Standard Name with Version AU OPTRONICS CORPORATION Spec. No.: xxxx-xxx-xxx Version: 1 Total pages: 4 Date: 2001-JUN-18 Tentative Module Specification for 10,4" TFT-LCD MODULES Model Name: B104SN01 Approved by Checked by Prepared by Quality Management Division / AU Optronics Croporation Customer Checked & Approved by AU copyright 2001, All rights reserved, Copying forbidden. 2001/07/14 AU Optronics Crop. 1/4 AU Confidential and Property. No Reproduction and Redistribution Allowed! Record of Revision Version Revise Date Page 1 26/Apr./2000 14 Content First draft. DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 www.data-modul.de PAGE 1/15 : Contents: P2 A. Physical specification B. Electrical specifications 1. Pin assignment 2. Absolute maximum ratings 3. Electrical characteristics b. Display color v.s. input data signals c. Input signal timing d. Display position e. Backlight driving conditions C. Optical specifications D. Reliability test items E. Display quality P12 P12 P10 P11 P9 P8 P7 P6 P5 P5 P4 … F. Handling precaution G. Packing form P3 P3 a. Typical operating conditions P13 Appendix: Fig.1 LCM outline dimensions Fig.2 Timing chart …………………… DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 P14 P15 www.data-modul.de PAGE : 2/15 A. Physical specifications NO. Item Specification 1 Display resolution(pixel) 800(H) 2 Active area(mm) 211.2(H) 3 Screen size(inch) 10.4(Diagonal) 4 Pixel pitch(mm) 0.264(H) 5 Color configuration R. G. B. Vertical stripe 6 Overall dimension(mm) 236(W) 7 Weight(g) 285 Remark 600(V) 158.4(V) 0.264(V) 174.3(H) 5.7(D) ( Max ) Note 1 10 Note 1: Refer to Fig. 1. DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 www.data-modul.de PAGE : 3/15 B. Electrical specifications 1.Pin assignment (1).Input signal interface Pin no Symbol Function 1 VCC +3.3 V power supply 2 VCC +3.3 V power supply 3 GND Ground 4 GND Ground 5 RxIN0- 6 RxIN0+ 7 GND 8 RxIN1- 9 RxIN1+ 10 GND 11 RxIN2- 12 RxIN2+ 13 GND Ground 14 CKIN- LVDS receiver signal clock 15 CKIN+ 16 GND 17 NC No Connection 18 NC No Connection 19 GND Ground 20 GND Ground Etc. LVDS receiver signal channel 0 Ground LVDS receiver signal channel 1 Ground LVDS receiver signal channel 2 Ground CN1 (20P) connector : HRS DF 19K-20P-1H or Compatible DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 www.data-modul.de PAGE : 4/15 (2) LVDS transmitter/receiver signal mapping Symbol Function TxIN0 R0 Red data (LSB) TxIN1 R1 Red data TxIN2 R2 Red data TxIN3 R3 Red data TxIN4 R4 Red data TxIN5 R5 Red data (MSB) TxIN6 G0 Green data (LSB) TxIN7 G1 Green data TxIN8 G2 Green data TxIN9 G3 Green data TxIN10 G4 Green data TxIN11 G5 Green data (MSB) TxIN12 B0 Blue data (LSB) TxIN13 B1 Blue data TxIN14 B2 Blue data TxIN15 B3 Blue data TxIN16 B4 Blue data TxIN17 B5 Blue data (MSB) TxIN18 Hs Horizontal sync TxIN19 Vs Vertical sync TxIN20 DE Data enable TxCLKIN CLK Clock 6 bit red display data 6 bit green display data 6 bits blue display data Dot clock 2. Absolute maximum ratings Parameter (GND = 0 V) Values Symbol Unit Power voltage VCC Min. -0.3 Input signal voltage VLH -0.3 VCC+0.3 Operating temperature Top -10 +60 Storage temperature TST -20 +70 Remark Max. 4 VDC At 25 VDC At 25 Note 1 Note 1 or Note 1:The relative humidity must not exceed 90% non-condensing at temperatures of 40 less. At temperatures greater than 40 , the wet bulb temperature must not exceed 39 . When operate at low temperatures, the brightness of CCFL will drop and the life time of CCFL will be reduced. Note 2:The unit should not be exposed to corrosive chemicals. DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 www.data-modul.de PAGE 5/15 : 3. Electrical characteristics a. Typical operating conditions Item Power supply voltage Internal logic Symbol Min. Typ. Max. Unit Input voltage VCC 3.0 3.3 3.6 V Current consumption IA 310 mArms IB 330 mArms Inrush current I RUSH - - 1500 Low voltage VIL 0 - 0.3 VCC High voltage VIH 0.7VCC - VCC VRP - - 100 Power ripple voltage Remark Note 1 mApeak Note 2 mVp-p Note 1:Effective value (mArms) at VCC = 3.3 V/25 . IA Black (0) 64 IB White Gray (7) 64 Black Vertical stripe line 64 Grayscale Note 2: Refer to the following power-on condition. 