite-end
termination
SCSI Parallel Bus
FIGURE 1. SCSI Parallel Bus Termination.
Thermal ground (leads 7, 8, 9, 20, 21, 22).
Connect to circuit ground or leave open-circuit.
TJ = TA + PD θJA
PACKAGE
CIRCUIT BOARD
MATERIAL
θJL
θBA
θJA
JUNCTION TO LEAD + BOARD TO AMBIENT = JUNCTION TO AMBIENT
(°C/W)
(°C/W)
(°C/W)
SO-28
1-Layer(1)
3-Layer(2)
Aluminum(3)
20
20
20
+
+
+
30
21
12
=
=
=
50
41
32
SSOP-28
1-Layer(1)
3-Layer(2)
Aluminum(3)
20
20
20
+
+
+
36
23
13
=
=
=
56
43
33
NOTES: (1) Single-side layout on 0.062 inch FR4, 1 oz copper. (2) Three-layer layout on 0.062 inch FR4, 1 oz copper.
(3) Aluminum 0.062 inch substrate, 0.003 insulation, one layer, 1 oz copper (Thermal Clad, Bergqueist Co.)
FIGURE 2. Circuit Board Layout.
®
5
REG5608