SN54ACT04, SN74ACT04 HEX INVERTERS SCAS518A – JULY 1995 – REVISED APRIL 1996 D D D SN54ACT04 . . . J OR W PACKAGE SN74ACT04 . . . D, DB, N, OR PW PACKAGE (TOP VIEW) Inputs Are TTL-Voltage Compatible EPIC (Enhanced-Performance Implanted CMOS) 1-µm Process Package Options Include Plastic Small-Outline (D), Shrink Small-Outline (DB), Thin Shrink Small-Outline (PW), DIP (N) Packages, Ceramic Chip Carriers (FK), Flat (W), and DIP (J) Packages 1A 1Y 2A 2Y 3A 3Y GND description The ‘ACT04 contain six independent inverters. The devices perform the Boolean function Y = A. L L H 3 12 4 11 5 10 6 9 7 8 VCC 6A 6Y 5A 5Y 4A 4Y 4 3 2 1 20 19 18 5 17 6 16 7 15 8 14 9 10 11 12 13 6Y NC 5A NC 5Y 3Y GND NC 4Y 4A H 13 1Y 1A NC VCC 6A 2A NC 2Y NC 3A FUNCTION TABLE (each inverter) OUTPUT Y 14 2 SN54ACT04 . . . FK PACKAGE (TOP VIEW) The SN54ACT04 is characterized for operation over the full military temperature range of – 55°C to 125°C. The SN74ACT04 is characterized for operation from – 40°C to 85°C. INPUT A 1 NC – No internal connection logic symbol† 1A 2A 3A 4A 5A 6A 1 logic diagram, each inverter (positive logic) 2 1 3 4 5 6 9 8 11 10 13 12 1Y A Y 2Y 3Y 4Y 5Y 6Y † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. Pin numbers shown are for the D, DB, J, N, PW, and W packages. Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. EPIC is a trademark of Texas Instruments Incorporated. Copyright 1996, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 1 SN54ACT04, SN74ACT04 HEX INVERTERS SCAS518A – JULY 1995 – REVISED APRIL 1996 absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±200 mA Maximum power dissipation at TA = 55°C (in still air) (see Note 2): D package . . . . . . . . . . . . . . . . . . 1.25 W DB package . . . . . . . . . . . . . . . . . 0.5 W N package . . . . . . . . . . . . . . . . . . . 1.1 W PW package . . . . . . . . . . . . . . . . . 0.5 W Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed. 2. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750 mils, except for the N package, which has a trace length of zero. recommended operating conditions (see Note 3) SN54ACT04 MAX MIN MAX 4.5 5.5 4.5 5.5 VCC VIH Supply voltage VIL VI Low-level input voltage Input voltage 0 VO IOH Output voltage 0 IOL ∆t /∆v Low-level output current High-level input voltage 2 2 0.8 High-level output current VCC VCC 0 0 – 24 24 Input transition rise or fall rate TA Operating free-air temperature NOTE 3: Unused inputs must be held high or low to prevent them from floating. 2 SN74ACT04 MIN POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 UNIT V V 0.8 V VCC VCC V – 24 mA V 24 mA 0 8 0 8 ns / V – 55 125 – 40 85 °C SN54ACT04, SN74ACT04 HEX INVERTERS SCAS518A – JULY 1995 – REVISED APRIL 1996 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS VCC 4.5 V IOH = – 50 µA VOH A IOL = – 24 mA IOH = – 50 mA† IOH = – 75 mA† TA = 25°C TYP MAX SN54ACT04 MIN MAX IOL = 50 mA† IOL = 75 mA† MIN 4.49 4.4 5.5 V 5.4 5.49 5.4 5.4 4.5 V 3.86 3.7 3.76 5.5 V 4.86 4.7 4.76 ∆ICC‡ One input at 3.4 V, Other inputs at GND or VCC IO = 0 V 3.85 4.5 V 0.001 0.1 0.1 5.5 V 0.001 0.1 0.1 0.1 0.1 4.5 V 0.36 0.5 0.44 5.5 V 0.36 0.5 0.44 V 1.65 5.5 V VI = VCC or GND VI = VCC or GND, UNIT 3.85 5.5 V II ICC MAX 4.4 5.5 V IOL = 24 mA SN74ACT04 4.4 5.5 V IOL = 50 µA VOL MIN 1.65 5.5 V ± 0.1 ±1 ±1 µA 5.5 V 2 40 20 µA 1.6 1.5 mA 5.5 V 0.6 Ci VI = VCC or GND 5V 4.5 † Not more than one output should be tested at a time, and the duration of the test should not exceed 2 ms. ‡ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or VCC. switching characteristics over recommended operating VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1) PARAMETER FROM (INPUT) TO (OUTPUT) tPLH tPHL A Y MIN free-air TA = 25°C TYP MAX pF temperature SN54ACT04 range, SN74ACT04 MIN MAX MIN MAX 1 6 8.5 1 9 1 9 1 5.5 8 1 8.5 1 8.5 UNIT ns operating characteristics, VCC = 5 V, TA = 25°C PARAMETER Cpd TEST CONDITIONS Power dissipation capacitance CL = 50 pF, POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 f = 1 MHz TYP UNIT 45 pF 3 SN54ACT04, SN74ACT04 HEX INVERTERS SCAS518A – JULY 1995 – REVISED APRIL 1996 PARAMETER MEASUREMENT INFORMATION TEST S1 tPLH/tPHL Open From Output Under Test CL = 50 pF (see Note A) S1 Open 1.5 V 1.5 V 0V tPHL tPLH 2 × VCC 500 Ω 3V Input (see Note B) In-Phase Output 50% VCC tPLH tPHL 500 Ω Out-of-Phase Output LOAD CIRCUIT VOH 50% VCC VOL 50% VCC VOH 50% VCC VOL VOLTAGE WAVEFORMS NOTES: A. CL includes probe and jig capacitance. B. All input pulses are supplied by generators having the following characteristics: PRR ≤ 1 MHz, ZO = 50 Ω, tr ≤ 2.5 ns, tf ≤ 2.5 ns. C. The outputs are measured one at a time with one input transition per measurement. Figure 1. Load Circuit and Voltage Waveforms 4 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER’S RISK. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof. Copyright 1998, Texas Instruments Incorporated