TI SN74AS253AN

SN54ALS253, SN74ALS253, SN74AS253A
DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS
WITH 3-STATE OUTPUTS
SDAS216A – APRIL 1982 – REVISED DECEMBER 1994
•
•
•
•
3-State Versions of the ′ALS153 and
SN74AS153
Permits Multiplexing From n Lines to
One Line
Performs Parallel-to-Serial Conversion
Package Options Include Plastic
Small-Outline (D) Packages, Ceramic Chip
Carriers (FK), and Standard Plastic (N) and
Ceramic (J) 300-mil DIPs
SN54ALS253 . . . J PACKAGE
SN74ALS253, SN74AS253A . . . D OR N PACKAGE
(TOP VIEW)
1OE
B
1C3
1C2
1C1
1C0
1Y
GND
description
These data selectors/multiplexers contain
inverters and drivers to supply full binary decoding
data selection to the AND-OR gates. Separate
output control inputs are provided for each of the
two 4-line sections.
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
VCC
2OE
A
2C3
2C2
2C1
2C0
2Y
B
1OE
NC
VCC
2OE
SN54ALS253 . . . FK PACKAGE
(TOP VIEW)
The 3-state outputs can interface with and drive
data lines of bus-organized systems. With all but
one of the common outputs disabled (at a
high-impedance state), the low impedance of the
single enabled output drives the bus line to a high
or low logic level. Each output has its own
output-enable (OE) input. The output is disabled
when OE is high.
4
3
2 1 20 19
18
5
17
6
16
7
15
8
14
9 10 11 12 13
A
2C3
NC
2C2
2C1
1Y
GND
NC
2Y
2C0
1C3
1C2
NC
1C1
1C0
The SN54ALS253 is characterized for operation
over the full military temperature range of – 55°C
to 125°C. The SN74ALS253 and SN74AS253A
are characterized for operation from 0°C to 70°C.
NC – No internal connection
FUNCTION TABLE
INPUTS
SELECT†
DATA
OE
OUTPUT
Y
Z
B
A
C0
C1
C2
C3
X
X
X
X
X
X
H
L
L
L
X
X
X
L
L
L
L
H
X
X
X
L
H
L
H
X
L
X
X
L
L
L
H
X
H
X
X
L
H
H
L
X
X
L
X
L
L
H
L
X
X
H
X
L
H
H
H
X
X
X
L
L
L
H
H
X
X
X
H
L
† Select inputs A and B are common to both sections.
H
Copyright  1994, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1
SN54ALS253, SN74ALS253, SN74AS253A
DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS
WITH 3-STATE OUTPUTS
SDAS216A – APRIL 1982 – REVISED DECEMBER 1994
logic symbol†
A
B
1OE
1C0
1C1
1C2
1C3
2OE
2C0
2C1
2C2
2C3
14
2
0
1
1
6
5
4
3
EN
G 0
3
MUX
0
7
1
1Y
2
3
15
10
9
11
2Y
12
13
† This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
Pin numbers shown are for the D, J, and N packages.
logic diagram (positive logic)
1OE
1C0
1C1
1
6
5
7
Data 1
1C2
1C3
B
1Y
4
3
2
Select
A
2C0
2C1
Data 2
2C2
2C3
2OE
14
10
11
9
12
13
15
Pin numbers shown are for the D, J, and N packages.
2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
2Y
SN54ALS253, SN74ALS253, SN74AS253A
DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS
WITH 3-STATE OUTPUTS
SDAS216A – APRIL 1982 – REVISED DECEMBER 1994
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Voltage applied to a disabled 3-state output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Operating free-air temperature range, TA: SN54ALS253 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
SN74ALS253 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54ALS253
SN74ALS253
MIN
NOM
MAX
MIN
NOM
MAX
4.5
5
5.5
4.5
5
5.5
UNIT
VCC
VIH
Supply voltage
VIL
IOH
Low-level input voltage
0.7
0.8
High-level output current
–1
– 2.6
mA
IOL
TA
Low-level output current
12
24
mA
70
°C
High-level input voltage
2
Operating free-air temperature
2
– 55
125
V
V
0
V
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
TEST CONDITIONS
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = – 18 mA
IOH = – 0.4 mA
VCC = 4
4.5
5V
IOH = – 1 mA
IOH = – 2.6 mA
VOL
5V
VCC = 4
4.5
IOL = 12 mA
IOL = 24 mA
IOZH
IOZL
VCC = 5.5 V,
VCC = 5.5 V,
VO = 2.7 V
VO = 0.4 V
II
IIH
VCC = 5.5 V,
VCC = 5.5 V,
VI = 7 V
VI = 2.7 V
IIL
IO§
VCC = 5.5 V,
VCC = 5.5 V,
VI = 0.4 V
VO = 2.25 V
VOH
ICC
VCC = 5
5.5
5V
SN54ALS253
TYP‡
MAX
MIN
SN74ALS253
TYP‡
MAX
MIN
– 1.5
VCC – 2
2.4
– 1.5
UNIT
V
VCC – 2
V
3.3
2.4
0.25
– 20
0.4
3.2
0.25
0.4
0.35
0.5
V
µA
20
20
– 20
– 20
µA
0.1
0.1
mA
20
20
µA
– 0.1
– 0.1
mA
– 112
mA
– 112
– 30
Outputs high
6.5
12
6.5
12
Outputs disabled
7.5
14
7.5
14
mA
‡ All typical values are at VCC = 5 V, TA = 25°C.
