ETC TC9204M

TC9204M
Preliminary Data Sheet
4-Port 10/100/1000 Smart Ethernet Switch
This feature allows improved
multimedia applications.
Features
Stand Alone Switch On A Chip
4 Ethernet 10/100/1000 ports
MII/GMII interface for all ports
Four Classes of Service (CoS) selectable for
each port and/or checked via IP Header and
802.1Q VLAN Tag
Support 4 port-based VLANs
Maximum throughput (wire speed), non
head-of-line blocking architecture
Embedded SSRAM for packet buffer /
address table, no external memory required
8K MAC address table
25 MHz crystal input only
Each port is configurable to 10 full/half duplex,
100 full/half duplex and 1000 full duplex mode
Flow-control ability is able to set for both full
and half duplex mode
Broadcast throttling
Port Mirroring
Serial EEPROM Interface, EEPROM is optional
MDIO master for PHY configuration / polling
0.18 micron technology
2.0V and 3.3V dual voltage power supply
Packaged in PQFP 208
for
The chip embeds IEEE 802.3 MAC functions for
each port and these functions support full and half
duplex modes for both 10 and 100 Mbits/s data
rates and full duplex for 1000 Mbit/s. Each port
includes dedicated receive and transmit FIFOs
with necessary logic to implement flow control for
both full and half duplex modes. TC9204M uses
IEEE 802.3x frame based flow control for full
duplex and backpressure for half duplex.
TC9204M handles an 8K address-lookup table
with searching, self-learning, and automatic aging
at very high speed and excellent address space
coverage. Forwarding rules are implemented
according to IEEE 802.1D specifications. Filtering
capabilities for bad packets and packets with
Reserved Group Address DA are also provided.
A port mirror feature, optionally including bad frames,
can be used for debugging network problems.
The pin configuration interface comprises 40
configurations, which are shared with GMII output
pins by latching the configuration data during
reset. An external EEPROM device can also be
used to configure the TC9204M at power-up. With
reference to pin configuration interface, the
EEPROM extends the chip’s configuration
capability with new features and enables a
jumper-less configuration mode using a parallel
interface for reprogramming. A virtual internal
EEPROM mode is also provided to enable the
use of the programming interface in the absence
of external EEPROM. TC9204M can make
effective use by most of its features using only the
pin configuration interface.
General Description
TC9204M is a fully integrated 4-Port 10/100/1000
smart Ethernet switch controller designed for low
cost and high performance solutions. The chip
embeds necessary SSRAM for packet buffering
and MAC address table. It provides MII / GMII
interface for all ports.
A store-and-forward switching method using a
non-blocking architecture is implemented within
TC9204M to improve the availability and
bandwidth. The chip embeds SSRAM packet
buffer, which it supports normal and priority
queues for each transmission port.
TC9204M includes a physical layer configuration /
polling entity, which it is use to configure the phy
functions and to monitor the physical layer
transceiver’s speed, duplex mode, link status and
full duplex flow control ability for each port. The
chip provides four modes for phy configurations,
which these modes include auto-negotiation
disable procedure for 10/100 speed modes. The
phy configuration information is stored in
EEPROM setting.
TC9204M provides evolved CoS with four levels
of priority. The priority can be checked via layer 2
(802.1Q VLAN Tagging) and/or layer 3 (IP Header
TOS bits) packets. Port based priority is also
provided to ensure transmission with precedence
for all packets incoming from selected port(s).
Confidential.
Copyright © 2003, IC Plus Corp.
support
1/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
The chip requires a 25 MHz system clock, dual
2.0V and 3.3V power supply and it is packaged in
208 PQFP.
Block Diagram
EEprom Interface
MDIO
interface
Configuration
Register
Rx FIFO
4 GMII/MII
RX/TX MAC's
Control
From RX MAC
Queue
Management
Tx FIFO
External PHY's
To TX MAC
Address
LoockUp
&
Resolution
Unit
Internal
SSRAM
Buffer
TC9204M
Block Diagram
Confidential.
Copyright © 2003, IC Plus Corp.
Memory
Interface
&
Arbiter
2/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
Table Of Contents
Features ..............................................................................................................................................................1
General Description ............................................................................................................................................1
Block Diagram.....................................................................................................................................................2
Table Of Contents ...............................................................................................................................................3
Revision History ..................................................................................................................................................4
Pins Placement...................................................................................................................................................5
1 Pin Listing (PQFP208) ................................................................................................................................6
2 Ethernet Media Access Controller ............................................................................................................14
2.1
Receive MAC ..................................................................................................................... 14
2.2
Transmit MAC .................................................................................................................... 15
3 MAC Address Handling.............................................................................................................................16
4 Queue Management.................................................................................................................................16
5 Classes of Service ....................................................................................................................................17
6 Flow Control ..............................................................................................................................................19
7 Broadcast Throttling ..................................................................................................................................21
8 Port Mirroring.............................................................................................................................................21
9 Physical Layer Configuration / Polling......................................................................................................22
10 EEPROM Interface ...................................................................................................................................23
10.1 Reprogramming the EEPROM for reconfiguration ............................................................ 23
10.2 EEPROM Address Map ..................................................................................................... 24
10.3 Register Description........................................................................................................... 26
10.3.1
Validation Register ................................................................................................ 26
10.3.2
Port [X] Configuration Register ............................................................................. 28
10.3.3
Port [X] IFG Configuration Register ................................................................... 30
10.3.4
Flow Control Register ........................................................................................... 31
10.3.5
Backpressure Time Value Register....................................................................... 33
10.3.6
Flow Control Port Base Address Register ............................................................ 33
10.3.7
Broadcast Configuration Register......................................................................... 34
10.3.8
IP Priority Mapping Register ................................................................................. 35
10.3.9
VLAN Priority Mapping Register ........................................................................... 36
10.3.10
CoS Bandwidth Register....................................................................................... 37
10.3.11
Reserved Register ................................................................................................ 37
CoS Configuration Register .................................................................................. 38
10.3.12
10.3.13
Port Mirroring Register.......................................................................................... 39
General Configuration Register ............................................................................ 40
10.3.14
10.3.15
Port VLAN Enable Register .................................................................................. 41
VLAN [Y] Register................................................................................................. 41
10.3.16
10.4 Writing / Reading PHY management registers via EEPROM interface............................. 42
10.4.1
Data Write Register............................................................................................... 42
10.4.2
Physical Layer Device Address Register .............................................................. 42
10.4.3
Physical Layer’s Register Address Register......................................................... 43
10.4.4
IO Status Control Register.................................................................................. 43
10.4.5
Data Read Register .............................................................................................. 44
11 Timing Requirements................................................................................................................................45
11.1
GMII / MII Receive Timing Requirements .......................................................................... 45
11.2
GMII / MII Transmit Timing................................................................................................. 45
11.3
PHY Management (MDIO) Timing ..................................................................................... 46
11.4
EEPROM Timing................................................................................................................ 47
12 Electrical Specifications ............................................................................................................................48
12.1 ABSOLUTE MAXIMUM RATINGS..................................................................................... 48
12.2 RECOMMENDED OPERATING CONDITIONS ................................................................ 48
Confidential.
Copyright © 2003, IC Plus Corp.
3/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
12.3 DC CHARACTERISTICS................................................................................................... 48
13 Package Detail ..........................................................................................................................................49
Revision History
Revision #
TC9204-DS-R04
TC9204-DS-R05
Change Description
1. Modify “Pin Latched” field in Class of Service section.
2. Correct the register map of “Broadcast Configuration Register”
3. Correct the junction temperature limit.
Confidential.
Copyright © 2003, IC Plus Corp.
4/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
Pins Placement
txd47/BcstThrot
txd46/OBMTest
txd45/FcBcstMode
txd43
txd44/FcBcstEn
Vss 2.0
txd41/priclass41
txd42/EnPORTPr
txd40/priclass40
txen4/RejRDA
gtxclk4
Vdd 3.3
txer4
txclk4
col4
crs4
rxer4
Vss 3.3
rxdv4
rxclk4
rxd40
rxd41
rxd42
rxd43
rxd44
rxd45
rxd46
rxd47
Vdd 3.3
FullBp
CarrBp
DisBkPr
NC
Vss 3.3
FrcFdFc
DisFdFc
Vdd 2.0
DisBPBk
Gnd
Vss 2.0
NC
Gnd
NC
NC
NC
Vdd 2.0
mdc
mdio
Vss 2.0
Scl
Sda
Testint
208207 206 205204 203 202 201 200199198 197196195 194 193192 191 190 189 188187186 185184183 182 181180 179 178 177 176175174 173172 171 170 169 168 167 166 165164 163162161160 159158 157
NC
1
156
NC
NC
2
155
NC
NC
3
154
NC
NC
4
153
NC
Vdd 3.3
5
152
NC
txd67
6
151
Gnd
txd66
7
150
Vdd 2.0
txd65
8
149
Gnd
Vss 3.3
9
148
Vss 3.3
txd64
10
147
VLANPrMap0
txd63
11
146
Vdd 3.3
txd62
12
145
VLANPrMAp1
Vdd 3.3
13
144
EnVLANPr
txd61/priclass61
14
143
IPTosMap0
txd60/priclass60
15
142
IPTosMap1
txen6
16
141
EnlPPr
gtxclk6
17
140
rxd27
Vss 3.3
18
139
rxd26
txer6
19
138
rxd25
txclk6
20
137
rxd24
crs6
21
136
rxd23
col6
22
135
Vss 3.3
rxer6
23
134
rxd22
Vdd 2.0
24
133
rxd21
rxclk6
25
132
rxd20
rxdv6
26
131
rxdv2
rxd60
27
130
rxclk2
rxd61
28
129
Vdd 3.3
rxd62
29
128
rxer2
Vss 2.0
TC9204M
30
127
col2
rxd63
31
126
crs2
rxd64
32
125
txclk2
rxd65
33
124
txer2
rxd66
34
123
Vss 2.0
rxd67
35
122
gtxclk2
Vdd 3.3
36
121
txen2
Vss 3.3
37
120
txd20/priclass20
Vdd 2.0
38
119
txd21/priclass21
Vss 2.0
39
118
txd22/PriBndw0
Vdd 3.3
40
117
Vdd 2.0
Gnd
41
116
txd23/PriBndw1
Vss 3.3
42
115
txd24
Gnd
43
114
txd25
Vdd 3.3
44
113
txd26
Vss 3.3
45
112
txd27
NC
46
111
reset
NC
47
110
SysCk
NC
48
109
Vss 2.0
NC
49
108
OvUnLED
NC
50
107
BcstLED
NC
51
106
Vdd 2.0
NC
52
105
Gtxck
53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100101102103104
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
SelSck
Vdd 3.3
Gnd
Vss 3.3
Gnd
Vdd 3.3
Vss 2.0
Vdd 2.0
Vss 3.3
Vdd 3.3
rxd07
rxd06
5/49
rxd05
rxd04
rxd03
Vss 2.0
rxd02
rxd01
rxd00
rxdv0
rxclk0
Vdd 2.0
rxer0
col0
crs0
txclk0
txer0
Vss 3.3
gtxclk0
txen0
txd00/priclass00
txd01/priclass01
Vdd 3.3
txd02
txd03
txd04
Vss 3.3
txd05
txd06
txd07
Vdd 3.3
Confidential.
Copyright © 2003, IC Plus Corp.