10% Sequence of Power-on/off and signal-on/off T3 Power T1 30ms T2 T5 Input signal 0 T1 70msec T2 70msec 300msec 300msec T5 T3 T4 10msec Apply the lamp voltage within the LCD operating range. When the backlight turns on before the LCD operation or the LCD turns off before the backlight turns off, the display may momentaily become abnormal. DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 www.data-modul.de PAGE 6/15 : Caution The above on/off sequence should be applied to avoid abnormal function in the display. In case of handling: Make sure to turn off the power when you plug the cable into the input connector or pull the cable out of the connector. b. Display color v.s. input data signals Display colors Basic colors Black Blue Red Magenta Green Cyan Yellow White Black Dark Red grayscale Data signal (0 : Low level, 1: High level) R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 0 0 0 1 1 0 0 1 1 0 0 1 0 0 1 1 0 0 1 1 0 1 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1 1 0 1 bright Red Black Dark Green grayscale bright Green Black Dark Blue grayscale bright Blue Note : Each basic color can be displayed in 64 gray scales using the 6 bit data signals. By combining the 18-bit data signals(R,G,B), the 262, 144 colors can be achieved on the display. DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 www.data-modul.de PAGE : 7/15 c. Input signal timing Timing diagrams of input signal are shown in Fig 2. (1). Timing characteristics of input signals (a) DE mode Item Symbol Min. Typ. Max. Unit Clock frequency Fck 38 40 42 MHz Horizontal blanking Thb1 50 256 500 Clk Vertical blanking Tvb1 10 28 150 Th Item Symbol Min. Typ. Max. Unit Clock frequency Fck 38 40 48 MHz Hsync period Th 850 1056 1300 Clk Hsync pulse width Thw 10 128 - Clk Hsync front porch Thf 15 40 - Clk Hsync back porch Thb 10 88 - Clk Hsync blanking Thb1 50 256 500 Clk Vsync period Tv 610 628 750 Th Vsync pulse width Tvw 1 4 - Th Vsync front porch Tvf 0 1 - Th Vsync blanking Tvb1 10 28 150 Th Hsync/Vsync phase shift Tvpd 2 320 - Clk Remark (b) HV mode Item Symbol Value Unit Remark Description Horizontal display start The 218 Clk After falling edge of Hsync, counting 218clk, then getting valid data from 219th clk’s data. Vertical display start 25 Th After falling edge of Vsync, counting 25 Th, then getting 26 th Th’s data. Tve DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 www.data-modul.de PAGE 8/15 : (2). The timing condition of LVDS Item The differential level Symbol Min. Typ. Max. Unit VID 0.1 - 0.6 V The common mode input voltage VIC VID 2 VID 2 - 2.4 V The input setup time tsu1 500 - - ps The input hold time th1 500 - - ps VID VIAP VID = VIAP - VIAM VIAM tsu1 th1 An 7 LCK d.Display position D( 1,1 ) D( 2,1 ) …… D( X,1 ) …… D( 799,1 ) D( 800,1 ) D( 1,2 ) .. . D( 2,2 ) …… D( X,2 ) .. . …… D( 799,2 ) .. . D( 800,2 ) .. . D( 1,Y ) .. . D( 2,Y ) D( 799,Y ) .. . D( 800,Y ) .. . D( 1,599 ) D( 1,600 ) …… …… …… …… …… D( X,Y ) .. . D( 2,599 ) …… D( X,599 ) …… D( 799,599) D( 800,599 ) D( 2,600 ) …… D( X,600 ) …… D( 799,600) …… DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 D( 800,600) www.data-modul.de PAGE : 9/15 e.Backlight driving conditions Parameter Symbol Min. Typ. Max. Unit Remark Lamp voltage VL - 488 - Vrms Note 1 Lamp current IL - 4.3 - mArms Note 1 Power consumption PL - 2.1 - W Note 2 Lamp starting voltage VS TBD Vrms TBD T=0 T=25 Frequency FL - 60 - KHZ Note 3 Lamp life time LL 10000 - - Hr Note 1, 4 Note 1: T= 25 , IL = 4.3 Note 2: Inverter should be designed with the characteristic of lamp. When you are designing the inverter, the output voltage of the inverter should comply with the following conditions. (1).The area under the positive and negative cycles of the waveform of the lamp current and lamp voltage should be area symmetric(the symmetric ratio should be larger than 90%). (2).There should not be any spikes in the waveform. (3).The waveform should be sine wave as possible. (4).Lamp current should not exceed the maximum value within the operating temperature (It is prohibited to over the maximum lamp current even if operated in the non-guaranteed temperature). When lamp current over the maximum value for a long time, it may cause fire. Therefore, it is recommend that the inverter should have the current limiter circuit. Note 3: Lamp frequency may produce interference with horizontal synchronous frequency and this may cause line flow on the display. Therefore lamp frequency shall be detached from the horizontal synchronous frequency and its harmonics as far as possible in order to avoid interference. In case using the inverter by PWM control, PWM frequency may interference with frame frequency. We suggest that PWM frequency is same as frame frequency. Note 4: Brightness to be decrease to the 50% of the initial value. Note 5: CN2 connector(backlight): JST BHSR-02VS-1 Mating connector: JST