34200B

34200B
Precision Aligned ±10 g to ±70 g
Triaxial Accelerometer
Superior Zero g Bias Stability
Technical Data*
Features and Benefits
Precision Alignment
Each axis of the Measurement Specialties 34200B is precision aligned to
minimize errors due to axis misalignment or transverse sensitivity.
High Accuracy and Linearity over Wide Temperature Range
The voltage output for each axis of the 34200B is directly proportional to the
acceleration along that axis. Each DC-coupled output is fully scaled,
referenced, and temperature compensafted over the entire -40 to +85°C
temperature range. Accuracy is improved by minimizing variations due to
temperature and aging effects, resulting in a sensor that is more stable over
temperature than piezoelectric or piezoresistive devices.
Calibration Certificate
Each 34200B is supplied with a calibration certificate listing sensitivity and
offset, as well as the on-axis and transverse alignment parameters needed
to ensure rapid and efficient system implementation. The alignment data
can be used to compensate the measured values to achieve an even higher
level of sensor accuracy.
Self-Test on Digital Command
A TTL-compatible self-test low input causes a simulated acceleration to be
injected into all three sensors to verify channel integrity.
Small Size
Complete conditioned triaxial accelerometer in less than a cubic inch.
­ uilt-In Power Supply Regulation
B
Unregulated DC power from +8.5 to +36 volts is all that is required to
measure accelerations on all axes.
Suitable for Harsh Environments
The 34200B is robust and can be used in harsh environments. The unit will
survive 4000 g powered or unpowered.
Warranty
These Measurement Specialties accelerometers come with a three-year
factory warranty.
34200B Analog Rate Gyro
precisionsensors.meas-spec.com Precisely Measure
Real -World Accelerations
Measurement Specialties’ 34200B
accelerometer has each mutually orthogonal axis precisely aligned within
0.5 degree of the theoretical ideal. This
provides the accuracy required by most
measurement applications without any
compensation. Critical applications
requiring higher accuracy can use the
alignment data provided on the calibration certificate to compensate for any
small residual error.
Choose the bandwidth and range
options best suited for your application
to measure ±10 g, ±15 g, ±20 g, ±25 g,
±30 g, ±35 g, ±40 g, ±50 g, or ±70 g
accelerations on each of three axes.
Each axial sensor has been tested over
the -40 to +85°C temperature range and
has a nominal full scale output swing
of ±2 volts. The zero g output level is
nominally +2.5 volts. Precise values for
each axis are available on the included
calibration certificate.
2236 N. Cleveland-Massillon Road
Akron OH 44333 PH : 330-659-3312 8/5/2013
www.meas-spec.com
Specifications for 34200B - improved specifications available upon request
Ta = Tmin to Tmax; 8.5 ≤ Vs ≤ 36 V; Acceleration = 0 g unless otherwise noted; within one year of calibration.
Parameter
Min
Units
Conditions/Notes
±70
g
On each axis. Must specify via Option Rnnn
Sensitivity
At 25°C, Option R050
Drift Tmin to Tmax
38†
±0.5
mV/g
%
Zero g Bias Level
At 25°C
Drift Tmin to Tmax
2.5
±60
V
mg
Alignment
Deviation from Ideal Axes
±0.2
Transverse Sensitivity
±0.25
Nonlinearity
0.2
Precise values on cal certificate
Percent of sensitivity at 25°C
Precise values on cal certificate
At 1.25°C/min temperature rate of change
Precise values on cal certificate
Can be compensated if required
±0.5
degrees
2
% FSR
400††
Hz
3.5
3.0
3.0
mg/√Hz
mg/√Hz
mg/√Hz
%
Inherent sensor error, excluding misalignment
Best fit straight line
Frequency Response
Noise Density
Option R070
Option R050, R040
Option R035, R030, R025, R020, R015, R010
Self-Test Input Impedance
10
Temperature Sensor
Sensitivity
0°C Bias Level
Outputs
Output Voltage Swing
Capacitive Drive Capability
0.25
1000
4.75
V
pF
Iout = ±0.5 mA
Power Supply (Vs)
Input Voltage Limits
Input Voltage - Operating
Input Current
Rejection Ratio
-20
+8.5
15
>120
+38
+36
20
V
V
mA
dB
-20 V continuous
Temperature Range (Ta)
-40
+85
°C
Mass
Shock Survival
-4000
linearly with range option Rnnn
††Per
0
1.8
1.4
1.1
2
3
3
1
2
6.45
509
1
1
0.945 0.354
Two 3 mm
[24,00] [9,0]
x 0.5 mm
threaded holes
are provided
on each of
three orthogonal faces for
mounting.
34200B Analog Rate Gyro
precisionsensors.meas-spec.com Precise values on cal certificate
g
Any axis for 0.5 ms, powered or unpowered
Connections
T004
2
Pin
Signal
Wire
0.354
[9,0]
No load, quiescent
DC
Option Bnnn; See Ordering Information
3
0.945
[24,00]
Accuracy ±1°C
grams
+4000
10 Hz to 400 Hz
Pullup. Logic "1"≥ 3.5 V, Logic "0"≤ 1.5 V
mV/°C
mV
35
1.115
[28,30]
0.295
[7,50]
3 mm x 0,5 mm Thread
3,5 mm [0.138] Deep
0.295
[7,50]
(6) Mounting Holes
on 3 sides
Upper cutoff per Option Bnnn, -3 dB pt ±10%
kΩ
Mechanical
Max
±10
†Scale
Typical
Range
Measurement Full Scale
Dimensions in inches [mm],
identical for each view where
applicable.
1
A1+
Brown
2
Signal-
Red
3
4
5
A2+ +5VOut A3+
Orange Yellow Green
6
7
8
T+ Self Test-L +Vs
Blue
Violet
Grey
9
Gnd
White
Ordering Information
34200B - R050 - B400 - T004
Cable to 9-pin male
D-Shell connector
3
1
2
Shown with 34170B
mounting adapter
(sold separately)
Instrument
Range
R070 : ±70 g
R050 : ±50 g
R040 : ±40 g
R035 : ±35 g
R030 : ±30 g
R025 : ±25 g
R020 : ±20 g
R015 : ±15 g
R010 : ±10 g
2236 N. Cleveland-Massillon Road
Akron OH 44333 PH : 330-659-3312 Termination
T004 : 4 ft. cable with DB9M
T000 : PCB mount (Not shown, Call SI)
Tnnn : Custom length, nnn ft. (Call SI)
Bandwidth
B400 : 0 to 400 Hz
B380 : 0 to 380 Hz
B208 : 0 to 208 Hz
B142 : 0 to 142 Hz
B094 : 0 to 94 Hz
B066 : 0 to 66 Hz
B031 : 0 to 31 Hz
B6.6 : 0 to 6.6 Hz
8/5/2013
www.meas-spec.com