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
1
Pin Listing (PQFP208)
I
Is
Ipd
I/O
I/Opd
⇒ digital input
⇒ schmitt trigger digital input
⇒ digital input with internal pull down
⇒ digital bi-directional
⇒ digital bi-directional with internal pull down
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Pin label
NC
NC
NC
NC
Vdd 3.3
Txd67
Txd66
Txd65
Vss 3.3
Txd64
Txd63
Txd62
Vdd 3.3
Txd61
priclass61
Txd60
priclass60
Type
NA
NA
NA
NA
P
O
O
O
G
O
O
O
P
I/Opd
16
17
18
19
20
21
22
23
24
25
26
27
Txen6
Gtxclk6
Vss 3.3
Txer6
Txclk6
Crs6
Col6
Rxer6
Vdd 2.0
Rxclk6
Rxdv6
Rxd60
O
O
G
I/Opd
I
Is
Is
Is
P
I
Is
Is
28
Rxd61
Is
15
I/Opu
Confidential.
Copyright © 2003, IC Plus Corp.
I/Opu
O
P
G
⇒ digital bi-directional with internal pull up
⇒ digital output
⇒ power
⇒ ground
Description
Reserved for future use
Reserved for future use
Reserved for future use
Reserved for future use
Digital +3.3V power supply for I/O
GMII transmit data - bits 7
GMII transmit data - bits 6
GMII transmit data - bits 5
Digital ground for I/O
GMII transmit data - bits 4
GMII/MII transmit data - bits 3
GMII/MII transmit data - bits 2
Digital +3.3V power supply for I/O
GMII/MII transmit data - bit 1
Priority class - most significant bit.
GMII/MII transmit data - least significant bit
Priority class - least significant bit. Sets priority level per port basis.
PriClass[6] - '00' - port 6 low priority
PriClass[6] - '01' - port 6 has normal priority
PriClass[6] - '10' - port 6 has high priority
PriClass[6] - '11' - port 6 has very high priority
PriClass[6] is latched on reset
GMII/MII transmit enable
GMII transmit clock
Digital ground for I/O
Transmit Error
MII transmit clock
MII carrier sense indication
MII collision indication
Receive Error
Digital +2.0V power supply for core
MII receive clock
GMII/MII data valid
GMII receive data - least significant nibble.
MII receive data
GMII receive data - least significant nibble.
MII receive data
6/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
Pin Listing (continued)
No.
29
Pin label
Rxd62
30
31
Vss 2.0
Rxd63
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
Rxd64
Rxd65
Rxd66
Rxd67
Vdd 3.3
Vss 3.3
Vdd 2.0
Vss 2.0
Vdd 3.3
Gnd
Vss 3.3
Gnd
Vdd 3.3
Vss 3.3
NC
NC
NC
NC
NC
NC
NC
Vdd 3.3
Txd07
Txd06
Txd05
Vss 3.3
Txd04
Txd03
Txd02
Vdd 3.3
Txd01
Priclass01
Txd00
Priclass00
63
Type
Description
Is
GMII receive data - least significant nibble.
MII receive data
G
Digital ground for core
Is
GMII receive data - least significant nibble.
MII receive data
Is
GMII receive data - most significant nibble
Is
GMII receive data - most significant nibble
Is
GMII receive data – most significant nibble
Is
GMII receive data – most significant nibble
P
Digital +3.3V power supply for I/O
G
Digital ground for I/O
P
Digital +2.0V power supply for core
G
Digital ground for core
P
Digital +3.3V power supply for I/O
I
G
Digital ground for I/O
I
P
Digital +3.3V power supply for I/O
G
Digital ground for I/O
NA Reserved for future use
NA Reserved for future use
NA Reserved for future use
NA Reserved for future use
NA Reserved for future use
NA Reserved for future use
NA Reserved for future use
P
Digital +3.3V power supply for I/O
O
GMII transmit data – bits 7
O
GMII transmit data – bits 6
O
GMII transmit data – bits 5
G
Digital ground for I/O
O
GMII transmit data – bits 4
O
GMII/MII transmit data – bits 3
O
GMII/MII transmit data – bits 2
P
Digital +3.3V power supply for I/O
I/Opd GMII/MII transmit data – bit 1
Priority class – most significant bit.
I/Opu GMII/MII transmit data – least significant bit
Priority class – least significant bit. Sets priority level per port basis.
PriClass[0] – ‘00’ – port 0 has low priority
PriClass[0] – ‘01’ – port 0 has normal priority
PriClass[0] – ‘10’ – port 0 has high priority
PriClass[0] – ‘11’ – port 0 has very high priority
PriClass[0] is latched on reset
Confidential.
Copyright © 2003, IC Plus Corp.
7/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
Pin Listing (continued)
No.
64
65
66
67
68
69
70
71
72
73
74
75
Pin label
Txen0
Gtxclk0
Vss 3.3
Txer0
Txclk0
Crs0
Col0
Rxer0
Vdd 2.0
Rxclk0
Rxdv0
Rxd00
Type
O
O
G
I/Opd
I
Is
Is
Is
P
I
Is
Is
76
Rxd01
Is
77
Rxd02
Is
78
79
Vss 2.0
Rxd03
G
Is
80
81
82
83
84
85
86
87
88
89
90
91
92
93
Rxd04
Rxd05
Rxd06
Rxd07
Vdd 3.3
Vss 3.3
Vdd 2.0
Vss 2.0
Vdd 3.3
Gnd
Vss 3.3
Gnd
Vdd 3.3
SelSck
Is
Is
Is
Is
P
G
P
G
P
I
G
I
P
Is
94
95
96
97
98
99
100
NC
NC
NC
NC
NC
NC
NC
NA
NA
NA
NA
NA
NA
NA
Confidential.
Copyright © 2003, IC Plus Corp.
Description
GMII/MII transmit enable
GMII transmit clock
Digital ground for I/O
Transmit Error
MII transmit clock
MII carrier sense indication
MII collision indication
Receive Error
Digital +2.0V power supply for core
MII receive clock
GMII/MII data valid
GMII receive data – least significant nibble.
MII receive data
GMII receive data – least significant nibble.
MII receive data
GMII receive data – least significant nibble.
MII receive data
Digital ground for core
GMII receive data – least significant nibble.
MII receive data
GMII receive data – most significant nibble
GMII receive data – most significant nibble
GMII receive data – most significant nibble
GMII receive data – most significant nibble
Digital +3.3V power supply for I/O
Digital ground for I/O
Digital +2.0V power supply for core
Digital ground for core
Digital +3.3V power supply for I/O
Digital ground for I/O
Digital +3.3V power supply for I/O
Selects the source for the system clock.
Selsck – ‘1’ – sysck is driven by a 25Mhz external clock.
Reserved for future use
Reserved for future use
Reserved for future use
Reserved for future use
Reserved for future use
Reserved for future use
Reserved for future use
8/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
Pin Listing (continued)
No.
101
102
103
104
105
Pin label
NC
NC
NC
NC
Gtxck
Type
NA
NA
NA
NA
I
106
107
Vdd 2.0
BcstLED
P
I/Opd
108
OvUnLED
O
109
110
111
112
113
114
115
116
Vss 2.0
Sysck
Reset
Txd27
Txd26
Txd25
Txd24
Txd23
PriBndw1
G
I
Ipus
I/Opd
I/Opd
I/Opd
O
I/Opd
117
118
Vdd 2.0
Txd22
PriBndw0
P
I/Opu
119
Txd21
I/Opd
120
priclass21
Txd20
priclass20
I/Opu
121
122
123
124
125
126
Txen2
Gtxclk2
Vss 2.0
Txer2
Txclk2
Crs2
O
O
G
I/Opd
I
Is
Confidential.
Copyright © 2003, IC Plus Corp.
Description
Reserved for future use
Reserved for future use
Reserved for future use
Reserved for future use
The 125Mhz reference clock for 1000Mbps operating mode. This clock is
used as a reference clock for the GMII transmission clock for every port.
Digital +2.0V power supply for core
The led can signal either filtering of broadcast frames. Also the led
remains lit if the POST test fails, which indicates a faulty chip.
The led is lit whenever a unicast packets overflow condition is reached
and some frames are dropped by the buffer management engine.
Digital ground for core
The 25Mhz system clock.
General reset. Active Low.
GMII transmit data - most significant bit
GMII transmit data - bit 6
GMII transmit data - bit 5
GMII transmit data - bit 4
GMII/MII transmit data - bit 3
Priority bandwidth configuration pins.
PriBndw(1)is latched on reset
Digital +2.0V power supply for core
GMII/MII transmit data - bit 2
Priority bandwidth configuration pins. These configuration pins allow the
bandwidth percentage assigned to a priority packet queue to be modified
to certain hardwired levels. PriBndw chooses between 4 hardwired
spreading percentage schemes among the 4 priority queues of each port.
PriBndw(0)is latched on reset
GMII/MII transmit data - bit 1
PriClass[2] is latched on reset
Priority class - most significant bit.
GMII/MII transmit data - least significant bit
Priority class - least significant bit. Sets priority level per port basis.
PriClass[2] - '00' - port 2 low priority
PriClass[2] - '01' - port 2 has normal priority
PriClass[2] - '10' - port 2 has high priority
PriClass[2] - '11' - port 2 has very high priority
PriClass[2] is latched on reset
GMII/MII transmit enable
GMII transmit clock
Digital ground for core
Transmit Error
MII transmit clock
MII carrier sense indication
9/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
Pin Listing (continued)
No.
127
128
129
130
131
132
Pin label
Col2
Rxer2
Vdd 3.3
Rxclk2
Rxdv2
Rxd20
Type
Is
Is
P
I
Is
Is
133
Rxd21
Is
134
Rxd22
Is
135
136
Vss 3.3
Rxd23
G
Is
137
138
139
140
141
Rxd24
Rxd25
Rxd26
Rxd27
EnlPPr
Is
Is
Is
Is
I/Opd
142
IPTosMap1
I/Opd
143
IPTosMap0
I/Opu
144
EnVLANPr
I/Opu
145
VLANPrMap1
I/Opu
146
Vdd 3.3
Confidential.
Copyright © 2003, IC Plus Corp.
P
Description
MII collision indication
Receive Error
Digital +3.3V power supply for I/O
MII receive clock
GMII/MII data valid
GMII receive data - least significant nibble.
MII receive data
GMII receive data - least significant nibble.
MII receive data
GMII receive data - least significant nibble.
MII receive data
Digital ground for I/O
GMII receive data - least significant nibble.
MII receive data
GMII receive data - most significant nibble
GMII receive data - most significant nibble
GMII receive data - most significant nibble
GMII receive data - most significant nibble
Enables IP prioritization. CoS resolution will consider TOS
Precedence bits from IP Header.
‘1’ – IP priority will be taken into consideration
‘0’ – IP priority will be neglected
EnIPPr is latched on reset
IP type of service mapping - the most significant bit
IPTosMap(1) is latched on reset
IP type of service mapping - the least significant bit. This configuration
chooses between 4 hard-wired mapping schemes for the associations
of IP priority within the received packet and one of the 4 priority levels
set by PriClass. The resolution function is used for the final priority
class if the receiving port already has a priority level assigned by
PriClass configuration, or the VLAN prioritization is active.
IPTosMap(0) is latched on reset.
Enables VLAN prioritization. CoS resolution will consider user priority
bits (TCI field) from 802.1Q VLAN Tag Header.
‘1’ – VLAN priority will be taken into consideration
‘0’ – VLAN priority will be neglected
EnVLANPr is latched on reset
VLAN priority mapping
VLANPrMap(1)is latched on reset.
Digital +3.3V power supply for I/O
10/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
Pin Listing (continued)
No.
147
Pin label
VLANPrMap0
148
149
150
151
152
153
154
155
156
157
Vss 3.3
Gnd
Vdd 2.0
Gnd
NC
NC
NC
NC
NC
Txd47
BcstThrot
158
159
Txd46
Txd45
FcBcstMode
160
Txd44
FcBcstEn
161
162
163
164
Txd43
Vss 2.0
Txd42
Txd41
Priclass41
Type
Description
I/Opu VLAN priority mapping
This configuration chooses between 4 hard-wired mapping schemes
for the associations of VLAN priority within the received packet and
one of the 4 priority levels set by PriClass. The resolution function is
used for the final priority class if the receiving port already has a
priority level assigned by PriClass configuration, or the VLAN
prioritization is active.
