833H Relay FEATURES • • • • Sub-Miniature,7-10 amps UL,CSA & TUV Flux-tight or Sealed Low cost,medium-duty applications ORDERING INFORMATION 833H 1C C 12VDC Coil voltage Type Enclosure C - Flux-tight S - Sealed Contact form 1A:SPNO 1B:SPNC 1C: SPDT SAFETY APPROVAL Certified File No. UL E74321 CUR E74321 TUV R9754206 SAFETY APPROVAL RATING UL 10A 125VAC 7A 277VAC/30VDC CUR 10A 125VAC 7A 277VAC/30VDC TUV 7A 250V~(AC) 12A 125V~(AC) 7A 30V =(DC) COIL DATA (DC) Rated voltage (V) 3 4 5 6 9 12 24 48 Rated current ± 10 % at 25º (mA) 120 91 72 60 40 30 15 9.4 Coil resistance ± 10 % at 25º ( ) 25 44 70 100 225 400 1600 5,120 Max. continuous Pick up voltage voltage (Max) 25ºC 25ºC 130% of rated voltage 75% of rated voltage Drop out voltage (Min) 25ºC Power consumption at rated voltage 10% of rated voltage approx. 0.36W approx. 0.45W SPECIFICATION Contact resistance Operate time Release time Insulation resistance Dielectric strength 100m Max.(initial value) 10ms 5ms 100M Min.(DC 500V) Between open contact Between contact and coil Vibration resistance Operating extremes Damage limits Shock resistance Operating extremes Distributor: Electro-Stock, Inc. www.electrostock.com 800-876-1152 AC 750V, 50/60Hz 1 min. AC 1500V,50/60Hz 1min. 10~50Hz,amplitude 1.5mm >10~50Hz,amplitude 1.5mm >10G Fax: 630-876-1166 [email protected] Relay 833H SPECIFICATION Shock resistance Life expectancy Operating extremes Damage limits Mechanical Electrical Operating temperature Weight >10G >100G >10,000,000 operations (frequency 18,000 operations/hr) >100,000 operations (frequency 1,200 operations/hr) -30º ~ +70ºC (no freezing) Approx.10g OUTLINE DIMENSIONS WIRING DIAGRAM PC BOARD LAYOUT 19 Distributor: Electro-Stock, Inc. www.electrostock.com 800-876-1152 Fax: 630-876-1166 [email protected]