ETC HMJ5-PCB

HMJ5
The Communications Edge ™
High Dynamic Range FET Mixer
Product Features
• +35 dBm IIP3
• No external matching element
•
•
•
•
•
•
Functional Diagram
Product Description
Required
RF 40-1000 MHz
LO 30-900 MHz
IF 5-250 MHz
+17 dBm LO Drive Level
+3V at 35 mA DC Power Supply
Low Cost Surface Mount J-Lead
Package
The HMJ5 is a high dynamic range, GaAs FET
mixer. This active FET mixer realizes a typical
third order intercept point of +35 dBm at an
LO drive level of +17 dBm. The HMJ5 comes
in a low cost, J-Lead package. Typical applications include frequency up/down conversion,
modulation and demodulation for receivers and
transmitters used in communications systems.
22 21 2019 18171615 1413 12
1 2 3 4 5 6 7 8 9 10 11
D• e
E
T
DA O Driv
P
U
L
•
dBm
7
1
+
Function Pin No. Function Pin No.
Ground
1
Ground
12
IF
2
LO
13
Ground
3-9
Ground 14-20
+3V DC
10
RF
21
Ground
11
Ground
22
Specifications
Parameter
Frequency Range:
RF
LO
IF
SSB Conversion Loss
SSB Noise Figure
Isolation:
LO to RF
LO to IF
IIP3
Return Loss:
RF Port
LO Port
IF Port
Input P1dB
LO Drive Level
DC Current at +3V Bias
Units
Minimum
MHz
MHz
MHz
dB
dB
40
30
5
dB
dB
dBm
20
24
31
Typical
7.5
9.5
dB
dB
dB
dBm
dBm
mA
Maximum
Condition
1000
900
250
9.0
28
30
35
RF = 900 MHz (0 dBm)
11.7
6.0
10.9
23
17
35
60
Notes:
1. RF = 905 MHz (-10 dBm) LO 900 (+17 dB) IF = 5 at 25°C.
2. Measured in a 50-ohm system with nominal LO drive in a downconverter application only, unless otherwise specified.
3. LO frequency must be separated from IF frequency by a minimum of 2 MHz (i.e., |FLO - FIF| ≥ 2 MHz).
Absolute Maximum Ratings
Parameter
Operating Case Temperature
Storage Temperature
Maximum Input Power
Ordering Information
Rating
-40 to +85°C
-65 to +100°C
+25 dBm
Part No.
Description
HMJ5
High Dynamic Range FET Mixer
(Available in tape and reel)
Fully Assembled Application Circuit
HMJ5-PCB
1. Operation of this device above any of these parameters may cause permanent damage.
2. Total sum of LO port and RF port power should not exceed 25 dBm.
WJ Communications, Inc. • Phone: 1-800-WJ1-4401 • FAX: 408-433-5649 • e-mail: [email protected] • Web site: www.wj.com
September 2000
HMJ5
Performance Charts
IP3 vs. RF Frequency
Conversion Loss vs. RF Frequency
50
Conversion Loss (dB)
9
IP3 (dBm)
45
40
IF = 250 MHz
35
8
IF = 250 MHz
7
IF = 5 MHz
IF = 100 MHz
6
IF = 5 MHz
30
5
0
300
600
RF Frequency (MHz)
0
900
200
400
600
800
1000
RF Frequency (MHz)
LO to RF Isolation
LO to IF Isolation
60
60
L-I Isolation (dB)
L-R Isolation (dB)
50
40
30
50
40
20
10
30
0
300
600
LO Frequency (MHz)
0
900
600
900
RF Frequency (MHz)
LO Port Return Loss vs. LO Freq
RF Port Return Loss
IF Return Loss vs. IF Frequency
5
5
10
10
10
15
20
Return Loss (dB)
5
LO Return Loss
Return Loss (dB)
300
15
20
LO = 750 MHz
LO = 550 MHz
LO = 850 MHz
15
LO = 450 MHz
LO = 350 MHz
20
LO = 250 MHz
25
25
0
200
400
600
RF Frequency (MHz)
800
1000
25
0
200
400
600
LO Frequency (MHz)
800
1000
50
100
150
IF Frequency (MHz)
WJ Communications, Inc. • Phone: 1-800-WJ1-4401 • FAX: 408-433-5649 • e-mail: [email protected] • Web site: www.wj.com
200
250
September 2000
HMJ5
Outline Drawing
Land Pattern
Specifications and information are subject to change without notice.
Mounting Configuration
Caution! ESD sensitive device.
WJ Communications, Inc. • Phone: 1-800-WJ1-4401 • FAX: 408-433-5649 • e-mail: [email protected] • Web site: www.wj.com