VLANPrMap(0)is latched on reset.
G
Digital ground for I/O
I
P
Digital +2.0V power supply for core
I
NA Reserved for future use
NA Reserved for future use
NA Reserved for future use
NA Reserved for future use
NA Reserved for future use
I/Opd GMII transmit data - bit 7
Enables broadcast throttling.
'1' – Enable
'0' – Disable
BcstThrot is latched on reset.
I/Opd GMII transmit data - bit 6
I/Opd GMII transmit data - bit 5
This pin changes the flow control threshold’s behaviour if pin 160 is
set to logic 1 (It enables broadcast function).
'1' – only the flow control threshold on the broadcast queue is considered
'0' – flow control thresholds associated to each source port originating the
broadcast frames are considered FCBcstMode is latched on reset.
I/Opd GMII transmit data - bit 4
Enables/disables flow control for broadcast packets.
'1' – enabled
'0' – disabled
FcBcstEn is latched on reset.
I/Opd GMII/MII transmit data - bit 3
G
Digital ground for core
I/Opd GMII/MII transmit data - bit 2
I/Opd GMII/MII transmit data - bit 1
Priority class - most significant bit.
PriClass[4] is latched on reset.
Confidential.
Copyright © 2003, IC Plus Corp.
11/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
Pin Listing (continued)
No.
165
Pin label
Txd40
Priclass40
166
Txen4
RejRDA
167
168
169
170
171
172
173
174
175
176
177
gtxclk4
Vdd 3.3
Txer4
Txclk4
Crs4
Col4
Rxer4
Vss 3.3
Rxclk4
Rxdv4
Rxd40
178
Rxd41
179
Rxd42
180
Rxd43
181
182
183
184
185
186
Rxd44
Rxd45
Rxd46
Rxd47
Vdd 3.3
FullBp
Type
Description
I/Opd GMII/MII transmit data - least significant bit
Priority class - least significant bit. Sets priority level per port basis.
PriClass[4] - '00' - port 4 low priority
PriClass[4] - '01' - port 4 has normal priority
PriClass[4] - '10' - port 4 has high priority
PriClass[4] - '11' - port 4 has very high priority
PriClass[4] is latched on reset
I/Opd GMII/MII transmit enable
If this pin is set to '1' then all frames with 802.1D Reserved Group
Address or 802.3x Full Duplex PAUSE operation DA will be filtered
out. This setting is provided for testing purposes only and it is
recommended to set high during normal operation.
RejRDA is latched on reset.
O
GMII transmit clock
P
Digital +3.3V power supply for I/O
I/Opd Transmit Error
I
MII transmit clock
Is
MII carrier sense indication
Is
MII collision indication
Is
Receive Error
G
Digital ground for I/O
I
MII receive clock
Is
GMII/MII data valid
Is
GMII receive data - least significant nibble.
MII receive data
Is
GMII receive data - least significant nibble.
MII receive data
Is
GMII receive data - least significant nibble.
MII receive data
Is
GMII receive data - least significant nibble.
MII receive data
Is
GMII receive data - most significant nibble
Is
GMII receive data - most significant nibble
Is
GMII receive data - most significant nibble
Is
GMII receive data - most significant nibble
P
Digital +3.3V power supply for I/O
I/Opd During the normal operation, the backpressure process is executed
until flow control condition disappears or until the time limit for
backpressure is reached. The backpressure time limit is based in the
EEPROM’s BPTimeValue register.
When this configuration is ‘0’ the backpressure process will also be
limited from exceeding 28-consecutive collisions. The default value
(28) can be changed in the EEPROM settings.
FullBp is latched upon reset
Confidential.
Copyright © 2003, IC Plus Corp.
12/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
Pin Listing (continued)
No.
187
Pin label
CarrBp
188
DisBkPr
189
190
NC
FrcFdFc
191
192
Vss 3.3
DisFdFc
193
DisBPBk
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
Vdd 2.0
Gnd
Vss 2.0
Gnd
NC
NC
NC
NC
Vdd 2.0
mdc
mdio
Vss 2.0
Scl
Sda
Testint
Type
Description
I/Opd Enable / disable carrier based backpressure for half -duplex mode.
'1' – Carrier based backpressure
‘0' – Collision based backpressure.
CarrBp is latched on reset
I/Opd Setting this pin to ‘1’ will disable backpressure procedure for all half
duplex ports. DisBkPr is latched upon reset.
I/Opd Setting this bit to ‘1’ will force flow control execution for 10/100Mbps,
no matter the auto negotiation result. FrcFdFc is latched upon reset.
G
Digital ground for I/O
I/Opd Setting this bit to '1' will disable flow-control for full-duplex mode
(transmission of pause frames).
DisFdFc is latched upon reset.
I/Opd Enable / disable backoff during backpressure.
'1' – No backoff executed. Another collision will be forced again after one
minimum IFG time following previous collision if carrier sense is
observed.
'0' – The MAC randomly chooses between 0 and 1 slot times of backoff.
DisBkBp is latched during the reset operation.
P
Digital +2.0V power supply for core
I
G
Digital ground for core
I
NA Reserved for future use
NA Reserved for future use
NA Reserved for future use
NA Reserved for future use
P
Digital +2.0V power supply for core
O
MDIO Clock.
I/Opu MDIO Data.
G
Digital ground for core
I/Opu EEPROM's serial clock.
I/Opu EEPROM's serial data.
I/Opd TestInt - '0' - switch normal mode(default)
TestInt -'1' - internal memory test mode.
Confidential.
Copyright © 2003, IC Plus Corp.
13/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
2
Ethernet Media Access Controller
The TC9204M’s Ethernet Media Access Controller (MAC) contains IEEE 802.3 MAC functions for 4 Ports.
It is able to operate in 10/100/1000 full duplex and 10/100 half duplex modes for all ports. Each port has
its dedicated receive and transmit FIFO with necessary logic to implement flow control for both duplex
modes. The MAC functions are specially designed for high speed and flexible interfacing.
2.1
Receive MAC
When a frame is received from the Ethernet media through the MII interface, it is then stored in a
dedicated receive FIFO. This FIFO acts as a temporary buffer between the Receive MAC section and
switch core interface.
The Receive MAC layer extracts the valid ethernet information by stripping off the preamble sequence
and SFD of the received frame, which the frame was acquired from the PHY layer via either GMII or MII
interface. The Receive MAC then sends packets with valid information to the receive FIFO.
TC9204M determines the validity of each received packet by checking the CRC and packet length. The
bad packets will be dropped either by the MAC or by the queue manager. Oversized packets are
truncated to 1536 bytes and marked as erroneous packets. Undersized packets are removed from the
receive FIFO without being reported to the switch interface. Therefore the FIFO space held by
undersized packets will be removed automatically.
In Full Duplex mode the Receive MAC can identify any received frame as a flow control frame having a
valid CRC. It will load its internal pause counter with the ‘pause quanta’ value extracted from the
incoming frame. The flow control frame will be rejected after the pausing period has been acquired. After
the pausing period has obtained from the flow control frame, the flow control mechanism inside
TC9204M will set a decremental timer in the pause counter according to the value of the pausing period.
A non-zero value sets in the pause counter will issue the Receive MAC to XOFF (Transmit Stop) the
Transmit MAC. The pause counter will decrement the ‘pause quanta’ value after each slot time until it
reaches zero. If the pause quanta value is equal to zero the flow control mechanism will XON (Transmit
Enable) the Transmit MAC.
If a frame transmission is in progress when the PAUSE frame is received, the transmission is allowed to
complete for the current transmitting frame but the transmission for the next frame(s) will hold until the
Receive MAC generates an XON command. The pause time will begin at the end of current transmission
or start immediately if no transmission is in the medium when the PAUSE frame is received. If a pause
command is received while the transmitter is already in pause, the new pause time indicated by the new
Flow Control frame will be loaded into the pause register.
The MAC is also able to reject frames containing IEEE 802.1D Reserved Group Destination Addresses
and frames with Mac Control Type (Type 88-08) if selected through configuration settings.
When the receive FIFO is full and additional data are still incoming from the MAC, then the overrun
condition occurs and the frame is dropped. If the system clock frequency is not lower than the
recommended value this condition will never occur.
Confidential.
Copyright © 2003, IC Plus Corp.
14/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
2.2
Transmit MAC
The Transmit MAC section assembles the MAC frames stored in the transmit FIFO and controls their
transmission onto the media via external PHY entities. It appends the standard preamble and start of
frame delimiter to the transmitted packets. The MAC also controls the interframe gap time during
transmission, maintaining for default the standard minimum interframe gap of 96-bit time. This value can
be changed in the EEPROM register setting.
For Half Duplex mode the Transmit MAC meets CSMA/CD IEEE 802.3 requirements. The FIFO logic
manages frame retransmission for early collision conditions or discards the frame if late collision occurs.
It also follows the truncated binary exponential backoff algorithm, collision and jamming procedures.
The transmit FIFO stores the packets which are ready for transmission in the main memory queues. If
there is no packet ready in the transmit FIFO before the current packet completes its transmission, an
underrun condition has occurred and the mechanism will generate a signal to indicate FIFO underrun
event, but if the switch core transfers the rest of the packet(s) into the FIFO, the Transmit MAC will safely
discard it without affecting the next packet. Underrun conditions never occur if the system is operating at
the recommended clock frequency or higher.
For full duplex mode TC9204M implements the flow control algorithm according to the IEEE 802.3x standard,
using the XON/XOFF method. Full duplex flow control can be configured automatically, by auto-negotiation
result, or manually, pin configuration and/or EEPROM settings, to enable/disable the function.
The TC9204M executes backpressure algorithm for half duplex flow control supporting both collision
based and carrier based backpressure. Both modes are based on carrier sense forced collisions and an
aggressive backoff algorithm. The forced consecutive collisions generated for flow control purposes can
be limited to a maximum of 28 collisions if this option is selected. This feature helps to avoid HUB
partitioning in heavy traffic. The number of collisions can be adjusted in EEPROM settings.
MAC Block Diagram
Rx Data (64) Tim e Value (16)
FC Insert Tx Data (64)
System Interface
Rx FIFO
Flow
Control
Rx MAC
Tx FIFO
Fifo Control Logic
Tx MAC
MAC
RMII Rx Data (2)
RMII Tx Data (2)
RMII
PHY Layer
Confidential.
Copyright © 2003, IC Plus Corp.
15/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
3
MAC Address Handling
After the frames are recovered from MAC FIFOs they are transferred to the queue management entity.
Prior to this transfer the DA and SA are extracted from each frame and passed to MAC Address Lookup
Table and Resolution Engine (ALR). The Lookup engine uses a proprietary hashing algorithm to access
its 8K address table.
The engine will update its table with each SA, if it is found to be unknown or migrated. Then it will update
the source port and aging information along with the new address. This learning process will be executed
for all addresses except for multicast SA frames (bit 40 is ‘1’). For stored addresses, aging function is
executed according to the time intervals set in the EEPROM registers. Default aging time is 600 seconds.
TC9024M also provide option to disable the aging mechanism, please refer to the EEPROM Register in
section 15.3.14 for more details.
Destination address is also analyzed in order to make forwarding decisions. If the destination address is
a broadcast or multicast address, the frame will flood to all ports except its originated port (source port). If
only some ports are allow to send those frame(s) with broadcast or multicast address(es), the destination
ports will search the for the port(s) with correct address(s) in the MAC address table. If the address is
found to be unknown, the frame will be also flooded to every port, otherwise frame(s) will be forwarded to
the legitimate port(s) only.
TC9204M will filter following frames:
Erroneous frames. This includes :
- frames with CRC error;
- undersized frames;
- oversized frames;
- frames that presents alignment error (this doesn’t include frames with dribble bits).
