ETC B39431-B3550-U310

SAW Components
Data Sheet B3550
SAW Components
B3550
Low-loss Filter
433,92 MHz
Data Sheet
Ceramic package QCC8C
Features
■ RF low-loss filter for remote control receivers
■ Package for Surface Mounted Technology
(SMT)
■ Balanced and unbalanced operation possible
Terminals
■ Ni, gold plated
typ. dimensions in mm, approx. weight 0,1 g
Pin configuration
1
2
5
6
4,8
Input Ground
Input
Output
Output Ground
Case - Ground
3,7
to be grounded
Type
Ordering code
B3550
B39431-B3550-U310
Marking and package
according to
C61157-A7-A56
Packing
according to
F61074-V8070-Z000
Electrostactic Sensitive Device (ESD)
Maximum ratings
Operable temperature range TA
Storage temperature range
DC voltage
Source power
Tstg
VDC
PS
–45/+120
˚C
–45/+120
0
10
˚C
V
dBm
2
source impedance 50 Ω
May 09, 2001
SAW Components
B3550
Low-loss Filter
433,92 MHz
Data Sheet
Characteristics
Reference temperature:
Terminating source impedance:
Terminating load impedance:
TA = 25 ˚C
ZS = 50 Ω and matching network t. b. d.
ZL = 50 Ω and matching network t. b. d.
min.
typ.
max.
—
433,96
—
Minimum insertion attenuation
αmin
433,80 ... 434,12 MHz
—
2,0
3,5
dB
Pass band (relative to αmin)
433,76 ... 434,16 MHz
433,74 ... 434,18 MHz
433,68 ... 434,24 MHz
—
—
—
1,0
1,0
1,5
2,0
3,0
6,0
dB
dB
dB
fC
Center frequency
(center frequency between 3 dB points)
Relative attenuation (relative to αmin)
10,00 ... 414,00
414,00 ... 428,00
428,00 ... 432,92
434,92 ... 442,00
442,00 ... 550,00
550,00 ...1000,00
MHz
αrel
MHz
MHz
MHz
MHz
MHz
MHz
Impedance for pass band matching 2)
Input: ZIN = RIN || CIN
Output: ZOUT = ROUT || COUT
45
40
15
10
35
45
50
45
20
15
40
50
—
—
—
—
—
—
dB
dB
dB
dB
dB
dB
—
270 || 2,67
250 || 3,20
—
Ω || pF
—
Ω || pF
—
Temperature coefficient of frequency 1)
TCf
—
–0,03
—
ppm/K2
Frequency inversion point
T0
10
—
30
°C
1)Temperature
dependence of fC: fC(TA) = fC(T0) (1 + TCf(TA – T0)2)
2)
Impedance for passband matching bases on an ideal, perfect matching of the SAW filter to
source- and to load impedance (here 50 Ohm). After the SAW filter is removed and input impedance into the input matching / output matching network is calculated.
The conjugate complex value of these characteristic impedances are the input and output impedances for flat passband. For more details, we refer to EPCOS application note #4.
3
May 09, 2001
SAW Components
B3550
Low-loss Filter
433,92 MHz
Data Sheet
Characteristics
TA = –45 ... 95˚C
ZS = 50 Ω and matching network
ZL = 50 Ω and matching network
Reference temperature:
Terminating source impedance:
Terminating load impedance:
min.
typ.
max.
—
433,92
—
MHz
Minimum insertion attenuation
αmin
433,80 ... 434,12 MHz
—
2,0
4,0
dB
Pass band (relative to αmin)
433,76 ... 434,08 MHz
433,74 ... 434,10 MHz
433,68 ... 434,16 MHz
—
—
—
1,0
1,0
1,5
2,0
3,0
6,0
dB
dB
dB
0,67
0,73
0,79
MHz
45
40
15
10
35
45
50
45
20
15
40
50
—
—
—
—
—
—
dB
dB
dB
dB
dB
dB
—
270 || 2,67
250 || 3,20
—
Ω || pF
—
Ω || pF
fC
Center frequency
(center frequency between 3 dB points)
Pass bandwidth
αrel≤ 3 dB
Relative attenuation (relative to αmin)
10,00 ... 414,00
414,00 ... 428,00
428,00 ... 432,84
434,92 ... 442,00
442,00 ... 550,00
550,00 ...1000,00
αrel
MHz
MHz
MHz
MHz
MHz
MHz
Impedance for pass band matching 2)
Input: ZIN = RIN || CIN
Output: ZOUT = ROUT || COUT
—
2)
Impedance for passband matching bases on an ideal, perfect matching of the SAW filter to
source- and to load impedance (here 50 Ohm). After the SAW filter is removed and input impedance into the input matching / output matching network is calculated.
The conjugate complex value of these characteristic impedances are the input and output impedances for flat passband. For more details, we refer to EPCOS application note #4.
4
May 09, 2001
SAW Components
B3550
Low-loss Filter
433,92 MHz
Data Sheet
Matching network to 50 Ω (element values depend on pcb layout and equivalent circuit)
Cp1 = 5,6 pF
Ls2 = 33 nH
Ls3 = 33 nH
Cp4 = 5,6 pF
Minimising the crosstalk
For a good ultimate rejection a low crosstalk is necessary. Low crosstalk can be realised with
a good RF layout. The major crosstalk mechanism is caused by the “ground-loop” problem.
Grounding loops are created if input-and output transducer GND are connected on the top-side
of the PCB and fed to the system grounding plane by a common via hole. To avoid the common
ground path, the ground pin of the input- and output transducer are fed to the system ground
plane (bottom PCB plane) by their own via hole. The transducers’ grounding pins should be
isolated from the upper grounding plane.
A common GND inductivity of 0.5nH degrades the ultimate rejection (crosstalk) by 20dB.
The optimised PCB layout, including matching network for transformation to 50 Ohm, is shown
here. In this PCB layout the grounding loops are minimised to realise good ultimate rejection.
Optimised PCB layout for SAW filters in QCC8C package, pinning 2,5 (top side, scale 1:1)
The bottom side is a copper plane (system ground area). The input and output grounding pins
are isolated and connected to the common ground by separated via holes.
For good contact of the upper grounding area with the lower side it is necessary to place
enough via holes.
5
May 09, 2001
SAW Components
B3550
Low-loss Filter
433,92 MHz
Data Sheet
Normalized frequency response
Normalized frequency response (wideband)
6
May 09, 2001
SAW Components
B3550
Low-loss Filter
433,92 MHz
Data Sheet
Published by EPCOS AG
Surface Acoustic Wave Components Division, SAW CE AE PD
P.O. Box 80 17 09, D-81617 München
 EPCOS AG 2001. All Rights Reserved.
As far as patents or other rights of third parties are concerned, liability is only assumed for components per se, not for applications, processes and circuits implemented within components or
assemblies.
The information describes the type of component and shall not be considered as assured
characteristics.
Terms of delivery and rights to change design reserved.
For questions on technology, prices and delivery please contact the sales offices of EPCOS AG or
the international representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our sales offices.
7
May 09, 2001