ETC B104SN01

Standard Name with Version
AU OPTRONICS CORPORATION
Spec. No.:
xxxx-xxx-xxx
Version:
1
Total pages:
4
Date:
2001-JUN-18
Tentative
Module Specification for
10,4" TFT-LCD MODULES
Model Name: B104SN01
Approved by
Checked by
Prepared by
Quality Management Division / AU Optronics Croporation
Customer
Checked & Approved by
AU copyright 2001,
All rights reserved,
Copying forbidden.
2001/07/14
AU Optronics Crop.
1/4
AU Confidential and Property. No Reproduction and Redistribution Allowed!
Record of Revision
Version
Revise Date
Page
1
26/Apr./2000
14
Content
First draft.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
PAGE
1/15
:
Contents:
P2
A. Physical specification
B. Electrical specifications
1. Pin assignment
2. Absolute maximum ratings
3. Electrical characteristics
b. Display color v.s. input data signals
c. Input signal timing
d. Display position
e. Backlight driving conditions
C. Optical specifications
D. Reliability test items
E. Display quality
P12
P12
P10
P11
P9
P8
P7
P6
P5
P5
P4
…
F. Handling precaution
G. Packing form
P3
P3
a. Typical operating conditions
P13
Appendix:
Fig.1 LCM outline dimensions
Fig.2 Timing chart
……………………
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
P14
P15
www.data-modul.de
PAGE
:
2/15
A. Physical specifications
NO.
Item
Specification
1
Display resolution(pixel)
800(H)
2
Active area(mm)
211.2(H)
3
Screen size(inch)
10.4(Diagonal)
4
Pixel pitch(mm)
0.264(H)
5
Color configuration
R. G. B. Vertical stripe
6
Overall dimension(mm)
236(W)
7
Weight(g)
285
Remark
600(V)
158.4(V)
0.264(V)
174.3(H)
5.7(D) ( Max )
Note 1
10
Note 1: Refer to Fig. 1.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
PAGE
:
3/15
B. Electrical specifications
1.Pin assignment
(1).Input signal interface
Pin no
Symbol
Function
1
VCC
+3.3 V power supply
2
VCC
+3.3 V power supply
3
GND
Ground
4
GND
Ground
5
RxIN0-
6
RxIN0+
7
GND
8
RxIN1-
9
RxIN1+
10
GND
11
RxIN2-
12
RxIN2+
13
GND
Ground
14
CKIN-
LVDS receiver signal clock
15
CKIN+
16
GND
17
NC
No Connection
18
NC
No Connection
19
GND
Ground
20
GND
Ground
Etc.
LVDS receiver signal channel 0
Ground
LVDS receiver signal channel 1
Ground
LVDS receiver signal channel 2
Ground
CN1 (20P) connector : HRS DF 19K-20P-1H
or Compatible
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
PAGE
:
4/15
(2) LVDS transmitter/receiver signal mapping
Symbol
Function
TxIN0
R0
Red data (LSB)
TxIN1
R1
Red data
TxIN2
R2
Red data
TxIN3
R3
Red data
TxIN4
R4
Red data
TxIN5
R5
Red data (MSB)
TxIN6
G0
Green data (LSB)
TxIN7
G1
Green data
TxIN8
G2
Green data
TxIN9
G3
Green data
TxIN10
G4
Green data
TxIN11
G5
Green data (MSB)
TxIN12
B0
Blue data (LSB)
TxIN13
B1
Blue data
TxIN14
B2
Blue data
TxIN15
B3
Blue data
TxIN16
B4
Blue data
TxIN17
B5
Blue data (MSB)
TxIN18
Hs
Horizontal sync
TxIN19
Vs
Vertical sync
TxIN20
DE
Data enable
TxCLKIN
CLK
Clock
6 bit red display data
6 bit green display data
6 bits blue display data
Dot clock
2. Absolute maximum ratings
Parameter
(GND = 0 V)
Values
Symbol
Unit
Power voltage
VCC
Min.
-0.3
Input signal voltage
VLH
-0.3
VCC+0.3
Operating temperature
Top
-10
+60
Storage temperature
TST
-20
+70
Remark
Max.