802.3x pause frames. These frames will be filtered after executing appropriate flow control actions;
Frames with 802.3x full duplex flow control PAUSE operation destination address. These frames
are not recognized as pause frames if the MAC type and subtype does not match the “88080001”H
value;
Frames with 802.1D Reserved Group Address destination address;
Frames with MAC Control Type (8808);
Local frames. If the port found to correspond to destination address matches the source port, then
the frame is considered to be local and discarded.
4
Queue Management
TC9204M operates in a store and forward mode implementing efficient switching method that minimizes
the overall latency. The queue manager uses the first in first out forwarding mode, which guarantees to
maintain frame order. Congestion control is implemented within TC9204M, which will eliminate
head-of-line blocking conditions.
The switch embeds a 2 Mbit SSRAM as a central frame buffer pool, which is divided into 208 byte buffers
to increase memory utilization efficiency. Normal and priority transmission queues are implemented
within TC9204M for each port. All available frame buffers are shared between all transmission queues
and each queue can fully extend to all buffers. Still memory resource utilization is limited on receive port
basis.
Evolved flow control and frame filtering mechanisms are implemented based on source, transmit and
global memory load to maximize performance and minimize packet loss.
Confidential.
Copyright © 2003, IC Plus Corp.
16/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
5
Classes of Service
TC9204M implements advanced Class of Service (CoS), supporting both traffic priority and delay bound
features. It provides four classes of service: class 0 (low), class 1 (normal), class 2 (high) and class 3
(very high). Each class of service has its dedicated transmission queue for each port. The frames assign
with higher service class will arrive sooner at the destination.
Frames in the class 0 priority queue get the lowest transmission bandwidth percentage, while frames in
the class 3 priority queues get the highest bandwidth percentage. The bandwidth percentage depends
on two elements:
CoS bandwidth weights, and
The corresponding class of all non-empty queues for the respective port.
The CoS weights can be set by using PriBndw [1:0] shared configuration pins or by setting the
EEPROM Registers. While the pins provide only four predefined hardwired combinations for the
transmission bandwidth percentage allocation among the queues, the EEPROM gives more flexibility
over this configuration.
When EEPROM is not present, transmission bandwidth percentage distribution among the queues for
the case when all the queues are loaded can be seen in the table below:
PriBndw[1:0]
00
01
10
11
EEPROM is not present
Transmission Bandwidth Percentage
Class 0 Priority
Class 1 Priority
Class 2 Priority
(lowest)
7%
13%
27%
3%
14%
27%
2%
8%
30%
3%
5%
10%
Class 3 Priority
(highest)
53%
56%
60%
82%
The percentage refers to the port’s bandwidth, which is determined by the current operating speed.
Those values are the guaranteed minimum ones and the transmission bandwidth percentage cannot
drop below specified value under any circumstance. If EEPROM is used, the user has more flexible
adjustment of bandwidth weights to choose from the EEPROM register.
A special early packet dropping mechanism is also implemented to offer more protection against
overflow conditions for priority packets. If the global memory load exceeds an overflow threshold, then all
class 0 priority packets will be dropped from the source port(s) in order to save space for the higher
priority packets. This will minimize the probability of packet loss in priority flows for senders that are not
flow control capable.
The CoS mechanism supports multiple prioritization sources: 802.1Q VLAN Tag Header (layer 2), IP
Header TOS bits (layer 3) and/or port based CoS. For IP and VLAN sources a mapping is executed
between the values of the fields extracted from each frame and one of the four CoS provided by
TC9204M. This mapping can be adjusted by using IPTosMap [1:0] and VLANPrMap [1:0] shared
configuration pins or the EEPROM settings. While the pins provide just four predefined hard-wired
mapping schemes, the EEPROM gives a custom explicit mapping.
Under some circumstances, one or more mechanisms can be actived at same time (VLAN, IP and/or
port based). In this case there is a resolution function that resolves the CoS for each incoming frame.
When EEPROM is not present and IP and/or VLAN prioritizations are enabled, the corresponding
headers of each incoming frames are parsed. The frame will be assigned the CoS corresponding to the
first header parsed that found valid. When both above prioritizations are enabled the search order is
Confidential.
Copyright © 2003, IC Plus Corp.
17/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
determined by EEPROM configuration (default is IP). If no header is found or corresponding
prioritizations are disabled then port based prioritization is executed. When EEPROM is present an
additional method of prioritization is available. This method consists of selecting the highest service class
from all classes corresponding to the enabled prioritization sources (IP, VLAN and port based). For both
methods, when no prioritization source is available the default CoS is used (default is normal priority –
CoS1 but it can be also changed by EEPROM configuration).
The CoS features can be configured by adjusting shared configuration pins and/or programming
EEPROM Register settings. VLAN prioritization can be enabled by EnVLPr shared configuration pin or
by EEPROM register settings, while EnIPPr shared configuration pin or the EEPROM Register settings
can enable IP prioritization. The shared configuration pins are sampled during reset.
The per-port basis CoS can be set using PriClass [x][1:0] shared configuration pins or configuring
EEPROM registers, where x stands for port number. The port-based prioritization can be disabled from
EEPROM settings only.
Configuration
PriClass[x][1:0]
Pins Latched
Description
TxDataX_[1:0] Set the priority class per port basis
'00' – the port has class 0 priority(lowest priority)
'01' – the port has class 1 priority
'10' – the port has class 2 priority
'11' – the port has class 3 priority(highest priority)
Enable/disable IP prioritization
EnIPPr
‘0’ – IP priority within the received packet (if exists) is ignored
‘1’ – IP priority within the received packet (if exists) is considered
Enable/disable VLAN prioritization
EnVLPr
‘0’ – VLAN priority within the received packet (if exists) is ignored
‘1’ – VLAN priority within the received packet (if exists) is considered
Selects one of four mappings for the 8 level precedence extracted
IPTosMap[1:0]
from frame’s IP header to the 4 CoS offered by TC9204M
(C0, C1, C2, C3 – class 0, 1, 2, 3 of service)
Designated priority class
IPTosMap[1:0]
0
1
2
3
4
5
6
7
C0 C0 C1 C1 C2 C2 C3 C3
00
C1 C2 C2 C2 C3 C3 C3 C3
01
C1 C1 C2 C2 C2 C3 C3 C3
10
C0 C1 C1 C2 C2 C3 C3 C3
11
Selects one of four mappings for the 8 level user_priority extracted
VLANPrMap[1:0]
from the frame’s VLAN Tag to the 4 level priority offered by TC9204M
(C0, C1, C2, C3 – class 0, 1, 2, 3 of service)
Designated priority class
VLANPrMap[1:0] 0
1
2
3
4
5
6
7
C0 C0 C1 C1 C2 C2 C3 C3
00
C1 C0 C0 C1 C2 C2 C3 C3
01
C0 C0 C0 C1 C1 C2 C3 C3
10
C2 C0 C1 C2 C3 C3 C3 C3
11
Confidential.
Copyright © 2003, IC Plus Corp.
18/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
6
Flow Control
Whenever the memory load exceeds preset thresholds, flow control commands are issued by the traffic
management entity to the transmit MACs to prevent overflow conditions occurred. The overrun
conditions are either locally or globally triggered, depending on the traffic management entity
configuration. Transmit MAC executed those flow control commands depending on the duplex mode
status. TC9204M executes backpressure for half duplex operation mode and it is IEEE 802.3x compliant
for full duplex operation mode. In special conditions forward-pressure is also executed to eliminate
packet loss.
For full duplex operation mode, TC9204M applies the XON/XOFF method using IEEE 802.3x PAUSE
frames. When a flow control command is internally generated, the transmit MAC inserts a pause frame
immediately or after the current transmission ends. On the receiving side, if a flow control frame is
received, the transmit MAC will stop transmission for a number of slot times, where the pausing time was
extracted from the received pause frame. The flow control function of the receiving side is always
operational unless is specifically disabled by EEPROM on a per port basis (if no EEPROM is present the
receive side flow-control is always operational), while transmission of the pause frames obeys the auto
negotiation result.
TC9204M recognizes flow control frames from the incoming frames and these frames should also have a
valid CRC. The IEEE 802.3x PAUSE operation reserves destination address, MAC control type and
PAUSE opcode (88-08-00-01). The chip filters all frames having PAUSE operation reserved DA
disregarding the other fields. If enabled, direct flow control addressing can be executed. This implies
inserting the port address as SA in each flow control frame generated by TC9204M and recognizing as
flow control all received frames with the port’s address as DA, MAC control type and PAUSE opcode.
After recognizing and executing appropriate flow control actions these frames will be also filtered. The
port address is obtained by adding the port’s number to the base address contained within EEPROM.
When no EEPROM is present and DisFdFC shared configuration pin is configured to high state, the
switch will inhibit its ability to send flow control packets on all ports while preserving its ability to receive
and act upon the incoming flow control packets. If this pin is configured to low state the switch will
execute symmetrical PAUSE operation as defined in 802.3x.
The function of enabling/disabling the flow control in the EEPROM is now available on a per port basis
rather than setting flow control globally for all ports and separate enabling/disabling flow control ability
can be performed on either receive or transmit side of a port.
TC9204M can be instructed to ignore the auto-negotiation result for full duplex flow control ability. When the
FrcFdFC shared configuration pin or the equvalent register in the EEPROM is equal to 1, the link partner
will be considered to have full duplex flow control capable no matter of auto-negotiation result. The
FrcFdFC setting is effective only for ports configured in 10/100 Mbps speed modes. When the FrcGbFC
and the equivalent register in the EEPROM is equal to 1, the link partner will be considered symmetrically
and asymmetrically towards link partner full duplex flow control capable no matter of auto-negotiation result.
The FrcGbFC setting is effective only for ports configured in 1000 Mbps speed mode.
The TC9204M executes backpressure algorithm for half duplex flow control, supporting both
collision-based and carrier-based backpressure. For collision-based backpressure the switch will be
forced to send collision signals to the terminal that sends packets to TC9204M. While TC9204M detects
an incoming frame that it wishes to backpressure with carrier sense signals, the switch will start
transmission to that port. If no packet is available at that moment for transmission then the MAC layer will
generate short jamming frames. Additionally, an aggressive backoff will be executed by the transmit
MAC after each of the forced collisions. The transmit MAC will chose between 0 and 1 slot times to
backoff. This will grant a fast recovery for the switch's congested port and will secure the channel for the
congested port in case it wishes to transmit (empty its buffers). If desired, the backoff can be completely
Confidential.
Copyright © 2003, IC Plus Corp.
19/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
disabled using shared configuration pin DisBPBk or EEPROM. In this case the switch will start
transmitting with minimum IFG after carrier sense is deasserted and followed after collision.
For carrier-based backpressure the switch will use the deferral mechanism rather than the collision
backoff mechanism. The transmit MAC will jam the line by sending continuous preamble. The link
partner will see the channel busy and thus it will defer transmission without imposing any additional
backoff delay. The jamming procedure will have short break to avoid jabber condition and the break will
also be short enough to prevent the other stations from starting transmission. Preamble can be sent this
way as long as necessary. If valid packets became available for transmission during this period then
jamming will be interrupted and the packets will be transmitted with standard IFG (Inter-Frame Gap). In
this case backpressure is executed the same way as collision based mechanism. Carrier based
backpressure can be selected using shared configuration pin CrBP or EEPROM.
Backpressure operation can be disabled globally using the shared configuration pin DisBkPr or per port
basis using the EEPROM. By default forward pressure is also enabled whenever backpressure is
enabled. Forward pressure is executed only in extreme congestion conditions that normally do not occur
often. This flow control procedure is highly efficient in minimizing the packet loss. If desired, the forward
pressure can be disabled by the EEPROM setting.