SM02B-BHSS-1-TB Pin no. Symbol Function Remark 1 H CCFL power supply(H.V.) Cable color: Pink 2 L CCFL power supply(GND) Cable color: White DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 www.data-modul.de PAGE 10/15 : C. Optical specifications ( Note 1, Note 2, Note 3 ) Item Symbol Condition Specification Min. Typ. Max. - 20 30 40 50 150 250 - 10 30 40 40 15 35 45 45 - 130 150 - - (0.31) - - (0.33) - Rx - - - Ry - - - Gx - - - Gy - - - Bx - - - By - - - W - - 1.8 Response time Rising time Falling time Tr Tf Contrast ratio CR =0 =0 Unit Remark ms Note 4 Note 5 Viewing angle Top Bottom Left Right CR YL Brightness Color chromaticity(CIE) White uniformity =0 deg. Note 8 nit Note 6,7 Wx =0 Wy 10 Note 9 Note 1: Ambient temperature = 25 . Note 2: To be measured in dark room after backlight warm up 30 minutes. Note 3: To be measured with a viewing cone of 1 by Topcon luminance meter BM-5A. Note 4: Definition of response time: The output signals of photodetector are measured when the input signals are changed from “Black” to “White” (falling time) and from “White” to “Black” (rising time), respectively. The response time interval between the 10% and 90% of amplitudes. Refer to figure as below. "Black" "White" "White" Signal(Relative value) 100% 90% 10% 0% Tr Tf DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 www.data-modul.de PAGE 11/15 : Note 5. Definition of contrast ratio: Contrast ratio is calculated with the following formula. Contrast ratio (CR)= Photodetector output when LCD is at “White” state Photodetector output when LCD is at “Black” state Note 6: Definition of brightness: This shall be measured at center of the screen. Note 7: Driving conditions for CCFL : IL=4.3 mA,60KHz Frequency Note 8: Definition of viewing angle: Note 9: Definition of white uniformity: White uniformity is defined as the following with thirteen measurements (A-M) δw = Maximum Luminance of thirteen points (brightness) Minimum Luninance of thirteen points (brightness) DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 www.data-modul.de PAGE : 12/15 D. Reliability test items(Note 1) Test tem High temperature storage Test Condition , 240Hrs 70 Low temperature storage -20 High temperature & high humidity operation (No condensation) High temperature operation 60 Low temperature operation -10 Temperature cycling (non-operation) -20 judgement Remark 1. Function OK Note 1, 2 2. No serious image quality degradation 1.Function OK Note 1, 2 2.No serious image quality degradation , 240Hrs , 90%RH, 240Hrs 40 Note 1, 2 1.Function OK 2.No serious image quality degradation 1.Function OK Note 1, 2 2.No serious image quality degradation , 240Hrs , 240Hrs 1.Function OK Note 1, 2 2.No serious image quality degradation ~70 Note 1, 2 1.Function OK 2.No serious image quality degradation 1H, 10mins, 1H, 5cycles Electrostatic discharge (non-operation) 150 pF,150 ,10kV,1 second, 9 position 1.Function OK on the panel, 10 times each place 2.No serious image quality degradation Vibration (non-operation) Sweep:1G, 10HZ ~ 500HZ ~ 10HZ /2.5min 1.Function OK Note 1, 2 2 hour for each direction X, Y, Z 2.No serious image (6 Hrs in total) quality degradation Mechanical shock (non-operation) (50G, 11ms), X, once for each direction Y, Z 1.Function OK 2.No serious image quality degradtion Note 1, 2 Note 1: Evaluation should be tested after storage at room temperature for one hour. Note 2: There should be no change which might affect the practical display function when the display quality test is conducted under normal operating condition. E. Display quality The display quality of the color TFT-LCD module should be in compliance with the AU Optronics OQC inspection standard. F. Handling precaution The Handling of the TFT-LCD should be in compliance with the AU Optronics handling principle standard. DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 www.data-modul.de PAGE : 13/15 G. Packing form :TBD DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 www.data-modul.de : 14/15 Fig.1 LCM outline dimensions PAGE DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 www.data-modul.de VIL VIH VIL Hs VIH 800,Y X,599 X,600 Vs DE RGB CLK Hs DE RGB Hs Vs Thf Tvf Tvpd Thbl invalid Thw The Tvbl Invalid Tvw Thb Tve X,2 Th X,3 Tdh,Teh,Thh Tds,Tes,Ths Thd Tvd 799,Y 800,Y X,599 X,600 Tch Tvf Thf Tcl (1 pixel / clock) invalid Invalid : DATA MODUL AG Landsberger Str. 322 80687 München Tel.: 089/ 56017-0 Fax 089/ 56017-119 Fig.2 Timing chart VIH VIL CLK 3,Y VIH VIL 2,Y RGB,DE,Hs 1,Y X,1 Th Tv PAGE 15/15 www.data-modul.de