PMR205 • RC unit, metallized paper with integrated resistor • 0.1 – 1.0 µF, 22 - 680 Ω, 125 VAC, +85 °C • Small dimensions • High dU/dt capability. • Excellent self-healing properties. Ensures long life even when subjected to frequent overvoltages. • Self-extinguishing encapsulation. • Good resistance to ionisation due to impregnated dielectric. • The impregnated paper ensures excellent stability giving outstanding reliability properties, especially in applications having continuous operation. L B RC unit for use in DC and AC applications for: – contact protection – interference suppression of contacts – transient suppression Single layer metallized paper. Encapsulated and impregnated in self-extinguishing material meeting the requirements of UL 94V-0. The resistance in the metal layer is utilized as series resistance, integrated resistor. H CONSTRUCTION p ± 0.5 ∅ 0.8 l TYPICAL APPLICATIONS TECHNICAL DATA R Rated voltage 250 VDC, 125 VAC Capacitance range Capacitance tolerance 0.1–1.0 µF ± 20% Resistance range Resistance tolerance 22 – 680 Ω ± 30% Peak pulse voltage 375 V Temperature range Climatic category –40 to +85°C 40/085/56/B Series resistance The series resistance is defined at 1 kHz for RC ≥ 50 µs and at 100 kHz for RC < 50 µs. C l: standard: 30 +5/-0 mm (code R30) option: short leads, tolerance +0/-1 mm (standard 6 mm, code R06) Other lead lengths on request. Pmax W 0.5 1 2 50 60 3 4 5 Insulation resistance ≥ 3000 MΩ for C ≤ 0.33 µF ≥ 1000 s for C > 0.33 µF Measured at 100 VDC after 60 s, +23°C 0 Power ratings Dimensions 1 2 2 3 4 5 B = 5.2 B = 7.3 B = 7.8 B = 7.6 B = 9.0 B = 11.3 70 80 ENVIRONMENTAL TEST DATA Vibration IEC 60068-2-6, Test Fc Bump IEC 60068-2-29, Test Eb 4000 bumps at 390 m/s2 No visible damage, No open or short circuit Solderability IEC 60068-2-20, Test Ta Solder globule method Wetting time < 1 s Humidity IEC 60068-2-3, Test Ca +40°C and 90 – 95% R.H. 56 days 194 3 directions at 2 hour each 10 – 500 Hz at 0.75 mm or 98 m/s2 85 °C Maximum allowable power dissipation vs ambient temperature and case sizes. The average losses may reach 0.5 W provided the surface temperature does not exceed + 85°C. For maximum permitted power dissipation v temperature, see derating curves. Curve Tamb 40 No visible damage, No open or short circuit PMR205 ARTICLE TABLE Capacitance Resis- Max dimensions in mm tance Quantity per package R30 R06 reel taped pcs pcs pcs Weight µF Ω B H L p 0.10 0.10 0.10 0.10 33 47 100 220 5.2 5.2 5.2 5.2 10.5 10.5 10.5 10.5 18.5 18.5 18.5 18.5 15.2 15.2 15.2 15.2 500 500 500 500 1000 1000 1000 1000 600 600 600 600 1.7 1.7 1.7 1.7 PMR205AB6100M033R30 PMR205AB6100M047R30 PMR205AB6100M100R30 PMR205AB6100M220R30 0.15 0.15 68 100 5.2 5.2 10.5 10.5 18.5 18.5 15.2 15.2 500 500 1000 1000 600 600 1.7 1.7 PMR205AB6150M068R30 PMR205AB6150M100R30 0.22 0.22 0.22 0.22 0.22 47 100 220 330 470 7.3 7.3 7.3 7.3 7.3 13.0 13.0 13.0 13.0 13.0 19.0 19.0 19.0 19.0 19.0 15.2 15.2 15.2 15.2 15.2 400 400 400 400 400 800 800 800 800 800 400 400 400 400 400 3.0 3.0 3.0 3.0 3.0 PMR205AB6220M047R30 PMR205AB6220M100R30 PMR205AB6220M220R30 PMR205AB6220M330R30 PMR205AB6220M470R30 0.25 0.25 0.25 200 350 600 7.3 7.3 7.3 13.0 13.0 13.0 19.0 19.0 19.0 15.2 15.2 15.2 400 400 400 800 800 800 400 400 400 3.0 3.0 3.0 PMR205AB6250M200R30 PMR205AB6250M350R30 PMR205AB6250M600R30 0.33 47 7.8 13.5 18.5 15.2 400 800 400 3.3 PMR205AB6330M047R30 0.47 0.47 0.47 0.47 0.47 0.47 0.47 0.47 22 33 47 68 100 150 220 330 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.3 250 250 250 250 250 250 250 250 1500 1500 1500 1500 1500 1500 1500 1500 250 250 250 250 250 250 250 250 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 PMR205AC6470M022R30 PMR205AC6470M033R30 PMR205AC6470M047R30 PMR205AC6470M068R30 PMR205AC6470M100R30 PMR205AC6470M150R30 PMR205AC6470M220R30 PMR205AC6470M330R30 0.47 470 9.0 15.0 24.0 20.3 200 1200 250 5.0 PMR205AC6470M470R30 0.47 680 11.3 16.5 24.0 20.3 150 1000 180 7.0 PMR205AC6470M680R30 1.0 33 10.6 16.1 30.5 25.4 150 1000 8.6 PMR205AE7100M033R30 1.0 1.0 1.0 1.0 1.0 47 68 100 150 220 11.3 11.3 11.3 11.3 11.3 16.5 16.5 16.5 16.5 16.5 24.0 24.0 24.0 24.0 24.0 20.3 20.3 20.3 20.3 20.3 150 150 150 150 150 1000 1000 1000 1000 1000 7.0 7.0 7.0 7.0 7.0 PMR205AC7100M047R30 PMR205AC7100M068R30 PMR205AC7100M100R30 PMR205AC7100M150R30 PMR205AC7100M220R30 g ORDERING INFORMATION The article code for the standard part is given in the article table. For other options, see page 21. PACKING RC units in standard design (lead length 30 mm) and with L < 24 mm and lead length 5 or 6 mm are packed bulk in a box with dimensions 245 x 145 x 80 mm. Quantity/ package as per article table. RC units with L ≥ 24 mm and lead length 5 or 6 mm are packed on trays piled in a box with dimensions 300 x 260 x 195 mm. Article code MARKING • • • • • • • RIFA RIFA article code RC unit Rated capacitance and resistance Rated voltage MP, for metallized paper Climatic category according to IEC 60068-1, appendix A • Passive flammability class • Circuit diagram • Manufacturing code (year, month) Reels with taped capacitors are packed 10 in a box with dimensions 370 x 370 x 560 mm. The standard quantity/reel is for 360 mm reel. If 500 mm reel is required, it must be specified when ordering and the quantity is 2 x the given quantity. 195