If a HUB is connected to many workstations, one of the ports may be partitioned in heavy traffic when the
switch executes backpressure. TC9204M can prevent this by discontinuing the backpressure process after
a predefined number of consecutive collisions have reached. This function can be enabled using the
shared configuration pin FullBP or adjusting EEPROM setting. Unlike other settings, to enable this feature
the pin/bit should be set to '0'. The respective number of collisions defaults to 28 and can be specified using
the EEPROM. In addition, when this feature is enabled the MAC will either grant receiving the next packet
without colliding it, after which, it will resume the backpressure, or will completely quit backpressure waiting
for a new XOFF command from internal flow control management device.
Confidential.
Copyright © 2003, IC Plus Corp.
20/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
7
Broadcast Throttling
In case of excessive broadcast, TC9204M will throttle the broadcast traffic based on buffer memory
loading. Both global buffer pool loading and source port loading are considered. The number of frame
buffers that can be consumed by broadcast packets received from an individual source port is
permanently limited to the EEPROM configurable value (contained by SrcLoadTrsh field from Broadcast
Configuration Register). The default value is 32 when the EEPROM is not present. Additionally,
regarding the global aspect, broadcast frames are always dropped by broadcast queues overflow. Two
broadcast queues are implemented within TC9204M, one for low and normal priority (Classes 0 and 1)
and another for higher priorities (Classes 2 and 3).
Both filtering mechanisms described above can be avoided by enabling the flow control for broadcast
process. This mechanism can be enabled using the FcBcstEn pin shared configuration or by adjusting
the EEPROM setting. In this case the loading thresholds will never be reached and as result no
broadcast packet will be dropped although the filtering mechanism always remains active. If the
broadcast flow control is disabled TC9204M is still capable of taking continuous broadcast frames from
one port and deliver them to all the other ports at maximum speed without losing packets.
Independent of the throttling mechanisms, a bandwidth based broadcast throttling can be enabled using
the BcstThrot pin or by EEPROM setting. When this process is active, the receive broadcast bandwidth
per port will be limited to a value between 1% and 31% from the port’s maximum bandwidth. This
percentage is encoded within ThrotTrsh field from EEPROM's Broadcast Configuration Register. Default
value is 5 (%). Whenever the broadcast traffic bandwidth exceeds the above limit some broadcast
frames will be randomly dropped in order to precisely meet the enforced bandwidth.
TC9204M has the ability to give an indication about its status, from the broadcast packets handling issue
perspective. Its BcstLED pin can signal either if the incoming broadcast packets are dropped or if
broadcast packets overflow a certain threshold. During reset, this pin has the meaning of BcstCfg
shared configuration pin. If this pin is sampled low at reset, the BcstLED will behave as a broadcast
packets dropping indicator, it lights periodically whenever a broadcast packet is dropped due to buffer
overflow. If this pin is sampled high at reset, the led will light periodically whenever the percentage of the
received broadcast packets bandwidth in the last second to the whole port bandwidth exceeds a certain
threshold specified in the EEPROM. The default value for this threshold is 40% from the whole
bandwidth per port.
8
Port Mirroring
Although TC9204M is a smart switch, it has the ability to set a pair of mirroring ports. This feature is
available only through EEPROM settings. The port mirroring feature can be enabled by setting a value of
‘1’ in either EnTxMirror field from EEPROM’s PortMirrorConfig register or EnRxMirror field from the
same register, or both.
When port-mirroring feature has been enabled, the SourcePort field from EEPROM’s PortMirrorConfig
register selects the monitored port while DestinationPort field from EEPROM’s PortMirrorConfig
register selects the monitoring port. The traffic on the monitored (mirror source) port will be forwarded to
the monitor port (mirror destination). Both ports can be any of the TC9204M’s ports.
If EnRxMirror field is set to ‘1’ then all the incoming traffic of the mirror source port will be simultaneously
forwarded towards its due destination and to the monitoring port. The bad CRC / undersized frames will
be filtered out.
If EnTxMirror field is set to ‘1’ then all the outgoing traffic of the mirror source port will be also forwarded
to the monitoring port.
Confidential.
Copyright © 2003, IC Plus Corp.
21/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
9
Physical Layer Configuration / Polling
TC9204M embeds a Physical Layer MII Management configuration / polling entity which provides speed,
duplex, link status and link partner full duplex flow control ability information to the switch. This
information is obtained by continuously polling the status of Physical Layer devices through the serial
management interface. The entity is under control of EEPROM settings and it can operate in four
different modes. The polling entity also performs Phy configuration procedure at two seconds after reset
and each time EEPROM control information changes.
The following operating modes are available per port basis (selectable by ANMode field from EEPROM's
ConfigRegP[x]):
00 – Normal Mode (assumed by default when EEPROM is not present): In this mode the
Auto-Negotiation Enable bit from MII Control Register (0.12) is checked first. If it is found enabled
then TC9204M will disable advertisement for 1000BASE-T half duplex technology (9.8) and will
advertise the full duplex flow control ability (4.10:11) according with internal flow control enable
settings. Auto-negotiation is restarted leaving unchanged the rest of technology advertisements.
Then Auto-Negotiation Advertisement register (4), Link Partner Base Page Ability register (5) and
GMII registers (9:10) are polled continuously at 2 seconds interval in order to execute highest
common denominator resolution. If auto-negotiation is disabled as reported by 0.12 then the
switch will configure itself using bits 0.13 and 0.8 of Control register, and will consider link partner
full duplex flow control capable. Gigabit speed will be disabled.
01 – Advertise one mode: Auto-Negotiation Enable is checked and if found to be disabled
TC9204M will attempt to enable it. If successful the switch will force the port’s speed and duplex
mode by advertising only the technology corresponding to the Speed and Duplex fields from
EEPROM's ConfigRegP[x], otherwise bits 0.8 and 0.13 will be read for configuration and gigabit
speed will be disabled. Full duplex flow control ability is also advertised along with selected
technology and then auto-negotiation is restarted. An auto-negotiation register polling is executed
as in Normal Mode.
10 – Advertise multiple modes: This mode is similar with previous one except that it advertises
the technology corresponding to the forced mode and all lower position technologies, down to
10BASE-T half duplex.
11 – Disable Auto-Negotiation:
When this mode is selected then auto-negotiation is disabled
by setting bit 0.12 to ‘0’ and the forced speed and duplex mode will be written to Configuration
Register, bits 0.13, 0.6 and 0.8. This mode is available only for 10/100 Mbps speed modes so bit
0.6 will always be written as ‘0’. Link partner will be considered full duplex flow control capable.
In addition to the force mode feature, the TC9204M internal speed and duplex can be chosen between
enforced ones (Speed and Duplex fields from EEPROM's ConfigRegP[x]) and polling results by means
of ForceIntMode configuration.
Independently of Phy configuration/polling operation mode the Link Status is also permanently monitored.
If a Physical device reports link failure via 1.2 status bit then TC9204M disables transmission on
associated port without holding any memory resources allocated for its transmission queues. The
reported Link Status can be forced to ‘1’ using ForceLink bit from the same ConfigRegP[x] register.
Confidential.
Copyright © 2003, IC Plus Corp.
22/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10 EEPROM Interface
TC9204M can be configured using a serial EEPROM device type AT24C02A (2048 bits organized as 208
pages of 1 byte each). With this device the manufacturer can deliver a pre-configured system to their
customers while the customers can reconfigure the system and retain their preferences. TC9204M also
provides a virtual internal EEPROM mode, which enables the programming entity to write the
configuration data directly into the chip, without using the external EEPROM. In this mode the
configuration data is lost after reset procedures.
The TC9204M is able to operate without this device and can make effective use of its features using only
the pin configuration interface. The EEPROM configuration provides additional features and it can
override all pin interface settings offering a jumperless configuration mode. For this reason equivalent
EEPROM settings can be found for every configuration pin.
A validation bit is provided for each one of the EEPROM Configuration Registers. A dedicated Validation
Register is reserved for this purpose and corresponding bits from this register must be set in order to
enable the desired EEPROM configurations.
The EEPROM configuration information is accessed by the TC9204M after each reset procedure.
10.1
Reprogramming the EEPROM for reconfiguration
If the ‘Reset’ pin is hold Low the TC9204M‘s EEPROM interface will go into high impedance state. This
feature enables easy reprogramming of the EEPROM during installation or reconfiguration.
The EEPROM can be reprogrammed using an external parallel port. A dedicated signal from this port
can be used to hold the RESET pin Low. Once the TC9204M interface pins have got to the high
impedance state the EEPROM can be programmed by the parallel port trough the SDA and SCL pins.
To enable the AT24C02A device to be accessed by the TC9204M its page address input pins must be
hardwired to ‘0’. For virtual EEPROM mode the programming can be done using the same AT24C02A
byte write protocol but page address bits must be “100” (A2 downto A0).
SDA
TC9204M
EEPROM
SCL
Reset
Parallel
Port
Confidential.
Copyright © 2003, IC Plus Corp.
23/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.2
EEPROM Address Map
Physical
Address
EEPROM
00h
01h
02h
03h
04h
05h
06h
07h
08h
09h
0ah
0bh
0ch
0dh
0eh
0fh
10h
11h
12h
13h
14h
15h - 18h
19h
1ah
1bh
1ch
1dh
1eh
1fh
20h
21h – 2dh
2eh
2fh
30h
31h
32h
33h
34h
35h
36h
37h
Bits
Register Name
Validation Bit
DESCRIPTION
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
ValidReg [ 7 downto 0 ]
ValidReg [ 15 downto 8 ]
ValidReg [ 23 downto 16 ]
ValidReg [ 24 downto 31 ]
ValidReg [ 32 downto 39 ]
ConfigRegP0 [ 7 downto 0 ]
ConfigRegP0 [ 15 downto 8 ]
ConfigRegP0
Validation Register
Validation Register
Validation Register
Validation Register
Validation Register
Port 0 Configuration Register
ConfigRegP2 [ 7 downto 0 ]
ConfigRegP2 [ 15 downto 8 ]
ConfigRegP2
Port 2 Configuration Register
ConfigRegP4 [ 7 downto 0 ]
ConfigRegP4 [ 15 downto 8 ]
ConfigRegP4
Port 4 Configuration Register
ConfigRegP6 [ 7 downto 0 ]
ConfigRegP6 [ 15 downto 8 ]
ConfigRegP6
Port 6 Configuration Register
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
IFGConfigP0 [7 downto 0]
Reserved
IFGConfigP0
Port 0 IFG Configuration
IFGConfigP2 [7 downto 0]
IFGConfigP2
Port 2 IFG Configuration
IFGConfigP4 [7 downto 0]
IFGConfigP4
Port 4 IFG Configuration
IFGConfigP6 [7 downto 0]
IFGConfigP6
Port 6 IFG Configuration
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
Reserved
FlowContrReg
FlowControlReg [7 downto 0]
Flow Control Register
FlowControlReg [15 downto 8]
BPTimeValue [7 downto 0]
BPTimeValue Backpressure Time Value
Register
BPTimeValue [15 downto 8]
FCBaseAddress [47 downto 40] FCBaseAddress Flow Control Source Base
Address Register
FCBaseAddress [39 downto 32]
FCBaseAddress [31 downto 24]
FCBaseAddress [23 downto 16]
FCBaseAddress [15 downto 8]
FCBaseAddress [7 downto 0]
Confidential.
Copyright © 2003, IC Plus Corp.