4
VDC
At 25
VDC
At 25
Note 1
Note 1
or
Note 1:The relative humidity must not exceed 90% non-condensing at temperatures of 40
less. At temperatures greater than 40 , the wet bulb temperature must not exceed 39
. When operate at low temperatures, the brightness of CCFL will drop and the life
time of CCFL will be reduced.
Note 2:The unit should not be exposed to corrosive chemicals.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
PAGE
5/15
:
3. Electrical characteristics
a. Typical operating conditions
Item
Power
supply
voltage
Internal
logic
Symbol
Min.
Typ.
Max.
Unit
Input voltage
VCC
3.0
3.3
3.6
V
Current
consumption
IA
310
mArms
IB
330
mArms
Inrush current
I RUSH
-
-
1500
Low voltage
VIL
0
-
0.3 VCC
High voltage
VIH
0.7VCC
-
VCC
VRP
-
-
100
Power ripple voltage
Remark
Note 1
mApeak
Note 2
mVp-p
Note 1:Effective value (mArms) at VCC = 3.3 V/25 .
IA
Black
(0)
64
IB
White
Gray
(7)
64
Black
Vertical stripe line
64 Grayscale
Note 2: Refer to the following power-on condition.
10%
Sequence of Power-on/off and signal-on/off
T3
Power
T1
30ms
T2
T5
Input signal
0
T1 70msec
T2 70msec
300msec
300msec
T5
T3
T4
10msec
Apply the lamp voltage within the LCD operating range. When the backlight turns on before
the LCD operation or the LCD turns off before the backlight turns off, the display may
momentaily become abnormal.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
PAGE
6/15
:
Caution
The above on/off sequence should be applied to avoid abnormal function in the display.
In case of handling:
Make sure to turn off the power when you plug the cable into the input connector or pull the
cable out of the connector.
b. Display color v.s. input data signals
Display colors
Basic
colors
Black
Blue
Red
Magenta
Green
Cyan
Yellow
White
Black
Dark
Red
grayscale
Data signal (0 : Low level, 1: High level)
R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0
0
0
1
1
0
0
1
1
0
0
0
0
0
1
1
0
0
1
1
0
0
0
0
0
1
1
0
0
1
1
0
0
0
0
0
1
1
0
0
1
1
0
0
0
0
0
1
1
0
0
1
1
0
0
1
0
0
1
1
0
0
1
1
0
1
0
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
1
1
1
1
0
0
0
0
1
0
1
0
1
0
1
0
0
0
0
1
0
1
0
1
0
1
0
0
0
0
1
0
1
0
1
0
1
0
0
0
0
1
0
1
0
1
0
1
0
0
0
0
1
0
1
0
1
0
1
0
0
0
0
1
0
1
0
1
0
1
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
0
1
1
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
0
1
1
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
0
1
1
1
0
1
bright
Red
Black
Dark
Green
grayscale
bright
Green
Black
Dark
Blue
grayscale
bright
Blue
Note : Each basic color can be displayed in 64 gray scales using the 6 bit data signals. By
combining the 18-bit data signals(R,G,B), the 262, 144 colors can be achieved on the
display.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
PAGE
:
7/15
c. Input signal timing
Timing diagrams of input signal are shown in Fig 2.
(1). Timing characteristics of input signals
(a) DE mode
Item
Symbol
Min.
Typ.
Max.
Unit
Clock frequency
Fck
38
40
42
MHz
Horizontal blanking
Thb1
50
256
500
Clk
Vertical blanking
Tvb1
10
28
150
Th
Item
Symbol
Min.
Typ.
Max.
Unit
Clock frequency
Fck
38
40
48
MHz
Hsync period
Th
850
1056
1300
Clk
Hsync pulse width
Thw
10
128
-
Clk
Hsync front porch
Thf
15
40
-
Clk
Hsync back porch
Thb
10
88
-
Clk
Hsync blanking
Thb1
50
256
500
Clk
Vsync period
Tv
610
628
750
Th
Vsync pulse width
Tvw
1
4
-
Th
Vsync front porch
Tvf
0
1
-
Th
Vsync blanking
Tvb1
10
28
150
Th
Hsync/Vsync phase shift
Tvpd
2
320
-
Clk
Remark
(b) HV mode
Item
Symbol
Value
Unit
Remark
Description
Horizontal display start The
218
Clk
After falling edge of Hsync, counting 218clk,
then getting valid data from 219th clk’s data.