§ The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
3
SN54ALS253, SN74ALS253, SN74AS253A
DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS
WITH 3-STATE OUTPUTS
SDAS216A – APRIL 1982 – REVISED DECEMBER 1994
switching characteristics (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
R1 = 500 Ω,
R2 = 500 Ω,
TA = MIN to MAX†
SN54ALS253
tPLH
tPHL
A or B
Any Y
tPLH
tPHL
Data
(any C)
Any Y
tPZH
tPZL
OE
Any Y
tPHZ
tPLZ
OE
Any Y
UNIT
SN74ALS253
MIN
MAX
MIN
MAX
5
30
5
21
5
27
5
21
2
15
2
10
3
18
3
14
3
20
3
14
2
19
4
16
2
12
2
10
2
18
2
14
ns
ns
ns
ns
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Operating free-air temperature range, TA: SN74AS253A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN74AS253A
VCC
VIH
Supply voltage
VIL
IOH
Low-level input voltage
IOL
TA
Low-level output current
4
High-level input voltage
MIN
NOM
MAX
4.5
5
5.5
2
High-level output current
Operating free-air temperature
0
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
UNIT
V
V
0.8
V
– 15
mA
48
mA
70
°C
SN54ALS253, SN74ALS253, SN74AS253A
DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS
WITH 3-STATE OUTPUTS
SDAS216A – APRIL 1982 – REVISED DECEMBER 1994
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
VOH
VOL
IOZH
IOZL
II
IIH
IIL
A, B
All others
A, B
All others
A, B
All others
IO‡
ICC
SN74AS253A
TYP†
MAX
TEST CONDITIONS
MIN
VCC = 4.5 V,
VCC = 4.5 V to 5.5 V,
II = – 18 mA
IOH = – 2 mA
VCC = 4.5 V,
VCC = 4.5 V,
IOH = – 15 mA
IOL = 48 mA
VCC = 5.5 V,
VCC = 5.5 V,
VO = 2.7 V
VO = 0.4 V
VCC = 5
5.5
5V
V,
VI = 7 V
5V
VCC = 5
5.5
V,
7V
VI = 2
2.7
VCC = 5
5.5
5V
V,
VI = 0
0.4
4V
VCC = 5.5 V,
VO = 2.25 V
Outputs high
VCC = 5.5 V
– 1.2
VCC – 2
2.4
V
V
3.2
0.35
0.5
V
50
µA
– 50
µA
0.2
0.1
40
20
–1
– 0.5
– 30
UNIT
– 112
18
29
Outputs low
20
32
Outputs disabled
21
33
mA
µA
mA
mA
mA
† All typical values are at VCC = 5 V, TA = 25°C.
‡ The output conditions have been chosen to produce a current that closely approximates one half of the true short-circuit output current, IOS.
switching characteristics (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A or B
Y
tPLH
tPHL
Data
(any C)
Y
tPZH
tPZL
OE
Any Y
tPHZ
tPLZ
OE
Any Y
VCC = 4.5 V to 5.5 V,
CL = 50 pF,
R1 = 500 Ω,
R2 = 500 Ω,
TA = MIN to MAX§
SN74AS253A
MIN
MAX
3
13.5
3
11.5
2.5
7.5
2.5
8
2
12.5
2.5
11.5
1
6
1
7
UNIT
ns
ns
ns
ns
§ For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
5
SN54ALS253, SN74ALS253, SN74AS253A
DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS
WITH 3-STATE OUTPUTS
SDAS216A – APRIL 1982 – REVISED DECEMBER 1994
PARAMETER MEASUREMENT INFORMATION
SERIES 54ALS/74ALS AND 54AS/74AS DEVICES
7V
RL = R1 = R2
VCC
S1
RL
R1
Test
Point
From Output
Under Test
CL
(see Note A)
From Output
Under Test
RL
Test
Point
From Output
Under Test
CL
(see Note A)
CL
(see Note A)
LOAD CIRCUIT FOR
BI-STATE
TOTEM-POLE OUTPUTS
LOAD CIRCUIT
FOR OPEN-COLLECTOR OUTPUTS
3.5 V
Timing
Input
Test
Point
LOAD CIRCUIT
FOR 3-STATE OUTPUTS
3.5 V
High-Level
Pulse
1.3 V
R2
1.3 V
1.3 V
0.3 V
0.3 V
Data
Input
tw
th
tsu
3.5 V
1.3 V
3.5 V
Low-Level
Pulse
1.3 V
0.3 V
1.3 V
0.3 V
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
VOLTAGE WAVEFORMS
PULSE DURATIONS
3.5 V
Output
Control
(low-level
enabling)
1.3 V
1.3 V
0.3 V
tPZL
Waveform 1
S1 Closed
(see Note B)
tPLZ
[3.5 V
1.3 V
tPHZ
tPZH
Waveform 2
S1 Open
(see Note B)
1.3 V
VOL
0.3 V
VOH
1.3 V
0.3 V
[0 V
3.5 V
1.3 V
Input
1.3 V
0.3 V
tPHL
tPLH
VOH
In-Phase
Output
1.3 V
1.3 V
VOL
tPLH
tPHL
VOH
Out-of-Phase
Output
(see Note C)
1.3 V
1.3 V
VOL
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. When measuring propagation delay items of 3-state outputs, switch S1 is open.
D. All input pulses have the following characteristics: PRR ≤ 1 MHz, tr = tf = 2 ns, duty cycle = 50%.
E. The outputs are measured one at a time with one transition per measurement.
Figure 1. Load Circuits and Voltage Waveforms
6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright  1998, Texas Instruments Incorporated