24/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
Physical
Address
EEPROM
38h – 3bh
3ch
3dh
3eh
3fh
40h
41h
42h
43h
44h
45h
46h
47h
48h
49h
4ah
4bh – 4eh
4fh
50h
51h
52h
53h
54h
55h
56h
57h
58h
59h
5ah
5bh
5ch
5dh
5eh
5fh – 6fh
70h
71h
72h
73h
74h
75h
76h
Bits
Register Name
Validation Bit
DESCRIPTION
Reserved
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
BroadcastConfig [ 7 downto 0 ]
BroadcastConfig [15 downto 8 ]
IPTosMapping [ 7 downto 0 ]
IPTosMapping [15 downto 8 ]
VLANPriMapping [7 downto 0 ]
VLANPriMapping [15 downto 8 ]
CoSBandwidth [7 downto 0 ]
CoSBandwidth [15 downto 8 ]
[7 downto 0 ]
[15 downto 8 ]
CosConfig [7 downto 0]
PortMirrorReg [7 downto 0 ]
PortMirrorReg [15 downto 8 ]
GeneralConfig [ 7 downto 0 ]
[7:0]
[7:0]
PortVLANEn
VLAN0Reg [ 7 downto 0]
[7:0]
VLAN1Reg [ 7 downto 0]
[7:0]
VLAN2Reg [ 7 downto 0]
[7:0]
VLAN3Reg [ 7 downto 0]
[7:0]
VLAN4Reg [ 7 downto 0]
[7:0]
VLAN5Reg [ 7 downto 0]
[7:0]
VLAN6Reg [ 7 downto 0]
[7:0]
VLAN7Reg [ 7 downto 0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
[7:0]
DataWriteReg [15 downto 8 ]
DataWriteReg [ 7 downto 0 ]
PhyAddress [ 7 downto 0 ]
RegAddress [ 7 downto 0 ]
IOControl [ 7 downto 0 ]
DataReadReg [ 7 downto 0 ]
DataReadReg [ 15 downto 8 ]
Confidential.
Copyright © 2003, IC Plus Corp.
BroadcastConfig Broadcast Configuration Register
IPTosMapping
IP Priority Mapping Register
VLANPriMapping VLAN Priority Mapping Register
CoSBandwidth CoS Bandwidth Register
Reserved Register
CoSConfig
PortMirrorReg
GeneralConfig
Reserved
PortVLANEn
PVIDEn
Reserved
PVIDEn
Reserved
PVIDEn
Reserved
PVIDEn
Reserved
PVIDEn
Reserved
PVIDEn
Reserved
PVIDEn
Reserved
PVIDEn
Reserved
-
25/49
CoS Configuration Register
Port Mirroring Configuration
Register
General Configuration Register
Port VLAN Enable Register
ID 0 virtual LAN Register
ID 1 virtual LAN Register
ID 2 virtual LAN Register
ID 3 virtual LAN Register
ID 4 virtual LAN Register
ID 5 virtual LAN Register
ID 6 virtual LAN Register
ID 7 virtual LAN Register
Data Write Register
Phy Address Register
Phy's Register Address Register
IO Control Register
Data Read Register
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.3
10.3.1
Register Description
Validation Register
- Address: 00h - 04h
39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
ValidationReg
ConfigRegP0
Reserved
ConfigRegP2
Reserved
ConfigRegP4
Reserved
ConfigRegP6
Reserved
not used
IFGConfigP0
Reserved
IFGConfigP2
Reserved
IFGConfigP4
Reserved
IFGConfigP6
Reserved
not used
FlowContrReg
BPTimeValue
Reserved
BroadcastConfig
IPTosMapping
VLANPriMapping
QoSBandwidth
Reserved
QoSConfig
PortMirrorReg
GeneralConfig
not used
PortVLANEn
not used
Confidential.
Copyright © 2003, IC Plus Corp.
26/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
Bit(s)
Field
Description
39 – 0
ValidationReg
EEPROM’s Configuration Registers Validation Register
ValidationReg
ConfigRegP0
Reserved
ConfigRegP2
Reserved
ConfigRegP4
Reserved
ConfigRegP6
Reserved
IFGConfigP0
Reserved
IFGConfigP2
Reserved
IFGConfigP4
Reserved
IFGConfigP6
Reserved
FlowContrReg
BPTimeValue
TrunkConfig
BroadcastConfig
IPTosMapping
VLANPriMapping
CoSBandwidth
Reserved
CoSConfig
PortMirrorReg
GeneralConfig
PortVLANEn
– each bit from this register corresponds to an EEPROM Configuration Register.
To enable the use of a certain configuration register, a value of ‘1’ shall be
written to its corresponding bit from the validation register.
– validation bit for Port 0 Configuration Register
– should be ‘0’
– validation bit for Port 2 Configuration Register
– should be ‘0’
– validation bit for Port 4 Configuration Register
– should be ‘0’
– validation bit for Port 6 Configuration Register
– should be ‘0’
– validation bit for Port 0 IFG Configuration Register
– should be ‘0’
– validation bit for Port 2 IFG Configuration Register
– should be ‘0’
– validation bit for Port 4 IFG Configuration Register
– should be ‘0’
– validation bit for Port 6 IFG Configuration Register
– should be ‘0’
– validation bit for Flow Control Register
– validation bit for Back Pressure Time Value Register
– Reserved Register
– validation bit for Broadcast Configuration Register
– validation bit for IP Priority Mapping Register
– validation bit for VLAN Priority Mapping Register
– validation bit for CoS Bandwidth Register
– Reserved Register
– validation bit for CoS Configuration Register
– validation bit for Port Mirroring Register
– validation bit for General Configuration Register
– validation bit for Port VLAN Enable Register
Confidential.
Copyright © 2003, IC Plus Corp.
27/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.3.2
Port [X] Configuration Register
- Addresses: 05h - 14h
- Note: x is in range 0 to 7
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
ConfigRegP[x]
ANMode
ForceIntMode
Speed
Duplex
ForceLink
not used
TxDisable
RxDisable
DisFdxFCTx
DisFdxFCRx
DisBackPres
PortPriorityEn
PortPriority
Bit(s)
Field
Description
1-0
2
4-3
5
6
7
8
9
10
11
12
13
15 - 14
ANMode
ForceIntMode
Speed
Duplex
ForceLnk
not used
TxDisable
RxDisable
DisFdxFCTx
DisFdxFCRx
DisBackPres
PortPriorityEn
PortPriority
Operating mode selection for the phy configuration/polling entity
Internal speed and duplex selection enforcement
Internal speed selection (10 Mbps/100Mbps/1000Mbps)
Internal duplex selection (full/half)
Force Link Status to ‘ON’
not used
Disable transmit MAC
Disable receive MAC
Disable flow control in full duplex on transmit side
Disable flow control in full duplex on receive side
Disable backpressure
Enable port priority
Sets the priority class(class 0, class 1, class 2, class 3)
ANMode
This field selects the way auto-negotiation advertisements are configured by the
TC9204M’s physical layer management polling entity and the way Phy speed and
duplex modes are extracted from management registers. It can enable EEPROM
forced modes that also use Duplex and Speed bits below to configure the Phy mode.
00 – Normal Mode
01 – Advertise one mode
10 – Advertise multiple modes
11 – Disable auto-negotiation
Default is “00”(0).
ForceIntMode
This bit selects the source of internal port mode configuration. When this bit is ‘0’
the port's speed and duplex is configured according to Phy polling results,
otherwise it is set as indicated by following Speed and Duplex. Default is ‘0’.
Confidential.
Copyright © 2003, IC Plus Corp.
28/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
Speed
Used by the physical layer management polling entity to configure physical layer’s
speed mode when EEPROM forced modes are selected. Additionally this bit can be
used to directly force the internal speed mode.
00 – 10M
01 – 100M
10 – 1000M
Duplex
Used by the physical layer management polling entity to configure physical layer’s
duplex mode when EEPROM forced modes are selected. Additionally this bit can
be used to directly force the internal duplex mode.
ForceLnk
Setting this bit to '1' will force the internal polled link status of the corresponding port
to “ON”. Default is ‘0’.
TxDisable
Setting this bit to '1' will disable the transmission MAC device, thus inhibiting
transmission on the corresponding port. Default is ‘0’.
RxDisable
Setting this bit to '1' will disable the receiving MAC device, thus inhibiting receiving
on the corresponding port. Default is ‘0’.
DisFdxFCTx
Setting this bit to '1' will disable flow control operation for full duplex mode on
transmit side (transmission of pause frames). Default is ‘0’.
DisFdxFCRx
Setting this bit to '1' will disable flow control operation for full duplex mode on
receive side (pausing frame transmission). Default is ‘0’.
DisBackPres
Setting this bit to '1' will disable flow control for half duplex mode (backpressure).
Default value is its corresponding DisBkPr pin value.
PortPriorityEn
Setting this bit to '1' will force the corresponding port to the priority set within the
PortPriority field, otherwise the pin configuration will be used.
PortPriority
This bit will set one of the four priority classes on the corresponding port.
Confidential.
Copyright © 2003, IC Plus Corp.
29/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.3.3
Port [X] IFG Configuration Register
- Addresses: 19h - 20h
7 6 5 4 3 2 1 0
IFGConfigP[x]
IFGConfig
RedGbBndw
GbBndwSel
not used
Bit(s)
Field
Description
3-0
4
6-5
7
IFGConfig
RedGbBndw
GbBndwSel
not used
Interframe Gap Configuration
Reduced gigabit bandwidth
Gigabit bandwidth selection
not used
IFGConfig
These bits are used to set the minimum IFG with 32-bit time resolution. The default
matches the standard minimum IFG of 96-bit time: ‘0011’ (3).
IFGConfig
0001
0010
0011
0100
…
1111
0000
IFG (bit time)
32
64
96 (default)
128
…
480
512
RedGbBndw
Setting this bit to '1', will enable a 1000Mbps port to reduce its transmission
bandwidth to the percentage indicated by the GbBndwSel field. Setting this bit to
‘0’, the GbBndwSel field will be meaningless and the port will make use of its full
transmission bandwidth. This bit is in effect only when the port’s speed mode is
1000Mbps. Default is ‘0’.
GbBndwSel
Transmission bandwidth enforcement when in 1000 Mbps mode.
GbBndwSel
00
01
10
11
Transmission bandwidth
50%
66%
80%
90%
This feature can be used to avoid congestion in some LAN nodes without flow
control capabilities or to avoid server overloads
Confidential.
Copyright © 2003, IC Plus Corp.
30/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.3.4
Flow Control Register
- Address: 2Eh, 2Fh
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
FlowControlReg
FullBP
BPMaxCol
BPSkip1
CarrBP
DisFwPres
DisBPBk
FrcFdxFC
FrcFdxFCGb
DirFCAdr
not used
Bit(s)
Field
Description
0
6-1
7
8
9
10
11
12
13
15 - 14
FullBP
BPMaxCol
BPSkip1
CarrBp
DisFwPres
DisBPBk
FrcFdxFC
FrcFdxFCGb
DirFCAdr
not used
Full backpressure
Maximum number of collisions for backpressure
Skip one packet for backpressure operation
Carrier backpressure
Disable forwardpresure
Disable backoff during backpressure
Force full duplex flow control in 10/100 Mbps
Force full duplex flow control in 1000 Mbps
Direct flow control addressing
not used
FullBP
In normal operation the backpressure process is executed until flow control
condition disappears or until the time limit for backpressure is reached. This limit is
based on EEPROM’s BPTimeValue register. When this configuration is ‘0’ the
backpressure process will be also limited from exceeding the value contained in
BPMaxCol field.
Default value is its corresponding FullBP pin value.
BPMaxCol
Specifies the number of consecutive collisions that will determine TC9204M to quit
backpressure (see the setting above). Default is ‘011100’ (28).
BPSkip1
If FullBP setting is configured to ‘0’ and a number of BPMaxCol collisions is reached,
the MAC will ensure receiving the next packet without colliding it if this bit is set to ‘1’,
after which will resume the backpressure. Otherwise it will completely quit
backpressure waiting for a new XOFF command from internal flow control entity.
Default is ‘0’.
CarrBp
Setting this bit to ‘1’ will enable carrier-based backpressure, otherwise only
collision-based backpressure is executed. Default value is its corresponding
CarrBp pin value.
Confidential.