Vertical display start
25
Th
After falling edge of Vsync, counting 25 Th,
then getting 26 th Th’s data.
Tve
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
PAGE
8/15
:
(2). The timing condition of LVDS
Item
The differential level
Symbol
Min.
Typ.
Max.
Unit
VID
0.1
-
0.6
V
The common mode input voltage
VIC
VID
2
VID
2
-
2.4
V
The input setup time
tsu1
500
-
-
ps
The input hold time
th1
500
-
-
ps
VID
VIAP
VID = VIAP - VIAM
VIAM
tsu1 th1
An
7 LCK
d.Display position
D( 1,1 )
D( 2,1 )
……
D( X,1 )
……
D( 799,1 )
D( 800,1 )
D( 1,2 )
..
.
D( 2,2 )
……
D( X,2 )
..
.
……
D( 799,2 )
..
.
D( 800,2 )
..
.
D( 1,Y )
..
.
D( 2,Y )
D( 799,Y )
..
.
D( 800,Y )
..
.
D( 1,599 )
D( 1,600 )
……
……
……
……
……
D( X,Y )
..
.
D( 2,599 )
……
D( X,599 )
……
D( 799,599) D( 800,599 )
D( 2,600 )
……
D( X,600 )
……
D( 799,600)
……
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
D( 800,600)
www.data-modul.de
PAGE
:
9/15
e.Backlight driving conditions
Parameter
Symbol
Min.
Typ.
Max.
Unit
Remark
Lamp voltage
VL
-
488
-
Vrms
Note 1
Lamp current
IL
-
4.3
-
mArms
Note 1
Power consumption
PL
-
2.1
-
W
Note 2
Lamp starting voltage
VS
TBD
Vrms
TBD
T=0
T=25
Frequency
FL
-
60
-
KHZ
Note 3
Lamp life time
LL
10000
-
-
Hr
Note 1, 4
Note 1: T= 25 , IL = 4.3
Note 2: Inverter should be designed with the characteristic of lamp. When you are designing
the inverter, the output voltage of the inverter should comply with the following
conditions.
(1).The area under the positive and negative cycles of the waveform of the lamp
current and lamp voltage should be area symmetric(the symmetric ratio should be
larger than 90%).
(2).There should not be any spikes in the waveform.
(3).The waveform should be sine wave as possible.
(4).Lamp current should not exceed the maximum value within the operating
temperature (It is prohibited to over the maximum lamp current even if operated in
the non-guaranteed temperature). When lamp current over the maximum value for
a long time, it may cause fire. Therefore, it is recommend that the inverter should
have the current limiter circuit.
Note 3: Lamp frequency may produce interference with horizontal synchronous frequency and
this may cause line flow on the display. Therefore lamp frequency shall be detached
from the horizontal synchronous frequency and its harmonics as far as possible in
order to avoid interference. In case using the inverter by PWM control, PWM
frequency may interference with frame frequency. We suggest that PWM frequency
is same as frame frequency.
Note 4: Brightness to be decrease to the 50% of the initial value.
Note 5: CN2 connector(backlight): JST BHSR-02VS-1
Mating connector: JST SM02B-BHSS-1-TB
Pin no.
Symbol
Function
Remark
1
H
CCFL power supply(H.V.)
Cable color: Pink
2
L
CCFL power supply(GND)
Cable color: White
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
PAGE
10/15
:
C. Optical specifications ( Note 1, Note 2, Note 3 )
Item
Symbol
Condition
Specification
Min.
Typ.
Max.
-
20
30
40
50
150
250
-
10
30
40
40
15
35
45
45
-
130
150
-
-
(0.31)
-
-
(0.33)
-
Rx
-
-
-
Ry
-
-
-
Gx
-
-
-
Gy
-
-
-
Bx
-
-
-
By
-
-
-
W
-
-
1.8
Response time
Rising time
Falling time
Tr
Tf
Contrast ratio
CR
=0
=0
Unit
Remark
ms
Note 4
Note 5
Viewing angle
Top
Bottom
Left
Right
CR
YL
Brightness
Color chromaticity(CIE)
White uniformity
=0
deg.
