ETC DI-8B47J-03

DI-8B47 Linearized Thermocouple Input Modules
FEATURES
• Interfaces to Types J, K and T
• Linearizes Thermocouple Signal
• High Level Voltage Outputs
• 1500Vrms Transformer Isolation
• ANSI/IEEE C37.90.1
• Input Protected to 240VAC Continuous
• 120dB CMR
• 70dB NMR at 60Hz
• Low Drift with Ambient Temperature
• Accurate CJC -40°C to +85°C
• CSA, FM, and CE Certifications
Pending
• Mix and Match Module Types
DESCRIPTION
DI-8B modules are an optimal solution
for monitoring real-world process signals
and providing high level signals to a data
acquisition system. Each DI-8B47 module
isolates, filters, amplifies, and linearizes a
single channel of temperature input from
a thermocouple and provides an analog
voltage output.
Linearization is accomplished using a four
breakpoint piecewise linear approximation.
The DI-8B47 can interface to industry
standard thermocouple type J, K, and T and
has an output signal of 0V to +5V. Each
module is cold-junction compensated to
correct for parasitic thermocouples formed
by the thermocouple wire and screw terminals on the mounting backpanel. Upscale
open thermocouple detect is provided by
an internal pull-up resistor.
Signal filtering is accomplished with a
three-pole filter optimized for time and
frequency response which provides 70dB
of normal-mode-rejection at 60Hz. One
pole of this filter is on the field side of the
isolation barrier for anti-aliasing, and the
other two are on the system side.
SPECIFICATIONS
Typical at TA = +25ºC and +5V Power
DI-8B47
Input Range
Input Bias Current
Input Resistance
-0.1V to +0.5V
-25nA
Input Protection
Sensor Excitation Current
Lead Resistance Effect
CMV, Input to Output
Transient, Input to Output
CMR (50Hz or 60Hz)
NMR
Accuracy
Stability
Noise
Normal
Power Off
Overload
50MΩ
450kΩ
450kΩ
Continuous
Transient
240VAC
ANSI/IEEE C37.90.1
0.25mA
±0.02˚C/Ω¹
1500Vrms max
ANSI/IEEE C37.90.1
120dB
70dB at 60Hz
See Ordering Information on Page 2
Offset
Gain
Output, 100kHz
Bandwidth, -3dB
Response Time, 90% Span
Output Range
Output Protection
Transient
Cold Junction Compensation
Accuracy, 25ºC
Accuracy, -40ºC to +85ºC
Power Supply Voltage
Power Supply Current
Power Supply Sensitivity
Mechanical Dimensions
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
±20ppm/ºC
±75ppm/ºC
250µVrms
3Hz
150ms
0 to +5V
Continuous Short to Ground
ANSI/IEEE C37.90.1
±0.5ºC
±1.5ºC
+5VDC ±5%
30mA
±25ppm/%
1.11" × 1.65" × 0.40"
(28.1mm × 41.9mm × 10.2mm)
-40ºC to +85ºC
-40ºC to +85ºC
0 to 95% Noncondensing
A special input circuit on the DI-8B47
module provides protection against accidental connection of power-line voltages
up to 240VAC.
The modules are designed for installation
in Class I, Division 2 hazardous locations
and have a high level of immunity to environmental noise.
DATAQ Instruments, Inc. • 241 Springside Drive • Akron, Ohio 44333 • Tel: 330-668-1444 • Email: [email protected] • www.dataq.com
DI-8B47 Linearized Thermocouple Input Module
Block Diagram
Ordering Information
Model Number
TC Type
Input Range
DI-8B47J-01
J
0°C to +760°C (+32°F to +1400°F)
DI-8B47J-02
J
-100°C to +300°C (-148°F to +572°F)
DI-8B47J-03
J
0°C to +500°C (+32°F to +932°F)
DI-8B47J-12
J
-100°C to +760°C (-148°F to +1400°F)
DI-8B47K-04
K
0°C to +1000°C (+32°F to +1832°F)
DI-8B47K-05
K
0°C to +500°C (+32°F to +932°F)
DI-8B47K-13
K
-100°C to +1350°C (-148°F to +2462°F)
DI-8B47K-14
K
0°C to +1200°C (+32°F to +2192°F)
T
-100°C to +400°C (+32°F to +392°F)
DI-8B47T-06
T
0°C to +200°C (+32°F to +392°F)
DI-8B47T-07
* Includes conformity, hysteresis, and repeatability. Does not include CJC Accuracy.
Accuracy*
±0.24% ±1.82°C
±0.24% ±0.96°C
±0.21% ±1.05°C
±0.24% ±2.10°C
±0.24% ±2.40°C
±0.24% ±1.05°C
±0.24% ±3.60°C
±0.24% ±2.88°C
±0.48% ±2.40°C
±0.39% ±0.75°C
DATAQ
R
INSTRUMENTS
241 Springside Drive
Akron, Ohio 44333
330-668-1444
Data Acquisition Product Links
(click on text to jump to page)
Data Acquisition | Data Logger | Chart Recorder | Thermocouple | Oscilloscope
The information on this data sheet is subject to change without notice.
DATAQ and the DATAQ logo are registered trademarks of DATAQ Instruments, Inc. All rights reserved. Copyright © 2005 DATAQ Instruments, Inc.