Copyright © 2003, IC Plus Corp.
31/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
DisFwPres
Whenever backpressure is enabled, in case of extreme congestion (memory
overload) forward pressure is also executed unless deactivated by this bit. Forward
pressure is never executed when backpressure is disabled. Setting this bit to ‘1’ will
disable forward pressure for all half duplex ports. Default is ‘0’.
DisBPBk
Setting this bit to ‘1’ will cause no backoff to be executed when a half duplex port is
in backpressure mode. This means a new collision can be forced immediately after
the previous one if carrier sense is observed. Setting this bit to ‘0’ will enable a very
aggressive backoff to be executed (recommended). Default value is its
corresponding DisBPBk pin value.
FrcFdxFC
Setting this bit to ‘1’ will instruct TC9204M to disregard the auto-negotiation result
for the full duplex flow control ability. Link partner will be considered full duplex flow
control able. This setting is effective only for ports configured in 10/100 Mbps speed
modes. Default is ‘0’.
FrcFdxFCGb
Setting this bit to ‘1’ will instruct TC9204M to disregard the auto-negotiation result
for the full duplex flow control ability. Link partner will be considered able to execute
symmetric and asymmetric towards link partner full duplex flow control. This setting
is effective only for ports configured in 1000 Mbps speed mode. Default is ‘0’.
DirFCAdr
Setting this bit to ‘1’ will enable direct flow control addressing mechanism, otherwise
direct flow control addressing is disabled. Default is ‘0’.
Confidential.
Copyright © 2003, IC Plus Corp.
32/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.3.5
Backpressure Time Value Register
- Address: 31h, 30h
15 14 13 12 11 10 9 8
31h
7 6 5 4 3 2 1 0
BPTimeValue
30h
BPTimeValue
Bit(s)
Field
Description
15 – 0
BPTimeValue
Backpressure time value
BPTimeValue
10.3.6
A 16 bit value used to compute internal time value for backpressure operation.
Default value is ‘0000100000000000’(2048).
Flow Control Port Base Address Register
- Address: 32h, 33h, 34h, 35h, 36h, 37h
47 46 45 44 43 42 41 40
39 38 37 36 35 34 33 32
31 30 29 28 27 26 25 24
23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
FCBaseAddress
FCBaseAddress
Bit(s)
Field
Description
47 – 0
FCBaseAddress
Source port base address for flow control packets
FCBaseAddress
Contains a 48-bit MAC address used to generate the individual port address used in
direct flow control addressing. The port addresses are obtained by incrementing
this base address and assigning the result to the TC9204M’s ports starting with port
0. The least significant 5 bits of this address will be ignored and replaced with ‘0’, so
these bits will encode the port number in the actual port address.
Confidential.
Copyright © 2003, IC Plus Corp.
33/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.3.7
Broadcast Configuration Register
- Address: 3Dh, 3Eh
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
BroadcastConfig
SrcLoadTrsh
FCBcstEn
FCBcstMode
not used
ThrotTrsh
BcstThrot
Reserved
not used
Bit(s)
Field
Description
4-0
5
6
7
11 -8
12
14 - 13
15
SrcLoadTrsh
FCBcstEn
FCBcstMode
not used
ThrotTrsh
BcstThrot
Reserved
not used
Source port loading limit for broadcast
Flow control broadcast enable
Flow control broadcast mode
not used
Global buffer pool loading threshold for broadcast
Broadcast throttling (bandwidth)
not used
SrcLoadTrsh
The maximum number of frame buffers used on each receiving port for broadcast.
Default is ‘11000’ (24).
FCBcstEn
Setting this bit to ‘1’ will enable flow control mechanism for broadcast frames.
Setting this bit to ‘0’ will cause broadcast packets to be dropped on queue overflow
condition. Default value is its corresponding FcBcstEn pin value.
FCBcstMode
This bit selects the source of flow control for broadcast operation:
‘0’ – broadcast flow control is issued on source port basis
‘1’ – broadcast flow control is issued by any of the two broadcast queues
Default value is its corresponding FcBcstMode pin value.
ThrotTrsh
Setting this bit to ‘1’ will enable bandwidth based broadcast throttling. The value
represents the maximum percentage of the full receiving bandwidth than can be
used for broadcast. Default is ‘00101’(5%).
BcstThrot
Setting this bit to ‘1’ will enable throttling for broadcast frames. Default value is its
corresponding BcstThrot pin value.
Confidential.
Copyright © 2003, IC Plus Corp.
34/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.3.8
IP Priority Mapping Register
- Address: 3Fh, 40h
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
IPTosMapping
Tos0Class
Tos1Class
Tos2Class
Tos3Class
Tos4Class
Tos5Class
Tos6Class
Tos7Class
Bit(s)
Field
Description
1-0
3-2
5-4
7-6
9-8
11 - 10
13 - 12
15 - 14
Tos0Class
Tos1Class
Tos2Class
Tos3Class
Tos4Class
Tos5Class
Tos6Class
Tos7Class
priority mapping for IP precedence 0
priority mapping for IP precedence 1
priority mapping for IP precedence 2
priority mapping for IP precedence 3
priority mapping for IP precedence 4
priority mapping for IP precedence 5
priority mapping for IP precedence 6
priority mapping for IP precedence 7
Tos[x]Class
This field maps the IP priority level x found in the incoming frame to one of the four
priority classes. The table bellow shows the mapping.
Tos[x]Class
00
01
10
11
CoS
Class 0 priority
Class 1 priority
Class 2 priority
Class 3 priority
x ranges in the field 0 to 7.
Confidential.
Copyright © 2003, IC Plus Corp.
35/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.3.9
VLAN Priority Mapping Register
- Address: 41h, 42h
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
VLANPriMapping
Pri0Class
Pri1Class
Pri2Class
Pri3Class
Pri4Class
Pri5Class
Pri6Class
Pri7Class
Bit(s)
Field
Description
1-0
3-2
5-4
7-6
9-8
11 - 10
13 - 12
15 - 14
Pri0Class
Pri1Class
Pri2Class
Pri3Class
Pri4Class
Pri5Class
Pri6Class
Pri7Class
priority mapping for VLAN user_priority 0
priority mapping for VLAN user_priority 1
priority mapping for VLAN user_priority 2
priority mapping for VLAN user_priority 3
priority mapping for VLAN user_priority 4
priority mapping for VLAN user_priority 5
priority mapping for VLAN user_priority 6
priority mapping for VLAN user_priority 7
Pri[x]Class
This field maps the VLAN priority level x found in the incoming frame to one of the
four priority classes. The table bellow shows the mapping.
Pri[x]Class
00
01
10
11
CoS
Class 0 priority
Class 1 priority
Class 2 priority
Class 3 priority
x ranges in the field 0 to 7.
Confidential.
Copyright © 2003, IC Plus Corp.
36/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.3.10
CoS Bandwidth Register
- Address: 43h, 44h
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
CoSBandwidth
Cos0Weight
not used
Cos1Weight
not used
Cos2Weight
not used
Cos3Weight
not used
Bit(s)
Field
Description
2-0
3
6-4
7
10 - 8
11
14 - 12
15
CoS0Weight
not used
CoS1Weight
not used
CoS2Weight
not used
CoS3Weight
not used
000
not used
The weight for priority class 1 queue
not used
The weight for priority class 2 queue
not used
The weight for priority class 3 queue
not used
CoS[y]Weight
This field sets the weight for its associated priority queue. The transmission
bandwidth percentage given to the associated queue is set by the formula below:
3
Queue y’s priority [%] = F(CoS[y]Weight) * 100 / Σ ( F(CoS[n]Weight) )
n=0
Note: y ranges in 0 to 3 and F is a tabled function described bellow:
f(“000”) = 1
f(“001”) = 2
f(“010”) = 4
f(“011”) = 8
10.3.11
f(“100”) = 16
f(“101”) = 32
f(“110”) = not used
f(“111”) = not used
Reserved Register
- Address: 45h, 46h
Confidential.
Copyright © 2003, IC Plus Corp.
37/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.3.12
CoS Configuration Register
- Address: 47h
7 6 5 4 3 2 1 0
CosConfig
EnIPPr
EnVLANPr
CosResolution
VLANPrec
DefCoS
not used
Bit(s)
Field
Description
0
1
2
3
5-4
7-6
EnIPPr
EnVLANPr
CoSResolution
VLANPrec
DefCoS
not used
Enable IP priority
Enable VLAN priority
CoS Resolution Mode
VLAN Precedence
Default Class of Service
not used
EnIPPr
Setting this field to ‘1’ will enable IP prioritization. CoS resolution function will
consider TOS Precedence bits from IP Header. Default value is its corresponding
EnIPPr pin value.
EnVLANPr
Setting this field to ‘1’ will enable VLAN prioritization. CoS resolution function will
consider user-priority bits (TCI field) from 802.1Q VLAN Tag Header. Default value
is its corresponding EnVLANPr pin value.
CoSResolution
When this bit is set to ‘0’ the CoS resolution function will assign to each frame the
highest CoS obtained from all enabled prioritization sources.
Setting this field to ‘1’, the resolution function will perform a prioritized parsing of
CoS sources, depending of VLANPrec bit. The CoS will be assigned considering
the first source that has been found within the frame (VLAN or IP). If none of the
VLAN or IP prioritization sources have been found then the port based prioritization
is considered if enabled, otherwise the frame will be assigned the default CoS.
Default is ‘1’.
VLANPrec
If CoSResolution field is set to ‘0’, this field is meaningless. When CoSResolution
field is set to ‘1’, this field will set the prioritization sources precedence for the
resolution function. A value of ‘1’ will set the following precedence (from highest to
lowest): VLAN priority, IP priority, port priority. A value of ‘0’ will set the following
precedence (from highest to lowest): IP priority, VLAN priority, port priority. Default
is ‘0’.
DefCoS
This is the CoS a frame will receive when port based prioritization is disabled and
both VLAN and IP headers are not found (or the corresponding VLAN / IP
prioritizations are also disabled). This configuration can be used especially when
CoSResolution setting is ‘0’. Default is “01” (CoS 1).
Confidential.
Copyright © 2003, IC Plus Corp.
38/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.3.13
Port Mirroring Register
- Address: 48h, 49h
15 14 13 12 11 10 9 8
7 6 5 4 3 2 1 0
PortMirrorReg
Source Port
not used
Destination port
not used
EnRxMirror
EnTxMirror
not used
not used
not used
Bit(s)
Field
Description
2-0
3
6-4
7
8
9
10
11
15 - 12
SourcePort
not used
DestinationPort
not used
EnRxMirror
EnTxMirror
not used
not used
not used
Source port(monitored port)
not used
Destination port(monitoring port)
not used
Enable mirroring on receiving packets
Enable mirroring on transmitting packets
not used
not used
not used
SourcePort
One of the eight ports of the switch that is intended for been monitored through port
mirroring feature. If enabled, the traffic on this port can be additionally forwarded to
the monitoring port. Only one port can be monitored at a time.
DestinationPort
One of the eight ports address’s of the switch that is intended to monitor one of the
other ports through port mirroring feature. This port will receive all traffic on the
mirror source port.
EnRxMirror
Setting this bit to ‘1’, the destination port will mirror all the source port’s incoming
traffic.
EnTxMirror
Setting this bit to ‘1’, the destination port will mirror all the source port’s outgoing
traffic.
Confidential.
Copyright © 2003, IC Plus Corp.
39/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.3.14
General Configuration Register
- Address: 4ah
7
6
5
4
3
2
1
0
G en eralC o n fig
AgeT imeR eg
D isA ging
F wdBadC R C
F wdU ndersize
R ejM C T
R ejR D A
not used
Bit(s)
Field
Description
1–0
2
3
4
5
6
7
AgeTimeReg
DisAging
FwdBadCRC
FwdUndersize
RejMCT
RejRDA
not used
Sets the aging time
Disable aging
Forward bad CRC packets
Forward undersized packets
Reject MAC Control Type frames
Reject 802.1D Reserved Group Addresses DA frames
not used
AgeTimeReg
Allows 4 values for the aging time to be chosen from.