Note 8
nit
Note 6,7
Wx
=0
Wy
10
Note 9
Note 1: Ambient temperature = 25 .
Note 2: To be measured in dark room after backlight warm up 30 minutes.
Note 3: To be measured with a viewing cone of 1 by Topcon luminance meter BM-5A.
Note 4: Definition of response time:
The output signals of photodetector are measured when the input signals are changed
from “Black” to “White” (falling time) and from “White” to “Black” (rising time), respectively.
The response time interval between the 10% and 90% of amplitudes. Refer to figure as
below.
"Black"
"White"
"White"
Signal(Relative value)
100%
90%
10%
0%
Tr
Tf
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
PAGE
11/15
:
Note 5. Definition of contrast ratio:
Contrast ratio is calculated with the following formula.
Contrast ratio (CR)=
Photodetector output when LCD is at “White” state
Photodetector output when LCD is at “Black” state
Note 6: Definition of brightness: This shall be measured at center of the screen.
Note 7: Driving conditions for CCFL : IL=4.3 mA,60KHz Frequency
Note 8: Definition of viewing angle:
Note 9: Definition of white uniformity:
White uniformity is defined as the following with thirteen measurements (A-M)
δw =
Maximum Luminance of thirteen points (brightness)
Minimum Luninance of thirteen points (brightness)
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
PAGE
:
12/15
D. Reliability test items(Note 1)
Test tem
High temperature storage
Test Condition
, 240Hrs
70
Low temperature storage
-20
High temperature & high
humidity operation
(No condensation)
High temperature operation
60
Low temperature operation
-10
Temperature cycling
(non-operation)
-20
judgement
Remark
1. Function OK
Note 1, 2
2. No serious image
quality degradation
1.Function OK
Note 1, 2
2.No serious image
quality degradation
, 240Hrs
, 90%RH, 240Hrs
40
Note 1, 2
1.Function OK
2.No serious image
quality degradation
1.Function OK
Note 1, 2
2.No serious image
quality degradation
, 240Hrs
, 240Hrs
1.Function OK
Note 1, 2
2.No serious image
quality degradation
~70
Note 1, 2
1.Function OK
2.No serious image
quality degradation
1H, 10mins, 1H, 5cycles
Electrostatic discharge
(non-operation)
150 pF,150 ,10kV,1 second, 9 position 1.Function OK
on the panel, 10 times each place
2.No serious image
quality degradation
Vibration
(non-operation)
Sweep:1G, 10HZ ~ 500HZ ~ 10HZ /2.5min 1.Function OK
Note 1, 2
2 hour for each direction X, Y, Z
2.No serious image
(6 Hrs in total)
quality degradation
Mechanical shock
(non-operation)
(50G, 11ms),
X,
once for each direction
Y,
Z
1.Function OK
2.No serious image
quality degradtion
Note 1, 2
Note 1: Evaluation should be tested after storage at room temperature for one hour.
Note 2: There should be no change which might affect the practical display function when the
display quality test is conducted under normal operating condition.
E. Display quality
The display quality of the color TFT-LCD module should be in compliance with the
AU Optronics OQC inspection standard.
F. Handling precaution
The Handling of the TFT-LCD should be in compliance with the AU Optronics handling
principle standard.
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
PAGE
:
13/15
G. Packing form :TBD
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
:
14/15
Fig.1 LCM outline dimensions
PAGE
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
www.data-modul.de
VIL
VIH
VIL
Hs
VIH
800,Y
X,599 X,600
Vs
DE
RGB
CLK
Hs
DE
RGB
Hs
Vs
Thf
Tvf
Tvpd
Thbl
invalid
Thw
The
Tvbl
Invalid
Tvw
Thb
Tve
X,2
Th
X,3
Tdh,Teh,Thh
Tds,Tes,Ths
Thd
Tvd
799,Y 800,Y
X,599 X,600
Tch
Tvf
Thf
Tcl
(1 pixel / clock)
invalid
Invalid
:
DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119
Fig.2 Timing chart
VIH
VIL
CLK
3,Y
VIH
VIL
2,Y
RGB,DE,Hs
1,Y
X,1
Th
Tv
PAGE
15/15
www.data-modul.de