ETC WU106

DC/DC Converters
10/15 Watts
XPiQ inc.
WU Series
Intelligent Design Quality Product
•
4:1 Input Range
•
Isolated Outputs
•
Efficiency to 84%
•
Overvoltage Protection
•
Input π Filter
•
Short Circuit Protected
•
Fully Regulated Outputs
Specification
All specifications are typical at nominal line, full load and 25°C
General
Input
Input Voltage Range
Input Filter
•
•
See Table
π Network
Output
Voltage Accuracy
Line Regulation
(Full Input Range)
Load Regulation
(1/4-full load)
Ripple & Noise
(DC-20 MHz)
Temperature
Coefficient
Short Circuit
Protection
•
•
±1.0% max.
±1.0% max.
•
±1.0% max.
•
1% of Vout max.
•
±0.02%/°C max.
•
Indefinite
Switching
Frequency
Efficiency
Isolation
(Input-Output)
•
100 kHz
•
•
See Table
500 VDC
(1000 Mohm/80pF)
Environmental
Operating
Temperature
Storage
Temperature
•
-25°C to +71°C
•
-55°C to 125°C
•
•
25
www.XP-iQ.com
PH: 508 429.9883
FAX: 800 226.2100
Email: [email protected]
Holliston, MA 01746 USA
OUTPUT VOLTAGE & CURRENT RATINGS
Model
Input
Voltage
WU100
WU101
WU102
WU103
WU104
WU105
WU106
WU200
WU201
WU202
WU203
WU204
WU205
WU206
WU207
WU208
WU209
WU300
WU301
WU302
WU303
WU304
WU305
WU306
WU307
WU308
WU309
WU400
4.5-6.0
4.5-6.0
4.5-6.0
4.5-6.0
4.5-6.0
4.5-6.0
4.5-6.0
9.0-18.0
9.0-36.0
9.0-36.0
9.0-36.0
9.0-36.0
9.0-36.0
9.0-36.0
9.0-36.0
9.0-36.0
9.0-36.0
18.0-36.0
20.0-72.0
20.0-72.0
20.0-72.0
20.0-72.0
20.0-72.0
20.0-72.0
20.0-72.0
20.0-72.0
20.0-72.0
36.0-72.0
Output
Voltage
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
5.0/±12.0
5.0/±15
5.0/+12.0/–5.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
5.0/±12.0
5.0/±15.0
5.0/+12.0/–5.0
3.3
WU
Output
Current
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
3000
2000
800
667
±1000
±400
±333
3000
3000
1250
1000
±1500
±625
±500
1500/±310
1500/±250
1500/310/500
3000
3000
1250
1000
±1500
±625
±500
1500/±310
1500/±250
1500/310/500
3000
Input Current
No Load
Full Load
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
10
10
10
10
10
10
10
10
30
30
30
30
30
30
20
20
20
10
20
20
20
20
20
20
15
15
15
10
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
2470
2620
2520
2510
2620
2520
2510
1030
1560
1540
1525
1560
1540
1520
1576
1582
1447
500
760
750
745
760
750
745
778
781
715
245
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
%
Efficiency
80
76
76
80
76
76
79
80
80
81
82
80
81
82
79
79
79
83
82
83
84
82
83
84
80
80
80
84
Note: Nominal Input Voltage 5,12, 24 or 48 VDC
Mechanical Details
SINGLE/DUAL OUTPUT
PIN
SINGLE
DUAL
TRIPLE
1
2
3
4
5
6
7
+ Input
- Input
+ Output
Trim
- Output
Disable
-
+ Input
- Input
+ Output
Common
- Output
Disable
-
Disable
- Input
+ Input
- Output
Common
5 VDC Output
+ Output
REMOTE ON/OFF CONTROL
Logic Compatibility ................CMOS or Open Collector TTL
Ec - ON,........................................>+5.5 VDC or Open Circuit
Ec - OFF, ..................................................................<1.8 VDC
Shutdown Idle Current ..................................................10 mA
Input Resistance ......................(Ein 0 VDC to 9 VDC)100KOhm
Control Common ........................Referenced to input Minus
EXTERNAL OUTPUT TRIMMING
Output may optionally be externally trimmed (±5%)
with a fixed resistor or an external trimpot as shown.
Dimensions in inches (mm).
NOTES:
1. Voltage accuracy on 3VDC and triple outputs ±3% Max.
Single outputs can be trimmed ±5%.
2. Load regulation ±2% for dual and triple outputs.
3. Triple outputs require minimum of 10% load for rated performance.
4. Remote on/off standard on triple output units, add
suffix “E” to part number for option on single and dual output units.
www.XP-iQ.com
TRIPLE OUTPUT
PH: 508 429.9883
FAX: 800 226.2100
Email: [email protected]
Holliston, MA 01746 USA
26