00 – 300 seconds
01 – 600 seconds
10 – 900 seconds
11 – 1200 seconds
Default is ‘01’(600 seconds).
DisAging
Setting this bit to '1' will cause TC9204M to disable its aging mechanism for the
stored MAC addresses. Default is '0'.
FwdBadCRC
Setting this bit to ‘1’ will enable forwarding of bad CRC packets. Default is '0'.
FwdUndersize
Setting this bit to ‘1’ will enable forwarding of undersized packets. Default is '0'
RejMCT
Setting this bit to ‘1’ will configure the switch to filter all frames with MAC Control
Type (type 8808). Default is ‘0’.
RejRDA
Setting this bit to ‘1’ will configure the switch to filter all frames with 802.1D
Reserved Group Destination Address except for Bridge Group Address
(01-80-C2-00-00-00). Default value is its corresponding RejRDA pin value.
Confidential.
Copyright © 2003, IC Plus Corp.
40/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.3.15
Port VLAN Enable Register
- Address: 4fh
7
6
5
4
3
2
1
0
P o rtV L A N E n
VLAN0
VLAN1
VLAN2
VLAN3
Bit(s)
Field
Description
0
1
2
3
VLAN0
VLAN1
VLAN2
VLAN3
VLAN 0 enable
VLAN 1 enable
VLAN 2 enable
VLAN 3 enable
Enables/disables VLAN y. (y is in range 0 to 3)
VLAN[y]
10.3.16
VLAN [Y] Register
- Address: 50h, 52h, 54h, 56h, 58h, 5ah, 5ch, 5eh
7
6
5
4
3
2
1
0
V L A N [y ]R e g
P o rt0
N /A
P o rt2
N /A
P o rt4
N /A
P o rt6
N /A
Bit(s)
Field
Description
0
1
2
3
4
5
6
7
Port0
N/A
Port2
N/A
Port4
N/A
Port6
N/A
Port 0 membership to VLAN y
Port[x]
Port 2 membership to VLAN y
Port 4 membership to VLAN y
Port 6 membership to VLAN y
Port x membership to VLAN y.
‘0’ – Port x is not a member of VLAN y
‘1’ – Port x is a member of VLAN y
Confidential.
Copyright © 2003, IC Plus Corp.
41/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.4
Writing / Reading PHY management registers via EEPROM interface
The following set of registers allows read/write operations through MDIO interface for direct managing of
physical layer devices. This feature is available through virtual EEPROM mode.
10.4.1
Data Write Register
- Address: 70h, 71h
15 14 13 12 11 10 9 8
7 6 5 4 3 2 1 0
DataWriteReg
DataW riteReg
Bit(s)
Field
Description
15 - 0
DataWriteReg
MDIO Data Write Register
DataWriteReg
10.4.2
– Contains a 16 bit data word used to write a PHY management register.
Physical Layer Device Address Register
- Address: 72h
7 6 5 4 3 2 1 0
PhyAddress
DeviceAddress(4-0)
not used
Bit(s)
Field
Description
4–0
7–5
DeviceAddress
not used
Physical layer device address register
not used
DeviceAddress
– Contains a 5 bit word used as device address in MDIO operations.
Confidential.
Copyright © 2003, IC Plus Corp.
42/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.4.3
Physical Layer’s Register Address Register
- Address: 73h
7 6 5 4 3 2 1 0
RegAddress
RegAddress(4-0)
not used
Bit(s)
Field
Description
4–0
7–5
RegAddress
not used
Physical layer device’s register address register
not used
RegAddress
10.4.4
– Contains a 5 bit word used as register address in MDIO operations.
IO Status Control Register
- Address: 74h
7 6 5 4 3 2 1 0
IOControl
RnotW
ValidDataRead
MDIOError
not used
Bit(s)
Field
Description
0
1
2
3–7
RnotW
ValidDataRead
MDIOError
not used
Operation code
Valid Data Read
MDIO Error
not used
RnotW
– Operation Code. Setting this bit to ‘1’ will select read operation otherwise will
select write operation. MDIO Read / Write operation is started by performing a
virtual EEPROM write to IOControl register.
ValidDataRead
– Indicates if DataReadReg register contains valid data.
‘1’- data valid
‘0’- read not performed yet
MDIOError
– This bit signals errors on MDIO line.
‘1’- MDIO error.
‘0’- MDIO read successful.
Confidential.
Copyright © 2003, IC Plus Corp.
43/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
10.4.5
Data Read Register
- Address: 76h, 75h
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
76h
DataReadReg
75h
DataReadReg
Bit(s)
Field
Description
15 – 0
DataReadReg
MDIO Data Read Register
DataReadReg
– Contains a 16 bit data word read from a PHY management register.
Write Operation.
Before starting a write operation the following registers need to be set :
PhyAddress
– written with MDIO device address
RegAddress
– written with MDIO register address
DataWriteReg
– data word to be write to selected register
The write operation is then started by performing a write to IOControl register with bit 0 cleared.
Read Operation.
Before starting a read operation the following registers need to be set :
PhyAddress
– written with MDIO device address
RegAddress
– written with MDIO register address
The write operation is then started by performing a write to IOControl register with bit 0 set.
Subsequently, the IOControl register needs to be monitored in order to detect MDIO operation error
reported via IOControl’s bit 2. The ValidDataRead bit is always read as ‘1’ unless the EEPROM line is
driven at over 1MHz speed. If no error occurred then data can be read from DataReadReg.
Confidential.
Copyright © 2003, IC Plus Corp.
44/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
11 Timing Requirements
11.1
GMII / MII Receive Timing Requirements
Symbol
Rx_Clk
Rx_Clk
TsRx_Clk
ThRx_Clk
Description
Receive clock period GMII
Receive clock period MII
RxDv, RxData to Rx_Clk rising setup time
RxDv, RxData to Rx_Clk rising hold time
Min.
Typ.
Max.
Unit
2
0.5
8
40
-
-
ns
ns
ns
ns
Min.
Typ.
Max.
Unit
1
8
40
-
4
ns
ns
ns
TRx_Clk
Rx_Clk
RxDv
ThRx_Clk
RxData
TsRx_Clk
GMII / MII Receive
11.2
GMII / MII Transmit Timing
Symbol
TTx_Clk
TTx_Clk
TdTx_Clk
Description
Transmit clock period GMII
Transmit clock period MII
Tx_En, TxData to Tx_Clk rising delay
TTx_Clk
Tx_Clk
Tx_En
TdTx_Clk
TxData
GMII / MII Transmit
Confidential.
Copyright © 2003, IC Plus Corp.
45/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
11.3
PHY Management (MDIO) Timing
Symbol
Tch
Tcl
Tcm
Tmd
Tmh
Description
MDCK High Time
MDCK Low Time
MDCK period
MDIO output delay
MDIO hold time
Min.
Typ.
Max.
Unit
10
300
300
600
-
50
-
ns
ns
ns
ns
ns
MDClk
Tms
Tmh
MDIO
MDIO Write Cicle
MDClk
Tcl
Tch
Tmd
Tcm
MDIO
MDIO Read Cicle
Confidential.
Copyright © 2003, IC Plus Corp.
46/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
11.4
EEPROM Timing
Symbol
Description
Min.
Typ.
Max.
Unit
fSCL
tLOW
tHIGH
tBUF
SCL frequency
Clock Pulse Width Low
Clock Pulse Width High
Time the bus must be free before starting a
new transmission
Start Hold Time
Start Setup Time
Data Hold Time
Data Setup Time
Stop Set-up Time
Clock Low to Data Out Valid
Data Out Hold Time
10
10
5
66.6
-
-
KHz
us
us
us
5
5
5
5
5
0
-
4.9
-
us
us
us
us
us
us
us
tHD.STA
tSU.STA
tHD.DAT
tSU.DAT
tSU.STO
tAA
tDH
tLOW
tHIGH
SCL
tSU.STA
SDA
(output)
SDA
(input)
tHD.STA
tHD.DAT
tSU.DAT
tSU.STO tBUF
VALID
VALID
tDH
tAA
VALID
VALID
EEPROM Interface Timing
Confidential.
Copyright © 2003, IC Plus Corp.
47/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
12 Electrical Specifications
12.1
ABSOLUTE MAXIMUM RATINGS
Permanent device damage may occur if Absolute Maximum Ratings are exceeded. Functional operation
should be restricted to the conditions as specified in the Recommended Operating Conditions section.
Exposure to the Absolute Maximum Conditions for extended periods may affect device reliability.
PARAMETER
Supply Voltage
I/O
Core
Input Voltage
Output Voltage
Storage Temperature
Operation Temperature
Latch-up Current
SYMBOL
VDDI/O
VDDCore
VI
VO
TSTG
TOPT
ILATCH
MIN.
– 0.5
– 0.5
– 0.5
– 0.5
-65
0
MAX.
4.6
2.5
6
6
+150
70
UNIT
V
V
V
V
°C
°C
mA
>500
Note: The maximum ratings are the limit value that must never be exceeded even for short time.
12.2
RECOMMENDED OPERATING CONDITIONS
The recommended operating conditions represents recommended values that assure normal logic
operation. As long as the device is used within the recommended operating conditions, the electrical
characteristics (DC and AC characteristics) are guaranteed.
PARAMETER
Supply Voltage
I/O
Core
Junction Temperature
Low-level input voltage
High-level input voltage
12.3
SYMBOL
VDDI/O
VDDCore
Tj
VIL
VIH
MIN.
3.0
1.95
TYP.
3.3
2.0
MAX.
3.6
2.05
125
1.0
5.5
UNIT
V
V
°C
V
V
SYMBOL
VOL
VOH
IOL
IOH
VT
VT+
MIN.
TYP.
MAX.
0.4
2.4
8.8
12.8
1.46
1.66
14.1
25.7
1.60
1.75
17.0
40.0
1.76
1.79
UNIT
V
V
mA
mA
V
V
VT-
0.93
1.01
1.06
V
+/-10
+/-10
+/-1000
+/-1000
nA
nA
77
69
122
127
KΩ
KΩ
-0.5
2.0
DC CHARACTERISTICS
PARAMETER
Output low voltage
Output high voltage
Low level output current @VOL=0.4V
High level output current @VOH=2.4V
Input Treshold point
GMII Input (Schmitt trig.) Low to High
treshold point *1
GMII Input (Schmitt trig.) High to Low
treshold point *1
Input leakage current (High and Low)
Tri-state output leakage current (High
and Low)
Pull-up resistor
Pull-down resistor
Note: *1
II
IOZ
RPU
RPD
56
51
This refers to all inputs described as GMII in the Pin Listing section.
Confidential.
Copyright © 2003, IC Plus Corp.
48/49
July 29, 2003
TC9204M-DS-R05
TC9204M
Preliminary Data Sheet
13 Package Detail
Lead pitch
Package width x
Package length
Lead shape
Sealing method
0.50 mm
28 x 28 mm
Gullwing
Plastic mold
IC Plus Corp.
Headquarters
10F, No.47, Lane 2, Kwang-Fu Road, Sec. 2,
Hsin-Chu City, Taiwan 300, R.O.C.
TEL : 886-3-575-0275
FAX : 886-3-575-0475
Website: www.icplus.com.tw
Confidential.
Copyright © 2003, IC Plus Corp.
Sales Office
4F, No. 106, Hsin-Tai-Wu Road, Sec.1,
Hsi-Chih, Taipei Hsien, Taiwan 221, R.O.C.
TEL : 886-2-2696-1669
FAX : 886-2-2696-2220
49/49
July 29, 2003
TC9204M-DS-R05