DCCOM HVM16

HVM5
DC COMPONENTS CO., LTD.
R
THRU
RECTIFIER SPECIALISTS
HVM16
TECHNICAL SPECIFICATIONS OF HIGH VOLTAGE ASSEMBLIED RECTIFIER
VOLTAGE RANGE - 5000 to 16000 Volts
CURRENT - 0.35 Ampere
FEATURES
*
*
*
*
Low cost
Low leakage
Isolated case
Surge overload rating - 50 amperes peak
HVM
* Low forward voltage drop
MECHANICAL DATA
* Case: Molded plastic
* Epoxy: UL 94V-0 rate flame retardant
* Lead: MIL-STD-202E, Method 208 guaranteed
* Polarity: Color band denotes cathode end
* Mounting position: Any
MAX .
MAX.
MAX .
MAX .
MAX .
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Dimensions in inches and (millimeters)
SYMBOL
HVM5
HVM8
HVM10
HVM12
HVM14
HVM15
HVM16
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
5
8
10
12
14
15
16
K Volts
Maximum RMS Voltage
VRMS
3.5
5.6
7.0
8.4
9.8
10.5
11.2
K Volts
Maximum DC Blocking Voltage
VDC
5
8
10
12
14
15
16
o
Maximum Average Forward Rectified Current at T A = 50 C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC Method)
350
mAmps
I FSM
50
Amps
Maximum Instantaneous Forward Voltage at 0.35A DC
VF
Maximum DC Reverse Current
at Rated DC Blocking Voltage TA = 25 o C
IR
5.0
T J, T STG
-20 to + 135
Operating and Storage Temperature Range
K Volts
IO
8.0
13.5
14.0
Volts
uAmps
0
C
NOTES:1. Enough heat sink must be considered in application.
2. Suffix "-Tox" (e.g.-T01,-T02,.....) for Terminal type.
154
NEXT
NEXT
NEXT
BACK
EXIT
BACK
EXI
BACK EXIT
RA TING AND CHARACTERISTIC CURVES (HVM5 THRU HVM16)
DC COMPONENTS CO., LTD.
R
155
NEXT
NEXT
BACK
BACK
EXIT
EXIT